The most native fruit trees are belonging to Myrtaceae family, which it have as main marketing potential their fruit. Despite the wide acceptance of the fruits of these native fruit cultura, the establishment of commercial orchards is still necessary, because if it prevails extraction in the forest. To start the cultivo in the orchard, the first point is on the mother plant choice, which should provide superior characteristics when compared to other genotypes. Then, it is necessary to choose the method to can produce satisfactory amount of seedlings and preferably without it to lose the mother plant characteristics. For this, it adopts the asexual thechniques, with option for grafting, cuttings and air layering. These techniques when tested with native fruits tree, it proved limiting in theses results, with this, it should to test other it to recommend its use, especially, those fruit native of higher potential as jabuticaba tree, pitanga tree, sete capote tree and araça amarelo tree. The aim of this study was to test the use of asexual propagation through mini-cuttings in these native fruit trees, according to the time of collection, the mini-cutting length and concentration of IBA, as well as, it to relate the results of rooting with tryptophan extracted at certain times. The work was carried out at Universidade Tecnológica Federal do Paraná – Câmpus Dois Vizinhos, Brazil. The samples were collected each two months. The mini-cutting were prepared with 6 or 8 cm, with a pair of leaves reduced to 25% of the original size. The mini-cuttings had their base immersed in liquid solution of indole-butyric acid (IBA) in the concentrations of 0, 3000 and 6000 mg L-1 and then were placed in tubes containing commercial substrate. The experimental design was completely randomized with factorial 2 x 3 x 6 (mini-cutting length x IBA concentration x time of collection), with four replications, it being each plot varied according to the amount of shoots obtained by period time. After 120 days, the rooting and callus formation (%), average number of roots per mini-cutting and the average length of the roots were evaluated. After 60 days of these evaluations, the survival of mini-cuttings rooted after transplant was evaluated. It was evaluated also the production of mini-cuttings of each size in each period time. At the end of the experiment it was evaluated the percentage of survival of mother plantlets. For analysis of tryptophan was used materials branches, leaves and twigs with leaves, taken from the materials used for the production of mini-cutting. It was recommended for hybrid jabuticaba tree the use mini-cutting with eight cm, treated with 6000 mg L-1 of IBA and collected in June. For jabuticaba tree of cabinho and araça amarelo tree the period for propagation by mini-cuttings should be in August, regardless of IBA concentration and length of the mini-cutting. In the jabuticaba tree sabara and sete capote tree is important to obtain more satisfactory results realized the collect in October or December, with the same independence of other levels tested in other factors. However, for sete capote tree should test other techniques to increase the efficiency of propagation. And with pitanga tree recommended to the collection in June, but with 6cm the application of 3000 mg L-1 of IBA and 8 cm with 6000 mg L-1 of IBA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ideal biomaterial for dental implants must have very high biocompatibility, which means that such materials should not provoke any serious adverse tissue response. Also, used metal alloys must have high fatigue resistance due the masticatory force and good corrosion resistance. These properties are rendered by using alpha and beta stabilizers, such as Al, V, Ni, Fe, Cr, Cu, Zn. Commercially pure titanium (TiCP) is used often for dental and orthopedic implants manufacturing. However, sometimes other alloys are employed and consequently it is essential to research the chemical elements present in those alloys that could bring prejudice for the health. Present work investigated TiCP metal alloys used for dental implant manufacturing and evaluated the presence of stabilizing elements within existing limits and standards for such materials. For alloy characterization and identification of stabilizing elements it was used EDXRF technique. This method allows to perform qualitative and quantitative analysis of the materials using the spectra of the characteristic X-rays emitted by the elements present in the metal samples. The experimental setup was based on two X- rays tubes (AMPTEK Mini X model with Ag and Au targets), a X-123SDD detector (AMPTEK) and a 0.5mm Cu collimator, developed due to the sample characteristics. The other experimental setup used as a complementary technique is composed of an X-ray tube with a Mo target, collimator 0.65mm and XFlash (SDD) detector - ARTAX 200 (BRUKER). Other method for elemental characterization by energy dispersive spectroscopy (EDS) applied in present work was based on Scanning Electron Microscopy (SEM) EVO® (Zeeis). This method also was used to evaluate the surface microstructure of the sample. The percentual of Ti obtained in the elementary characterization was among 93.35 ± 0.17% and 95.34 ± 0.19 %. These values are considered below the reference limit of 98.635% to 99.5% for TiCP, established by Association of metals centric materials engineers and scientists Society (ASM). The presence of elements Al and V in all samples also contributed to underpin the fact that are not TiCP implants. The values for Al vary between 6.3 ± 1.3% and 3.7 ± 2.0% and for V, between 0.26 ± 0.09% and 0.112 ± 0.048%. According to the American Society for Testing and Materials (ASTM), these elements should not be present in TiCP and in accordance with the National Institute of Standards and Technology (NIST), the presence of Al should be <0.01% and V should be of 0.009 ± 0.001%. Obtained results showed that implant materials are not exactly TiCP but, were manufactured using Ti-Al-V alloy, which contained Fe, Ni, Cu and Zn. The quantitative analysis and elementary characterization of experimental results shows that the best accuracy and precision were reached with X-Ray tube with Au target and collimator of 0.5 mm. Use of technique of EDS confirmed the results of EDXRF for Ti-Al-V alloy. Evaluating the surface microstructure by SEM of the implants, it was possible to infer that ten of the thirteen studied samples are contemporaneous, rough surface and three with machined surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de Estágio para a obtenção do grau de Mestre em Ensino da Música

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presence and concentrations of radionuclides could be as a result of natural and human activities. This study examined the associations and differences among soil, sediment and water specific activities of long-lived radioactive element (LLRE). Gamma spectroscopy was used to measure the concentration of the LLRE along the Mini Okoro/Oginigba Creek, Port Harcourt. Specific activities of three selected LLRE were derived. Correlation analysis was carried out to examine associations among the specific activities across different substrates. A strong and a significant negative correlation exists between the specific activities of Water 40K and Soil 232Th (r =-0.721, p<0.05); Water 238U and Soil 238U (r = -0.717, p<0.05) and Water 40K and Sediment 238U (r=-0.69, p<0.05). Comparison using Mann-Whitney U test shows that, soil and sediment are similar in their specific activities with Z values of -0.408, -1.209 and -1.021 (p > 0.05) for 40K, 232Th and 238U respectively. The concentration of solid samples (soil and sediment) is different from the liquid (water) samples. These associations can be attributed to some specific underlying factors. And in other to understand them there is need for more studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To investigate the effect of implant-abutment angulation and crown material on stress distribution of central incisors. Finite element method was used to simulate the clinical situation of a maxillary right central incisor restored by two different implant-abutment angulations, 15° and 25°, using two different crown materials (IPS E-Max CAD and zirconia). Methods: Two 3D finite element models were specially prepared for this research simulating the abutment angulations. Commercial engineering CAD/CAM package was used to model crown, implant abutment complex and bone (cortical and spongy) in 3D. Linear static analysis was performed by applying a 178 N oblique load. The obtained results were compared with former experimental results. Results: Implant Von Mises stress level was negligibly changed with increasing abutment angulation. The abutment with higher angulation is mechanically weaker and expected to fail at lower loading in comparison with the steeper one. Similarly, screw used with abutment angulation of 25° will fail at lower (about one-third) load value the failure load of similar screw used with abutment angulated by 15°. Conclusions: Bone (cortical and spongy) is insensitive to crown material. Increasing abutment angulation from 15° to 25°, increases stress on cortical bone by about 20% and reduces it by about 12% on spongy bone. Crown fracture resistance is dramatically reduced by increasing abutment angulation. Zirconia crown showed better performance than E-Max one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumo: Diversos surtos de Salmonella ocasionados pelo consumo de tomate contaminados com este micro-organismo têm sido relatados ultimamente, o que torna primordial a investigação sobre a presença desse patógeno nesse alimento. Métodos que permitam a avaliação rápida da presença de Salmonella em alimentos são de suma importância. O objetivo desse estudo foi comparar o método tradicional da Food and Drug Administration - Bacteriologycal Analytical Manual (FDA-BAM) com um método rápido da mini Vitek Immuno Diagnostic System Assay (Mini?Vidas-SLM)-bioMérieux, para detecção de Salmonella Brazil inoculada artificialmente na superfície de tomates. Foram analisadas 215 amostras de tomates inoculadas artificialmente com Salmonella Brazil com níveis de inóculos variando de 0,4 a 940 UFC/tomate. Os resultados obtidos mostraram que os métodos estudados apresentaram uma ótima concordância entre si, para todas as faixas de inóculo analisadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To improve the effectiveness and reduce the systemic side effects of methylprednisolone in traumatic spinal injuries, its polymeric implants were prepared using chitosan and sodium alginate as the biocompatible polymers. Methods: Implants of methylprednisolone sodium succinate (MPSS) were prepared by molding the drug-loaded polymeric mass obtained after ionotropic gelation method. The prepared implants were evaluated for drug loading, in vitro drug release and in vivo performance in traumatic spinal-injury rat model with paraplegia. Results: All the implant formulations were light pale solid matrix with smooth texture. Implants showed 86.56 ± 2.07 % drug loading. Drug release was 89.29 ± 1.25 % at the end of 7 days. Motor function was evaluated in traumatic spinal injury-induced rats in terms of its movement on the horizontal bar. At the end of 7 days, the test group showed the activity score (4.75 ± 0.02) slightly higher than that of standard (4.62 ± 0.25), but the difference was not statistically different (p > 0.05). Conclusion: MPSS-loaded implants produces good recovery in traumatic spinal-injury rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast cancer is the most common cancer among women in Malaysia. Therefore, it is important for the public to be educated on breast cancer and to know the steps that need to be taken to detect it early. Healthcare providers are in a unique position to provide public health education due to their good knowledge of health issues and their roles in healthcare. A systematic review of studies conducted from 2008 till 2015 was undertaken to analyze the knowledge, attitudes and behavior of Malaysian healthcare providers regarding breast cancer, in an attempt to obtain an overall picture of how wellequipped the healthcare providers are to provide optimal breast cancer education, and to ascertain their perceptions and actual involvement in such education. The systematic review was conducted via a primary search of various databases and journal websites, and a secondary search of references cited in eligible studies. Criteria for eligibility include studies conducted in Malaysia and published from the year 2008 to 2015, and written in English language. A total of fifteen articles were identified and reviewed but only two studies were eligible for this review. The findings suggest that future and current Malaysian healthcare providers have moderate knowledge of breast cancer, showed a positive disposition towards involvement in breast cancer education, but displayed poor involvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El presente trabajo se ha concebido bajo un carácter didáctico y con la intención de ser difundido y utilizado, dirigido a estudiantes, profesores y aquellos que sientan deseo de incursionar en este campo interesante. El baloncesto es un deporte practicado en edades tempranas, no está enfocado en la competitividad sino encausado a adquirir fundamentos: técnicos, tácticos, individuales y colectivos con una descripción detallada del proceso de aprendizaje y las destrezas básicas; iniciando de lo sencillo a lo complejo, a la iniciación del juego y sus reglas, acompañados de una disciplina deportiva de colaboración, compañerismo, responsabilidad, cooperación, alimentación, de higiene, de buenos hábitos, alejados del alcohol y las drogas, que afectan al normal desarrollo bio-psico-social-afectivo del individuo. Con la transición del minibaloncesto al baloncesto en la selección de la escuela Fiscomisional Sor Teresa Valsé en la categoría intermedia comprendida en las edades de 12 a 14 años realizado en los meses de agosto 2015 a mayo 2016, se pretendió poner al alcance de las niñas todas las ventajas y valores educativos del baloncesto, de tal manera que no se contraríe su naturaleza, posibilidades, intereses, ni exija esfuerzos incompatibles con la edad de las participantes. En consecuencia la transición del minibaloncesto al baloncesto repercute en forma positiva en el normal desarrollo de las niñas de estas edades, tanto en lo físico, técnico-táctico, psicológico y social, así como también este trabajo refleja el desarrollo y adquisición de habilidades, destrezas y el modelo sobre el cual se implementó cada uno de los mismos para alcanzar los resultados esperados de esta investigación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, semi spontaneous samples of spoken language are analysed. Participants are 30 children with severe or profound deafness who employ digital hearing-aid or cochlear implant. The main goal is to find out the strengths and weaknesses of their grammatical skills in order to employ that information in dessigning speech therapy programs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, a series of Ti-xNb-yMo (x = 5-40 wt.% in 5 wt.% increments; and y = 3, 5, 10 wt%) alloys were fabricated by powder metallurgy and studied with respect to their microstructures, compressive mechanical properties and hardness. Increases in Nb and Mo content led to decreases in compressive and yield strengths, elastic modulus and hardness of the sintered alloys. Among the studied alloys, Ti-10Nb-3Mo alloy exhibited the optimum combination of strength and ductility. Alloys with a lower amount of Nb (≤ 25 wt.%) and Mo (≤ 5 wt.%) developed Widmanstätten structure, while further increase in Nb and Mo additions led to the microstructure predominantly consisting of β phase with varying regions of α + β phase. The effects of sintering temperature on elastic modulus and hardness were also investigated for Ti-xNb-3Mo alloys.