942 resultados para Difference Between Generation X and Y Employees
Resumo:
Our review looks at pollinator conservation and highlights the differences in approach between managing for pollination services and preserving pollinator diversity. We argue that ecosystem service management does not equal biodiversity conservation, and that maintaining species diversity is crucial in providing ecosystem resilience in the face of future environmental change. Management and policy measures therefore need to focus on species not just in human dominated landscapes but need to benefit wider diversity of species including those in specialised habitats. We argue that only by adopting a holistic ecosystem approach we can ensure the conservation and sustainable use of biodiversity and ecosystem services in the long-term.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
We combine the D0 measurement of the width difference between the light and heavy B-s(0) mass eigenstates and of the CP-violating mixing phase determined from the time-dependent angular distributions in the B-s(0)-> J/psi phi decays along with the charge asymmetry in semileptonic decays also measured with the D0 detector. With the additional constraint from the world average of the flavor-specific B-s(0) lifetime, we obtain Delta Gamma(s)equivalent to(Gamma(L)-Gamma(H))=0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=0.70(-0.47)(+0.39) or Delta Gamma(s)=-0.13 +/- 0.09 ps(-1) and vertical bar phi(s)vertical bar=2.44(-0.39)(+0.47). The data sample corresponds to an integrated luminosity of 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron Collider.
Resumo:
We present a study of the decay B-s(0)-> J/psi phi. We obtain the CP-odd fraction in the final state at time zero R-perpendicular to = 0.16 +/- 0.10 (stat) +/- 0.02(syst), the average lifetime of the (B-s(0), (B) over bar (0)(s)) system, (tau) over bar (B-s(0)) = 1.39(-0.16)(+0.13)(stat)(-0.02)(+0.01)(syst) ps, and the relative width difference between the heavy and light mass eigen-states, Delta Gamma/(Gamma) over bar = (Gamma(L) - Gamma(H))/(Gamma) over bar = 0.24(-0.38)(+0.28)(stat)(-0.04)(+0.03)(syst). With the additional constraint from the world average of the B-s(0) lifetime measurements using semileptonic decays, we find (tau) over bar (B-s(0)) = 1.39 +/- 0.06 ps and Delta Gamma/(Gamma) over bar = 0.25(-0.15)(+0.14). For the ratio of the B-s(0) and B-0 lifetimes we obtain (tau) over bar (B-s(0))/tau(B-s(0)) = 0.91 +/- 0.09(stat) +/- 0.003(syst).
Resumo:
From an analysis of the decay B-s(0)-> J/psi phi, we obtain the width difference between the light and heavy mass eigenstates Delta Gamma equivalent to(Gamma(L)-Gamma(H))=0.17 +/- 0.09(stat)+/- 0.02(syst) ps(-1) and the CP-violating phase phi(s)=-0.79 +/- 0.56(stat)(-0.01)(+0.14)(syst). Under the hypothesis of no CP violation (phi(s)equivalent to 0), we obtain 1/Gamma=tau/(B-s(0))=1.52 +/- 0.08(stat)(-0.03)(+0.01)(syst) ps and Delta Gamma=0.12(-0.10)(+0.08)(stat)+/- 0.02(syst) ps(-1). The data sample corresponds to an integrated luminosity of about 1.1 fb(-1) accumulated with the D0 detector at the Fermilab Tevatron collider. This is the first direct measurement of the CP-violating mixing phase in the B-s(0) system.
Resumo:
We present results from a study of p (p) over bar -> W gamma+X events utilizing data corresponding to 0.7 fb(-1) of integrated luminosity at root s = 1.96 TeV collected by the D0 detector at the Fermilab Tevatron Collider. We set limits on anomalous WW gamma couplings at the 95% C.L. The one-dimensional 95% C.L. limits are 0.49
Resumo:
Morphology of three samples of alumina are investigated. Infrared spectra are analysed by use of their morphology through the theory of average dielectric constant. Crystal shape is obtained from X-ray diffraction patterns by reflection intensity ratio. In the case of electron scanning microscopy, shape factor was obtained by an average axial ratio of the particles. Comparison of results show that there is agreement among these techniques and infrared spectra can be used to determine the morphology of alumina particles from 2.7 to 10 mu m, even for heterogeneous samples. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To test the bond strength between a quartz-fiber-reinforced composite post (FRC) and a resin cement. The null hypothesis was that the bond strength can be increased by using a chairside tribochemical silica-coating system. Materials and Methods: Thirty quartz-FRCs (Light-Post) were divided into 3 groups according to the post surface treatment: G1) Conditioning with 32% phosphoric acid (1 min), applying a silane coupling agent; G2) etching with 10% hydrofluoric acid (1 min), silane application; G3) chairside tribochemical silica coating method (CoJet System): air abrasion with 30-μ SiO x-modified Al2O3 particles, silane application. Thereafter, the posts were cemented into a cylinder (5 mm diameter, 15 mm height) with a resin cement (Duo-Link). After cementation, the specimens were stored in distilled water (37°C/24 h) and sectioned along the x and y axes with a diamond wheel under cooling (Lab-cut 1010) to create nontrimmed bar specimens. Each specimen was attached with cyanoacrylate to an apparatus adapted for the microtensile test. Microtensile testing was conducted on a universal testing machine (1 mm/min). The data obtained were submitted to the one-way ANOVA and Tukey test (α = 0.05). Results: A significant influence of the conditioning methods was observed (p < 0.0001). The bond strength of G3 (15.14 ± 3.3) was significantly higher than the bond strengths of G1 (6.9 ± 2.3) and G2 (12.60 ± 2.8) (p = 0.000106 and p = 0.002631, respectively). Notwithstanding the groups, all the tested specimens showed adhesive failure between the resin cement and FRC. Conclusion: The chairside tribochemical system yielded the highest bond strength between resin cement and quartz-fiber post. The null hypothesis was accepted (p < 0.0001).
Resumo:
Purpose: This study evaluated the effect of surface conditioning methods and thermocycling on the bond strength between a resin composite and an indirect composite system in order to test the repair bond strength. Materials and Methods: Eighteen blocks (5 x 5 x 4 mm) of indirect resin composite (Sinfony) were fabricated according to the manufacturer's instructions. The specimens were randomly assigned to one of the following two treatment conditions (9 blocks per treatment): (1) 10% hydrofluoric acid (HF) for 90 s (Dentsply) + silanization, (2) silica coating with 30-Ìm SiOx particles (CoJet) + silanization. After surface conditioning, the bonding agent was applied (Adper Single Bond) and light polymerized. The composite resin (W3D Master) was condensed and polymerized incrementally to form a block. Following storage in distilled water at 37°C for 24 h, the indirect composite/resin blocks were sectioned in two axes (x and y) with a diamond disk under coolant irrigation to obtain nontrimmed specimens (sticks) with approximately 0.6 mm2 of bonding area. Twelve specimens were obtained per block (N = 216, n = 108 sticks). The specimens from each repaired block were again randomly divided into 2 groups and tested either after storage in water for 24 h or thermocycling (6000 cycles, 5°C to 55°C). The microtensile bond strength test was performed in a universal testing machine (crosshead speed: 1 mm/min). The mean bond strengths of the specimens of each block were statistically analyzed using two-way ANOVA (α = 0.05). Results: Both surface conditioning (p = 0.0001) and storage conditions (p = 0.0001) had a significant effect on the results. After 24 h water storage, silica coating and silanization (method 2) showed significantly higher bond strength results (46.4 ± 13.8 MPa) than that of hydrofluoric acid etching and silanization (method 1) (35.8 ± 9.7 MPa) (p < 0.001). After thermocycling, no significant difference was found between the mean bond strengths obtained with method 1 (34.1 ± 8.9 MPa) and method 2 (31.9 ± 7.9 MPa) (p > 0.05). Conclusion: Although after 24 h of testing, silica coating and silanization performed significantly better in resin-resin repair bond strength, both HF acid gel and silica coating followed by silanization revealed comparable bond strength results after thermocycling for 6000 times.
Resumo:
We present results from a study of pp̄→Wγ+X events utilizing data corresponding to 0.7fb-1 of integrated luminosity at s=1.96TeV collected by the D0 detector at the Fermilab Tevatron Collider. We set limits on anomalous WWγ couplings at the 95% C.L. The one-dimensional 95% C.L. limits are 0.49<κγ<1.51 and -0.12<λγ<0.13. We make the first study of the charge-signed rapidity difference between the lepton and the photon and find it to be indicative of the standard model radiation-amplitude zero in the Wγ system. © 2008 The American Physical Society.
Resumo:
Results are presented from a search for third-generation leptoquarks and scalar bottom quarks in a sample of proton-proton collisions at √s=7Tev collected by the CMS experiment at the LHC, corresponding to an integrated luminosity of 4.7 fb-1. A scenario where the new particles are pair produced and each decays to a b quark plus a tau neutrino or neutralino is considered. The number of observed events is found to be in agreement with the standard model prediction. Upper limits are set at 95% confidence level on the production cross sections. Leptoquarks with masses below ~450 GeV are excluded. Upper limits in the mass plane of the scalar quark and neutralino are set such that scalar bottom quark masses up to 410 GeV are excluded for neutralino masses of 50 GeV. © 2012 CERN for the benefit of CMS collaboration.
Resumo:
In trickle irrigation systems, the design is based on the pre-established emission uniformity (EU) which is the combined result of the equipment characteristics and its hydraulic configuration. However, this desired value of the EU may not be confirmed by the final project (in field conditions) and neither by the yield uniformity. The hypotheses of this research were: a) the EU of a trickle irrigation system at field conditions is equal to the emission uniformity pre-established in the its design; b) EU has always the lowest value when compared with other indicators of uniformity; c) the discharge variation coefficient (VC) is not equal to production variation coefficient in the operational unit; d) the difference between the discharge variation coefficient and the productivity variation coefficient depends on the water depth applied. This study aimed to evaluate the relationship between EU used in the irrigation system design and the final yield uniformity. The uniformity indicators evaluated were: EU, distribution uniformity (UD) and the index proposed by Barragan & Wu (2005). They were compared estimating the performance of a trickle irrigation system applied in a citrus orchard with dimensions of 400m x 600m. The design of the irrigation system was optimized by a Linear Programming model. The tree rows were leveled in the larger direction and the spacing adopted in the orchard was 7m x 4m. The manifold line was always operating on a slope condition. The sensitivity analysis involved different slopes, 0, 3, 6, 9 and 12%, and different values of emission uniformity, 60, 70, 75, 80, 85, 90 and 94%. The citrus yield uniformity was evaluated by the variation coefficient. The emission uniformity (EU) after design differed from the EU pre-established, more sharply in the initial values lower than 90%. Comparing the uniformity indexes, the EU always generated lower values when compared with the UD and with the index proposed by Barragan. The emitter variation coefficient was always lower than the productivity variation coefficient. To obtain uniformity of production, it is necessary to consider the irrigation system uniformity and mainly the water depth to be applied.
Resumo:
Incluye Bibliografía
Resumo:
Incluye Bibliografía