996 resultados para Digital Reconstruction
Resumo:
Aortic root (AoR) components provide synchronous and precise 3D deformation of the aortic root during the cardiac cycle in order to ensure closure and opening of the three leaflets over a lifetime. Any deviation from the natural 3D morphology, such as with AoR annulus dilatation, enlarged sinuses and/or dilatation of the sinotubular junction, as in the case of ascending aortic dilatation, may result in disruption of the natural AoR function. Surgical treatment of AoR pathology has two modalities: the replacement of the aortic valve by artificial prosthesis or by preservation of the three leaflets and reconstruction of the aortic root components. Currently, there are two basic aortic root reconstruction procedures: aortic root sparing and aortic valve reimplantation techniques. Regardless of the technique used, the restoration of adequate cusp coaptation, is from a technical point of view, the most important element to consider. To achieve this, there are two requirements that need to be met: (i) the valve coaptation should be superior to the level of the aortic root base by at least 8 mm and (ii) the coaptation height per se has to be ≥5 mm. Successful restoration of the aortic root requires adequate technical skills, detailed knowledge of aortic root anatomy and topography, and also knowledge of the spatial pattern of AoR elements. Recently, there has been growing interest in aortic root reconstructive procedures as well their modifications. As such, the aim of this review is to analyse aortic root topography and 3D anatomy from a surgical point of view. The review also focuses on potential risk regions that one should be aware of before the surgical journey into the 'deep waters area' of the AoR begins.
Resumo:
La tomodensitométrie (TDM) est une technique d'imagerie pour laquelle l'intérêt n'a cessé de croitre depuis son apparition au début des années 70. De nos jours, l'utilisation de cette technique est devenue incontournable, grâce entre autres à sa capacité à produire des images diagnostiques de haute qualité. Toutefois, et en dépit d'un bénéfice indiscutable sur la prise en charge des patients, l'augmentation importante du nombre d'examens TDM pratiqués soulève des questions sur l'effet potentiellement dangereux des rayonnements ionisants sur la population. Parmi ces effets néfastes, l'induction de cancers liés à l'exposition aux rayonnements ionisants reste l'un des risques majeurs. Afin que le rapport bénéfice-risques reste favorable au patient il est donc nécessaire de s'assurer que la dose délivrée permette de formuler le bon diagnostic tout en évitant d'avoir recours à des images dont la qualité est inutilement élevée. Ce processus d'optimisation, qui est une préoccupation importante pour les patients adultes, doit même devenir une priorité lorsque l'on examine des enfants ou des adolescents, en particulier lors d'études de suivi requérant plusieurs examens tout au long de leur vie. Enfants et jeunes adultes sont en effet beaucoup plus sensibles aux radiations du fait de leur métabolisme plus rapide que celui des adultes. De plus, les probabilités des évènements auxquels ils s'exposent sont également plus grandes du fait de leur plus longue espérance de vie. L'introduction des algorithmes de reconstruction itératifs, conçus pour réduire l'exposition des patients, est certainement l'une des plus grandes avancées en TDM, mais elle s'accompagne de certaines difficultés en ce qui concerne l'évaluation de la qualité des images produites. Le but de ce travail est de mettre en place une stratégie pour investiguer le potentiel des algorithmes itératifs vis-à-vis de la réduction de dose sans pour autant compromettre la qualité du diagnostic. La difficulté de cette tâche réside principalement dans le fait de disposer d'une méthode visant à évaluer la qualité d'image de façon pertinente d'un point de vue clinique. La première étape a consisté à caractériser la qualité d'image lors d'examen musculo-squelettique. Ce travail a été réalisé en étroite collaboration avec des radiologues pour s'assurer un choix pertinent de critères de qualité d'image. Une attention particulière a été portée au bruit et à la résolution des images reconstruites à l'aide d'algorithmes itératifs. L'analyse de ces paramètres a permis aux radiologues d'adapter leurs protocoles grâce à une possible estimation de la perte de qualité d'image liée à la réduction de dose. Notre travail nous a également permis d'investiguer la diminution de la détectabilité à bas contraste associée à une diminution de la dose ; difficulté majeure lorsque l'on pratique un examen dans la région abdominale. Sachant que des alternatives à la façon standard de caractériser la qualité d'image (métriques de l'espace Fourier) devaient être utilisées, nous nous sommes appuyés sur l'utilisation de modèles d'observateurs mathématiques. Nos paramètres expérimentaux ont ensuite permis de déterminer le type de modèle à utiliser. Les modèles idéaux ont été utilisés pour caractériser la qualité d'image lorsque des paramètres purement physiques concernant la détectabilité du signal devaient être estimés alors que les modèles anthropomorphes ont été utilisés dans des contextes cliniques où les résultats devaient être comparés à ceux d'observateurs humain, tirant profit des propriétés de ce type de modèles. Cette étude a confirmé que l'utilisation de modèles d'observateurs permettait d'évaluer la qualité d'image en utilisant une approche basée sur la tâche à effectuer, permettant ainsi d'établir un lien entre les physiciens médicaux et les radiologues. Nous avons également montré que les reconstructions itératives ont le potentiel de réduire la dose sans altérer la qualité du diagnostic. Parmi les différentes reconstructions itératives, celles de type « model-based » sont celles qui offrent le plus grand potentiel d'optimisation, puisque les images produites grâce à cette modalité conduisent à un diagnostic exact même lors d'acquisitions à très basse dose. Ce travail a également permis de clarifier le rôle du physicien médical en TDM: Les métriques standards restent utiles pour évaluer la conformité d'un appareil aux requis légaux, mais l'utilisation de modèles d'observateurs est inévitable pour optimiser les protocoles d'imagerie. -- Computed tomography (CT) is an imaging technique in which interest has been quickly growing since it began to be used in the 1970s. Today, it has become an extensively used modality because of its ability to produce accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase in the number of CT examinations performed has raised concerns about the potential negative effects of ionising radiation on the population. Among those negative effects, one of the major risks remaining is the development of cancers associated with exposure to diagnostic X-ray procedures. In order to ensure that the benefits-risk ratio still remains in favour of the patient, it is necessary to make sure that the delivered dose leads to the proper diagnosis without producing unnecessarily high-quality images. This optimisation scheme is already an important concern for adult patients, but it must become an even greater priority when examinations are performed on children or young adults, in particular with follow-up studies which require several CT procedures over the patient's life. Indeed, children and young adults are more sensitive to radiation due to their faster metabolism. In addition, harmful consequences have a higher probability to occur because of a younger patient's longer life expectancy. The recent introduction of iterative reconstruction algorithms, which were designed to substantially reduce dose, is certainly a major achievement in CT evolution, but it has also created difficulties in the quality assessment of the images produced using those algorithms. The goal of the present work was to propose a strategy to investigate the potential of iterative reconstructions to reduce dose without compromising the ability to answer the diagnostic questions. The major difficulty entails disposing a clinically relevant way to estimate image quality. To ensure the choice of pertinent image quality criteria this work was continuously performed in close collaboration with radiologists. The work began by tackling the way to characterise image quality when dealing with musculo-skeletal examinations. We focused, in particular, on image noise and spatial resolution behaviours when iterative image reconstruction was used. The analyses of the physical parameters allowed radiologists to adapt their image acquisition and reconstruction protocols while knowing what loss of image quality to expect. This work also dealt with the loss of low-contrast detectability associated with dose reduction, something which is a major concern when dealing with patient dose reduction in abdominal investigations. Knowing that alternative ways had to be used to assess image quality rather than classical Fourier-space metrics, we focused on the use of mathematical model observers. Our experimental parameters determined the type of model to use. Ideal model observers were applied to characterise image quality when purely objective results about the signal detectability were researched, whereas anthropomorphic model observers were used in a more clinical context, when the results had to be compared with the eye of a radiologist thus taking advantage of their incorporation of human visual system elements. This work confirmed that the use of model observers makes it possible to assess image quality using a task-based approach, which, in turn, establishes a bridge between medical physicists and radiologists. It also demonstrated that statistical iterative reconstructions have the potential to reduce the delivered dose without impairing the quality of the diagnosis. Among the different types of iterative reconstructions, model-based ones offer the greatest potential, since images produced using this modality can still lead to an accurate diagnosis even when acquired at very low dose. This work has clarified the role of medical physicists when dealing with CT imaging. The use of the standard metrics used in the field of CT imaging remains quite important when dealing with the assessment of unit compliance to legal requirements, but the use of a model observer is the way to go when dealing with the optimisation of the imaging protocols.
Resumo:
Objective To develop procedures to ensure consistency of printing quality of digital images, by means of hardcopy quantitative analysis based on a standard image. Materials and Methods Characteristics of mammography DI-ML and general purpose DI-HL films were studied through the QC-Test utilizing different processing techniques in a FujiFilm®-DryPix4000 printer. A software was developed for sensitometric evaluation, generating a digital image including a gray scale and a bar pattern to evaluate contrast and spatial resolution. Results Mammography films showed maximum optical density of 4.11 and general purpose films, 3.22. The digital image was developed with a 33-step wedge scale and a high-contrast bar pattern (1 to 30 lp/cm) for spatial resolution evaluation. Conclusion Mammographic films presented higher values for maximum optical density and contrast resolution as compared with general purpose films. The utilized digital processing technique could only change the image pixels matrix values and did not affect the printing standard. The proposed digital image standard allows greater control of the relationship between pixels values and optical density obtained in the analysis of films quality and printing systems.
Resumo:
In this paper we discuss the use of digital data by the Swiss Federal Criminal Court in a recent case of attempted homicide. We use this case to examine drawbacks for the defense when the presentation of scientific evidence is partial, especially when the only perspective mentioned is that of the prosecution. We tackle this discussion at two distinct levels. First, we pursue an essentially non-technical presentation of the topic by drawing parallels between the court's summing up of the case and flawed patterns of reasoning commonly seen in other forensic disciplines, such as DNA and particle traces (e.g., gunshot residues). Then, we propose a formal analysis of the case, using elements of probability and graphical probability models, to justify our main claim that the partial presentation of digital evidence poses a risk to the administration of justice in that it keeps vital information from the defense. We will argue that such practice constitutes a violation of general principles of forensic interpretation as established by forensic science literature and current recommendations by forensic science interest groups (e.g., the European Network of Forensic Science Institutes). Finally, we posit that argument construction and analysis using formal methods can help replace digital evidence appropriately into context and thus support a sound evaluation of the evidence.
Resumo:
Objective The present study evaluated the reliability of digital panoramic radiography in the diagnosis of carotid artery calcifications. Materials and Methods Thirty-five patients under high-risk for development of carotid artery calcifications who had digital panoramic radiography were referred to undergo ultrasonography. Thus, 70 arteries were assessed by both methods. The main parameters utilized to evaluate the panoramic radiography reliability in the diagnosis of carotid artery calcifications were accuracy, sensitivity, specificity and positive predictive value of this method as compared with ultrasonography. Additionally, the McNemar's test was utilized to verify whether there was a statistically significant difference between digital panoramic radiography and ultrasonography. Results Ultrasonography demonstrated carotid artery calcifications in 17 (48.57%) patients. Such individuals presented with a total of 29 (41.43%) carotid arteries affected by calcification. Radiography was accurate in 71.43% (n = 50) of cases evaluated. The degree of sensitivity of this method was 37.93%, specificity of 95.12% and positive predictive value of 84.61%. A statistically significant difference (p < 0.001) was observed between the methods evaluated in their capacity to diagnose carotid artery calcifications. Conclusion Digital panoramic radiography should not be indicated as a method of choice in the investigation of carotid artery calcifications.
Resumo:
Peer-reviewed
Resumo:
This article argues that interactive documentaries play a key role in digital multicasting strategies the author offers analysis of the latest trends in this area from three angles: the documentery subject, the support/ platform, and the user experience.
Resumo:
Defining digital humanities might be an endless debate if we stick to the discussion about the boundaries of this concept as an academic "discipline". In an attempt to concretely identify this field and its actors, this paper shows that it is possible to analyse them through Twitter, a social media widely used by this "community of practice". Based on a network analysis of 2,500 users identified as members of this movement, the visualisation of the "who's following who?" graph allows us to highlight the structure of the network's relationships, and identify users whose position is particular. Specifically, we show that linguistic groups are key factors to explain clustering within a network whose characteristics look similar to a small world.
Resumo:
AbstractObjective:The present study is aimed at contributing to identify the most appropriate OSEM parameters to generate myocardial perfusion imaging reconstructions with the best diagnostic quality, correlating them with patients' body mass index.Materials and Methods:The present study included 28 adult patients submitted to myocardial perfusion imaging in a public hospital. The OSEM method was utilized in the images reconstruction with six different combinations of iterations and subsets numbers. The images were analyzed by nuclear cardiology specialists taking their diagnostic value into consideration and indicating the most appropriate images in terms of diagnostic quality.Results:An overall scoring analysis demonstrated that the combination of four iterations and four subsets has generated the most appropriate images in terms of diagnostic quality for all the classes of body mass index; however, the role played by the combination of six iterations and four subsets is highlighted in relation to the higher body mass index classes.Conclusion:The use of optimized parameters seems to play a relevant role in the generation of images with better diagnostic quality, ensuring the diagnosis and consequential appropriate and effective treatment for the patient.
Resumo:
Abstract Objective: Derive filtered tungsten X-ray spectra used in digital mammography systems by means of Monte Carlo simulations. Materials and Methods: Filtered spectra for rhodium filter were obtained for tube potentials between 26 and 32 kV. The half-value layer (HVL) of simulated filtered spectra were compared with those obtained experimentally with a solid state detector Unfors model 8202031-H Xi R/F & MAM Detector Platinum and 8201023-C Xi Base unit Platinum Plus w mAs in a Hologic Selenia Dimensions system using a direct radiography mode. Results: Calculated HVL values showed good agreement as compared with those obtained experimentally. The greatest relative difference between the Monte Carlo calculated HVL values and experimental HVL values was 4%. Conclusion: The results show that the filtered tungsten anode X-ray spectra and the EGSnrc Monte Carlo code can be used for mean glandular dose determination in mammography.
Resumo:
Quince años después de la aparición de los primeros diarios en Internet, los medios de comunicación en general y la prensa en particular se encuentran inmersos en una situación singularmente crítica, incierta y desconcertante. En estos momentos de cambios profundos se mezclan amenazas y oportunidades en un cóctel aún incierto del cual no se sabe muy bien qué surgirá.Las amenazas provienen de la crisis de la prensa escrita, acuciada por la pérdida de lectores y el descenso de la publicidad, por la aparición de nuevos agentes informativos y por las dudas sobre el papel mediador del periodista.La crisis económica, iniciada con virulencia en los últimos meses del 2008, provocó entre otros efectos una drástica reducción de las inversiones de las empresas e instituciones en publicidad en medios, hecho que ataca frontalmente el modelo de negocio de los diarios. Al agudo golpe acusado en la reducción de ingresos publicitarios, se superpone un cambio cultural de gran calado en los hábitos de consumo de noticias, que se va abriendo paso a medida que las nuevas (y no tan nuevas) generaciones de lectores dejan de comprar diarios en papel (o reducen su consumo) para leer las informaciones de actualidad directamente en Internet.Además, las informaciones de actualidad ahora ya no solamente las ofrecen las cabeceras en línea de los medios de comunicación convencionales, sino también una variada oferta de productos y servicios: agregadores, blogs, webs sociales, redes sociales, twitter, etcétera, con lo cual la hegemonía informativa de la que disfrutaban los medios de comunicación de masas en la época «analógica», se difumina en el entorno digital y a la vez también se debilita el papel del periodista como mediador entre la realidad y la audiencia. De esta forma se constata que los cambios no son tan solo económicos, sino que afectan también a la esencia de la función de la prensa y de los periodistas...
Resumo:
Many educators and educational institutions have yet to integrate web-based practices into their classrooms and curricula. As a result, it can be difficult to prototype and evaluate approaches to transforming classrooms from static endpoints to dynamic, content-creating nodes in the online information ecosystem. But many scholastic journalism programs have already embraced the capabilities of the Internet for virtual collaboration, dissemination, and reader participation. Because of this, scholastic journalism can act as a test-bed for integrating web-based sharing and collaboration practices into classrooms. Student Journalism 2.0 was a research project to integrate open copyright licenses into two scholastic journalism programs, to document outcomes, and to identify recommendations and remaining challenges for similar integrations. Video and audio recordings of two participating high school journalism programs informed the research. In describing the steps of our integration process, we note some important legal, technical, and social challenges. Legal worries such as uncertainty over copyright ownership could lead districts and administrators to disallow open licensing of student work. Publication platforms among journalism classrooms are far from standardized, making any integration of new technologies and practices difficult to achieve at scale. And teachers and students face challenges re-conceptualizing the role their class work can play online.
Resumo:
In this paper we describe a browsing and searching personalization system for digitallibraries based on the use of ontologies for describing the relationships between all theelements which take part in a digital library scenario of use. The main goal of thisproject is to help the users of a digital library to improve their experience of use bymeans of two complementary strategies: first, by maintaining a complete history recordof his or her browsing and searching activities, which is part of a navigational userprofile which includes preferences and all the aspects related to community involvement; and second, by reusing all the knowledge which has been extracted from previous usage from other users with similar profiles. This can be accomplished in terms of narrowing and focusing the search results and browsing options through the use of a recommendation system which organizes such results in the most appropriatemanner, using ontologies and concepts drawn from the semantic web field. The complete integration of the experience of use of a digital library in the learning process is also pursued. Both the usage and information organization can be also exploited to extract useful knowledge from the way users interact with a digital library, knowledge that can be used to improve several design aspects of the library, ranging from internal organization aspects to human factors and user interfaces. Although this project is still on an early development stage, it is possible to identify all the desired functionalities and requirements that are necessary to fully integrate the use of a digital library in an e-learning environment.
Resumo:
Peer-reviewed