991 resultados para solid dosage form


Relevância:

80.00% 80.00%

Publicador:

Resumo:

AC Biosusceptometry (ACB) is a low-cost biomagnetic tool that has been successfully applied on pharmaceutical research to evaluate performance of solid dosage forms. The aim of this work was to evaluate the Horn & Shunck method to access tablet disintegration. To evaluate the HS results was record on video a test with a objet moving in a rail with a constant velocity. The desintegration was recorded on video and ACB, which used have seven pairs of detection coils and a pair of excitation coils to mensure the magnetic ux variation. The signals were ampli ed and digitalized to create images, which were restored by Wiener lter, while the video images are converted to gray scale, both are normalized and binarized and had the optical ow estimation calculated by Horn & Schunck (HS) algorithm. All signals and images are processed and developed algorithm on Matlab. During the tests the ve tablets (500mg ferrite, 375mg excipients, compression 10 to 50 kN) were on a becker between of the ACB system and of the video system, and only touching the surface of the water. With all OF maps calculated was realized the sum of the resultants of each, to get a disintegration process resultant for each compression. Whit that was possible observed the disintegration behaves. For the compression force study the HS components of each sequence was sum, take mean and normalized for sequence's max modulo, therefore can be observed a high growing on less compression tablets. We can conclude the HS algorithm is viable to tablets disintegration data collection and whit that was possible to create a tablets disintegration analyzes protocol, which would be useful on desintegration kinetics study

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oral administration is widely accepted route for drug delivery and solid dosage forms are commonly employed. The variation of absorption profiles along the human gastrointestinal tract (GIT) and the ability to target drugs by adequate dosage forms to distinct sites is the challenge in the pharmaceutical development of solid dosage forms. AC Biosusceptometry (ACB) is a technique that deserves consideration due to its features, accuracy of results and versatility. The purpose of this work was to evaluate, by employing the AC Biosusceptometer, the rate of swelling of systems matrices consisting of hydrophilic polymer (hydroxypropyl methyl cellulose) and magnetic material. Matrices tablets were evaluated in vitro to a more detailed analysis of kinetics of swelling, in addition to the study and application of mathematical models to correlate the magnetic area variation and the water uptake. All the procedures for qualitative and quantitative analysis of digital signals as well as the magnetic images processing were performed in MatLab® (Mathworks Inc.). ACB technique proved to be useful towards estimating the swelling properties of hydrophilic matrices in vitro, showing a promising capacity for further analyses involving dissolution test and in vivo studies, supporting their innovative potential pharmaceutical applications

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sodium azumolene is a drug designed to fight Malignant Hyperthermia (MH), which is characterized by genetic predisposition and triggered by the use of inhalational anesthetics. This drug is shown as a water-soluble analogue of dantrolene sodium, 30-folds more water soluble, which gives advantages for its emergency use. To our knowledge there is no analytical method for sodium zaumolene raw material or dosage form published so far. The objective of the present investigation was to develop and validate analytical methods to achieve sodium azumolene chemical identification and quantification. The sodium azumolene was characterized regarding its thermal behavior, by differential thermal analysis and thermogravimetric analysis; Visible, UV and infrared absorption. To accurately assess the sodium Azumolene content three different analytical methods (visible and UV spectrophotometry and high performance liquid chromatography) were developed and validated. All methods showed to be linear, accurate, precise and reliable. Azumolene has shown to be equipotent to dantrolene in the treatment and prevention of an MH crisis and the great advantage compared to dantrolene is better water solubility. This study has characterized the sodium azumolene and presents new analytical methods which have not been reported so far.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims: Darunavir is widely used in HIV/AIDS therapy. It is a HIV protease inhibitor that has excellent efficacy against the virus. The aim of this study is to develop and validate an analytical method fast and free of interferences for determination of darunavir ethanolate as raw material and tablet dosage form. Methodology: As the formulation excipients show high interference in darunavir determination by a direct UV absorption measurement a derivative spectrophotometry was applied. A selective, easy and fast method was achieved employing simple and cheap instrumentation by using first-order derivative spectrophotometry. Results: The first-derivation of spectrum of the drug measured between 200 and 400 nm allowed identification of the analyte and showed absence of placebo interference. The assay was based on the absorbance at 276nm. The linear concentration range was established from 11 to 21 μg/mL. The intra-day and inter-day precision expressed as RSD was 0.06% and 3.75% respectively with mean recovery of 99.84%. Conclusion: The proposed analytical method is able to quantify darunavir as raw material and tablets and can be used routinely by any laboratory applying a spectrophotometer with a derivative accessory. The great difference of the method proposed here is that it proves to be free of placebo interferences as well as simple, fast and low cost.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study is to develop and validate a dissolution test for fluconazole, an antifungal used for the treatment of superficial, cutaneous, and cutaneomucous infections caused by Candida species, in capsules dosage form. Techniques by HPLC and UV first derivative spectrophotometry (UV-FDS) were selected for quantitative evaluation. In the development of release profile, several conditions were evaluated. Dissolution test parameters were considered appropriate when a most discriminative release profile for fluconazole capsules was yielded. Dissolution test conditions for fluconazole capsules were 900 mL of HCl 0.1 M, 37 ± 0.5 °C using baskets with 50 rpm for 30 min of test. The developed HPLC and UV-FDS methods for the antifungal evaluation were selective and met requirements for an appropriate and validated method, according to ICH and USP requirements. Both methods can be useful in the registration process of new drugs or their renewal. For routine analysis application cost, simplicity, equipment, solvents, speed, and application to large or small workloads should be observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Solid-state characterization of crystalline drugs is an important pre-formulation step for the development and design of solid dosage forms, such as pellets and tablets. In this study, phase transition and dehydration processes of nevirapine have been studied by differential scanning calorimetry and thermogravimetry differential thermal analysis to overcome the problems of drug formulation, namely poor solubility and poor content uniformity. Phase solubility studies elucidated the mechanism of enhanced nevirapine solubility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ZusammenfassungDie Sekretion von Arzneistoffen aus Darmzellen zurück ins Darmlumen, die durch intestinale Transporter wie P-Glykoprotein (P-GP) vermittelt wird, stellt eine bekannte Quelle für unvollständige und variable Bioverfügbarkeiten und für Interaktionen mit anderen Arzneimitteln und Nahrungsbestandteilen dar. Dennoch liegen bisher keine Veröffentlichungen vor, die sich mit daraus resultierenden Konsequenzen für die Entwicklung neuer peroraler Darreichungsformen befassen. Ziel der vorliegenden Arbeit war es, deutlich zu machen, dass dem Auftreten von intestinalen Sekretionsphänomenen bei der Entwicklung von Retardarzneimitteln Rechnung getragen werden muss.Dazu wurden effektive Permeabilitäten für den Modellarzneistoff Talinolol in unterschiedlichen Darmabschnitten anhand eines Rattendarmperfusionsmodells bestimmt.Des weiteren wurde eine Retardformulierung für den Modellarzneistoff Talinolol entwickelt. Dabei wurde gezeigt, dass die Verwendung unterschiedlicher Puffer als Wirkstofffreisetzungmedien zur Ausbildung unterschiedlicher Talinolol-Kristallstrukturen führt.Die neu entwickelten Retardmatrixtabletten wurden mit Hilfe des Pharmakokinetik-Computersoftwareprogrammes Gastro Plus® evaluiert. Das Zusammenspiel von verlangsamter Wirkstofffreigabe aus der Arzneiform und intestinaler Sekretion führte zu einer deutlich verringerten Bioverfügbarkeit der Modellsubstanz Talinolol aus der Retardformulierung im Vergleich zu schnellfreisetzenden Arzneiformen.Daher sollte der Einfluß intestinaler sekretorischer Transporter wie P-GP bei der Entwicklung von Retardarzneiformen unbedingt berücksichtigt werden.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In der Herstellung fester Darreichungsformen umfasst die Granulierung einen komplexen Teilprozess mit hoher Relevanz für die Qualität des pharmazeutischen Produktes. Die Wirbelschichtgranulierung ist ein spezielles Granulierverfahren, welches die Teilprozesse Mischen, Agglomerieren und Trocknen in einem Gerät vereint. Durch die Kombination mehrerer Prozessstufen unterliegt gerade dieses Verfahren besonderen Anforderungen an ein umfassendes Prozessverständnis. Durch die konsequente Verfolgung des PAT- Ansatzes, welcher im Jahre 2004 durch die amerikanische Zulassungsbehörde (FDA) als Guideline veröffentlicht wurde, wurde der Grundstein für eine kontinuierliche Prozessverbesserung durch erhöhtes Prozessverständnis, für Qualitätserhöhung und Kostenreduktion gegeben. Die vorliegende Arbeit befasste sich mit der Optimierung der Wirbelschicht-Granulationsprozesse von zwei prozesssensiblen Arzneistoffformulierungen, unter Verwendung von PAT. rnFür die Enalapril- Formulierung, einer niedrig dosierten und hochaktiven Arzneistoffrezeptur, wurde herausgefunden, dass durch eine feinere Zerstäubung der Granulierflüssigkeit deutlich größere Granulatkörnchen erhalten werden. Eine Erhöhung der MassRatio verringert die Tröpfchengröße, dies führt zu größeren Granulaten. Sollen Enalapril- Granulate mit einem gewünschten D50-Kornverteilung zwischen 100 und 140 um hergestellt werden, dann muss die MassRatio auf hohem Niveau eingestellt werden. Sollen Enalapril- Granulate mit einem D50- Wert zwischen 80 und 120µm erhalten werden, so muss die MassRatio auf niedrigem Niveau eingestellt sein. Anhand der durchgeführten Untersuchungen konnte gezeigt werden, dass die MassRatio ein wichtiger Parameter ist und zur Steuerung der Partikelgröße der Enalapril- Granulate eingesetzt werden kann; unter der Voraussetzung dass alle anderen Prozessparameter konstant gehalten werden.rnDie Betrachtung der Schnittmengenplots gibt die Möglichkeit geeignete Einstellungen der Prozessparameter bzw. Einflussgrößen zu bestimmen, welche dann zu den gewünschten Granulat- und Tabletteneigenschaften führen. Anhand der Lage und der Größe der Schnittmenge können die Grenzen der Prozessparameter zur Herstellung der Enalapril- Granulate bestimmt werden. Werden die Grenzen bzw. der „Design Space“ der Prozessparameter eingehalten, kann eine hochwertige Produktqualität garantiert werden. rnUm qualitativ hochwertige Enalapril Tabletten mit der gewählten Formulierung herzustellen, sollte die Enalapril- Granulation mit folgenden Prozessparametern durchgeführt werden: niedrige Sprührate, hoher MassRatio, einer Zulufttemperatur von mindestens > 50 °C und einer effektiven Zuluftmenge < 180 Nm³/h. Wird hingegen eine Sprührate von 45 g/min und eine mittlere MassRatio von 4.54 eingestellt, so muss die effektive Zuluftmenge mindestens 200 Nm³/h und die Zulufttemperatur mindestens 60 °C betragen, um eine vorhersagbar hohe Tablettenqualität zu erhalten. Qualität wird in das Arzneimittel bereits während der Herstellung implementiert, indem die Prozessparameter bei der Enalapril- Granulierung innerhalb des „Design Space“ gehalten werden.rnFür die Metformin- Formulierung, einer hoch dosierten aber wenig aktiven Arzneistoffrezeptur wurde herausgefunden, dass sich der Wachstumsmechanismus des Feinanteils der Metformin- Granulate von dem Wachstumsmechanismus der D50- und D90- Kornverteilung unterscheidet. Der Wachstumsmechanismus der Granulate ist abhängig von der Partikelbenetzung durch die versprühten Flüssigkeitströpfchen und vom Größenverhältnis von Partikel zu Sprühtröpfchen. Der Einfluss der MassRatio ist für die D10- Kornverteilung der Granulate vernachlässigbar klein. rnMit Hilfe der Störgrößen- Untersuchungen konnte eine Regeleffizienz der Prozessparameter für eine niedrig dosierte (Enalapril)- und eine hoch dosierte (Metformin) Arzneistoffformulierung erarbeitet werden, wodurch eine weitgehende Automatisierung zur Verringerung von Fehlerquellen durch Nachregelung der Störgrößen ermöglicht wird. Es ergibt sich für die gesamte Prozesskette ein in sich geschlossener PAT- Ansatz. Die Prozessparameter Sprührate und Zuluftmenge erwiesen sich als am besten geeignet. Die Nachregelung mit dem Parameter Zulufttemperatur erwies sich als träge. rnFerner wurden in der Arbeit Herstellverfahren für Granulate und Tabletten für zwei prozesssensible Wirkstoffe entwickelt. Die Robustheit der Herstellverfahren gegenüber Störgrößen konnte demonstriert werden, wodurch die Voraussetzungen für eine Echtzeitfreigabe gemäß dem PAT- Gedanken geschaffen sind. Die Kontrolle der Qualität des Produkts findet nicht am Ende der Produktions- Prozesskette statt, sondern die Kontrolle wird bereits während des Prozesses durchgeführt und basiert auf einem besseren Verständnis des Produktes und des Prozesses. Außerdem wurde durch die konsequente Verfolgung des PAT- Ansatzes die Möglichkeit zur kontinuierlichen Prozessverbesserung, zur Qualitätserhöhung und Kostenreduktion gegeben und damit das ganzheitliche Ziel des PAT- Gedankens erreicht und verwirklicht.rn

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Serpentinization of abyssal peridotites is known to produce extremely reducing conditions as a result of dihydrogen (H2,aq) release upon oxidation of ferrous iron in primary phases to ferric iron in secondary minerals by H2O.We have compiled and evaluated thermodynamic data for Fe-Ni-Co-O-S phases and computed phase relations in fO2,g-fS2,g and aH2,aq-aH2S,aq diagrams for temperatures between 150 and 400°C at 50MPa.We use the relations and compositions of Fe-Ni-Co-O-S phases to trace changes in oxygen and sulfur fugacities during progressive serpentinization and steatitization of peridotites from the Mid-Atlantic Ridge in the 15°20'N Fracture Zone area (Ocean Drilling Program Leg 209). Petrographic observations suggest a systematic change from awaruite- magnetite-pentlandite and heazlewoodite-magnetite-pentlandite assemblages forming in the early stages of serpentinization to millerite-pyrite-polydymite-dominated assemblages in steatized rocks. Awaruite is observed in all brucite-bearing partly serpentinized rocks. Apparently, buffering of silica activities to low values by the presence of brucite facilitates the formation of large amounts of hydrogen, which leads to the formation of awaruite. Associated with the prominent desulfurization of pentlandite, sulfide is removed from the rock during the initial stage of serpentinization. In contrast, steatitization indicates increased silica activities and that highsulfur-fugacity sulfides, such as polydymite and pyrite-vaesite solid solution, form as the reducing capacity of the peridotite is exhausted and H2 activities drop. Under these conditions, sulfides will not desulfurize but precipitate and the sulfur content of the rock increases. The co-evolution of fO2,g-fS2,g in the system follows an isopotential of H2S,aq, indicating that H2S in vent fluids is buffered. In contrast, H2 in vent fluids is not buffered by Fe-Ni-Co-O-S phases, which merely monitor the evolution of H2 activities in the fluids in the course of progressive rock alteration.The co-occurrence of pentlandite- awaruite-magnetite indicates H2,aq activities in the interacting fluids near the stability limit of water. The presence of a hydrogen gas phase would add to the catalyzing capacity of awaruite and would facilitate the abiotic formation of organic compounds.