Evaluation of the reliability of commercial concentrator triple-junction solar cells by means of accelerated life tests (ALT)


Autoria(s): Espinet González, Pilar; Algora del Valle, Carlos; Nuñez Mendoza, Neftali; Orlando Carrillo, Vincenzo; Vázquez López, Manuel; Bautista Villares, Jesus; Araki, Kenji
Data(s)

2013

Resumo

A temperature accelerated life test on commercial concentrator lattice-matched GaInP/GaInAs/Ge triple-junction solar cells has been carried out. The solar cells have been tested at three different temperatures: 119, 126 and 164 °C and the nominal photo-current condition (820 X) has been emulated by injecting current in darkness. All the solar cells have presented catastrophic failures. The failure distributions at the three tested temperatures have been fitted to an Arrhenius-Weibull model. An Arrhenius activation energy of 1.58 eV was determined from the fit. The main reliability functions and parameters (reliability function, instantaneous failure rate, mean time to failure, warranty time) of these solar cells at the nominal working temperature (80 °C) have been obtained. The warranty time obtained for a failure population of 5 % has been 69 years. Thus, a long-term warranty could be offered for these particular solar cells working at 820 X, 8 hours per day at 80 °C.

Formato

application/pdf

Identificador

http://oa.upm.es/26156/

Idioma(s)

eng

Relação

http://oa.upm.es/26156/1/INVE_MEM_2013_162997.pdf

http://dx.doi.org/10.1063/1.4822236

info:eu-repo/semantics/altIdentifier/doi/10.1063/1.4822236

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

AIP Conference Proceedings | 9th International Conference on Concentrator Photovoltaic Systems | 15/04/2013 - 17/04/2013 | Miyazaki, Japan

Palavras-Chave #Telecomunicaciones #Energías Renovables
Tipo

info:eu-repo/semantics/conferenceObject

Ponencia en Congreso o Jornada

PeerReviewed