983 resultados para Underground storage tanks
Resumo:
This paper presents a novel analysis of the utilisation of small grid scale energy storage to mitigate negative system operational impacts due to high penetrations of wind power. This was investigated by artificially lowering the minimum stable generation level of a gas thermal generating unit coupled to a storage device over a five hour storage charging window using a unit commitment and economic dispatch model. The key findings of the analysis were a 0.18% reduction in wind curtailment, a 2.35 MW/min reduction in the ramping rate required to be met by all generators in the test system during a representative period and a total generation cost reduction of €6.5 million.
Resumo:
Public–private partnerships (PPPs) have become common inter-organizational arrangements associated with “new public management.” Discussion about their effective operation has often focused on successful management methods, with less discussion about how these arrangements specifically overcome obstacles and problems. In this article, we seek to address this deficiency in the literature by analyzing the conflict management system employed within the London Underground PPP (when it was still in operation). We conclude by identifying several lessons from this case that we believe should inform the design of such systems, one of which is the role of knowledge management.
Resumo:
Samples of fine-grained channel bed sediment and overbank floodplain deposits were collected along the main channels of the Rivers Aire (and its main tributary, the River Calder) and Swale, in Yorkshire, UK, in order to investigate downstream changes in the storage and deposition of heavy metals (Cr, Cu, Pb, Zn), total P and the sum of selected PCB congeners, and to estimate the total storage of these contaminants within the main channels and floodplains of these river systems. Downstream trends in the contaminant content of the <63 μm fraction of channel bed and floodplain sediment in the study rivers are controlled mainly by the location of the main sources of the contaminants, which varies between rivers. In the Rivers Aire and Calder, the contaminant content of the <63 μm fraction of channel bed and floodplain sediment generally increases in a downstream direction, reflecting the location of the main urban and industrialized areas in the middle and lower parts of the basin. In the River Swale, the concentrations of most of the contaminants examined are approximately constant along the length of the river, due to the relatively unpolluted nature of this river. However, the Pb and Zn content of fine channel bed sediment decreases downstream, due to the location of historic metal mines in the headwaters of this river, and the effect of downstream dilution with uncontaminated sediment. The magnitude and spatial variation of contaminant storage and deposition on channel beds and floodplains are also controlled by the amount of <63 μm sediment stored on the channel bed and deposited on the floodplain during overbank events. Consequently, contaminant deposition and storage are strongly influenced by the surface area of the floodplain and channel bed. Contaminant storage on the channel beds of the study rivers is, therefore, generally greatest in the middle and lower reaches of the rivers, since channel width increases downstream. Comparisons of the estimates of total storage of specific contaminants on the channel beds of the main channel systems of the study rivers with the annual contaminant flux at the catchment outlets indicate that channel storage represents <3% of the outlet flux and is, therefore, of limited importance in regulating that flux. Similar comparisons between the annual deposition flux of specific contaminants to the floodplains of the study rivers and the annual contaminant flux at the catchment outlet, emphasise the potential importance of floodplain deposition as a conveyance loss. In the case of the River Aire the floodplain deposition flux is equivalent to between ca. 2% (PCBs) and 36% (Pb) of the outlet flux. With the exception of PCBs, for which the value is ≅0, the equivalent values for the River Swale range between 18% (P) and 95% (Pb). The study emphasises that knowledge of the fine-grained sediment delivery system operating in a river basin is an essential prerequisite for understanding the transport and storage of sediment-associated contaminants in river systems and that conveyance losses associated with floodplain deposition exert an important control on downstream contaminant fluxes and the fate of such contaminants. © 2003 Elsevier Science Ltd. All rights reserved.
Resumo:
A novel strategy for the controlled synthesis of 2D MoS<inf>2</inf>/C hybrid nanosheets consisting of the alternative layer-by-layer interoverlapped single-layer MoS<inf>2</inf> and mesoporous carbon (m-C) is demonstrated. Such special hybrid nanosheets with a maximized MoS<inf>2</inf>/m-C interface contact show very good performance for lithium-ion batteries in terms of high reversible capacity, excellent rate capability, and outstanding cycling stability.
Resumo:
The effect of different pressure levels (500 and 600. MPa for 1. min at ambient temperature) on lasagne ready meal as a means of increasing the safety and shelf life during storage at refrigeration (4. °C) and abuse temperature (8. °C) was investigated. High-pressure processing (500 and 600. MPa for 1. min) was able to significantly reduce the total aerobic and lactic acid bacteria counts and prolong the microbiological shelf life of lasagne at both refrigeration and abuse temperatures. Pressure at 600. MPa was a useful tool to reduce the safety risks associated with Staphylococcus aureus and Listeria monocytogenes. However, abuse storage temperature facilitated the recovery of L. monocytogenes towards the end of storage. Organoleptic evaluation revealed that HPP did not negatively influence the quality attributes of lasagne and prolonged its organoleptic shelf life. HPP treatment can serve as a useful additional step to enhance safety and increase the shelf life of multicomponent ready meals, such as lasagne. Industrial relevance: The ready meals sector of the food industry has been experiencing increasing growth in the past years. This comprehensive study explored the effects of HPP on a very popular multicomponent ready meal i.e., lasagne after treatment and during storage. The results showed that HPP can be successfully applied to lasagne ready meals to decrease the risk from S. aureus and L. monocytogenes and also significantly prolong its shelf life without affecting its organoleptic properties. The utilisation of HPP by the industry can significantly increase safety and also provide the opportunity for this product to reach markets further away.
Resumo:
We used glycine betaine (5–20% w/v) for blanching green peas (100°C, 60 s), and their subsequent freezing and storage (–20°C, 90 days). Blanching after the addition of glycine betaine at ≥10% (w/v) followed by a 90 day storage period which resulted in the most desirable outcome: higher vitamin C levels, a superior green color, enhanced organoleptic quality and texture, and improved retention of peroxidase and lipoxygenase activity relative to control peas (no glycine betaine added). Microscopic characterizations of control and treated peas revealed that glycine betaine acts as a cryoprotectant which maintains cellular integrity. Glycine betaine (10% w/v) could be used commercially for production of frozen peas with better quality attributes.