126 resultados para Miyazaki
Resumo:
INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
OBJECTIVES Chewing efficiency may be evaluated using cohesive specimen, especially in elderly or dysphagic patients. The aim of this study was to evaluate three two-coloured chewing gums for a colour-mixing ability test and to validate a new purpose built software (ViewGum©). METHODS Dentate participants (dentate-group) and edentulous patients with mandibular two-implant overdentures (IOD-group) were recruited. First, the dentate-group chewed three different types of two-coloured gum (gum1-gum3) for 5, 10, 20, 30 and 50 chewing cycles. Subsequently the number of chewing cycles with the highest intra- and inter-rater agreement was determined visually by applying a scale (SA) and opto-electronically (ViewGum©, Bland-Altman analysis). The ViewGum© software determines semi-automatically the variance of hue (VOH); inadequate mixing presents with larger VOH than complete mixing. Secondly, the dentate-group and the IOD-group were compared. RESULTS The dentate-group comprised 20 participants (10 female, 30.3±6.7 years); the IOD-group 15 participants (10 female, 74.6±8.3 years). Intra-rater and inter-rater agreement (SA) was very high at 20 chewing cycles (95.00-98.75%). Gums 1-3 showed different colour-mixing characteristics as a function of chewing cycles, gum1 showed a logarithmic association; gum2 and gum3 demonstrated more linear behaviours. However, the number of chewing cycles could be predicted in all specimens from VOH (all p<0.0001, mixed linear regression models). Both analyses proved discriminative to the dental state. CONCLUSION ViewGum© proved to be a reliable and discriminative tool to opto-electronically assess chewing efficiency, given an elastic specimen is chewed for 20 cycles and could be recommended for the evaluation of chewing efficiency in a clinical and research setting. CLINICAL SIGNIFICANCE Chewing is a complex function of the oro-facial structures and the central nervous system. The application of the proposed assessments of the chewing function in geriatrics or special care dentistry could help visualising oro-functional or dental comorbidities in dysphagic patients or those suffering from protein-energy malnutrition.
Resumo:
While modern sampling techniques, such as autonomous underwater vehicles, are increasing our knowledge of the fauna beneath Antarctic sea ice of only a few meters in depth, greater sampling difficulties mean that little is known about the marine life underneath Antarctic ice shelves over 100 m thick. In this study, we present underwater images showing the underside of an Antarctic ice shelf covered by aggregated invertebrate communities, most likely cnidarians and isopods. These images, taken at an average depth of 145 m, were obtained with a digital still camera system attached to Weddell seals Leptonychotes weddellii foraging just beneath the ice shelf. Our observations indicate that, similar to the sea floor, ice shelves serve as an important habitat for a remarkable amount of marine invertebrate fauna in Antarctica.
Resumo:
The agreement was reached at a ministerial level * to promote EU-Japan cooperation in the field of energy-related technologies. *the Minister of Economy, Trade and Industry of Japan and the EU Commissioner for Science and Research
Resumo:
Si Nanowires (NWs) were studied by Raman microspectroscopy. The Raman spectrum of the NWs reveals important thermal effects, which broaden and shift the one phonon Raman bands. The low thermal conductivity of the NWs and the low thermal dissipation are responsible for the temperature enhancement in the NW under the excitation with the laser beam. We have modeled, using finite element methods, the interaction between the laser beam and the NWs. The Raman spectrum of Si NWs is interpreted in terms of the temperature induced by the laser beam excitation, in correlation with finite element methods (fem) for studying the interaction between the laser beam and the NWs.
Resumo:
A method based on experimental data is proposed to optimize the energy harvesting of a silicone-on-glass Fresnel-lens based CPV system. It takes into account the spectral variations along the year in a particular location as well as the thermal and spectral sensitivities of the optics and solar cell. In addition, different alternatives to tune the top/middle subcells current ratio in a CPV module are analyzed and their capacity to maximize the annually produced energy is quantified.
Resumo:
A temperature accelerated life test on commercial concentrator lattice-matched GaInP/GaInAs/Ge triple-junction solar cells has been carried out. The solar cells have been tested at three different temperatures: 119, 126 and 164 °C and the nominal photo-current condition (820 X) has been emulated by injecting current in darkness. All the solar cells have presented catastrophic failures. The failure distributions at the three tested temperatures have been fitted to an Arrhenius-Weibull model. An Arrhenius activation energy of 1.58 eV was determined from the fit. The main reliability functions and parameters (reliability function, instantaneous failure rate, mean time to failure, warranty time) of these solar cells at the nominal working temperature (80 °C) have been obtained. The warranty time obtained for a failure population of 5 % has been 69 years. Thus, a long-term warranty could be offered for these particular solar cells working at 820 X, 8 hours per day at 80 °C.
Resumo:
Most CPV systems are based on Fresnel lenses. Among these, LPI-patented Fresnel-Köhler (FK) concentrator outstands owing to performance and practical reasons. The VentanaTM power train is the first off-the-shelf commercial product based on the FK and comprises both the primary (POE) lenses (a 36-units 1×1 m2 acrylic panel manufactured by EVONIK and 10×) and glass (or Savosil) secondary optics (SOE). This high concentration optical train (Cg=1,024×, ~250mm optical depth) fits with 5×5 mm2 (at least) solar cells. The optical train is the fruit of a 1-year development that has included design, modeling, prototyping and characterization, and through the process LPI had the opportunity to find out how well the actual performance correlates with models, but also learned practical aspects of a CPV system of this kind, some of which have very positive impact on system performance and reliability.
Resumo:
Tiny increases in the transmittance of optical materials within a CPV module can have an important impact on the economy of a plant. This is certainly true in systems comprising multi-junction solar cells, whose high performance, based on a balanced photocurrent generation among the series-connected junctions, is very sensitive to spectrum variations. Every efficiency point gained causes not only an increase in the kilowatts hour produced, but a higher benefit on it, since the difference between electricity tariff and Levelized Cost of Electricity (LCOE) rises. This work studies the impact on the LCOE of a plant based on modules comprising PMMA lenses of two different types, standard UV blocking grade which is normally used for outdoor applications at high DNI climate and a specialty stabilized UV-enhanced transmittance acrylic (see Figure 1). Energy production will be compared for these two systems throughout the year at different sites to analyze when (season, time of the day) and where the usage of the enhanced PMMA is justified.
Resumo:
The FK concentrator has demonstrated during the last years that compares very well with other Fresnel-based concentrator optics for CPV. There are several features that provide the FK high performance: (1) high optical efficiency; (2) large tolerance to tracking misalignment and manufacturing errors, thanks to a high CAP (Concentration-Acceptance Product); (3) good irradiance uniformity and low chromatic dispersion on the cell surface. Non-uniformities in terms of absolute irradiance and spectral content produced by conventional CPV systems can originate electrical losses in multi-junction (MJ) solar cells. The aim of this work is to analyze the influence of these non-uniformities in the FK concentrator performance and how FK concentrator provides high electrical efficiencies thanks to its insensitivity to chromatic aberrations, especially when components move away from the module nominal position due to manufacturing misalignments. This analysis has been done here by means of both, experimental on-sun measurements and simulations based on 3D fully distributed circuit model for MJ cells.
Resumo:
In high quality solar cells, the internal luminescence can be harnessed to enhance the overall performance. Internal confinement of the photons can lead to an increased open-circuit voltage and short-circuit current. Alternatively, in multijunction solar cells the photons can be coupled from a higher bandgap junction to a lower bandgap junction for enhanced performance. We model the solar cell as an optical cavity and compare calculated performance characteristics with measurements. We also describe how very high luminescent coupling alleviates the need for top-cell thinning to achieve current-matching.
Resumo:
This paper presents the design and preliminary experimental results of a concentrator-type photovoltaic module based on a free-form off-axis 800×XR-Köhler concentrator. The off-axis XR-Köhler concentrator is one of the advanced concentrators that perform high concentration with a large acceptance angle and excellent irradiance uniformity on a solar cell. As a result of on-sun characterization of the unglazed single-cell unit test rig, the temperature-corrected DC module efficiency was 32.2% at 25 °C without an anti-reflective (AR) coating on the secondary optics, and the acceptance angle was more than ±1.0°. In addition, the non-corrected DC efficiency of an individual cell in a glazed 8-cell unit module mounted on a carousel tracking system was measured. The individual efficiency deviated in the range of 24.3-27.4%, owing to the mirror shape and alignment errors. The resultant series-connected efficiency was approximately 25% at direct normal irradiation (DNI) of 770 W/m2.