970 resultados para Chromatographic columns


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new finite element method is developed to analyse non-conservative structures with more than one parameter behaving in a stochastic manner. As a generalization, this paper treats the subsequent non-self-adjoint random eigenvalue problem that arises when the material property values of the non-conservative structural system have stochastic fluctuations resulting from manufacturing and measurement errors. The free vibration problems of stochastic Beck's column and stochastic Leipholz column whose Young's modulus and mass density are distributed stochastically are considered. The stochastic finite element method that is developed, is implemented to arrive at a random non-self-adjoint algebraic eigenvalue problem. The stochastic characteristics of eigensolutions are derived in terms of the stochastic material property variations. Numerical examples are given. It is demonstrated that, through this formulation, the finite element discretization need not be dependent on the characteristics of stochastic processes of the fluctuations in material property value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Columns which have stochastically distributed Young's modulus and mass density and are subjected to deterministic periodic axial loadings are considered. The general case of a column supported on a Winkler elastic foundation of random stiffness and also on discrete elastic supports which are also random is considered. Material property fluctuations are modeled as independent one-dimensional univariate homogeneous real random fields in space. In addition to autocorrelation functions or their equivalent power spectral density functions, the input random fields are characterized by scale of fluctuations or variance functions for their second order properties. The foundation stiffness coefficient and the stiffnesses of discrete elastic supports are treated to constitute independent random variables. The system equations of boundary frequencies are obtained using Bolotin's method for deterministic systems. Stochastic FEM is used to obtain the discrete system with random as well as periodic coefficients. Statistical properties of boundary frequencies are derived in terms of input parameter statistics. A complete covariance structure is obtained. The equations developed are illustrated using a numerical example employing a practical correlation structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonconservatively loaded columns. which have stochastically distributed material property values and stochastic loadings in space are considered. Young's modulus and mass density are treated to constitute random fields. The support stiffness coefficient and tip follower load are considered to be random variables. The fluctuations of external and distributed loadings are considered to constitute a random field. The variational formulation is adopted to get the differential equation and boundary conditions. The non self-adjoint operators are used at the boundary of the regularity domain. The statistics of vibration frequencies and modes are obtained using the standard perturbation method, by treating the fluctuations to be stochastic perturbations. Linear dependence of vibration and stability parameters over property value fluctuations and loading fluctuations are assumed. Bounds for the statistics of vibration frequencies are obtained. The critical load is first evaluated for the averaged problem and the corresponding eigenvalue statistics are sought. Then, the frequency equation is employed to transform the eigenvalue statistics to critical load statistics. Specialization of the general procedure to Beck, Leipholz and Pfluger columns is carried out. For Pfluger column, nonlinear transformations are avoided by directly expressing the critical load statistics in terms of input variable statistics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Simple and rapid HPLC, GC, and TLC procedures have been developed for detection and determination of nimesulide, a non-pharmacopeial drug, in preformulation and dosage form. Use of these techniques has enabled separation of impurities and the precursor in the bulk material and in formulations. Isocratic reversed-phase HPLC was performed on a C-18 column with methanol-water-acetic acid, 67:32:1 (v/v), as mobile phase and UV detection at 230 nm. Calibration curves were linear over the concentration range 100-1000 mug mL(-1) with a good correlation coefficient (0.9993) and a coefficient of variation of 1.5%. Gas chromatography was performed on an OV-17 packed column with temperature programming and flame-ionization detection. The lower limit of determination by HPLC and GC was 4 ppm. Thin-layer chromatography of nimesulide was performed on silica gel G with toluene-ethyl acetate, 8:2, as mobile phase. Stability testing of the drug was performed under different temperature, humidity, and UV-radiation conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flavokinase was purified, for the first time from a plant source [mung bean (Phaseolus aureus)] by affinity chromatography in the presence of orthophosphate and by using C-8 ATP-agarose (ATP linked through the C-8 position to beaded agarose), Cibacron Blue and riboflavin--Sepharoses. An altered substrates-saturation pattern was observed in the presence of K2HPO4. The conformational changes of the enzyme in the presence of K2HPO4 were monitored by fluorescence spectroscopy. These results highlight the regulatory nature of this enzyme.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic acids are important constituents of fruit juices. They render tartness, flavour and specific taste to fruit juices. Shelf life and stability of fruit juices are important factors, which determine their nutritional quality and freshness. In this view, the effect of storage on the concentration of organic acids in commercially packed fruit juices is studied by reverse phase high performance liquid chromatography (RP-HPLC). Ten packed fruit juices from two different brands are stored at 30 C for 24, 48 and 72 hours. A reverse phase high performance liquid chromatographic method is used to determine the concentration of oxalic, tartaric, malic, ascorbic and citric acid in the fruit juices during storage. The chromatographic analysis of organic acids is carried out using mobile phase 0.5% (w/v) ammonium dihydrogen orthophosphate buffer (pH 2.8) on C18 column with UV-Vis detector. The results show that the concentration of organic acids generally decreases in juices under study with the increase in storage time. All the fruit juices belonging to tropicana brand underwent less organic acid degradation in comparison to juices of real brand. Orange fruit juice is found to be least stable among the juices under study, after the span of 72 hours. Amongst all the organic acids under investigation minimum stability is shown by ascorbic acid followed by malic and citric acid.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O Leito Móvel Simulado (LMS) é um processo de separação de compostos por adsorção muito eficiente, por trabalhar em um regime contínuo e também possuir fluxo contracorrente da fase sólida. Dentre as diversas aplicações, este processo tem se destacado na resolução de petroquímicos e principalmente na atualidade na separação de misturas racêmicas que são separações de um grau elevado de dificuldade. Neste trabalho foram propostas duas novas abordagens na modelagem do LMS, a abordagem Stepwise e a abordagem Front Velocity. Na modelagem Stepwise as colunas cromatográficas do LMS foram modeladas com uma abordagem discreta, onde cada uma delas teve seu domínio dividido em N células de mistura interligadas em série, e as concentrações dos compostos nas fases líquida e sólida foram simuladas usando duas cinéticas de transferência de massa distintas. Essa abordagem pressupõe que as interações decorrentes da transferência de massa entre as moléculas do composto nas suas fases líquida e sólida ocorram somente na superfície, de forma que com essa suposição pode-se admitir que o volume ocupado por cada molécula nas fases sólida e líquida é o mesmo, o que implica que o fator de residência pode ser considerado igual a constante de equilíbrio. Para descrever a transferência de massa que ocorre no processo cromatográfico a abordagem Front Velocity estabelece que a convecção é a fase dominante no transporte de soluto ao longo da coluna cromatográfica. O Front Velocity é um modelo discreto (etapas) em que a vazão determina o avanço da fase líquida ao longo da coluna. As etapas são: avanço da fase líquida e posterior transporte de massa entre as fases líquida e sólida, este último no mesmo intervalo de tempo. Desta forma, o fluxo volumétrico experimental é utilizado para a discretização dos volumes de controle que se deslocam ao longo da coluna porosa com a mesma velocidade da fase líquida. A transferência de massa foi representada por dois mecanismos cinéticos distintos, sem (tipo linear) e com capacidade máxima de adsorção (tipo Langmuir). Ambas as abordagens propostas foram estudadas e avaliadas mediante a comparação com dados experimentais de separação em LMS do anestésico cetamina e, posteriormente, com o fármaco Verapamil. Também foram comparados com as simulações do modelo de equilíbrio dispersivo para o caso da Cetamina, usado por Santos (2004), e para o caso do Verapamil (Perna 2013). Na etapa de caracterização da coluna cromatográfica as novas abordagens foram associadas à ferramenta inversa R2W de forma a determinar os parâmetros globais de transferência de massa apenas usando os tempos experimentais de residência de cada enantiômero na coluna de cromatografia líquida de alta eficiência (CLAE). Na segunda etapa os modelos cinéticos desenvolvidos nas abordagens foram aplicados nas colunas do LMS com os valores determinados na caracterização da coluna cromatográfica, para a simulação do processo de separação contínua. Os resultados das simulações mostram boa concordância entre as duas abordagens propostas e os experimentos de pulso para a caracterização da coluna na separação enantiomérica da cetamina ao longo do tempo. As simulações da separação em LMS, tanto do Verapamil quando da Cetamina apresentam uma discrepância com os dados experimentais nos primeiros ciclos, entretanto após esses ciclos iniciais a correlação entre os dados experimentais e as simulações. Para o caso da separação da cetamina (Santos, 2004), a qual a concentração da alimentação era relativamente baixa, os modelos foram capazes de predizer o processo de separação com as cinéticas Linear e Langmuir. No caso da separação do Verapamil (Perna, 2013), onde a concentração da alimentação é relativamente alta, somente a cinética de Langmuir representou o processo, devido a cinética Linear não representar a saturação das colunas cromatográficas. De acordo como o estudo conduzido ambas as abordagens propostas mostraram-se ferramentas com potencial na predição do comportamento cromatográfico de uma amostra em um experimento de pulso, assim como na simulação da separação de um composto no LMS, apesar das pequenas discrepâncias apresentadas nos primeiros ciclos de trabalho do LMS. Além disso, podem ser facilmente implementadas e aplicadas na análise do processo, pois requer um baixo número de parâmetros e são constituídas de equações diferenciais ordinárias.