High performance thin layer chromatographic determination of nifedipine in human serum after liquid-liquid extraction


Autoria(s): Mennickent,Sigrid; Contreras,Jonathan; Schulz,Berta; Diego,Marta de; Vega,Mario
Data(s)

01/01/2012

Resumo

A method using HPTLC for quantitation of nifedipine in serum was developed and validated. It includes a liquid-liquid extraction, and carbamazepine as internal standard. Chloroform: ethyl acetate: cyclohexane (19:2:2, v/v/v) was the mobile phase. The method showed good relationship (r = 0.996) (2.00 to 25.00 ng/band, corresponding to 0.02 and 0.25 ng/µL in serum). The % RSD of intra-assay and inter-assay, were between 0.57 and 3.56 and 1.16 to 3.60, respectively. LOD and LOQ were 0.72 and 0.86 ng/band, respectively. The recovery values were between 93 and 102%. Rf for nifedipine and carbamazepine were 0.31 and 0.10, respectively.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000200032

Idioma(s)

en

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.35 n.2 2012

Palavras-Chave #nifedipine #high performance thin layer chromatography #quantitative determination