1000 resultados para Geometria sólida
Resumo:
A phenolic fraction was obtained from of the acetone-water-acetic acid extract of Inga edulis leaves, by liquid-liquid partition and SPE-C18 cartridges. This method provided an increase of 108, 66, 51, 50 and 36% of flavonols, proanthocyanidins, total polyphenols, gallotannins and flavanols, respectively. The major phenolics in purified fraction were procyanidin B2, catechin and myricetin-3-O-α-L-rhamnopyranoside, which achieved increases of 111, 47 and 45%, respectively, after SPE. Acid hydrolysis confirmed the presence of procyanidins, prodelphinidins and glycosylated flavonoids.
Resumo:
A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.
Resumo:
Three analytical methods for the determination of BTEX in water were optimized and validated. With the best method the analytes were extracted of 10 mL of sample with 2.50 g of NaCl in headspace vial of 20 mL by HS and SPME to 40 ºC for 30 min for adsorption and to 250 ºC for 4 min for desorption and were analyzed by GC-MS. The recovery was between 97.9% and 104.3%, and the limit of detection was 2.4 ng L-1 for o-xylene. This method was using to analyze BTEX in water supply and surface water in Ouro Preto city. No sample had concentrations of BTEX above the legislation.
Resumo:
Solid solution of iron doped potassium strontium niobate with KSr2(FeNb4)O15-Δ stoichiometry was prepared by high efficiency ball milling method. Structural characterization was carried out by X-ray diffraction. Crystalline structure was analyzed by the Rietveld refinements using the FullProf software. The results showed a tetragonal system with the tetragonal tungsten bronze structure - TTB (a = 12.4631 (2) Å and c = 3.9322 (6) Å, V = 610.78 (2) ų). In this work, the sites occupancy by the K+, Sr2+ and Fe3+ cations on the TTB structure were determined. NbO6 polihedra distortion and its correlation with the theoretical polarization are discussed.
Resumo:
In this work, the organic compounds of cigar samples from different brands were analyzed. The compound extraction was made using the matrix solid-phase dispersion (MSPD) technique, followed by gas chromatography and identification by mass spectrometry (GC-MS) and standards, when available. Thirty eight organic compounds were found in seven different brands. Finally, with the objective of characterizing and discriminating the cigar samples, multivariate statistical analyses were applied to data, e.g.; principal component analysis (PCA) and hierarchical cluster analysis (HCA). With such analyses, it was possible to discriminate three main groups of three quality levels.
Resumo:
Despite the increase in peptide chain aggregation, which decreases the rate of coupling reactions, the synthesis and use of very highly substituted resins still remains as a controversial point in the SPPS, due to its clear economical advantages (lesser solvent consumption and higher amount of peptide per synthesis). In order to better investigate the synthesis and the use of very highly substituted resins, the FTIR, NMR and EPR were compared. By FTIR techniques it was possible to follow all the steps of resin synthesis and the factors affecting the aggregation of the chains inside the peptidil-BHAR and MBHAR.
Resumo:
A fruit chemical composition reflects its maturation stage. For coffee, it is also the reflex of the post-harvesting processing type, dry, semi-wet and wet. The object of this work was to verify if headspace solid phase microextraction coupled to gas chromatography (HS-SPME-GC) could be used to discriminate between samples harvested in different maturation stages and treated by different processes. With application of principal component analysis to the area of 117 compounds extracted by SPME, using divinylbenzene/Carboxen/polydimethylsiloxane fiber, it was possible to discriminate, in the roasted and ground coffee, the maturity stage and processing type used .
Resumo:
A method based on headspace - solid phase microextraction coupled with gas chromatography - mass spectrometry was validated for the quantitative determination of 18 organochlorine pesticides in water. For the extraction conditioning some parameters as the best type of coating fiber, time and temperature of extraction, pH and ionic strength were evaluated. The method HS-SPME/GC-MS/MS showed linear coefficient above 0.9948. The repeatability of the measurements were lower than 7.6%. Relative recoveries were between 88 and 110%. Limits of detection from 0.5 x 10-3 to 1.0 mg L-1 were obtained. A total of 31 samples were analyzed and 16 presented from 1 to 5 pesticides.
Resumo:
SPME-GC-MS, PCA and HCA multivariate techniques were used in order to evaluate their applicability to discriminate the three chemotypes (thymol, carvacrol and mixed) described for L. graveolens of Guatemala. The leaves of L. graveolens are used for treatment of colds, bronchitis, and as seasoning for food preparations, yielding essential oil up to 4.34 %. Leaves of 35 individuals from eight populations, and eight composite samples were analyzed using a DVB/Carboxen/PDMS fiber and GC-MS. PCA and HCA were carried out using eight markers (p-cymene, cis-sabinene hydrate, linalool, terpinen-4-ol, thymol, carvacrol, (E)-caryophyllene and caryophyllene oxide). The three chemotypes of L. graveolens were satisfactorily discriminated.
Resumo:
This paper describes an analytical method for analyzing polychlorinated biphenyls in corn samples using solid phase extraction (SPE) followed by determination by GC-MS. All calibration curves proved linear (r> 0.99). Recoveries ranged between 74.1 and 110.6% with relative standard deviation lower than 20% for all compounds. The limits of quantitation for the method were between 0.025 and 0.1 ng g-1. Of the 51 samples analyzed, PCB 180 showed the highest frequency, being detected in more than 39%, followed by PCB 138, detected in more than 33% of samples.
Resumo:
Considering all the aspects of the principles of green chemistry, we present herein the addition reactions of amines to 1,4-naphthoquinone in water as solvent and also in solid phase. These reactions resulted in very colorful products that were easily monitored by thin layer chromatography and consequently easy to separate. Therefore, they are interesting experiments for experimental organic chemistry in the classrooms or in the laboratories.
Resumo:
A multiresidue method using HPLC/DAD for the determination of fourteen pesticides in water based on SPE, using SDVB (styrene divynilbenzene copolymer) as adsorbent was validated. Recoveries from 61 to 120%, relative standard deviation between 2 and 15% and detection limits from 0.07 to 0.75 µg L-1 were obtained. It was applied to 66 surface water samples collected in a degraded area at the headwaters of São Lourenço river, Mato Grosso, Brazil. Eight pesticides were detected in concentrations ranging from 0.15 to 35.25 µg L-1. Considering ecotoxicological data, carbendazim and carbofuran may represent a risk to aquatic organisms. These results draw attention to the contamination of this vulnerable degraded area.
Resumo:
Extraction/concentration is a crucial step for the analysis of organic compounds at trace level concentrations and dispersed in complex matrices. Solid-phase extraction (SPE) is one of the techniques used for this purpose. In this work, a low cost apparatus for SPE was developed that uses nitrogen under positive pressure and ensures the maintenance of the sample flow, while also allows the simultaneous extraction of different samples without cross-contamination and sample contact with plastic materials. For the system set up, easily accessible materials were used such as hypodermic needles, stainless steel tubes, rubber stoppers, and 3-way valves from serum delivery apparatus.
Resumo:
A new method using the headspace solid phase microextraction (HS-SPME) technique was used to evaluate the infinite dilute activity coefficient (γ1∞) in an alcohol/water/salt system. The studied systems were ethanol and water with NaCl and NH4Cl at salt concentrations of 5, 10, 15, and 30% m/v and temperatures of 303.15 and 313.15 K. The method was used to investigate the salt effect on vapor/liquid equilibrium in an ethanol/water system, yielding satisfactory results. The study focused on the rich side in ethanol. The data were compared with the literature infinite dilution data determined by other methods such as differential ebulliometry (EBUL), differential static cell equilibrium (STAT), and gas-liquid chromatography with no gas phase correction (GC). In this study, NaCl showed better separation rates than NH4Cl.
Resumo:
C18 chemically bonded sorbents have been the main materials used in solid phase extraction (SPE). However, due their high hydrophobicity some hydrophobic solutes are strongly retained leading to the consumption of larger quantities of organic solvent for efficient recoveries. This work presents a sorbent with lower hydrophobicity but similar selectivity to the C18 sorbent, prepared by thermal immobilization of poly(dimethylsiloxane-co-alkylmethylsiloxane) (PDAS) on silica. PDAS has organic chains with methyl groups alternating with octadecyl or hexadecyl groups in its monomeric unities. For the Si(PDAS) sorbent presented, the polymeric layer was physically adsorbed on the silica surface with 12% carbon load. Although the coating of silica with the polymeric layer was incomplete, the PDAS provided better protection for the silica surface groups, promoting mostly hydrophobic interactions between analytes and the sorbent. Sorption isotherm studies revealed that the retention of hydrophobic solutes on Si(PDAS) was less intense than on conventional sorbents, confirming the lower hydrophobicity of the lab-made sorbent. Additional advantages of Si(PDAS) include simplicity and low cost of preparation, making this material a potential sorbent for the analysis of highly hydrophobic solutes.