989 resultados para Hygrothermal conditioning


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The screw conveyor system plays a fundamental role during the EPB tunnelling operations for the tunnel face pressure control. On the other hand, the use of additives such chemical foams is even more applied in order to extend the EPB technology to the cohesionless soils. Despite the extensive use of the EPB technique in urban environment, little knowledge exists in the understanding of the behavior of such conditioned soil during the excavation operations. At the Turin University of Technology the Tunnelling and Underground Space Centre, in the mainframe of a wider research on soil conditioning, has developed an experimental apparatus that simulates the extraction phase with screw conveyor from a pressurized tank. In this paper the apparatus is presented and the results of a first series of tests carried out on sand are discussed. © 2007 Taylor & Francis Group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

EPB tunnelling requires the application of soil conditioning to increase its field of applicability particularly for cohesionless soils. Choosing the most suitable conditioning set for the various soils requires the use of a feasible laboratory test which can permit to define the characteristics of the conditioned soils and provide measurable data. A series of tests has been carried out using a laboratory screw conveyor device which was designed for this purpose and which simulates the extraction of the spoil from a pressure chamber in a similar way as in EPB tunnelling. The tested soils were medium-grain sands with varying amounts of silt and the tested conditioned mixtures were obtained with different water contents and amounts of foam. A simple slump test was also used to analyze the global characteristics of the conditioned soils. The test has shown that the proposed laboratory procedure permits a quantitative comparison to be made between different conditioning amounts and agents on the basis of measurable parameters. © 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil conditioning consists of mixing and remolding the natural material during the mechanical excavation of tunnels, generally at low depth, with additives, in order to obtain suitable properties of plasticity and consistency for the excavated material, so becoming able to apply a counterpressure against natural earth pressure and groundwater flow towards the excavation chamber. The assessment and the control of the soil parameters and of machine performance are fundamental for a regular and safe excavation, also with regards to surface stability. This paper mainly focus on testing approach aimed to the proper soil conditioning with EPB shields, whose results have been validated at real scale. The influence of the water content and the amount of conditioning foam has been studied by the Authors. A proper definition of conditioning parameters can allow to extend the application field of Earth Pressure Balance (EPB) tunnel machines to various grain soil distribution, even in weak rock formations (e.g. siltstone or flysch). Importance of conditioning is reflected also on the possibility of a proper spoil disposal or better for its reuse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The building sector is widely recognized as having a major impact on sustainable development. Both in developed and developing countries, sustainability in buildings approaches are growing. Laterite dimension stone (LDS) is a building material that was traditionally used in sub-Saharan Africa, but its technical features still need to be assessed. This article presents some results of a study focused on the characterization of LDS exploited in Burkina Faso for building purposes. The measured average thermal conductivity is 0.51  W/mK, which increases with water content and evolves with the specific gravity and with porosity. Rock mineral phases (quartz, goethite, hematite, magnetite) are cemented by kaolinite. The porosity of the material is high (30%), with macropores visible on the surface and found in the rock inner structure as well. Results from the hygrothermal monitoring of a pilot building are also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acute leukaemias in relapse after allogeneic stem cell transplantation (SCT) respond poorly to donor leucocyte infusions (DLI) compared with chronic myeloid leukaemia (CML), at least in part because of faster disease kinetics. Fludarabine-containing 'non-myeloablative' chemotherapy followed by further allo SCT may offer more rapid and effective disease control. We report 14 patients with relapse after allo SCT for acute leukaemia [seven acute myeloid leukaemia (AML), five acute lymphoblastic leukaemia (ALL)] or refractory anaemia with excess blasts in transformation (RAEB-t, n = 2) treated with fludarabine, high-dose cytosine arabinoside (ara-C) and granulocyte colony-simulating factor (G-CSF) with (n = 10) or without (n = 2) idarubicin (FLAG +/- Ida) or DaunoXome (FLAG-X) (n = 2) and second allo SCT from the original donor. Donors were fully human leucocyte antigen (HLA) -matched in 13 cases with a single class A mismatch in one. Actuarial overall survival was 60% and disease-free survival was 26% at 58 months. Remissions after the second SCT were longer than those after the first bone marrow transplantation (BMT) in eight of the 13 assessable patients to date. Haematopoietic recovery was rapid. Transplants were well tolerated with no treatment-related deaths. The major complication was graft-versus-host disease (GvHD, acute >/= grade II-2 cases, chronic - eight cases, two limited, six extensive) although there have been no deaths attributable to this. FLAG +/- Ida and second allo SCT is a safe and useful approach and may be more effective than DLI in the treatment of acute leukaemias relapsing after conventional allo SCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graft-versus-host disease (GVHD) remains a significant complication in patients undergoing allogeneic stem cell transplantation (SCT) using a reduced intensity conditioning regimen. Although T-cell depletion (TCD) reduces the risk of GVHD after a myeloablative conditioning regimen, it is associated with an increased risk of graft failure. We have therefore examined whether TCD compromises engraftment using a fludarabine-based conditioning regimen. Fifteen patients have been transplanted using such a regimen of whom 13 underwent ex vivo TCD. All but one patient demonstrated durable engraftment and no patient receiving a TCD product developed severe GVHD. Thus, TCD may play a role in GvHD prophylaxis using such regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in situ experiment on a full-scale timber frame test building was carried out to study the hygrothermal performance of wood-hemp composite insulation in timber frame wall panels with and without a vapour barrier. The heat transfer properties and the likelihood of mould growth and condensation in the panels were compared. Step changes in the internal relative humidity were performed to explore the effects of high, normal and low internal moisture loads on the wall panels. No significant difference in the average equivalent thermal transmittance (U-values) between the panels with and without a vapour barrier was observed. The average equivalent U-values of the panels were close to the U-values calculated from the manufacturers’ declared thermal conductivity values of the insulation. The likelihood of condensation was higher at the interface of the wood-hemp insulation and the oriented strand board (OSB) in the panel without a vapour barrier. In terms of the parametric assessment of the mould germination potential, the relative humidity, the temperature and the exposure conditions in the insulation-OSB interfaces of the panel without a vapour barrier were found to be more favourable to the germination of mould spores. Nonetheless, when the insulations were dismantled, no mould was visually detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in situ experiment in a full scale timber frame test building was carried out to compare the hygrothermal performance of Hemp and Stone Wool insulations of identical thermal conductivity. Hemp and Stone Wool insulations were installed in timber frame wall panels without vapour barrier. The comparison was made in terms of heat transfer properties, likelihood of mould growth and condensation. Step changes in internal relative humidity were performed to explore the effect of high and normal internal moisture load on the wall panels. No significant difference between the average equivalent thermal transmittance (U-values) of the panels incorporating Hemp and Stone Wool insulations was observed. The average equivalent U-values of the panels were closer to the calculated U-values of the panels based on the manufacturers’ declared thermal conductivity of Hemp and Stone Wool insulations. It was observed that the placement of heat flux sensor along the depth of the insulation had significant influence on the measured equivalent U-value of the panels during high internal moisture load. The frequency and likelihood of condensation was higher in the interface of Stone Wool and Oriented Strand Board (OSB). In terms of the parametric assessment of mould germination potential, relative humidity, temperature and exposure conditions in the insulation-OSB interfaces were found to be favourable to germination of mould spore. However, when the insulations were dismantled, no mould was visually detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moisture and heat management properties of Hemp and Stone Wool insulations were studied by mounting them between a hot and a cold climate chamber. Both insulations were exposed to identical hygrothermal boundary conditions. Quasi steady state and dynamic tests were carried out at a range of relative humidity exposures. The likelihood of interstitial condensation was assessed and equivalent thermal conductivity values of the insulations were determined. The adsorption-desorption isotherms of the insulations were also determined in a dynamic vapour sorption (DVS) instrument. It was observed that the likelihood of condensation was higher in Stone Wool insulation than in Hemp insulation. Hemp insulation performed better in managing moisture due to its high hygric inertia and water absorption capacity. It was observed that the equivalent thermal conductivity of Stone Wool insulation was dependent on enthalpy flow and phase change of moisture. The equivalent thermal conductivity of Hemp insulation was close to its declared thermal conductivity in dynamic conditions when high relative humidity exposures were transient. In quasi steady state boundary conditions, when the insulation was allowed to reach the equilibrium moisture content at ranges of relative humidity, there was a moisture dependent increase of thermal conductivity in Hemp insulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The freshwater mollusc Lymnaea stagnalis was utilized in this study to further the understanding of how network properties change as a result of associative learning, and to determine whether or not this plasticity is dependent on previous experience during development. The respiratory and neural correlates of operant conditioning were first determined in normally reared Lymnaea. The same procedure was then applied to differentially reared Lymnaea, that is, animals that had never experienced aerial respiration during their development. The aim was to determine whether these animals would demonstrate the same responses to the training paradigm. In normally reared animals, a behavioural reduction in aerial respiration was accompanied by numerous changes within the neural network. Specifically, I provide evidence of changes at the level of the respiratory central pattern generator and the motor output. In the differentially reared animals, there was little behavioural data to suggest learning and memory. There were, however, significant differences in the network parameters, similar to those observed in normally reared animals. This demonstrated an effect of operant conditioning on differentially reared animals. In this thesis, I have identified additional correlates of operant conditioning in normally reared animals and provide evidence of associative learning in differentially reared animals. I conclude plasticity is not dependent on previous experience, but is rather ontogenetically programmed within the neural network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of my research was to develop and refine pedagogic approaches, and establish fitness baselines to adapt fitness and conditioning programs for Moderate-functioning ASD individuals. I conducted a seven-week study with two teens and two trainers. The trainers implemented individualized fitness and conditioning programs that I developed. I conducted pre and post fitness baselines for each teen, a pre and post study interview with the trainers, and recorded semi-structured observations during each session. I used multi-level, within-case and across case analyses, working inductively and deductively. My findings indicated that fundamental movement concepts can be used to establish fitness baselines and develop individualized fitness programs. I tracked and evaluated progressions and improvements using conventional measurements applied to unconventional movements. This process contributed to understanding and making relevant modifications to activities as effective pedagogic strategies for my trainers. Further research should investigate fitness and conditioning programs with lower functioning ASD individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

De nos jours, l'utilisation accrue de combustibles à base de fossiles et l'électricité met en péril l'environnement naturel à cause des niveaux élevés de pollution. Il est donc plausible de prévoir des économies d'énergie significatives grâce à la climatisation dite «naturelle»». En accord avec les objectifs acceptés à l'échelle internationale d'une architecture «verte» et durable, l'utilisation de cours intérieures associées aux capteurs de vent, aux murs-Trombe et à d'autres systèmes de climatisation naturelle (aussi bien traditionnels que nouveaux), paraît prometteuse. Ce mémoire propose une analyse de nouvelles approches à la climatisation naturelle et à la production d'air frais avec une consommation minimale d'énergie, eu égard aux traditions et aux tendances, en particulier dans les zones climatiques chaudes et sèches comme l'Iran. Dans ce contexte, regarder l'architecture de l'Islam et la discipline du Qur'an paraissent offrir un guide pour comprendre l'approche musulmane aux processus de décision en design. Nous regardons donc les traditions et les tendances en ce qui concerne la climatisation naturelle à travers l'élément le plus important du contexte islamique, à savoir le Qur'an. C'est pourquoi, à l'intérieur du thème de la tradition, nous avons pris en compte quelques considérations concernant l'influence de l'Islam, et en particulier le respect de la nature associé à un équilibre entre l'harmonie et l'individualité. Ce sont autant de facteurs qui influencent la prise de décisions visant à résoudre des problèmes scientifiques majeurs selon la philosophie et les méthodes islamiques ; ils nous permettent de faire quelques recommandations. La description des principes sous-jacents aux capteurs à vent et des antécédents trouvés dans la nature tels que les colonies de termites, est présentée également. Sous la rubrique tendances, nous avons introduit l'utilisation de matériaux et de principes de design nouveaux. Regarder simultanément ces matériaux nouveaux et l'analogie des colonies de termites suggère de bonnes approches à la conception d'abris pour les victimes de tremblements de terre dans les régions sisimques. Bam, une ville iranienne, peut être considérée comme un exemple spécifique illustrant où les principes exposés dans ce mémoire peuvent s'appliquer le plus adéquatement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data centre is a centralized repository,either physical or virtual,for the storage,management and dissemination of data and information organized around a particular body and nerve centre of the present IT revolution.Data centre are expected to serve uniinterruptedly round the year enabling them to perform their functions,it consumes enormous energy in the present scenario.Tremendous growth in the demand from IT Industry made it customary to develop newer technologies for the better operation of data centre.Energy conservation activities in data centre mainly concentrate on the air conditioning system since it is the major mechanical sub-system which consumes considerable share of the total power consumption of the data centre.The data centre energy matrix is best represented by power utilization efficiency(PUE),which is defined as the ratio of the total facility power to the IT equipment power.Its value will be greater than one and a large value of PUE indicates that the sub-systems draw more power from the facility and the performance of the data will be poor from the stand point of energy conservation. PUE values of 1.4 to 1.6 are acievable by proper design and management techniques.Optimizing the air conditioning systems brings enormous opportunity in bringing down the PUE value.The air conditioning system can be optimized by two approaches namely,thermal management and air flow management.thermal management systems are now introduced by some companies but they are highly sophisticated and costly and do not catch much attention in the thumb rules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work identifies the importance of plenum pressure on the performance of the data centre. The present methodology followed in the industry considers the pressure drop across the tile as a dependant variable, but it is shown in this work that this is the only one independent variable that is responsible for the entire flow dynamics in the data centre, and any design or assessment procedure must consider the pressure difference across the tile as the primary independent variable. This concept is further explained by the studies on the effect of dampers on the flow characteristics. The dampers have found to introduce an additional pressure drop there by reducing the effective pressure drop across the tile. The effect of damper is to change the flow both in quantitative and qualitative aspects. But the effect of damper on the flow in the quantitative aspect is only considered while using the damper as an aid for capacity control. Results from the present study suggest that the use of dampers must be avoided in data centre and well designed tiles which give required flow rates must be used in the appropriate locations. In the present study the effect of hot air recirculation is studied with suitable assumptions. It identifies that, the pressure drop across the tile is a dominant parameter which governs the recirculation. The rack suction pressure of the hardware along with the pressure drop across the tile determines the point of recirculation in the cold aisle. The positioning of hardware in the racks play an important role in controlling the recirculation point. The present study is thus helpful in the design of data centre air flow, based on the theory of jets. The air flow can be modelled both quantitatively and qualitatively based on the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study the effect of hot air recirculation is studied with suitable assumptions. It identifies that, the pressure drop across the tile is a dominant parameter which governs the recirculation. The rack suction pressure of the hardware along with the pressure drop across the tile determines the point of recirculation in the cold aisle. The positioning of hardware in the racks play an important role in controlling the recirculation point. The present study is thus helpful in the design of data centre air flow, based on the theory of jets. The air flow can be modelled both quantitatively and qualitatively based on the results