982 resultados para MODULES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The key challenges for achieving flexibility in flexible mode programmes in engineering and technology include: the integration of the explicit and implicit content in potentially disparate and isolated study modules across the whole programme curriculum; ensuring the validity and consistency of policies for granting students advanced standing based on recognition for prior learning and workplace experience; developing learning materials and experiences that cater for a wide and diverse audience, while at the same time offering relevance to the individual student in their own context; creating innovative communication environments that bring remote students into both the directed and the discursive discussion that are an important part of the learning process; and the financial and resourcing sustainability of the development, maintenance and delivery of high quality flexible mode  engineering and technology study programmes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Four treatments including three different concentrations of pineapple solution (I %, 3%, 5%) and the traditional method (salt/urea/tannin solutions) were used to eliminate egg stickiness of common carp. With the traditional method, fertilization and hatching rates were 74.5% ± 1.2 and 70.2% ± 1.1, respectively. The highest fertilization rate (89.3% ± 0.7) and hatching rate (86.6% ± 1.4) were found with treatment of 1% pineapple juice solution and was significantly different from those obtained with other treatments (P<0.05). Using pineapple juice for desticking common carp eggs also reduced the time of egg handling from almost one hour required with the traditional method, to about three minutes, as well as increasing fertilization and hatching rate under hatchery conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A distributed database system is subject to site failure and link failure. This paper presents a reactive system approach to achieving fault tolerance in such a system. The reactive system concepts are an attractive paradigm for system design, development and maintenance because it separates policies from mechanisms. In the paper we give a solution using different reactive modules to implement the fault tolerant policies and the failure detection mechanisms. The solution shows that they can be separated without impact on each other; thus the system can adapt to constant changes in environments and user requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To outline the development, structure, data assumptions, and application of an Australian economic model for stroke (Model of Resource Utilization, Costs, and Outcomes for Stroke [MORUCOS]). Methods: The model has a linked spreadsheet format with four modules to describe the disease burden and treatment pathways, estimate prevalence-based and incidence-based costs, and derive life expectancy and quality of life consequences. The model uses patient-level, community-based, stroke cohort data and macro-level simulations. An interventions module allows options for change to be consistently evaluated by modifying aspects of the other modules. To date, model validation has included sensitivity testing, face validity, and peer review. Further validation of technical and predictive accuracy is needed. The generic pathway model was assessed by comparison with a stroke subtypes (ischemic, hemorrhagic, or undetermined) approach and used to determine the relative cost-effectiveness of four interventions. Results: The generic pathway model produced lower costs compared with a subtypes version (total average first-year costs/case AUD$15,117 versus AUD$17,786, respectively). Optimal evidence-based uptake of anticoagulation therapy for primary and secondary stroke prevention and intravenous thrombolytic therapy within 3 hours of stroke were more cost-effective than current practice (base year, 1997). Conclusions: MORUCOS is transparent and flexible in describing Australian stroke care and can effectively be used to systematically evaluate a range of different interventions. Adjusting results to account for stroke subtypes, as they influence cost estimates, could enhance the generic model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The object-oriented finite element method (OOFEM) has attracted the attention of many researchers. Compared with the traditional finite element method, OOFEM software has the advantages of maintenance and reuse. Moreover, it is easier to expand the architecture to a distributed one. In this paper, we introduce a distributed architecture of a object-oriented finite element preprocessor. A comparison between the distributed system and the centralised system shows that the former, presented in the paper, greatly improves the performance of mesh generation. Other finite element analysis modules could be expanded according to this architecture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A distributed database system is subject to site failure and link failure. This paper presents a reactive system approach to achieving the fault-tolerance in such a system. The reactive system concepts are an attractive paradigm for system design, development and maintenance because it separates policies from mechanisms. In the paper we give a solution using different reactive modules to implement the fault-tolerant policies and the failure detection mechanisms. The solution shows that they can be separated without impact on each other thus the system can adapt to constant changes in user requirements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we will sketch out and briefly analyse a recurring and central theme throughout the reality TV series Jamie’s Kitchen – that of passion:

• Passion for food;
• Being passionate as you construct and present yourself;
• Being passionate about your work;
• Having a go, getting passionate in a training environment which compresses years of training into months of training.

In this series the high profile celebrity chef Jamie Oliver set out to transform a group of unemployed young Londoners into the enterprising, entrepreneurial, ideal worker of 21st century flexible capitalism. This series, and its figure of the entrepreneurial, risk taking, small businessman (who in this instance is also a global celebrity brand) seeking to develop similar dispositions and behaviours in a workforce that initially does not display such character features, illuminates, and provides a means to explore, key features of new work regimes. The emphasis on passion in the analysis – which draws on Foucault’s later work on the care of the self - allows us to connect to discussions about education and training that highlight the passionate/pleasure dimensions of pedagogy. These elements of education and training very rarely get discussed in a vocational education and training environment which is largely driven by modules/competencies/outcomes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is challenging to teach supply chain management (SCM) practices and technologies to tertiary students. This is because the back-end and highly dynamic processes can be difficult to visualise and because many students only have experience as a consumer. This paper reports the authors' experiences using a variety of multimedia and interactive enhancements we have used with our SCM learning materials: SCM business simulations; online learning modules with interactive games; and multimedia resources such as videos and animations. The paper also provides an overview of the challenges faced using these approaches, which gives rise to a number of future research opportunities. It also argues that these approaches can support educators with any epistemological view of learning. The paper makes a significant contribution because there has been little if any research into the use of these approaches in SCM education.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is a result of a fruitful cooperation between the computer science and the dental diagnosis experiences. The study presents a new approach of applying computer algorithms to radiographic images of dental implantation used for bone regeneration. We focus here only on the contribution of the computer assistance to the clinical research as the periodontal therapy is beyond the scope of this paper. The proposed system is based on a pattern recognition approach, directed to recognize density changes in the intra-bony affected areas of patients. It comprises different modules with new algorithms specially designed to treat the patients’ radiographic images more accurately. The system includes digitizing, detecting the complicated region of interest (ROI), defining reference area to correct any projection discrepancy of the follow up images, and finally to extract the distinguishing features of the ROI as a basis for determining the rate of new bone density accumulation. This study is applied to two typical dental cases for a patient who received two different operations. The results are very encouraging and more accurate than traditional techniques reported before.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fishes of the genus Acanthopagrus are found throughout the coastal waters of Asia and Australia with several species being of commercial significance. In this study, genetic comparisons are made between widely disjunct populations of Acanthopagrus australis (Günther) from Australian and Taiwanese waters and among samples of A. butcheri (Munro), A. berda, (Forskal), A schlegeli (Day) and A. latus (Houttuyn) using mitochondrial DNA sequences obtained from the control region. The mean interspecific pairwise sequence divergence for all species is 17%, while the divergence between A. australis from Australia and that of Taiwan is slightly larger at 18%. These values are considerably higher than those found for intraspecific control region comparisons in some fish species. Phylogenetic analyses indicate that A. australis from Australia is more closely related to the Australian species A. butcheri than to A. australis from Taiwan. These findings suggest that the northern and southern hemisphere forms of A. australis are not monophyletic, with the former possibly representing a new undescribed species of Acanthopagrus.