990 resultados para thrombocyte count


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Best long-term practice in primary HIV-1 infection (PHI) remains unknown for the individual. A risk-based scoring system associated with surrogate markers of HIV-1 disease progression could be helpful to stratify patients with PHI at highest risk for HIV-1 disease progression. METHODS: We prospectively enrolled 290 individuals with well-documented PHI in the Zurich Primary HIV-1 Infection Study, an open-label, non-randomized, observational, single-center study. Patients could choose to undergo early antiretroviral treatment (eART) and stop it after one year of undetectable viremia, to go on with treatment indefinitely, or to defer treatment. For each patient we calculated an a priori defined "Acute Retroviral Syndrome Severity Score" (ARSSS), consisting of clinical and basic laboratory variables, ranging from zero to ten points. We used linear regression models to assess the association between ARSSS and log baseline viral load (VL), baseline CD4+ cell count, and log viral setpoint (sVL) (i.e. VL measured ≥90 days after infection or treatment interruption). RESULTS: Mean ARSSS was 2.89. CD4+ cell count at baseline was negatively correlated with ARSSS (p = 0.03, n = 289), whereas HIV-RNA levels at baseline showed a strong positive correlation with ARSSS (p<0.001, n = 290). In the regression models, a 1-point increase in the score corresponded to a 0.10 log increase in baseline VL and a CD4+cell count decline of 12/µl, respectively. In patients with PHI and not undergoing eART, higher ARSSS were significantly associated with higher sVL (p = 0.029, n = 64). In contrast, in patients undergoing eART with subsequent structured treatment interruption, no correlation was found between sVL and ARSSS (p = 0.28, n = 40). CONCLUSION: The ARSSS is a simple clinical score that correlates with the best-validated surrogate markers of HIV-1 disease progression. In regions where ART is not universally available and eART is not standard this score may help identifying patients who will profit the most from early antiretroviral therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Mean platelet volume (MPV) was shown to be significantly increased in patients with acute ischaemic stroke, especially in non-lacunar strokes. Moreover, some studies concluded that increased MPV is related to poor functional outcome after ischaemic stroke, although this association is still controversial. However, the determinants of MPV in patients with acute ischaemic stroke have never been investigated. Subjects and methods: We recorded the main demographic, clinical and laboratory data of consecutive patients with acute (admitted within 24 h after stroke onset) ischaemic stroke admitted in our Neurology Service between January 2003 and December 2008. MPV was generated at admission by the Sysmex XE-2100 automated cell counter (Sysmex Corporation, Kobe, Japan) from ethylenediaminetetraacetic acid blood samples stored at room temperature until measurement. The association of these parameters with MPV was investigated in univariate and multivariate analysis. Results: A total of 636 patients was included in our study. The median MPV was 10.4 ± 0.82 fL. In univariate analysis, glucose (β= 0.03, P= 0.05), serum creatinine (β= 0.002, P= 0.02), haemoglobin (β= 0.009, P < 0.001), platelet count (β=-0.002, P < 0.001) and history of arterial hypertension (β= 0.21, P= 0.005) were found to be significantly associated with MPV. In multivariate robust regression analysis, only hypertension and platelet count remained as independent determinants of MPV. Conclusions: In patients with acute ischaemic stroke, platelet count and history of hypertension are the only determinants of MPV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Performing a complete blood count analysis is a daily routine necessary for a good care of patients. Nowadays, modern blood analyzers provide on top of classical blood values, several additional parameters. In this paper, using short case presentations, we discuss how to interpret these results and integrate them in the clinical context.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Goals: Adjuvant chemotherapy decisions in breast cancer are increasing based on the pathologist's assessment of the proliferation fraction in the tumor. Yet, how good and how reproducible are we pathologists at providing reliable Ki-67 readings on breast carcinomas. Exactly how to count and in which areas to count within a tumor remains inadequately standardized. The Swiss Working Group of Gyneco- and Breast Pathologists has tried to appreciate this dilemma and to propose ways to obtain more reproducible results.Methods: In a first phase, 5 pathologists evaluated Ki67 counts in 10 breast cancers by exact counting (500 cells) and by eyeballing. Pathologists were free to select the region in which Ki67 was evaluated. In a second phase 16 pathologists evaluated Ki-67 counts in 3 breast cancers also by exact counting and eyeballing, but in predefined fields of interest. In both phases, Ki67 was assessed in centrally immunostained slides (ZH) and on slides immunostained in the 11 participating laboratories. In a third phase, these same 16 pathologists were once again asked to read the 3 cases from phase 2, plus three new cases, and this time exact guidelines were provided as to what exactly is considered a Ki-67 positive nucleus.Results: Discordance of Ki67 assessment was due to each of the following 4 factors: (i) pathologists' divergent definitions of what counts as a positive nucleus (ii) the mode of assessment (counting vs. eyeballing), (iii) immunostaining technique/protocol/antibody, and (iv) the selection of the area in which to count.Conclusion: Providing guidelines as to where to count (representative field in the tumor periphery and omitting hot spots) and what nuclei to count (even faintly immunostained nuclei count as positive) reduces the discordance rates of Ki67 readings between pathologists. Laboratory technique is only of minor importance (even over a large antibody dilution range), and counting nuclei does not improve accuracy, but rather aggravates deviations from the group mean values.Disclosure of Interest: None Declared

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CD34/QBEND10 immunostaining has been assessed in 150 bone marrow biopsies (BMB) including 91 myelodysplastic syndromes (MDS), 16 MDS-related AML, 25 reactive BMB, and 18 cases where RA could neither be established nor ruled out. All cases were reviewed and classified according to the clinical and morphological FAB criteria. The percentage of CD34-positive (CD34 +) hematopoietic cells and the number of clusters of CD34+ cells in 10 HPF were determined. In most cases the CD34+ cell count was similar to the blast percentage determined morphologically. In RA, however, not only typical blasts but also less immature hemopoietic cells lying morphologically between blasts and promyelocytes were stained with CD34. The CD34+ cell count and cluster values were significantly higher in RA than in BMB with reactive changes (p&lt;0.0001 for both), in RAEB than in RA (p=0.0006 and p=0.0189, respectively), in RAEBt than in RAEB (p=0.0001 and p=0.0038), and in MDS-AML than in RAEBt (p&lt;0.0001 and p=0.0007). Presence of CD34+ cell clusters in RA correlated with increased risk of progression of the disease. We conclude that CD34 immunostaining in BMB is a useful tool for distinguishing RA from other anemias, assessing blast percentage in MDS cases, classifying them according to FAB, and following their evolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A general MHC-heterozygote advantage in parasite-infected organisms is often assumed, although there is little experimental evidence for this. We tested the response of MHC-congenic mice (F2 segregants) to malaria and found the course of infection to be significantly influenced by MHC haplotype, parasite strain, and host gender. However, the MHC heterozygotes did worse than expected from the average response of the homozygotes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several population pharmacokinetic (PPK) analyses of the anticancer drug imatinib have been performed to investigate different patient populations and covariate effects. The present analysis offers a systematic qualitative and quantitative summary and comparison of those. Its primary objective was to provide useful information for evaluating the expectedness of imatinib plasma concentration measurements in the frame of therapeutic drug monitoring. The secondary objective was to review clinically important concentration-effect relationships to provide help in evaluating the potential suitability of plasma concentration values. Nine PPK models describing total imatinib plasma concentration were identified. Parameter estimates were standardized to common covariate values whenever possible. Predicted median exposure (Cmin) was derived by simulations and ranged between models from 555 to 1388 ng/mL (grand median: 870 ng/mL and interquartile "reference" range: 520-1390 ng/mL). Covariates of potential clinical importance (up to 30% change in pharmacokinetic predicted by at least 1 model) included body weight, albumin, α1 acid glycoprotein, and white blood cell count. Various other covariates were included but were statistically not significant or seemed clinically less important or physiologically controversial. Concentration-response relationships had more importance below the average reference range and concentration-toxicity relationships above. Therapeutic drug monitoring-guided dosage adjustment seems justified for imatinib, but a formal predictive therapeutic range remains difficult to propose in the absence of prospective target concentration intervention trials. To evaluate the expectedness of a drug concentration measurement in practice, this review allows comparison of the measurement either to the average reference range or to a specific range accounting for individual patient characteristics. For future research, external PPK model validation or meta-model development should be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Metastatic melanoma has a poor prognosis with high resistance to chemotherapy and radiation. Recently, the anti-CTLA-4 antibody ipilimumab has demonstrated clinical efficacy, being the first agent to significantly prolong the overall survival of inoperable stage III/IV melanoma patients. A major aim of patient immune monitoring is the identification of biomarkers that predict clinical outcome. We studied circulating myeloid-derived suppressor cells (MDSC) in ipilimumab-treated patients to detect alterations in the myeloid cell compartment and possible correlations with clinical outcome. Lin(-) CD14(+) HLA-DR(-) monocytic MDSC were enriched in peripheral blood of melanoma patients compared to healthy donors (HD). Tumor resection did not significantly alter MDSC frequencies. During ipilimumab treatment, MDSC frequencies did not change significantly compared to baseline levels. We observed high inter-patient differences. MDSC frequencies in ipilimumab-treated patients were independent of baseline serum lactate dehydrogenase levels but tended to increase in patients with severe metastatic disease (M1c) compared to patients with metastases in skin or lymph nodes only (M1a), who had frequencies comparable to HD. Interestingly, clinical responders to ipilimumab therapy showed significantly less lin(-) CD14(+) HLA-DR(-) cells as compared to non-responders. The data suggest that the frequency of monocytic MDSC may be used as predictive marker of response, as low frequencies identify patients more likely benefitting from ipilimumab treatment. Prospective clinical trials assessing MDSC frequencies as potential biomarkers are warranted to validate these observations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Applied studies on the relationship between geography and technological innovation for United States, Germany, France and Italy have shown the positive effects that academic research exerts on the innovate output of firms at spatial level. The purpose of this paper is to look for new evidence on the possible effects of the university research for the case of Spain. To do so, within the framework of a Griliches-Jaffe knowledge production function, and using panel data and count models, the relationship between innovate inputs and patents, in the case of the Spanish regions is explored

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this paper is to explore the relative importance of each of Marshall's agglomeration mechanisms by examining the location of new manufacturing firms in Spain. In particular, we estimate the count of new firms by industry and location as a function of (pre-determined) local employment levels in industries that: 1) use similar workers (labor market pooling); 2) have a customer- supplier relationship (input sharing); and 3) use similar technologies (knowledge spillovers). We examine the variation in the creation of new firms across cities and across municipalities within large cities to shed light on the geographical scope of each of the three agglomeration mechanisms. We find evidence of all three agglomeration mechanisms, although their incidence differs depending on the geographical scale of the analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Applied studies on the relationship between geography and technological innovation for United States, Germany, France and Italy have shown the positive effects that academic research exerts on the innovate output of firms at spatial level. The purpose of this paper is to look for new evidence on the possible effects of the university research for the case of Spain. To do so, within the framework of a Griliches-Jaffe knowledge production function, and using panel data and count models, the relationship between innovate inputs and patents, in the case of the Spanish regions is explored

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A bidimensional array based on single-photon avalanche diodes for triggered imaging systems is presented. The diodes are operated in the gated mode of acquisition to reduce the probability to detect noise counts interfering with photon arrival events. In addition, low reverse bias overvoltages are used to lessen the dark count rate. Experimental results demonstrate that the prototype fabricated with a standard HV-CMOS process gets rid of afterpulses and offers a reduced dark count probability by applying the proposed modes of operation. The detector exhibits a dynamic range of 15 bits with short gated"on" periods of 10ns and a reverse bias overvoltage of 1.0V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need to move forward in the knowledge of the subatomic world has stimulated the development of new particle colliders. However, the objectives of the next generation of colliders sets unprecedented challenges to the detector performance. The purpose of this contribution is to present a bidimensional array based on avalanche photodiodes operated in the Geiger mode to track high energy particles in future linear colliders. The bidimensional array can function in a gated mode to reduce the probability to detect noise counts interfering with real events. Low reverse overvoltages are used to lessen the dark count rate. Experimental results demonstrate that the prototype fabricated with a standard HV-CMOS process presents an increased efficiency and avoids sensor blindness by applying the proposed techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Application of wild-type or genetically-modified bacteria to the soil environment entails the risk of dissemination of these organisms to the groundwater. To measure vertical transport of bacteria under natural climatic conditions, Pseudomonas fluorescens strain CHA0 was released together with bromide as a mobile tracer at the surface of large outdoor lysimeters. Two experiments, one starting in autumn 1993 and the other in spring 1994 were performed. Shortly after a heavy rainfall in late spring 1994, the released bacteria were detected for the first time in effluent water from the 2.5-m-deep lysimeters in both experiments, i.e. 210 d and 21 d, respectively, after inoculation. Only a 10−9 to 10−8 fraction of the inoculum was recovered as culturable cells in the effluent water, but a larger fraction of the CHA0 cells was in a non-culturable state as detected with immunofluorescence microscopy. As much as 50% of the mobile tracer percolated through the lysimeters, indicating that, compared with bromide, bacterial cells were retained in soil. In the second part of this study, persistence of CHA0 in groundwater microcosms consisting of lysimeter effluent water was studied for 380 d. Survival of the inoculant as culturable cells was better under anaerobic than under aerobic conditions. However, a large fraction of the cells became non-culturable in both cases. When the experiment was performed with filter-sterilized effluent water, the total count of introduced bacteria did not decline with time. In conclusion, the biocontrol strain was transported in low numbers to a potential groundwater level under natural climatic conditions, but could persist for an extended period in groundwater microcosms.