988 resultados para Capacitively coupled contactless conductivity detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The passive haemagglutination (PHA) test, enzyme-linked immunosorbent assay (ELISA) and the dot enzyme-immunosorbent assay (DOT-ELISA) were used to detect the levels of IgG antibodies against the Fraction 1 (F1) antigen of Yersinia pestis in sera of plague-infected patients from Northeast Brazil. Twenty three selected PHA-positive sera of subjects with bacteriological confirmation of plague were also positive in the DOT-ELISA but only 19 were detected by the conventional ELISA technique. Another group of 186 serum samples from subjects diagnosed as plague-infected by clinical and epidemiological parameters, but PHA-negative, were screened with DOT-ELISA and 11 gave positive results. The specificity of the assays on the serological detection of plague was confirmed in inhibition tests using purified F1 antigen. These results suggest that DOT-ELISA can be an useful, simple and more sensitive alternative for the serodiagnosis of plague in Northeast Brazil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunofluorescence and immunoperoxidase test directed against early viral antigens, and DNA-DNA hybridization were compared with viral isolation for their abilities to detect Cytomegalovirus (CVM) in the urine of 89 HIV infected patients. From the 100 urine samples collected, 70 were found positive by at least one method. Considering viral isolation as the "gold standard" technique, immunofluorescence and immunoperoxidase had a sensitivity of 92.3% and88% respectively, with a specificity in both cases of 95%. DNA-DNA hybridization showed a sensitivity of 90% but with lower (60%) specificity. All of the three assays were effective in detecting CVM from urine and the technical advantage of each is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’objectiu principal del projecte és el de classificar escenes de carretera en funció del contingut de les imatges per així poder fer un desglossament sobre quin tipus de situació tenim en el moment. És important que fixem els paràmetres necessaris en funció de l’escenari en què ens trobem per tal de treure el màxim rendiment possible a cada un dels algoritmes. La seva funcionalitat doncs, ha de ser la d’avís i suport davant els diferents escenaris de conducció. És a dir, el resultat final ha de contenir un algoritme o aplicació capaç de classificar les imatges d’entrada en diferents tipus amb la màxima eficiència espacial i temporal possible. L’algoritme haurà de classificar les imatges en diferents escenaris. Els algoritmes hauran de ser parametritzables i fàcilment manejables per l’usuari. L’eina utilitzada per aconseguir aquests objectius serà el MATLAB amb les toolboxs de visió i xarxes neuronals instal·lades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new serological assay dot-dye-immunoassay (dot-DIA) was evaluated for the diagnosis of schistosomiasis mansoni. This method consist of four steps: (a) biding of antigens to a nitrocellulose membrane (NC); (b) blocking of free sites of the NC; (c) incubation in specific primary antibody; (d) detection of primary antibody reactivity by color development using second antibody coupled to textile dyes. Sera from 82 individuals, 61 with Schistosoma mansoni eggs in the stool and 21 stool negative were tested by ELISA, dot-ELISA, and dotDIA. A high level of agreement between the methods tested was observed for all sera tested: ELISA x dot-ELISA: 95.1%, ELISA x dot-DIA: 92.7% and dot-ELISA x dot-DIA: 97.6%. In this study, dot-DIA proved to be a feasible, sensitive, rapid and practical test for the diagnosis of shcistosomiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present report describes an alternative method for in vitro detection of HIV-1 -specific antibody secretion in 24h of culture employing as stimulant of peripheral blood mononuclear cells the disrupted inactivated whole virus adsorbed onto microwells in a commercial ELISA kit plates. The results obtained from this technique have showed high sensitivity and specificity since it was capable of detecting HIV-1 infection early after birth. There were neither false-positivity nor false-negativity when blood samples obtained from HIV-1 seronegative asymptomatic individuals, and HIV-1 seropositive adult patients were analized. This rapid, low cost, simple, highly sensitive and specific assay can be extremely useful for early diagnosis of pediatric HIV infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Distinguishing postmortem gas accumulations in the body due to natural decomposition and other phenomena such as gas embolism can prove a difficult task using purely Multi-Detector Computed Tomography (MDCT). The Radiological Alteration Index (RAI) was created with the intention to be able to identify bodies undergoing the putrefaction process based on the quantity of gas detected within the body. The flaw in this approach is the inability to absolutely determine putrefaction as the origin of gas volumes in cases of moderate alteration. The aim of the current study is to identify percentage compositions of O2, N2, CO2 and the presence of gases such as H2 and H2S within these sampling sites in order to resolve this complication. Materials and methods: All cases investigated in our University Center of Legal Medicine are undergoing a Post-Mortem Computed Tomography (PMCT)-scan before external examination or autopsy as a routine investigation. In the obtained images, areas of gas were characterized as 0, I, II or III based on the amount of gas present according to the RAI (1). The criteria for these characterizations were dependent of the site of gas, for example thoracic and abdominal cavities were graded as I (1 - 3cm gas), II (3 - 5cm gas) and III (>5cm gas). Cases showing gaseous sites with grade II or III were selected for this study. The sampling was performed under CT-guidance to target the regions to be punctured. Luer-lock PTFE syringes equipped with a three-way valve and needles were used to sample the gas directly (2). Gaseous samples were then analysed using gas chromatography coupled to a thermal conductivity detector (GC-TCD). The components present in the samples were expressed as a percentage of the overall gas present. Results: Up to now, we have investigated more than 40 cases using our standardized procedure for sampling and analysis of gas. O2, N2 and CO2 were present in most samples. The following distributions were found to correlate to gas origins of gas embolism/scuba diving accidents, trauma and putrefaction: ? Putrefaction → O2 = 1 - 5%; CO2 > 15%; N2 = 10 - 70%; H2 / H2S / CH4 variable presence ? Gas embolism/Scuba diving accidents → O2 and N2= varying percentages; CO2 > 20% ? Trauma → O2 = small percentage; CO2 < 15%; N2 > 65% H2 and H2S indicated levels of putrefaction along with methane which can also gauge environmental conditions or conditions of body storage/burial. Many cases showing large RAI values (advanced alteration) did reveal a radiological diagnosis which was in concordance with the interpretation of the gas composition. However, in certain cases (gas embolism, scuba divers) radiological interpretation was not possible and only chemical gas analysis was found to lead to the correct diagnosis, meaning that it provided complementary information to the radiological diagnosis. Conclusion: Investigation of postmortem gases is a useful tool to determine origin of gas generation which can aid the diagnosis of the cause of death. Levels of gas can provide information on stage of putrefaction and help to perform essential medico-legal diagnosis such as vital gas embolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work covers two aspects. First, it generally compares and summarizes the similarities and differences of state of the art feature detector and descriptor and second it presents a novel approach of detecting intestinal content (in particular bubbles) in capsule endoscopy images. Feature detectors and descriptors providing invariance to change of perspective, scale, signal-noise-ratio and lighting conditions are important and interesting topics in current research and the number of possible applications seems to be numberless. After analysing a selection of in the literature presented approaches, this work investigates in their suitability for applications information extraction in capsule endoscopy images. Eventually, a very good performing detector of intestinal content in capsule endoscopy images is presented. A accurate detection of intestinal content is crucial for all kinds of machine learning approaches and other analysis on capsule endoscopy studies because they occlude the field of view of the capsule camera and therefore those frames need to be excluded from analysis. As a so called “byproduct” of this investigation a graphical user interface supported Feature Analysis Tool is presented to execute and compare the discussed feature detectors and descriptor on arbitrary images, with configurable parameters and visualized their output. As well the presented bubble classifier is part of this tool and if a ground truth is available (or can also be generated using this tool) a detailed visualization of the validation result will be performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a repetitive DNA probe for Babesia bigemina was reviewed. The original plasmid (p(Bbi)16) contained an insert of B. bigemina DNA of approximately 6.3 kb. This probe has been evaluated for specificityand analytical sensitivity by dot hybridization with isolates from Mexico, the Caribbean region and Kenya. A partial restriction map has been constructed and insert fragments have been subcloned and utilized as specific DNA probes. A comparison of 32P labelled and non-radioactive DNA probes was presented. Non-radioctive detection systems that have been used include digoxigenin dUTP incorporation, and detection by colorimetric substrate methods. Derivatives from the original DNA probe have been utilized to detect B. bigemina infection in a) experimentally inoculated cattle, b) field exposed cattle, c) infected Boophilus microplus ticks, and d) the development of a PCR amplification system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study was performed to assess the interlaboratory reproducibility of the molecular detection and identification of species of Zygomycetes from formalin-fixed paraffin-embedded kidney and brain tissues obtained from experimentally infected mice. Animals were infected with one of five species (Rhizopus oryzae, Rhizopus microsporus, Lichtheimia corymbifera, Rhizomucor pusillus, and Mucor circinelloides). Samples with 1, 10, or 30 slide cuts of the tissues were prepared from each paraffin block, the sample identities were blinded for analysis, and the samples were mailed to each of seven laboratories for the assessment of sensitivity. A protocol describing the extraction method and the PCR amplification procedure was provided. The internal transcribed spacer 1 (ITS1) region was amplified by PCR with the fungal universal primers ITS1 and ITS2 and sequenced. As negative results were obtained for 93% of the tissue specimens infected by M. circinelloides, the data for this species were excluded from the analysis. Positive PCR results were obtained for 93% (52/56), 89% (50/56), and 27% (15/56) of the samples with 30, 10, and 1 slide cuts, respectively. There were minor differences, depending on the organ tissue, fungal species, and laboratory. Correct species identification was possible for 100% (30 cuts), 98% (10 cuts), and 93% (1 cut) of the cases. With the protocol used in the present study, the interlaboratory reproducibility of ITS sequencing for the identification of major Zygomycetes species from formalin-fixed paraffin-embedded tissues can reach 100%, when enough material is available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Leishmania donovani-complex specific DNA probe was usedto confirm the widespread dissemination of amastigotes in apparently normal skinof dogs with canine visceral leishmaniasis. When Lutzomyia longipalpis were fed on abnormal skin of five naturally infected dogs 57 of 163 (35 per cent) fliesbecame infected: four of 65 flies (6 per cent) became infected when fed on apparently normal skin. The bite of a single sandfly that had fed seven days previouslyon a naturally infected dog transmitted the infection to a young dog from a non-endemic area. Within 22 days a lesion had developed at the site of the infectivebite (inner ear): 98 days after infection organisms had not disseminated throughout the skin, bone marrow, spleen or liver and the animal was still serologically negative by indirect immunofluorescence and dot-enzyme-linked immunosorbent assay. When fed Lu. longipalpis were captured from a kennel with a sick dog known to be infected, 33 out of 49 (67 per cent) of flies contained promastigotes. In contrast only two infections were detected among more than 200 sandflies captured in houses. These observations confirm the ease of transmissibility of L.chagasi from dog to sandfly to dog in Teresina. It is likely that canine VL is the major source of human VL by the transmission route dog-sandfly-human. the Lmet2 DNA probe was a useful epidemiological tool for detecting L. chagasi in sandflies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The widespread misuse of drugs has increased the number of multiresistant bacteria, and this means that tools that can rapidly detect and characterize bacterial response to antibiotics are much needed in the management of infections. Various techniques, such as the resazurin-reduction assays, the mycobacterial growth indicator tube or polymerase chain reaction-based methods, have been used to investigate bacterial metabolism and its response to drugs. However, many are relatively expensive or unable to distinguish between living and dead bacteria. Here we show that the fluctuations of highly sensitive atomic force microscope cantilevers can be used to detect low concentrations of bacteria, characterize their metabolism and quantitatively screen (within minutes) their response to antibiotics. We applied this methodology to Escherichia coli and Staphylococcus aureus, showing that live bacteria produced larger cantilever fluctuations than bacteria exposed to antibiotics. Our preliminary experiments suggest that the fluctuation is associated with bacterial metabolism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In hyperdiploid acute lymphoblastic leukaemia (ALL), the simultaneous occurrence of specific aneuploidies confers a more favourable outcome than hyperdiploidy alone. Interphase (I) FISH complements conventional cytogenetics (CC) through its sensitivity and ability to detect chromosome aberrations in non-dividing cells. To overcome the limits of manual I-FISH, we developed an automated four-colour I-FISH approach and assessed its ability to detect concurrent aneuploidies in ALL. I-FISH was performed using centromeric probes for chromosomes 4, 6, 10 and 17. Parameters established for automatic nucleus selection and signal detection were evaluated (3 controls). Cut-off values were determined (10 controls, 1000 nuclei/case). Combinations of aneuploidies were considered relevant when each aneuploidy was individually significant. Results obtained in 10 ALL patients (1500 nuclei/patient) were compared with those by CC. Various combinations of aneuploidies were identified. All clones detected by CC were observed by I-FISH. I-FISH revealed numerous additional abnormal clones, ranging between 0.1 % and 31.6%, based on the large number of nuclei evaluated. Four-colour automated I-FISH permits the identification of concurrent aneuploidies of prognostic significance in hyperdiploid ALL. Large numbers of cells can be analysed rapidly by this method. Owing to its high sensitivity, the method provides a powerful tool for the detection of small abnormal clones at diagnosis and during follow up. Compared to CC, it generates a more detailed cytogenetic picture, the biological and clinical significance of which merits further evaluation. Once optimised for a given set of probes, the system can be easily adapted for other probe combinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Among young people, about one in three females and one in five males report experiencing emotional distress but 65-95% of them do not receive help from health professionals. AIM: To assess the differences among young people who seek help and those who do not seek help for their psychological problems, considering the frequency of consultations to their GP and their social resources. DESIGN OF STUDY: School survey. SETTING: Post-mandatory school. METHOD: Among a Swiss national representative sample of 7429 students and apprentices (45.6% females) aged 16-20 years, 1931 young people reported needing help for a problem of depression/sadness (26%) and were included in the study. They were divided into those who sought help (n = 256) and those who did not (n = 1675), and differences between them were assessed. RESULTS: Only 13% of young people needing help for psychological problems consulted for that reason and this rate was positively associated with the frequency of consultations to the GP. However, 80% of young people who did not consult for psychological problems visited their GP at least once during the previous year. Being older or a student, having a higher depression score, or a history of suicide attempt were linked with a higher rate of help seeking. Moreover, confiding in adults positively influenced the rate of help seeking. CONCLUSION: The large majority of young people reporting psychological problems do not seek help, although they regularly consult their GP. While young people have difficulties in tackling issues about mental health, GPs could improve the situation by systematically inquiring about this issue.