954 resultados para MOUTH BREATHING


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study sought to establish an accurate and reproducible T(2)-mapping cardiac magnetic resonance (CMR) methodology at 3 T and to evaluate it in healthy volunteers and patients with myocardial infarct. BACKGROUND: Myocardial edema affects the T(2) relaxation time on CMR. Therefore, T(2)-mapping has been established to characterize edema at 1.5 T. A 3 T implementation designed for longitudinal studies and aimed at guiding and monitoring therapy remains to be implemented, thoroughly characterized, and evaluated in vivo. METHODS: A free-breathing navigator-gated radial CMR pulse sequence with an adiabatic T(2) preparation module and an empirical fitting equation for T(2) quantification was optimized using numerical simulations and was validated at 3 T in a phantom study. Its reproducibility for myocardial T(2) quantification was then ascertained in healthy volunteers and improved using an external reference phantom with known T(2). In a small cohort of patients with established myocardial infarction, the local T(2) value and extent of the edematous region were determined and compared with conventional T(2)-weighted CMR and x-ray coronary angiography, where available. RESULTS: The numerical simulations and phantom study demonstrated that the empirical fitting equation is significantly more accurate for T(2) quantification than that for the more conventional exponential decay. The volunteer study consistently demonstrated a reproducibility error as low as 2 ± 1% using the external reference phantom and an average myocardial T(2) of 38.5 ± 4.5 ms. Intraobserver and interobserver variability in the volunteers were -0.04 ± 0.89 ms (p = 0.86) and -0.23 ± 0.91 ms (p = 0.87), respectively. In the infarction patients, the T(2) in edema was 62.4 ± 9.2 ms and was consistent with the x-ray angiographic findings. Simultaneously, the extent of the edematous region by T(2)-mapping correlated well with that from the T(2)-weighted images (r = 0.91). CONCLUSIONS: The new, well-characterized 3 T methodology enables robust and accurate cardiac T(2)-mapping at 3 T with high spatial resolution, while the addition of a reference phantom improves reproducibility. This technique may be well suited for longitudinal studies in patients with suspected or established heart disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helicobacter pylori infection is associated with peptic ulcer and gastric carcinoma. The oral cavity may be a reservoir for H. pylori; however, the results of studies on this subject are controversial. We employed single-step and nested polymerase chain reactions (PCR) to detect the presence of the vacA, ureA and 16S rDNA genes of H. pylori in the stomach, saliva and dental plaque of 30 subjects. The results were confirmed by sequencing. Nested 16S rDNA and ureA amplification was achieved in 80% of gastric, 30% of saliva and 20% of dental plaque specimens. Sequencing of 10, seven and four 16S rDNA products from stomach, saliva and dental plaque, respectively, showed > 99% identity with H. pylori. Sequencing of the other four oral cavity PCR products showed similarity with Campylobacter and Wolinella species. Additionally, the vacA genotype identified in the samples of different sites was the same within a given subject.H. pylori may be found in the oral cavity of patients with gastric infection, thus it could be a source of transmission. However, results obtained with detection methods based only on PCR should be interpreted with caution because other microorganisms that are phylogenetically very close to H. pylori are also present in the mouth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Sleep-disordered breathing is associated with major morbidity and mortality. However, its prevalence has mainly been selectively studied in populations at risk for sleep-disordered breathing or cardiovascular diseases. Taking into account improvements in recording techniques and new criteria used to define respiratory events, we aimed to assess the prevalence of sleep-disordered breathing and associated clinical features in a large population-based sample. METHODS: Between Sept 1, 2009, and June 30, 2013, we did a population-based study (HypnoLaus) in Lausanne, Switzerland. We invited a cohort of 3043 consecutive participants of the CoLaus/PsyCoLaus study to take part. Polysomnography data from 2121 people were included in the final analysis. 1024 (48%) participants were men, with a median age of 57 years (IQR 49-68, range 40-85) and mean body-mass index (BMI) of 25·6 kg/m(2) (SD 4·1). Participants underwent complete polysomnographic recordings at home and had extensive phenotyping for diabetes, hypertension, metabolic syndrome, and depression. The primary outcome was prevalence of sleep-disordered breathing, assessed by the apnoea-hypopnoea index. FINDINGS: The median apnoea-hypopnoea index was 6·9 events per h (IQR 2·7-14·1) in women and 14·9 per h (7·2-27·1) in men. The prevalence of moderate-to-severe sleep-disordered breathing (≥15 events per h) was 23·4% (95% CI 20·9-26·0) in women and 49·7% (46·6-52·8) in men. After multivariable adjustment, the upper quartile for the apnoea-hypopnoea index (>20·6 events per h) was associated independently with the presence of hypertension (odds ratio 1·60, 95% CI 1·14-2·26; p=0·0292 for trend across severity quartiles), diabetes (2·00, 1·05-3·99; p=0·0467), metabolic syndrome (2·80, 1·86-4·29; p<0·0001), and depression (1·92, 1·01-3·64; p=0·0292). INTERPRETATION: The high prevalence of sleep-disordered breathing recorded in our population-based sample might be attributable to the increased sensitivity of current recording techniques and scoring criteria. These results suggest that sleep-disordered breathing is highly prevalent, with important public health outcomes, and that the definition of the disorder should be revised. FUNDING: Faculty of Biology and Medicine of Lausanne, Lausanne University Hospital, Swiss National Science Foundation, Leenaards Foundation, GlaxoSmithKline, Ligue Pulmonaire Vaudoise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

STUDY OBJECTIVES: We sought to determine the effect of expiratory positive airway pressure on end expiratory lung volume (EELV) and sleep disordered breathing in obstructive sleep apnea patients. DESIGN: Observational physiology study PARTICIPANTS: We studied 10 OSA patients during sleep wearing a facial mask. We recorded 1 hour of NREM sleep without treatment (baseline) and 1 hour with 10 cm H2O EPAP in random order, while measuring EELV and breathing pattern. RESULTS: The mean EELV change between baseline and EPAP was only 13.3 mL (range 2-25 mL). Expiratory time was significantly increased with EPAP compared to baseline 2.64 +/- 0.54 vs 2.16 +/- 0.64 sec (P = 0.002). Total respiratory time was longer with EPAP than at baseline 4.44 +/- 1.47 sec vs 3.73 +/- 0.88 sec (P = 0.3), and minute ventilation was lower with EPAP vs baseline 7.9 +/- 4.17 L/min vs 9.05 +/- 2.85 L/min (P = 0.3). For baseline (no treatment) and EPAP respectively, the mean apnea+hypopnea index (AHI) was 62.6 +/- 28.7 and 56.8 +/- 30.3 events per hour (P = 0.4). CONCLUSION: In OSA patients during sleep, the application of 10 cm H2O EPAP led to prolongation of expiratory time with only marginal increases in FRC. These findings suggest important mechanisms exist to avoid hyperinflation during sleep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of radial k-space sampling and water-selective excitation on a novel navigator-gated cardiac-triggered slab-selective inversion prepared 3D steady-state free-precession (SSFP) renal MR angiography (MRA) sequence was investigated. Renal MRA was performed on a 1.5-T MR system using three inversion prepared SSFP approaches: Cartesian (TR/TE: 5.7/2.8 ms, FA: 85 degrees), radial (TR/TE: 5.5/2.7 ms, FA: 85 degrees) SSFP, and radial SSFP combined with water-selective excitation (TR/TE: 9.9/4.9 ms, FA: 85 degrees). Radial data acquisition lead to significantly reduced motion artifacts (P < 0.05). SNR and CNR were best using Cartesian SSFP (P < 0.05). Vessel sharpness and vessel length were comparable in all sequences. The addition of a water-selective excitation could not improve image quality. In conclusion, radial k-space sampling reduces motion artifacts significantly in slab-selective inversion prepared renal MRA, while SNR and CNR are decreased. The addition of water-selective excitation could not improve the lower CNR in radial scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For free-breathing, high-resolution, three-dimensional coronary magnetic resonance angiography (MRA), the use of intravascular contrast agents may be helpful for contrast enhancement between coronary blood and myocardium. In six patients, 0.1 mmol/kg of the intravascular contrast agent MS-325/AngioMARK was given intravenously followed by double-oblique, free-breathing, three-dimensional inversion-recovery coronary MRA with real-time navigator gating and motion correction. Contrast-enhanced, three-dimensional coronary MRA images were compared with images obtained with a T2 prepulse (T2Prep) without exogenous contrast. The contrast-enhanced images demonstrated a 69% improvement in the contrast-to-noise ratio (6.6 +/- 1.1 vs. 11.1 +/- 2.5; P < 0.01) compared with the T2Prep approach. By using the intravascular agent, extensive portions (> 80 mm) of the native left and right coronary system could be displayed consistently with sub-millimeter in-plane resolution. The intravascular contrast agent, MS-325/AngioMARK, leads to a considerable enhancement of the blood/muscle contrast for coronary MRA compared with T2Prep techniques. The clinical value of the agent remains to be defined in a larger patient series. J. Magn. Reson. Imaging 1999;10:790-799.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to investigate the impact of navigator timing on image quality in navigator-gated and real-time motion-corrected, free-breathing, three-dimensional (3D) coronary MR angiography (MRA) with submillimeter spatial image resolution. Both phantom and in vivo investigations were performed. 3D coronary MRA with real-time navigator technology was applied using variable navigator time delays (time delay between the navigator and imaging sequences) and varying spatial resolutions. Quantitative objective and subjective image quality parameters were assessed. For high-resolution imaging, reduced image quality was found as a function of increasing navigator time delay. Lower spatial resolution coronary MRA showed only minor sensitivity to navigator timing. These findings were consistent among volunteers and phantom experiments. In conclusion, for submillimeter navigator-gated and real-time motion-corrected 3D coronary MRA, shortening the time delay between the navigator and the imaging portion of the sequence becomes increasingly important for improved spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors developed a free-breathing black-blood coronary magnetic resonance (MR) angiographic technique with a potential for exclusive visualization of the coronary blood pool. Results with the MR angiographic technique were evaluated in eight healthy subjects and four patients with coronary disease identified at conventional angiography. This MR angiographic technique accurately depicted luminal disease in the patients and permitted visualization of extensive continuous segments of the native coronary tree in both the healthy subjects and the patients. Black-blood coronary MR angiography provides an alternative source of contrast enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.