215 resultados para Pacing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction : Insulation defects with externalized conductors have been reported in the St. Jude Riata(®) family of defibrillation leads (St. Jude Medical, Sylmar, CA, USA). The objective of the Northern Ireland Riata(®) lead screening program was to identify insulation defects and externalized conductors by systematic fluoroscopic and electrical assessment in a prospectively defined cohort of patients. We sought to estimate the prevalence, identify risk factors, and determine the natural history of this abnormality. Methods : All patients with a Riata(®) lead under follow-up at the Royal Victoria Hospital were invited for fluoroscopic imaging and implantable cardioverter-defibrillator lead parameter checks. Fluoroscopic images were read independently by two cardiologists and the presence of externalized conductors was classified as positive, negative, or borderline. Results: One hundred and sixty-five of 212 patients with a Riata lead were evaluated by fluoroscopy and lead parameter measurements. The mean duration after implantation was 3.98+/-1.43 years. After screening 25 (15%) patients were classified as positive, 137 (83%) negative, and three (1.8%) borderline. Time since implantation (P = 0.001), presence of a single coil lead (P = 0.042), and patient age (P = 0.034) were significantly associated with externalized conductors. The observed rate of externalized conductors was 26.9% for 8-French and 4.7% for 7-French leads. No leads that were identified prospectively with externalized conductors had electrical abnormalities. Seven of 25 (28%) patients had a defective lead extracted by the end of this screening period. Conclusion: A significant proportion (15%) of patients with a Riata lead had an insulation breach 4 years after implantation. High-resolution fluoroscopic imaging in at least two orthogonal views is required to identify this abnormality. (PACE 2012;35:1498-1504).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Laypersons are poor at emergency pulse checks (sensitivity 84%, specificity 36%). Guidelines indicate that pulse checks should not be performed. The impedance cardiogram (dZ/dt) is used to assess stroke volume. Can a novel defibrillator-based impedance cardiogram system be used to distinguish between circulatory arrest and other collapse states?

DESIGN: Animal study.

SETTING: University research laboratory.

SUBJECTS: Twenty anesthetized, mechanically ventilated pigs, weight 50-55 kg.

INTERVENTIONS: Stroke volume was altered by right ventricular pacing (160, 210, 260, and 305 beats/min). Cardiac arrest states were then induced: ventricular fibrillation (by rapid ventricular pacing) and, after successful defibrillation, pulseless electrical activity and asystole (by high-dose intravenous pentobarbitone).

MEASUREMENTS AND MAIN RESULTS: The impedance cardiogram was recorded through electrocardiogram/defibrillator pads in standard cardiac arrest positions. Simultaneously recorded electro- and impedance cardiogram (dZ/dt) along with arterial blood pressure tracings were digitized during each pacing and cardiac arrest protocol. Five-second epochs were analyzed for sinus rhythm (20 before ventricular fibrillation, 20 after successful defibrillation), ventricular fibrillation (40), pulseless electrical activity (20), and asystole (20), in two sets of ten pigs (ten training, ten validation). Standard impedance cardiogram variables were noncontributory in cardiac arrest, so the fast Fourier transform of dZ/dt was assessed. During ventricular pacing, the peak amplitude of fast Fourier transform of dZ/dt (between 1.5 and 4.5 Hz) correlated with stroke volume (r2 = .3, p < .001). In cardiac arrest, a peak amplitude of fast Fourier transform of dZ/dt of < or = 4 dB x ohm x rms indicated no output with high sensitivity (94% training set, 86% validation set) and specificity (98% training set, 90% validation set).

CONCLUSIONS: As a powerful clinical marker of circulatory collapse, the fast Fourier transformation of dZ/dt (impedance cardiogram) has the potential to improve emergency care by laypersons using automated defibrillators.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to describe the perceptions of Long Term Care (LTC) service providers in urban Canadian care facilities regarding the prevalence and nature of resident behavior problems and how staff manage these problems. Key informants from 15 LTC facilities housing 1,928 residents, participated in a cross sectional survey which employed semi-structured telephone interviews. Respondents estimated that on average 61% (n = 1,176) of residents had some type of mental health/behavioral problem, with facility estimates ranging from 20% to 90%. The most frequently reported problem behaviors included: general agitation and restlessness (36%); pacing and aimless wandering (28%); hoarding things (24%); hitting either self or others (23%); and verbal aggression (22%). Behaviors reported by respondents as "disruptive" or "very disruptive" were screaming (13%), sexual disinhibition (10%), and hitting either self or others (10%). The most common interventions used by staff were behavioral interventions followed by the use of medications. Low levels of staffing and educational training of staff were among the most common factors recognized as contributing to the difficulty in caring for residents with mental health needs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intermedin/adrenomedullin-2 (IMD) is a member of the adrenomedullin/CGRP peptide family. Less is known about the distribution of IMD than for other family members within the mammalian cardiovascular system, particularly in humans. The aim was to evaluate plasma IMD levels in healthy subjects and patients with chronic heart failure. IMD and its precursor fragments, preproIMD25–56 and preproIMD57–92, were measured by radioimmunoassay in 75 healthy subjects and levels of IMD were also compared to those of adrenomedullin (AM) and mid-region proadrenomedullin45–92 (MRproAM45–92) in 19 patients with systolic heart failure (LVEF < 45%). In healthy subjects, plasma levels (mean + SE) of IMD (6.3 + 0.6 pg ml−1) were lower than, but correlated with those of AM (25.8 + 1.8 pg ml−1; r = 0.49, p < 0.001). Plasma preproIMD25–56 (39.6 + 3.1 pg ml−1), preproIMD57–92 (25.9 + 3.8 pg ml−1) and MRproAM45–92 (200.2 + 6.7 pg ml−1) were greater than their respective bioactive peptides. IMD levels correlated positively with BMI but not age, and were elevated in heart failure (9.8 + 1.3 pg ml−1, p < 0.05), similarly to MRproAM45–92 (329.5 + 41.9 pg ml−1, p < 0.001) and AM (56.8 + 10.9 pg ml−1, p < 0.01). IMD levels were greater in heart failure patients with concomitant renal impairment (11.3 + 1.8 pg ml−1) than those without (6.5 + 1.0 pg ml−1; p < 0.05). IMD and AM were greater in patients receiving submaximal compared with maximal heart failure drug therapy and were decreased after 6 months of cardiac resynchronization therapy. In conclusion, IMD is present in the plasma of healthy subjects less abundantly than AM, but is similarly correlated weakly with BMI. IMD levels are elevated in heart failure, especially with concomitant renal impairment, and tend to be reduced by high intensity drug or pacing therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An infrequent but devastating late complication of Fontan circulation is protein-losing enteropathy (PLE), which results from unbalanced lymphatic homeostasis. Surgical decompression of the thoracic duct by redirecting its drainage to the pulmonary venous atrium has been introduced recently as a possible treatment. This report describes a single-institution experience with this innovative procedure in 2 patients with failing Fontan circulation with PLE refractory to optimized medical therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Up to 60% of syncopal episodes remain unexplained. We report the results of a standardized, stepwise evaluation of patients referred to an ambulatory clinic for unexplained syncope. METHODS AND RESULTS: We studied 939 consecutive patients referred for unexplained syncope, who underwent a standardized evaluation, including history, physical examination, electrocardiogram, head-up tilt testing (HUTT), carotid sinus massage (CSM) and hyperventilation testing (HYV). Echocardiogram and stress test were performed when underlying heart disease was initially suspected. Electrophysiological study (EPS) and implantable loop recorder (ILR) were used only in patients with underlying structural heart disease or major unexplained syncope. We identified a cause of syncope in 66% of patients, including 27% vasovagal, 14% psychogenic, 6% arrhythmias, and 6% hypotension. Noninvasive testing identified 92% and invasive testing an additional 8% of the causes. HUTT yielded 38%, CSM 28%, HYV 49%, EPS 22%, and ILR 56% of diagnoses. On average, patients with arrhythmic causes were older, had a lower functional capacity, longer P-wave duration, and presented with fewer prodromes than patients with vasovagal or psychogenic syncope. CONCLUSIONS: A standardized stepwise evaluation emphasizing noninvasive tests yielded 2/3 of causes in patients referred to an ambulatory clinic for unexplained syncope. Neurally mediated and psychogenic mechanisms were behind >50% of episodes, while cardiac arrhythmias were uncommon. Sudden syncope, particularly in older patients with functional limitations or a prolonged P-wave, suggests an arrhythmic cause.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Catecholaminergic polymorphic ventricular tachycardia (CPVT) is an arrhythmogenic disease for which electrophysiological studies (EPS) have shown to be of limited value.OBJECTIVE This study presents a CPVT family in which marked postpacing repolarization abnormalities during EPS were the only consistent phenotypic manifestation of ryanodine receptor (RyR2) mutation carriers.METHODS The study was prompted by the observation of transient marked QT prolongation preceding initiation of ventricular fibrillation during atrial fibrillation in a boy with a family history of sudden cardiac death (SCD). Family members underwent exercise and pharmacologic electrocardiographic testing with epinephrine, adenosine, and flecainide. Noninvasive clinical test results were normal in 10 patients evaluated, except for both epinephrine- and exercise-induced ventricular arrhythmias in 1. EPS included bursts of ventricular pacing and programmed ventricular extrastimulation reproducing short-long sequences. Genetic screening involved direct sequencing of genes involved in long QT syndrome as well as RyR2.RESULTS Six patients demonstrated a marked increase in QT interval only in the first beat after cessation of ventricular pacing and/or extrastimulation. All 6 patients were found to have a heterozygous missense mutation (M4109R) in RyR2. Two of them, presenting with aborted SCD, also had a second missense mutation (I406T- RyR2). Four family members without RyR2 mutations did not display prominent postpacing QT changes.CONCLUSION M4109R- RyR2 is associated with a high incidence of SCD. The contribution of I406T to the clinical phenotype is unclear. In contrast to exercise testing, marked postpacing repolarization changes in a single beat accurately predicted carriers of M4109R- RyR2 in this family.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This exploratory descriptive study described what 20 care providers in 5 long-term care facilities perceived to aid or hinder their learning in a work-sponsored learning experience. A Critical Incident Technique (Woolsey, 1986) was the catalyst for the interviews with the culturally and professionally diverse participants. Through data analysis, as described by Moustakas (1994), I found that (a) humour, (b) the learning environment, (c) specific characteristics of the presenter such as moderate pacing, speaking slowly and with simple words, (d) decision-making authority, (e) relevance to practice, and (f) practical applications best met the study participants' learning needs. Conversely, other factors could hinder learning based on the participants' perceptions. These were: (a) other presenter characteristics such as a program that was delivered quickly or spoken at a level above the participants' comprehension, (b) no perceived relevance to practice, (c), other environmental situations, and (d) the timing of the learning session. One of my intentions was to identify the emic view among cultural groups and professional/vocational affiliations. A surprising finding of this study was that neither impacted noticeably on the perceived learning needs of the participants. Further research with a revised research design to facilitate inclusion of more diverse participants will aid in determining if the lack of a difference was unique to this sample or more generalizable on a case-to-case transfer basis to the study population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La thérapie de resynchronisation cardiaque (CRT) est un traitement qui diminue la mortalité et améliore la qualité de vie des patients atteints d’insuffisance cardiaque et présentant un dyssynchronisme de la contraction ventriculaire gauche. Malgré le succès de cette thérapie, plus de 30% des patients ne présentent pas l’amélioration désirée. Plusieurs études portant sur le synchronisme électrique ou mécanique de la contraction ont été effectuées mais peu d’entres elles se sont attardées sur le couplage électromécanique à l'échelle macroscopique. Ce projet a comme objectif d’observer le comportement électromécanique des ventricules canins en présence d’un resynchronisateur cardiaque. Un logiciel a été développé pour permettre l’analyse des informations provenant de la cartographie endocardique sans contact et de la ventriculographie isotopique tomographique chez 12 sujets canins insuffisants. Pour observer la réponse mécanique suite à l’activation électrique, nous avons premièrement recalé les surfaces issues des 2 modalités. Ensuite, nous avons défini les limites du cycle cardiaque, analysé les signaux électriques et les courbes de déplacement de la paroi endocardique. Le début de la contraction est défini par un déplacement radial de 10% vers le centre du ventricule. Les résultats démontrent que la durée d’activation du ventricule gauche et la largeur du QRS augmentent en présence d’une stimulation externe et que les délais électromécaniques sont indépendants dans les modes de stimulation étudiés (sinusal, LVbasal, RVapex ou BIV) avec une moyenne de 84,56±7,19 ms. Finalement, nous avons noté que la stimulation basolatérale procure une fonction cardiaque optimale malgré une durée prolongée du QRS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La fibrillation auriculaire, l'arythmie la plus fréquente en clinique, affecte 2.3 millions de patients en Amérique du Nord. Pour en étudier les mécanismes et les thérapies potentielles, des modèles animaux de fibrillation auriculaire ont été développés. La cartographie électrique épicardique à haute densité est une technique expérimentale bien établie pour suivre in vivo l'activité des oreillettes en réponse à une stimulation électrique, à du remodelage, à des arythmies ou à une modulation du système nerveux autonome. Dans les régions qui ne sont pas accessibles par cartographie épicardique, la cartographie endocardique sans contact réalisée à l'aide d'un cathéter en forme de ballon pourrait apporter une description plus complète de l'activité auriculaire. Dans cette étude, une expérience chez le chien a été conçue et analysée. Une reconstruction électro-anatomique, une cartographie épicardique (103 électrodes), une cartographie endocardique sans contact (2048 électrodes virtuelles calculées à partir un cathéter en forme de ballon avec 64 canaux) et des enregistrements endocardiques avec contact direct ont été réalisés simultanément. Les systèmes d'enregistrement ont été également simulés dans un modèle mathématique d'une oreillette droite de chien. Dans les simulations et les expériences (après la suppression du nœud atrio-ventriculaire), des cartes d'activation ont été calculées pendant le rythme sinusal. La repolarisation a été évaluée en mesurant l'aire sous l'onde T auriculaire (ATa) qui est un marqueur de gradient de repolarisation. Les résultats montrent un coefficient de corrélation épicardique-endocardique de 0.8 (expérience) and 0.96 (simulation) entre les cartes d'activation, et un coefficient de corrélation de 0.57 (expérience) and 0.92 (simulation) entre les valeurs de ATa. La cartographie endocardique sans contact apparait comme un instrument expérimental utile pour extraire de l'information en dehors des régions couvertes par les plaques d'enregistrement épicardique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La posible asociación entre el desarrollo de fibrilación auricular (FA) con la presencia de cardiopatía chagásica en una población portadora de dispositivos cardiacos de estimulación no está descrita. Se presenta un estudio de tipo cohorte retrospectivo realizado en la FCI que recopila las principales características clínicas de una población de pacientes con cardiopatía de variada etiología y portadores de dispositivos cardiacos buscando evaluar la incidencia de FA en presencia de cardiomiopatía de origen chagásico y no chagásico. A la fecha no se cuenta con una base de datos institucional ni regional que contenga las variables analizadas. Durante los 5 meses que duró la construcción de la base de datos se incluyeron 99 sujetos de investigación. Se implantaron 42 marcapasos bicamerales, 39 cardiodesfibriladores bicamerales, 6 dispositivos correspondientes cardiodesfibrilador con función de resincronización cardiaca, 2 resincronizadores cardiacos sin función de cardiodesfibrilador y 7 cardiodesfibriladores unicamerales. De los 99 sujetos recolectados se presentaron 8 desenlaces (FA de novo) y de esos solamente 1 pertenece al grupo de pacientes con cardiomiopatía chagásica. Este número reducido de desenlaces no permitió desarrollar un modelo de regresión de Cox y ni otros tipos de análisis estadísticos planteados en el protocolo inicial debido al bajo número de casos y pobre poder estadístico. Esta dificultad es inherente a la naturaleza del problema a estudiar y al corto tiempo de seguimiento. Por lo anterior no se puede establecer si existe una relación entre la presencia de serología positiva para infección por T. Cruzi y la presencia de FA de novo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: El síncope es un motivo frecuente de consulta en Urgencias, definir el estudio y el destino de estos pacientes es motivo de controversia. Se han diseñado varias escalas para estratificación del riesgo en pacientes con esta entidad. En este estudio se comparan las características operativas de 4 escalas para la decisión de hospitalizar pacientes con síncope que consultan a un servicio de urgencias de una institución de III y IV Nivel Métodos. Estudio analítico transversal, en el que se aplicaron las 4 escalas de riesgo a pacientes que consultaron por síncope al servicio de Urgencias durante un período de 6 meses y que fueron hospitalizados en la institución donde se realizó. Se evaluaron los resultados aplicando el programa Epidat 3.1 para sensibilidad y especificidad, índice de Youden. Resultados. Se incluyeron en total 91 pacientes. La sensibilidad de las escalas San Francisco, OESIL, EGSYS y la institucional para el requerimiento de hospitalización fue de 79%, 87%. 63% y 95% respectivamente y la especificidad fue de 52%, 40%, 64% y 14%. EL riesgo de mortalidad no fue adecuadamente detectado por la escala de San Francisco.. Conclusiones. Ninguna de las escalas aplicadas a los pacientes hospitalizados que consultaron por síncope a urgencias superó el juicio clínico para definir la hospitalización. Sin embargo, la escala OESIL y la institucional pueden ayudar a corroborar la decisión clínica de hospitalizar en esta población.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Determinar la incidencia de fibrilación auricular en las primeras 72 horas del post operatorio en pacientes llevados a revascularización miocárdica utilizando dos técnicas de anestésia una convencional (AC) con anestésicos inhalados y opioides y otra con dexmedetomidina (AD.). cohorte retrospectivo, en donde se seleccionarán dos grupos de estudio, un grupo de expuestos, pacientes llevados a revascularización miocárdica con utilización técnica anestésica convencional y un grupo de no expuestos pacientes llevados a revascularización miocárdica con uso de dexmedetomidina como técnica de anestesia; A estos grupos se les hizo seguimiento por 72 horas para determinar la presencia de fibrilación auricular y la terapéutica instaurada.