991 resultados para Microscopy technique


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Digital holography microscopy (DHM) is an optical technique which provides phase images yielding quantitative information about cell structure and cellular dynamics. Furthermore, the quantitative phase images allow the derivation of other parameters, including dry mass production, density, and spatial distribution. We have applied DHM to study the dry mass production rate and the dry mass surface density in wild-type and mutant fission yeast cells. Our study demonstrates the applicability of DHM as a tool for label-free quantitative analysis of the cell cycle and opens the possibility for its use in high-throughput screening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

By means of confocal laser scanning microscopy and indirect fluorescence experiments we have examined the behavior of heat-shock protein 70 (HSP70) within the nucleus as well as of a nuclear matrix protein (M(r) = 125 kDa) during a prolonged heat-shock response (up to 24 h at 42 degrees C) in HeLa cells. In control cells HSP70 was mainly located in the cytoplasm. The protein translocated within the nucleus upon cell exposure to hyperthermia. The fluorescent pattern revealed by monoclonal antibody to HSP70 exhibited several changes during the 24-h-long incubation. The nuclear matrix protein showed changes in its location that were evident as early as 1 h after initiation of heat shock. After 7 h of treatment, the protein regained its original distribution. However, in the late stages of the hyperthermic treatment (17-24 h) the fluorescent pattern due to 125-kDa protein changed again and its original distribution was never observed again. These results show that HSP70 changes its localization within the nucleus conceivably because it is involved in solubilizing aggregated polypeptides present in different nuclear regions. Our data also strengthen the contention that proteins of the insoluble nucleoskeleton are involved in nuclear structure changes that occur during heat-shock response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we demonstrate that conductive atomic force microscopy (C-AFM) is a very powerful tool to investigate, at the nanoscale, metal-oxide-semiconductor structures with silicon nanocrystals (Si-nc) embedded in the gate oxide as memory devices. The high lateral resolution of this technique allows us to study extremely small areas ( ~ 300nm2) and, therefore, the electrical properties of a reduced number of Si-nc. C-AFM experiments have demonstrated that Si-nc enhance the gate oxide electrical conduction due to trap-assisted tunneling. On the other hand, Si-nc can act as trapping centers. The amount of charge stored in Si-nc has been estimated through the change induced in the barrier height measured from the I-V characteristics. The results show that only ~ 20% of the Si-nc are charged, demonstrating that the electrical behavior at the nanoscale is consistent with the macroscopic characterization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Red blood cell (RBC) membrane fluctuations provide important insights into cell states. We present a spatial analysis of red blood cell membrane fluctuations by using digital holographic microscopy (DHM). This interferometric and dye-free technique, possessing nanometric axial and microsecond temporal sensitivities enables to measure cell membrane fluctuations (CMF) on the whole cell surface. DHM acquisition is combined with a model which allows extracting the membrane fluctuation amplitude, while taking into account cell membrane topology. Uneven distribution of CMF amplitudes over the RBC surface is observed, showing maximal values in a ring corresponding to the highest points on the RBC torus as well as in some scattered areas in the inner region of the RBC. CMF amplitudes of 35.9+/-8.9 nm and 4.7+/-0.5 nm (averaged over the cell surface) were determined for normal and ethanol-fixed RBCs, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The determination of line crossing sequences between rollerball pens and laser printers presents difficulties that may not be overcome using traditional techniques. This research aimed to study the potential of digital microscopy and 3-D laser profilometry to determine line crossing sequences between a toner and an aqueous ink line. Different paper types, rollerball pens, and writing pressure were tested. Correct opinions of the sequence were given for all case scenarios, using both techniques. When the toner was printed before the ink, a light reflection was observed in all crossing specimens, while this was never observed in the other sequence types. The 3-D laser profilometry, more time-consuming, presented the main advantage of providing quantitative results. The findings confirm the potential of the 3-D laser profilometry and demonstrate the efficiency of digital microscopy as a new technique for determining the sequence of line crossings involving rollerball pen ink and toner. With the mass marketing of laser printers and the popularity of rollerball pens, the determination of line crossing sequences between such instruments is encountered by forensic document examiners. This type of crossing presents difficulties with optical microscopic line crossing techniques involving ballpoint pens or gel pens and toner (1-4). Indeed, the rollerball's aqueous ink penetrates through the toner and is absorbed by the fibers of the paper, leaving the examiner with the impression that the toner is above the ink even when it is not (5). Novotny and Westwood (3) investigated the possibility of determining aqueous ink and toner crossing sequences by microscopic observation of the intersection before and after toner removal. A major disadvantage of their study resides in destruction of the sample by scraping off the toner line to see what was underneath. The aim of this research was to investigate the ways to overcome these difficulties through digital microscopy and three-dimensional (3-D) laser profilometry. The former was used as a technique for the determination of sequences between gel pen and toner printing strokes, but provided less conclusive results than that of an optical stereomicroscope (4). 3-D laser profilometry, which allows one to observe and measure the topography of a surface, has been the subject of a number of recent studies in this area. Berx and De Kinder (6) and Schirripa Spagnolo (7,8) have tested the application of laser profilometry to determine the sequence of intersections of several lines. The results obtained in these studies overcome disadvantages of other methods applied in this area, such as scanning electron microscope or the atomic force microscope. The main advantages of 3-D laser profilometry include the ease of implementation of the technique and its nondestructive nature, which does not require sample preparation (8-10). Moreover, the technique is reproducible and presents a high degree of freedom in the vertical axes (up to 1000 μm). However, when the paper surface presents a given roughness, if the pen impressions alter the paper with a depth similar to the roughness of medium, the results are not always conclusive (8). It becomes difficult in this case to distinguish which characteristics can be imputed to the pen impressions or the quality of the paper surface. This important limitation is assessed by testing different types of paper of variable quality (of different grammage and finishing) and the writing pressure. The authors will therefore assess the limits of 3-D laser profilometry technique and determine whether the method can overcome such constraints. Second, the authors will investigate the use of digital microscopy because it presents a number of advantages: it is efficient, user-friendly, and provides an objective evaluation and interpretation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cell-wall mechanical properties play a key role in the growth and the protection of plants. However, little is known about genuine wall mechanical properties and their growth-related dynamics at subcellular resolution and in living cells. Here, we used atomic force microscopy (AFM) stiffness tomography to explore stiffness distribution in the cell wall of suspension-cultured Arabidopsis thaliana as a model of primary, growing cell wall. For the first time that we know of, this new imaging technique was performed on living single cells of a higher plant, permitting monitoring of the stiffness distribution in cell-wall layers as a function of the depth and its evolution during the different growth phases. The mechanical measurements were correlated with changes in the composition of the cell wall, which were revealed by Fourier-transform infrared (FTIR) spectroscopy. In the beginning and end of cell growth, the average stiffness of the cell wall was low and the wall was mechanically homogenous, whereas in the exponential growth phase, the average wall stiffness increased, with increasing heterogeneity. In this phase, the difference between the superficial and deep wall stiffness was highest. FTIR spectra revealed a relative increase in the polysaccharide/lignin content.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transmission electron microscopy is a proven technique in the field of cell biology and a very useful tool in biomedical research. Innovation and improvements in equipment together with the introduction of new technology have allowed us to improve our knowledge of biological tissues, to visualizestructures better and both to identify and to locate molecules. Of all the types ofmicroscopy exploited to date, electron microscopy is the one with the mostadvantageous resolution limit and therefore it is a very efficient technique fordeciphering the cell architecture and relating it to function. This chapter aims toprovide an overview of the most important techniques that we can apply to abiological sample, tissue or cells, to observe it with an electron microscope, fromthe most conventional to the latest generation. Processes and concepts aredefined, and the advantages and disadvantages of each technique are assessedalong with the image and information that we can obtain by using each one ofthem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atomic Force Microscope and related techniques have played a key role in the development of the nanotechnology revolution that is taking place in science. This paper reviews the basic principles behind the technique and its different operation modes and applications, pointing out research worksperformed in the Nanometric Techniques Unit of the CCiTUB in order to exemplify the vast array of capabilities of these instruments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article summarizes the basic principles of scanning electron microscopy and the capabilities of the technique with different examples ofapplications in biomedical and biological research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Photodynamic therapy (PDT) with Visudyne acts by direct cellular phototoxicity and/or by an indirect vascular-mediated effect. Here, we demonstrate that the vessel integrity interruption by PDT can promote the extravasation of a macromolecular agent in normal tissue. To obtain extravasation in normal tissue PDT conditions were one order of magnitude more intensive than the ones in tissue containing neovessels reported in the literature. Fluorescein isothiocyanate dextran (FITC-D, 2000 kDa), a macromolecular agent, was intravenously injected 10 min before (LK0 group, n=14) or 2h (LK2 group, n=16) after Visudyne-mediated PDT in nude mice bearing a dorsal skin fold chamber. Control animals had no PDT (CTRL group, n=8). The extravasation of FITC-D from blood vessels in striated muscle tissue was observed in both groups in real-time for up to 2500 s after injection. We also monitored PDT-induced leukocyte rolling in vivo and assessed, by histology, the corresponding inflammatory reaction score in the dorsal skin fold chambers. In all animals, at the applied PDT conditions, FITC-D extravasation was significantly enhanced in the PDT-treated areas as compared to the surrounding non-treated areas (p<0.0001). There was no FITC-D leakage in the control animals. Animals from the LK0 group had significantly less FITC-D extravasation than those from the LK2 group (p=0.0002). In the LK0 group FITC-D leakage correlated significantly with the inflammation (p<0.001). At the selected conditions, Visudyne-mediated PDT promotes vascular leakage and FITC-D extravasation into the interstitial space of normal tissue. The intensity of vascular leakage depends on the time interval between PDT and FITC-D injection. This concept could be used to locally modulate the delivery of macromolecules in vivo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The atomic force microscope is a convenient tool to probe living samples at the nanometric scale. Among its numerous capabilities, the instrument can be operated as a nano-indenter to gather information about the mechanical properties of the sample. In this operating mode, the deformation of the cantilever is displayed as a function of the indentation depth of the tip into the sample. Fitting this curve with different theoretical models permits us to estimate the Young's modulus of the sample at the indentation spot. We describe what to our knowledge is a new technique to process these curves to distinguish structures of different stiffness buried into the bulk of the sample. The working principle of this new imaging technique has been verified by finite element models and successfully applied to living cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this review, we summarize how the new concept of digital optics applied to the field of holographic microscopy has allowed the development of a reliable and flexible digital holographic quantitative phase microscopy (DH-QPM) technique at the nanoscale particularly suitable for cell imaging. Particular emphasis is placed on the original biological information provided by the quantitative phase signal. We present the most relevant DH-QPM applications in the field of cell biology, including automated cell counts, recognition, classification, three-dimensional tracking, discrimination between physiological and pathophysiological states, and the study of cell membrane fluctuations at the nanoscale. In the last part, original results show how DH-QPM can address two important issues in the field of neurobiology, namely, multiple-site optical recording of neuronal activity and noninvasive visualization of dendritic spine dynamics resulting from a full digital holographic microscopy tomographic approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last two decades, Atomic Force Microscopy (AFM) has emerged as the tool of choice to image living organisms in a near-physiological environment. Whereas fluorescence microscopy techniques allow labeling and tracking of components inside cells and the observation of dynamic processes, AFM is mainly a surface technique that can be operated on a wide range of substrates including biological samples. AFM enables extraction of topographical, mechanical and chemical information from these samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé L'eau est souvent considérée comme une substance ordinaire puisque elle est très commune dans la nature. En fait elle est la plus remarquable de toutes les substances. Sans l'eau la vie sur la terre n'existerait pas. L'eau représente le composant majeur de la cellule vivante, formant typiquement 70 à 95% de la masse cellulaire et elle fournit un environnement à d'innombrables organismes puisque elle couvre 75% de la surface de terre. L'eau est une molécule simple faite de deux atomes d'hydrogène et un atome d'oxygène. Sa petite taille semble en contradiction avec la subtilité de ses propriétés physiques et chimiques. Parmi celles-là, le fait que, au point triple, l'eau liquide est plus dense que la glace est particulièrement remarquable. Malgré son importance particulière dans les sciences de la vie, l'eau est systématiquement éliminée des spécimens biologiques examinés par la microscopie électronique. La raison en est que le haut vide du microscope électronique exige que le spécimen biologique soit solide. Pendant 50 ans la science de la microscopie électronique a adressé ce problème résultant en ce moment en des nombreuses techniques de préparation dont l'usage est courrant. Typiquement ces techniques consistent à fixer l'échantillon (chimiquement ou par congélation), remplacer son contenu d'eau par un plastique doux qui est transformé à un bloc rigide par polymérisation. Le bloc du spécimen est coupé en sections minces (d’environ 50 nm) avec un ultramicrotome à température ambiante. En général, ces techniques introduisent plusieurs artefacts, principalement dû à l'enlèvement d'eau. Afin d'éviter ces artefacts, le spécimen peut être congelé, coupé et observé à basse température. Cependant, l'eau liquide cristallise lors de la congélation, résultant en une importante détérioration. Idéalement, l'eau liquide est solidifiée dans un état vitreux. La vitrification consiste à refroidir l'eau si rapidement que les cristaux de glace n'ont pas de temps de se former. Une percée a eu lieu quand la vitrification d'eau pure a été découverte expérimentalement. Cette découverte a ouvert la voie à la cryo-microscopie des suspensions biologiques en film mince vitrifié. Nous avons travaillé pour étendre la technique aux spécimens épais. Pour ce faire les échantillons biologiques doivent être vitrifiés, cryo-coupées en sections vitreuse et observées dans une cryo-microscope électronique. Cette technique, appelée la cryo- microscopie électronique des sections vitrifiées (CEMOVIS), est maintenant considérée comme étant la meilleure façon de conserver l'ultrastructure de tissus et cellules biologiques dans un état très proche de l'état natif. Récemment, cette technique est devenue une méthode pratique fournissant des résultats excellents. Elle a cependant, des limitations importantes, la plus importante d'entre elles est certainement dû aux artefacts de la coupe. Ces artefacts sont la conséquence de la nature du matériel vitreux et le fait que les sections vitreuses ne peuvent pas flotter sur un liquide comme c'est le cas pour les sections en plastique coupées à température ambiante. Le but de ce travail a été d'améliorer notre compréhension du processus de la coupe et des artefacts de la coupe. Nous avons ainsi trouvé des conditions optimales pour minimiser ou empêcher ces artefacts. Un modèle amélioré du processus de coupe et une redéfinitions des artefacts de coupe sont proposés. Les résultats obtenus sous ces conditions sont présentés et comparés aux résultats obtenus avec les méthodes conventionnelles. Abstract Water is often considered to be an ordinary substance since it is transparent, odourless, tasteless and it is very common in nature. As a matter of fact it can be argued that it is the most remarkable of all substances. Without water life on Earth would not exist. Water is the major component of cells, typically forming 70 to 95% of cellular mass and it provides an environment for innumerable organisms to live in, since it covers 75% of Earth surface. Water is a simple molecule made of two hydrogen atoms and one oxygen atom, H2O. The small size of the molecule stands in contrast with its unique physical and chemical properties. Among those the fact that, at the triple point, liquid water is denser than ice is especially remarkable. Despite its special importance in life science, water is systematically removed from biological specimens investigated by electron microscopy. This is because the high vacuum of the electron microscope requires that the biological specimen is observed in dry conditions. For 50 years the science of electron microscopy has addressed this problem resulting in numerous preparation techniques, presently in routine use. Typically these techniques consist in fixing the sample (chemically or by freezing), replacing its water by plastic which is transformed into rigid block by polymerisation. The block is then cut into thin sections (c. 50 nm) with an ultra-microtome at room temperature. Usually, these techniques introduce several artefacts, most of them due to water removal. In order to avoid these artefacts, the specimen can be frozen, cut and observed at low temperature. However, liquid water crystallizes into ice upon freezing, thus causing severe damage. Ideally, liquid water is solidified into a vitreous state. Vitrification consists in solidifying water so rapidly that ice crystals have no time to form. A breakthrough took place when vitrification of pure water was discovered. Since this discovery, the thin film vitrification method is used with success for the observation of biological suspensions of. small particles. Our work was to extend the method to bulk biological samples that have to be vitrified, cryosectioned into vitreous sections and observed in cryo-electron microscope. This technique is called cryo-electron microscopy of vitreous sections (CEMOVIS). It is now believed to be the best way to preserve the ultrastructure of biological tissues and cells very close to the native state for electron microscopic observation. Since recently, CEMOVIS has become a practical method achieving excellent results. It has, however, some sever limitations, the most important of them certainly being due to cutting artefacts. They are the consequence of the nature of vitreous material and the fact that vitreous sections cannot be floated on a liquid as is the case for plastic sections cut at room temperature. The aim of the present work has been to improve our understanding of the cutting process and of cutting artefacts, thus finding optimal conditions to minimise or prevent these artefacts. An improved model of the cutting process and redefinitions of cutting artefacts are proposed. Results obtained with CEMOVIS under these conditions are presented and compared with results obtained with conventional methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L?objectif de ce travail de thèse est l?étude des changements conformationels des biomacromolecules à l?échelle d?une molécule unique. Pour cela on a utilisé la Microscopie à Force Atomique (AFM) appliqué à l?étude des protéines et des acides nucléiques déposés sur une surface. Dans ce type de microscopie, une pointe très fine attachée à l?extrémité d?un levier est balayée au dessus d?une surface. L?interaction de la pointe avec la surface de l?échantillon induit la déflection du levier et ce phénomène permet de reconstruire la topographie de l?échantillon. Très importante dans cette technique est la possibilité de travailler en liquide. Cela permet de étudier les biomolécules en conditions quasi-physiologiques sans qu?elles perdent leur activité. On a étudié GroEL, la chaperonin de E.coli, qui est un homo oligomère avec une structure à double anneau qui joue un rôle très important dans le repliement des protéines dénaturées et celles qui viennent d?être synthétisées. En particulier on a focalisé notre attention sur la stabilité mécanique et sur les changements conformationels qui ont lieu pendant l?activité de GroEL. Une analyse détaillée des changements dans la stabilité mécanique et des effets produits par la liaison et l?hydrolyse de l?ATP est présentée dans ce travail. On a montré que le point le plus faible dans la structure de GroEL est l?interface entre les deux anneaux et que l?étape critique dans l?affaiblissement de la structure est l?hydrolyse de l?ATP. En ce qui concerne le changement conformationel, le passage d?une surface hydrophobe à hydrophile, induit par l?hydrolyse de l?ATP, a été montré. Ensuite on a étudié le changement dans la conformation et dans la topologie de l?ADN résultant de l?interaction avec des molécules spécifiques et en réponse à l?exposition des cellules de E.coli à des conditions de stress. Le niveau de surenroulement est un paramètre très sensible, de façon variée, à tous ces facteurs. Les cellules qui ont crus à de températures plus élevées que leur température optimale ont la tendance à diminuer le nombre de surenroulements négatif pour augmenter la stabilité thermique de leur plasmides. L?interaction avec des agents intercalant induit une transition d?un surenroulement négatif à un surenroulement positif d?une façon dépendante de la température. Finalement, l?effet de l?interaction de l?ADN avec des surfaces différentes a été étudié et une application pratique sur les noeuds d?ADN est présentée.<br/><br/>The aim of the present thesis work is to study the conformational changes of biomacromolecules at the single molecule level. To that end, Atomic Force Microcopy (AFM) imaging was performed on proteins and nucleic acids adsorbed onto a surface. In this microcopy technique a very sharp tip attached at the end of a soft cantilever is scanned over a surface, the interaction of the tip with the sample?s surface will induce the deflection of the cantilever and thus it will make possible to reconstruct the topography. A very important feature of AFM is the possibility to operate in liquid, it means with the sample immersed in a buffer solution. This allows one to study biomolecules in quasi-physiological conditions without loosing their activity. We have studied GroEL, the chaperonin of E.coli, which is a double-ring homooligomer which pays a very important role in the refolding of unfolded and newly synthetized polypeptides. In particular we focus our attention on its mechanical stability and on the conformational change that it undergoes during its activity cycle. A detailed analysis of the change in mechanical stability and how it is affected by the binding and hydrolysis of nucleotides is presented. It has been shown that the weak point of the chaperonin complex is the interface between the two rings and that the critical step to weaken the structure is the hydrolysis of ATP. Concerning the conformational change we have directly measured, with a nanometer scale resolution, the switching from a hydrophobic surface to a hydrophilic one taking place inside its cavity induced by the ATP hydrolysis. We have further studied the change in the DNA conformation and topology as a consequence of the interaction with specific DNA-binding molecules and the exposition of the E.coli cells to stress conditions. The level of supercoiling has been shown to be a very sensitive parameter, even if at different extents, to all these factors. Cells grown at temperatures higher than their optimum one tend to decrease the number of the negative superhelical turns in their plasmids in order to increase their thermal stability. The interaction with intercalating molecules induced a transition from positive to negative supercoiling in a temperature dependent way. The effect of the interaction of the DNA with different surfaces has been investigated and a practical application to DNA complex knots is reported.<br/><br/>Observer les objets biologiques en le touchant Schématiquement le Microscope a Force Atomique (AFM) consiste en une pointe très fine fixée a l?extrémité d?un levier Lors de l?imagerie, la pointe de l?AFM gratte la surface de l?échantillon, la topographie de celui-ci induit des déflections du levier qui sont enregistrées au moyen d?un rayon laser réfléchi par le levier. Ces donnés sont ensuit utilisés par un ordinateur pour reconstituer en 3D la surface de l?échantillon. La résolution de l?instrument est fonction entre autre de la dureté, de la rugosité de l?échantillon et de la forme de la pointe. Selon l?échantillon et la pointe utilisée la résolution de l?AFM peut aller de 0.1 A (sur des cristaux) a quelque dizaine de nanomètres (sur des cellules). Cet instrument est particulierment intéressant en biologie en raison de sa capacité à imager des échantillons immergés dans un liquide, c?est à dire dans des conditions quasiphysiologiques. Dans le cadre de ce travail nous avons étudié les changements conformationels de molécules biologiques soumises à des stimulations externes. Nous avons essentielment concentré notre attention sur des complexes protéiques nommé Chaperons Moléculaires et sur des molécules d?ADN circulaire (plasmides). Les Chaperons sont impliqués entre autre dans la résistance des organismes vivants aux stress thermiques et osmotiques. Leur activité consiste essentielment à aider les autres protéines à être bien pliés dans leur conformation finale et, en conséquence, à eviter que ils soient dénaturées et que ils puissent s?agréger. L?ADN, quant à lui est la molécule qui conserve, dans sa séquence, l?information génétique de tous les organismes vivants. Ce travail a spécifiquement concerné l?étude des changements conformationels des chaperonins suit a leur activation par l?ATP. Ces travaux ont montrés a l?échelle de molécule unique la capacité de ces protéines de changer leur surface de hydrophobique a hydrophilique. Nous avons également utilisé l?AFM pour étudier le changement du nombre des surenroulements des molécules d?ADN circulaire lors d?une exposition à un changement de température et de force ionique. Ces travaux ont permis de montrer comment la cellule regle le nombre de surenroulements dans ces molécules pour répondre et contrôler l?expression génétique même dans de conditions extrêmes. Pour les deux molécules en général, c?était très important d?avoir la possibilité de observer leur transitions d?une conformation a l?autre directement a l?échelle d?une seul molécule et, surtout, avec une résolution largement au dessous des la longueur d?onde de la lumière visible que représente le limite pour l?imagerie optique.