Three analytical methods for the determination of BTEX in water were optimized and validated. With the best method the analytes were extracted of 10 mL of sample with 2.50 g of NaCl in headspace vial of 20 mL by HS and SPME to 40 ºC for 30 min for adsorption and to 250 ºC for 4 min for desorption and were analyzed by GC-MS. The recovery was between 97.9% and 104.3%, and the limit of detection was 2.4 ng L-1 for o-xylene. This method was using to analyze BTEX in water supply and surface water in Ouro Preto city. No sample had concentrations of BTEX above the legislation. |