952 resultados para M2-m3 Loop


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Airway smooth muscle constriction induced by cholinergic agonists such as methacholine (MCh), which is typically increased in asthmatic patients, is regulated mainly by muscle muscarinic M3 receptors and negatively by vagal muscarinic M2 receptors. Here we evaluated basal (intrinsic) and allergen-induced (extrinsic) airway responses to MCh. We used two mouse lines selected to respond maximally (AIRmax) or minimally (AIRmin) to innate inflammatory stimuli. We found that in basal condition AIRmin mice responded more vigorously to MCh than AIRmax. Treatment with a specific M2 antagonist increased airway response of AIRmax but not of AIRmin mice. The expression of M2 receptors in the lung was significantly lower in AIRmin compared to AIRmax animals. AIRmax mice developed a more intense allergic inflammation than AIRmin, and both allergic mouse lines increased airway responses to MCh. However, gallamine treatment of allergic groups did not affect the responses to MCh. Our results confirm that low or dysfunctional M2 receptor activity is associated with increased airway responsiveness to MCh and that this trait was inherited during the selective breeding of AIRmin mice and was acquired by AIRmax mice during allergic lung inflammation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

γ-Aminobutyric acid type A receptors (GABAA receptors) are chloride ion channels composed of five subunits, mediating fast synaptic and tonic inhibition in the mammalian brain. These receptors show near five-fold symmetry that is most pronounced in the second trans-membrane domain M2 lining the Cl- ion channel. To take advantage of this inherent symmetry, we screened a variety of aromatic anions with matched symmetry and found an inhibitor, pentacyanocyclopentdienyl anion (PCCP-) that exhibited all characteristics of an open channel blocker. Inhibition was strongly dependent on the membrane potential. Through mutagenesis and covalent modification, we identified the region α1V256-α1T261 in the rat recombinant GABAA receptor to be important for PCCP- action. Introduction of positive charges into M2 increased the affinity for PCCP- while PCCP- prevented the access of a positively charged molecule into M2. Interestingly, other anion selective cys-loop receptors were also inhibited by PCCP-, among them the Drosophila RDL GABAA receptor carrying an insecticide resistance mutation, suggesting that PCCP- could serve as an insecticide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polyethylene chains in the amorphous region between two crystalline lamellae M unit apart are modeled as random walks with one-step memory on a cubic lattice between two absorbing boundaries. These walks avoid the two preceding steps, though they are not true self-avoiding walks. Systems of difference equations are introduced to calculate the statistics of the restricted random walks. They yield that the fraction of loops is (2M - 2)/(2M + 1), the fraction of ties 3/(2M + 1), the average length of loops 2M - 0.5, the average length of ties 2/3M2 + 2/3M - 4/3, the average length of walks equals 3M - 3, the variance of the loop length 16/15M3 + O(M2), the variance of the tie length 28/45M4 + O(M3), and the variance of the walk length 2M3 + O(M2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O uso de medicamentos antimamíticos específicos para vacas no período seco é indicado para prevenção de infecções na lactação seguinte. Não obstante, a ação das células envolvidas no período de secagem tem fundamental importância para a involução da glândula mamária e seu restabelecimento para a lactação subseqüente. A indisponibilidade de tais medicamentos para uso em cabras tem resultado na extrapolação do uso de produtos recomendados para vacas sem que se considerem as particularidades e diferenças anátomo-fisiológicas entre as espécies bovina e caprina. O presente estudo teve por objetivo avaliar a influência de cinco antimamíticos específicos para vacas secas sobre a função dos fagócitos provenientes de leite caprino. Para tal, fez-se o isolamento de células somáticas de 20 amostras de leite provenientes de 10 cabras lactantes, sem antecedentes de tratamento de mamite nos últimos 30 dias, sob condições higiênico-sanitárias de colheita e com resultados negativos ao cultivo microbiológico do leite. As células aderidas a lamínulas de vidro foram confrontadas com formulações contendo princípios ativos disponíveis no mercado como Gentamicina (M1), Cefalônio Anidro (M2), Ampicilina (M3), Cloxacilina Benzatínica (M4) e Cefapirina Benzatínica (M5). Avaliou-se, por microscopia, a fagocitose de partículas de Zymosan. As médias dos índices de fagocitose das células submetidas ao tratamento com M2 (15,12% ± 16,22), M3 (6,02% ± 7,96), M4 (4,54% ± 5,45) e M5 (2,47% ± 4,64) foram menores (p<0,001) que a média dos índices de fagocitose do grupo controle (40,67% ± 19,68). A média dos índices de fagocitose das células submetidas ao tratamento com M2 foi maior (p<0,05) que as médias dos tratamentos com M3, M4 e M5 enquanto estas foram estatisticamente iguais entre si. As amostras celulares submetidas ao medicamento M1 exibiram adesão insuficiente ou ausente às lamínulas, inviabilizando a avaliação da fagocitose por meio da técnica utilizada. Os resultados obtidos permitem concluir que os medicamentos estudados exerceram influência negativa sobre os fagócitos do leite, porém, esta interferência sobre as funções das células somáticas não pode por si só determinar o insucesso da terapia proposta para o período seco, pois deve ser considerada, outrossim, a eficácia do princípio ativo sobre o patógeno causador do processo infeccioso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Com objetivo de estimar parâmetros genéticos e estudar a utilização de diferentes efeitos em avaliações genéticas para idade ao primeiro parto (IPP) por diferentes modelos, foram utilizados registros de IPP de animais da raça Nelore, nascidos entre os anos de 1990 e 2005. Foram considerados os seguintes modelos (M): M1, incluindo o efeito fixo de GC1 (constituído pelos animais nascidos na mesma fazenda e ano), além da covariável, peso aos 365 dias de idade (efeito linear e quadrático), totalizando 24.263 registros de IPP; M2, considerando os efeitos fixos de GC1, ano e estação de parição, totalizando 59.792 registros de IPP e M3, incluindo os efeitos fixos de GC2 (agrupando os animais nascidos na mesma fazenda, ano e que conceberam no mesmo manejo reprodutivo), ano e estação de parição, totalizando 59.792 registros de IPP. As estimativas dos componentes de variância e herdabilidade e os valores genéticos (VG) foram obtidos pelo método da máxima verossimilhança restrita, com a inclusão da matriz de parentesco disponível. As diferenças esperadas na progênie (DEPs) foram obtidas dividindo os VG por dois. Após a obtenção desses resultados, foram realizadas correlações entre os VG e o ranqueamento das DEPs dos reprodutores para IPP, utilizando-se o procedimento PROC CORR (SAS, 2003). Ao se considerar o ano e a estação de parto nos modelos de análise (M2 e M3), esses produziram um maior R², indicando que tais modelos conseguiram explicar, em maior grau, as diferenças existentes entre os animais para IPP. As herdabilidades estimadas foram de baixa magnitude (0,14 e 0,15). As correlações entre os VG obtidas por diferentes modelos foram 0,73 (M1 x M2); 0,91 (M2 x M3) e 0,66 (M1 x M3).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper revisits the design of L and S band bridged loop-gap resonators (BLGRs) for electron paramagnetic resonance applications. A novel configuration is described and extensively characterized for resonance frequency and quality factor as a function of the geometrical parameters of the device. The obtained experimental results indicate higher values of the quality factor (Q) than previously reported in the literature, and the experimental analysis data should provide useful guidelines for BLGR design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have obtained nonperturbative one-loop expressions for the mean-energy-momentum tensor and current density of Dirac's field on a constant electriclike back-round. One of the goals of this calculation is to give a consistent description of backreaction in such a theory. Two cases of initial states are considered: the vacuum state and the thermal equilibrium state. First, we perform calculations for the vacuum initial state. In the obtained expressions, we separate the contributions due to particle creation and vacuum polarization. The latter contribution,, are related to the Heisenberg-Euler Lagrangian. Then, we Study the case of the thermal initial state. Here, we separate the contributions due to particle creation, vacuum polarization, and the contributions due to the work of the external field on the particles at the initial state. All these contributions are studied in detail, in different regimes of weak and strong fields and low and high temperatures. The obtained results allow us to establish restrictions on the electric field and its duration under which QED with a strong constant electric field is consistent. Under such restrictions, one can neglect the backreaction of particles created by the electric field. Some of the obtained results generalize the calculations of Heisenberg-Euler for energy density to the case of arbitrary strong electric fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental study of the Polarization Dependent Loss (PDL) is performed in an Optical Recirculating Loop (RCL). The RCL enables to simulate the transmission through various optical links using just one optical fiber spool, one in line amplifier, some optical filters and devices in a low cost manner. The total amount of PDL in a Recirculating loop, due to its statistical nature, is different of the simple sum of each element of the recirculating loop because of the alignment variation of the PDL elements with time, depending on the environmental conditions such as fiber stress and temperature. In this paper theoretical studies are also performed using formalism of Jones and Mueller matrices in order to represent the different optical elements in the recirculating loop. The PDL must be correctly characterized in order to evaluate properly the impact on the performance of next generation DWDM systems. Theoretical and experimental results comparison shows that a depolarization of 7% occurs in the experimental setup, probably by the optical amplifier due to the depolarized nature of the amplified spontaneous emission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes an approach of optimal sensitivity applied in the tertiary loop of the automatic generation control. The approach is based on the theorem of non-linear perturbation. From an optimal operation point obtained by an optimal power flow a new optimal operation point is directly determined after a perturbation, i.e., without the necessity of an iterative process. This new optimal operation point satisfies the constraints of the problem for small perturbation in the loads. The participation factors and the voltage set point of the automatic voltage regulators (AVR) of the generators are determined by the technique of optimal sensitivity, considering the effects of the active power losses minimization and the network constraints. The participation factors and voltage set point of the generators are supplied directly to a computational program of dynamic simulation of the automatic generation control, named by power sensitivity mode. Test results are presented to show the good performance of this approach. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering the increasing popularity of network-based control systems and the huge adoption of IP networks (such as the Internet), this paper studies the influence of network quality of service (QoS) parameters over quality of control parameters. An example of a control loop is implemented using two LonWorks networks (CEA-709.1) interconnected by an emulated IP network, in which important QoS parameters such as delay and delay jitter can be completely controlled. Mathematical definitions are provided according to the literature, and the results of the network-based control loop experiment are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents results of laboratory testing of unrestrained drying shrinkage during a period of 154 days of different concrete mixtures from the Brazilian production line that utilize ground granulated blast-furnace slag in their compositions. Three concrete mixtures with water/cement ratio of 0.78(M1), 0.41(M2), and 0.37(M3) were studied. The obtained experimental data were compared with the analytical results from prediction models available in the literature: the ACI 209 model (ACI), the B3 model (B3), the Eurocode 2 model (EC2), the GL 2000 model (GL), and the Brazilian NBR 6118 model (NBR), and an analysis of the efficacy of these models was conducted utilizing these experimental data. In addition, the development of the mechanical properties (compressive strength and modulus of elasticity) of the studied concrete mixtures was also measured in the laboratory until 126 days. From this study, it could be concluded that the ACI and the GL were the models that most approximated the experimental drying shrinkage data measured during the analyzed period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinetics of the ethoxylation of fatty alcohols catalyzed by potassium hydroxide was studied to obtain the rate constants for modeling of the industrial process. Experimental data obtained in a lab-scale semibatch autoclave reactor were used to evaluate kinetic and equilibrium parameters. The kinetic model was employed to model the performance of an industrial-scale spray tower reactor for fatty alcohol ethoxylation. The reactor model considers that mass transfer and reaction occur independently in two distinct zones of the reactor. Good agreement between the model predictions and real data was found. These findings confirm the reliability of the kinetic and reactor model for simulating fatty alcohol ethoxylation processes under industrial conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among several process variability sources, valve friction and inadequate controller tuning are supposed to be two of the most prevalent. Friction quantification methods can be applied to the development of model-based compensators or to diagnose valves that need repair, whereas accurate process models can be used in controller retuning. This paper extends existing methods that jointly estimate the friction and process parameters, so that a nonlinear structure is adopted to represent the process model. The developed estimation algorithm is tested with three different data sources: a simulated first order plus dead time process, a hybrid setup (composed of a real valve and a simulated pH neutralization process) and from three industrial datasets corresponding to real control loops. The results demonstrate that the friction is accurately quantified, as well as ""good"" process models are estimated in several situations. Furthermore, when a nonlinear process model is considered, the proposed extension presents significant advantages: (i) greater accuracy for friction quantification and (ii) reasonable estimates of the nonlinear steady-state characteristics of the process. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The atomic force microscope (AFM) introduced the surface investigation with true atomic resolution. In the frequency modulation technique (FM-AFM) both the amplitude and the frequency of oscillation of the micro-cantilever must be kept constant even in the presence of tip-surface interaction forces. For that reason, the proper design of the Phase-Locked Loop (PLL) used in FM-AFM is vital to system performance. Here, the mathematical model of the FM-AFM control system is derived considering high order PLL In addition a method to design stable third-order Phase-Locked Loops is presented. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phase-locked loops (PLLs) are widely used in applications related to control systems and telecommunication networks. Here we show that a single-chain master-slave network of third-order PLLs can exhibit stationary, periodic and chaotic behaviors, when the value of a single parameter is varied. Hopf, period-doubling and saddle-saddle bifurcations are found. Chaos appears in dissipative and non-dissipative conditions. Thus, chaotic behaviors with distinct dynamical features can be generated. A way of encoding binary messages using such a chaos-based communication system is suggested. (C) 2009 Elsevier B.V. All rights reserved.