Avoiding sensor blindness in Geiger mode avalanche photodiode arrays fabricated in a conventional CMOS process


Autoria(s): Vilella Figueras, Eva; Diéguez Barrientos, Àngel
Contribuinte(s)

Universitat de Barcelona

Data(s)

31/08/2012

Resumo

The need to move forward in the knowledge of the subatomic world has stimulated the development of new particle colliders. However, the objectives of the next generation of colliders sets unprecedented challenges to the detector performance. The purpose of this contribution is to present a bidimensional array based on avalanche photodiodes operated in the Geiger mode to track high energy particles in future linear colliders. The bidimensional array can function in a gated mode to reduce the probability to detect noise counts interfering with real events. Low reverse overvoltages are used to lessen the dark count rate. Experimental results demonstrate that the prototype fabricated with a standard HV-CMOS process presents an increased efficiency and avoids sensor blindness by applying the proposed techniques.

Identificador

http://hdl.handle.net/2445/29404

Idioma(s)

eng

Publicador

Institute of Physics

Direitos

(c) Institute of Physics, 2011

info:eu-repo/semantics/openAccess

Palavras-Chave #Soroll electrònic #Metall-òxid-semiconductors complementaris #Col·lisions (Física nuclear) #Electronic noise #Complementary metal oxide semiconductors #Collisions (Nuclear physics)
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/acceptedVersion