922 resultados para energy efficiency, performance assessment, retrofit
Resumo:
The Legislative Council created the Energy Efficiency Plans and Programs Study Committee for the 2008 Legislative Interim pursuant to the passage of S.F. 2386 during the 2008 Legislative Session, which provided, in Section 8: The Legislative Council is requested to establish an interim study committee to examine the existence and effectiveness of energy efficiency plans and programs implemented by gas and electric public utilities, with an emphasis on results achieved by current plans and programs from the demand, or customer, perspective, and to make recommendations for additional requirements applicable to energy efficiency plans and programs that would improve such results. In conducting the study and developing recommendations, the Committee shall consider testimony from the Iowa Utilities Board, rate and nonrate-regulated gas and electric utilities, the Consumer Advocate, state agencies involved with energy efficiency program administration, environmental groups and associations, and consumers.
Resumo:
BACKGROUND AND AIMS: Fish oil (FO) supplementation prevents the development of obesity and insulin resistance, and upregulate the expression of UCP3 in skeletal muscle in rodents. This may represent indirect evidence that FO promotes fat oxidation and/or alter energy efficiency. The aim of this study was to evaluate whether such effects can be observed in humans. The metabolic effects of FO were assessed during exercise in order to obtain a direct measurement of energy efficiency. METHODS: Eight healthy male volunteers were studied with and without supplementation with 7.2 g/day FO (including 1.1 g/day eicosopentaenoic acid and 0.7 g/day decosahexaenoic acid) during 14 days. Their VO(2 max) was measured on cycle ergometer. Thereafter, energy metabolism (substrate oxidation, energy expenditure and energy efficiency) was assessed during a 30 min cycling exercise at 50% VO(2 max) performed 2 h 30 after a standardized, high carbohydrate breakfast. RESULTS: VO(2 max) was 38.6+/-2.2 after FO and 38.4+/-2.0 (mL x kg(-1) x min(-1)) in control conditions (NS). Basal plasma glucose, insulin and NEFA concentrations, and energy metabolism were similar with FO and in controls. During exercise, the increases in plasma NEFA concentrations, energy expenditure, glucose and lipid oxidation, and the decreases in glycaemia and insulinemia were not altered by FO intake. Energy efficiency was 22.4+/-0.6% after FO vs 21.8+/-0.7% in controls. In order to ascertain that the absence of effects of FO was not due to consumption of a carbohydrate meal immediately before exercise, 4 of the 8 subjects were re-studied in fasting conditions, FO also failed to alter energy efficiency in this subset of studies. CONCLUSION: FO supplementation did not significantly alter energy metabolism and energy efficiency during exercise in healthy humans.
Resumo:
Introduction : Décrire les patients d'une structure gériatrique offrant des hospitalisations de courte durée, dans un contexte ambulatoire, pour des situations gériatriques courantes dans le canton de Genève (Suisse). Mesurer les performances de cette structure en termes de qualité des soins et de coûts. Méthodes : Des données relatives au profil des 100 premiers patients ont été collectées (huit mois), ainsi qu'aux prestations, aux ressources et aux effets (réadmissions, décès, satisfaction, complications) de manière à mesurer différents indicateurs de qualité et de coûts. Les valeurs observées ont été systématiquement comparées aux valeurs attendues, calculées à partir du profil des patients. Résultats : Des critères d'admission ont été fixés pour exclure les situations dans lesquelles d'autres structures offrent des soins mieux adaptés. La spécificité de cette structure intermédiaire a été d'assurer une continuité des soins et d'organiser d'emblée le retour à domicile par des prestations de liaison ambulatoire. La faible occurrence des réadmissions potentiellement évitables, une bonne satisfaction des patients, l'absence de décès prématurés et le faible nombre de complications suggèrent que les soins médicaux et infirmiers ont été délivrés avec une bonne qualité. Le coût s'est révélé nettement plus économique que des séjours hospitaliers après ajustement pour la lourdeur des cas. Conclusion : L'expérience-pilote a démontré la faisabilité et l'utilité d'une unité d'hébergement et d'hospitalisation de court séjour en toute sécurité. Le suivi du patient par le médecin traitant assure une continuité des soins et évite la perte d'information lors des transitions ainsi que les examens non pertinents. INTRODUCTION: To describe patients admitted to a geriatric institution, providing short-term hospitalizations in the context of ambulatory care in the canton of Geneva. To measure the performances of this structure in terms of quality ofcare and costs. METHOD: Data related to the clinical,functioning and participation profiles of the first 100 patients were collected. Data related to effects (readmission, deaths, satisfaction, complications), services and resources were also documented over an 8-month period to measure various quality and costindicators. Observed values were systematically compared to expected values, adjusted for case mix. RESULTS: Explicit criteria were proposed to focus on the suitable patients, excluding situations in which other structures were considered to be more appropriate. The specificity of this intermediate structure was to immediately organize, upon discharge, outpatient services at home. The low rate of potentially avoidable readmissions, the high patient satisfaction scores, the absence of premature death and the low number of iatrogenic complications suggest that medical and nursing care delivered reflect a good quality of services. The cost was significantly lower than expected, after adjusting for case mix. CONCLUSION: The pilot experience showed that a short-stay hospitalization unit was feasible with acceptable security conditions. The attending physician's knowledge of the patients allowed this system tofocus on essential issues without proposing inappropriate services.
Resumo:
The main purpose of this thesis is to measure and evaluate how accurately the current energy saving calculation in ABB’s new variable speed drive ACS850 works. The main topic of this thesis is energy-efficiency parameters. At the beginning of this thesis centrifugal pump, squirrel cage motor and variable speed drive, including some equations related to them, are being introduced. Also methods of throttling control and variable speed drive control of centrifugal pumps are being introduced. These subjects are introduced because the energy saving calculation in ACS850 is related to the centrifugal pumps usually driven by squirrel cage motors. The theory also includes short section about specific energy of pumping. Before measurements the current energy saving calculation of ACS850 is being introduced and analyzed. The measurements part includes introduction of measuring equipment, measurement results, summary and analysis of the measurements. At the end of this thesis a proposal for an improvement to the current energy saving calculation is being introduced and few proposals are made for new energy-efficiency parameters, which could be added to variable speed drives. At the end are also thoughts
Resumo:
This paper examines the extent to which innovative Spanish firms pursue improvements in energy efficiency (EE) as an objective of innovation. The increase in energy consumption and its impact on greenhouse gas emissions justifies the greater attention being paid to energy efficiency and especially to industrial EE. The ability of manufacturing companies to innovate and improve their EE has a substantial influence on attaining objectives regarding climate change mitigation. Despite the effort to design more efficient energy policies, the EE determinants in manufacturing firms have been little studied in the empirical literature. From an exhaustive sample of Spanish manufacturing firms and using a logit model, we examine the energy efficiency determinants for those firms that have innovated. To carry out the econometric analysis, we use panel data from the Community Innovation Survey for the period 2008‐2011. Our empirical results underline the role of size among the characteristics of firms that facilitate energy efficiency innovation. Regarding company behaviour, firms that consider the reduction of environmental impacts to be an important objective of innovation and that have introduced organisational innovations are more likely to innovate with the objective of increasing energy efficiency. Keywords: energy efficiency, corporate targets, innovation, Community Innovation Survey. JEL Classification: Q40, Q55, O31
Resumo:
The environmental impact of landfill is a growing concern in waste management practices. Thus, assessing the effectiveness of the solutions implemented to alter the issue is of importance. The objectives of the study were to provide an insight of landfill advantages, and to consolidate landfill gas importance among others alternative fuels. Finally, a case study examining the performances of energy production from a land disposal at Ylivieska was carried out to ascertain the viability of waste to energy project. Both qualitative and quantitative methods were applied. The study was conducted in two parts; the first was the review of literatures focused on landfill gas developments. Specific considerations were the conception of mechanism governing the variability of gas production and the investigation of mathematical models often used in landfill gas modeling. Furthermore, the analysis of two main distributed generation technologies used to generate energy from landfill was carried out. The review of literature revealed a high influence of waste segregation and high level of moisture content for waste stabilization process. It was found that the enhancement in accuracy for forecasting gas rate generation can be done with both mathematical modeling and field test measurements. The result of the case study mainly indicated the close dependence of the power output with the landfill gas quality and the fuel inlet pressure.
Resumo:
Energy efficiency and saving energy are the main question marks when thinking of reducing carbon dioxide emissions or cutting costs. The objective of thesis is to evaluate policy instruments concerning end-use energy efficiency of heavy industry in European Union. These policy instruments may be divided in various ways, but in this thesis the division is to administrative, financial, informative and voluntary instruments. Administrative instruments introduced in this thesis are Directive on Integrated Pollution Prevention and Control, Directive on Energy End-use Efficiency and Energy Services, and Climate and Energy Package. Financial means include energy and emission taxation, EU Emission Trading Scheme and diverse support systems. Informative instruments consist of horizontal BAT Reference Document for Energy Efficiency, as well as substantial EU documents including Green Paper on Energy Efficiency, Action Plan for Energy Efficiency and An Energy Policy for Europe. And finally, voluntary instruments include environmental managements systems like ISO 14001 and EMAS, energy auditing and benchmarking. The efficiency of different policy instruments vary quite a lot. Informative instruments lack the commitment from industry and are thus almost ineffective, contrary to EU Emission Trading Scheme, which is said to be the solution to climate problems. The efficiency of administrative means can be placed between those mentioned and voluntary instruments are still quite fresh to be examined fruitfully. However, each instrument has their potential and challenges. Cases from corporate world strengthen the results from theoretical part. Cases were written mainly on the basis of interviews. The interviewees praised the energy efficiency contract of Finnish industry, but the EU ETS takes the leading role of policy instruments. However, for industry the reductions do not come easily.
Resumo:
A coupled system simulator, based on analytical circuit equations and a finite element method (FEM) model of the motor has been developed and it is used to analyse a frequency-converterfed industrial squirrel-cage induction motor. Two control systems that emulate the behaviour of commercial direct-torque-controlled (DTC) and vector-controlled industrial frequency converters have been studied, implemented in the simulation software and verified by extensive laboratory tests. Numerous factors that affect the operation of a variable speed drive (VSD) and its energy efficiency have been investigated, and their significance in the simulation of the VSD results has been studied. The dependency of the frequency converter, induction motor and system losses on the switching frequency is investigated by simulations and measurements at different speeds for both the vector control and the DTC. Intensive laboratory measurements have been carried out to verify the simulation results.
Resumo:
The potential for enhancing the energy efficiency of industrial pumping processes is estimated to be in some cases up to 50 %. One way to define further this potential is to implement techniques in accordance to definition of best available techniques in pumping applications. These techniques are divided into three main categories: Design, control method & maintenance and distribution system. In the theory part of this thesis first the definition of best available techniques (BAT) and its applicability on pumping processes is issued. Next, the theory around pumping with different pump types is handled, the main stress being in centrifugal pumps. Other components needed in a pumping process are dealt by presenting different control methods, use of an electric motor, variable speed drive and the distribution system. Last part of the theory is about industrial pumping processes from water distribution, sewage water and power plant applications, some of which are used further on in the empirical part as example cases. For the empirical part of this study four case studies on typical pumping processes from older Master’s these were selected. Firstly the original results were analyzed by studying the distribution of energy consumption between different system components and using the definition of BAT in pumping, possible ways to improve energy efficiency were evaluated. The goal in this study was that by the achieved results it would be possible to identify the characteristic energy consumption of these and similar pumping processes. Through this data it would then be easier to focus energy efficiency actions where they might be the most applicable, both technically and economically.
Resumo:
Approximately a quarter of electrical power consumption in pulp and paper industry is used in different pumping systems. Therefore, improving pumping system efficiency is a considerable way to reduce energy consumption in different processes. Pumping of wood pulp in different consistencies is common in pulp and paper industry. Earlier, centrifugal pumps were used to pump pulp only at low consistencies, but development of MC technology has made it possible to pump medium consistency pulp. Pulp is a non-Newtonian fluid, which flow characteristics are significantly different than what of water. In this thesis is examined the energy efficiency of pumping medium consistency pulp with centrifugal pump. The factors effecting the pumping of MC pulp are presented and through case study is examined the energy efficiency of pumping in practice. With data obtained from the case study are evaluated the effects of pump rotational speed and pulp consistency on energy efficiency. Additionally, losses caused by control valve and validity of affinity laws in pulp pumping are evaluated. The results of this study can be used for demonstrating the energy consumption of MC pumping processes and finding ways to improve energy efficiency in these processes.
Resumo:
This study examined solution business models and how they could be applied into energy efficiency business. The target of this study was to find out, what a functional solution business model applied to energy efficiency improvement projects is like. The term “functionality” was used to refer not only to the economic viability but to environmental and legal aspects and also to the implement of Critical Success Factors (CSFs) and the ability to overcome the most important market barriers and risks. This thesis is based on a comprehensive literature study on solution business, business models and energy efficiency business. This literature review was used as a foundation to an energy efficiency solution business model scheme. The created scheme was tested in a case study which studied two different energy efficiency improvement projects, illustrated the functionality of the created business model and evaluated their potential as customer targets. Solution approach was found to be suitable for energy efficiency business. The most important characteristics of a good solution business model were identified to be the relationship between the supplier and customer, a proper network, knowledge on the customer’s process and supreme technological expertise. Thus the energy efficiency solution business was recognized to be particularly suitable for example for energy suppliers or technological equipment suppliers. Because the case study was not executed from a certain company’s point of view, the most important factors such as relationships and the availability of funding could not be evaluated. Although the energy efficiency business is recognized to be economically viable, the most important factors influencing the profitability and the success of energy efficiency solution business model were identified to be the proper risk management, the ability to overcome market barriers and the realization of CSFs.
Resumo:
Besides the sustaining of healthy and comfortable indoor climate, the air conditioning system should also achieve for energy efficiency. The target indoor climate can be ob-tained with different systems; this study focuses on comparing the energy efficiency of different air conditioning room unit systems in different climates. The calculations are made with dynamic energy simulation software IDA ICE by comparing the indoor cli-mate and energy consumption of an office building with different systems in different climates. The aim of the study is to compare the energy efficiency of chilled beam systems to other common systems: variable air volume, fan coil and radiant ceiling systems. Besides the annual energy consumption also the sustainability of target indoor climate is compared between the simulations. Another aim is to provide conclusions to be used in the product development of the chilled beam systems’ energy efficiency. The adaptable chilled beam system and the radiant ceiling system prove to be energy efficient independent of the climate. The challenge of reliable comparison is that other systems are not able to reach the target indoor climate as well as the others. The complex calculation environment of the simulation software, made assumptions and excluding of the financial aspects complicate comparing the big picture. The results show that the development of the chilled beam systems should concentrate on energy efficient night heating, flexible demand based ventilation and capacity control and possibilities on integrating the best practices with other systems.
Resumo:
The power demand of many mobile working machines such as mine loaders, straddle carriers and harvesters varies significantly during operation, and typically, the average power demand of a working machine is considerably lower than the demand for maximum power. Consequently, for most of the time, the diesel engine of a working machine operates at a poor efficiency far from its optimum efficiency range. However, the energy efficiency of dieseldriven working machines can be improved by electric hybridization. This way, the diesel engine can be dimensioned to operate within its optimum efficiency range, and the electric drive with its energy storages responds to changes in machine loading. A hybrid working machine can be implemented in many ways either as a parallel hybrid, a series hybrid or a combination of these two. The energy efficiency of hybrid working machines can be further enhanced by energy recovery and reuse. This doctoral thesis introduces the component models required in the simulation model of a working machine. Component efficiency maps are applied to the modelling; the efficiency maps for electrical machines are determined analytically in the whole torque–rotational speed plane based on the electricalmachine parameters. Furthermore, the thesis provides simulation models for parallel, series and parallel-series hybrid working machines. With these simulation models, the energy consumption of the working machine can be analysed. In addition, the hybridization process is introduced and described. The thesis provides a case example of the hybridization and dimensioning process of a working machine, starting from the work cycle of the machine. The selection and dimensioning of the hybrid system have a significant impact on the energy consumption of a hybrid working machine. The thesis compares the energy consumption of a working machine implemented by three different hybrid systems (parallel, series and parallel-series) and with different component dimensions. The payback time of a hybrid working machine and the energy storage lifetime are also estimated in the study.