991 resultados para Acidic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selective determination of morphine in the larvae of Calliphora stygia (Fabricius) (Diptera: Calliphoridae) using acidic potassium permanganate chemiluminescence detection coupled with flow injection analysis and high-performance liquid chromatography (HPLC) is described. Larvae of C. stygia were reared on minced meat substrates that had been spiked with varying concentrations of morphine. Morphine concentrations were chosen to reflect typical levels in human tissues from opiate overdose victims. After maturing on substrates, larvae were analyzed for the presence of morphine using chemiluminescence detection coupled to flow injection analysis and a rapid HPLC method. Analysis of the larval matrix by flow injection analysis with chemiluminescence detection indicated the presence of interferants capable of generating chemiluminescence. A rapid chromatographic separation with a monolithic column allowed selective determination of morphine in larvae using postcolumn chemiluminescence detection. Larvae of C. stygia reared on substrates containing morphine at concentrations of 500 and 1000 ng/g did not sequester morphine at detectable concentrations. Larvae reared on substrates containing morphine concentrations of 2500, 5000, and 10,000 ng/g tested positive for the drug at concentrations of 765, 2720, and 3010 ng/g, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids – morphine, codeine, oripavine and thebaine – were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1 × 10−10 M, 5 × 10−10 M, 5 × 10−10 M and 1 × 10−9 M, for morphine, codeine, oripavine and thebaine, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the results of our investigations into the use of soluble manganese(IV) as a chemiluminescence reagent, which include a significantly faster method of preparation and a study on the effect of formaldehyde and orthophosphoric acid concentration on signal intensity. Chemiluminescence detection was applied to the determination of 16 analytes, including opiate alkaloids, indoles and analytes of forensic interest, using flow injection analysis methodology. The soluble manganese(IV) reagent was less selective than either acidic potassium permanganate or tris(2,2′-bipyridyl)ruthenium(III) and therefore provided a more universal chemiluminescence detection system for HPLC. A broad spectral distribution with a maximum at 730 ± 5 nm was observed for the reaction between the soluble manganese(IV) and a range of analytes, as well as the background emission from the reaction with the formaldehyde enhancer. This spectral distribution matches that reported for chemiluminescence reactions with acidic potassium permanganate, where a manganese(II) emitting species was elucidated. This provides further evidence that the emission evoked in reactions with soluble manganese(IV) also emanates from a manganese(II) species, and not bimolecular singlet oxygen as suggested by previous authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2′-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mesostructurally ordered inorganic–organic hybrid composite materials were successfully synthesized by utilizing a low-molecular-weight amphiphilic polyethylene-block-poly(ethylene oxide) (PE–PEO) diblock copolymer as the directing agent. The hybrid composites were formed via the sol–gel reaction of inorganic precursor tetraethoxysilane (TEOS) in an acidic ethanol/water solution with various amounts of PE–PEO. In these composite materials, the hydrophobic PE block of the PE–PEO copolymer forms separate microphase on the nanoscales within the rigid matrix of silica network. The crystallization of the PE block is strictly restricted within the microphase by the rigid silica matrix and takes place through homogeneous nucleation under the nanoscale confinement environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A pulse of chromated copper arsenate (CCA, a timber preservative) was applied in irrigation water to an undisturbed field soil in a laboratory column. Concentrations of various elements in the leachate from the column were measured during the experiment. Also, the remnants within the soil were measured at the end of the experiment. The geochemical modelling package, PHREEQC-2, was used to simulate the experimental data. Processes included in the CCA transport modelling were advection, dispersion, non-specific adsorption (cation exchange) and specific adsorption by clay minerals and organic matter, as well as other possible chemical reactions such as precipitation/dissolution. The modelling effort highlighted the possible complexities in CCA transport and reaction experiments. For example, the uneven dosing of CCA as well as incomplete knowledge of the soil properties resulted in simulations that gave only partial, although reasonable, agreement with the experimental data. Both the experimental data and simulations show that As and Cu are strongly adsorbed and therefore, will mostly remain at the top of the soil profile, with a small proportion appearing in leachate. On the other hand, Cr is more mobile and thus it is present in the soil column leachate. Further simulations show that both the quantity of CCA added to the soil and the pH of the irrigation water will influence CCA transport. Simulations suggest that application of larger doses of CCA to the soil will result in higher leachate concentrations, especially for Cu and As. Irrigation water with a lower pH will dramatically increase leaching of Cu. These results indicate that acidic rainfall or significant accidental spillage of CCA will increase the risk of groundwater pollution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel chemiluminescence flow injection procedure for the determination of As(III) in aqueous samples is described. The method involves injection of As(III) samples into a 1% (m/v) sodium hexametaphosphate in 0.02 M H2SO4 carrier stream, which then merges at a Y-piece with a reagent stream consisting of potassium permanganate (5.0 × 10−5 M) made up in the acidic sodium hexametaphosphate carrier solution. The chemiluminescence intensity of the resulting reaction mixture was measured at a photomultiplier tube operated at a voltage of 0.93 kV. Under optimized conditions, the method is characterised by a linear range from 0.5 to 5.0 μg l−1, a detection limit of 0.3 μg l−1 and a sampling frequency of 150 h−1. The effects of common anionic and cationic interferences were investigated, and it was found that the only ions to cause serious interference were those which react with potassium permanganate, namely sulphide, iodide and ferrous.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review article focuses primarily on the work carried in our laboratories over the last few years using luminescent and colorimetric sensors, where the anion recognition occurs through hydrogen bonding in organic or aqueous solvents. This review begins with the story of the discovery of fluorescent photoinduced electron transfer (PET) sensors for anions using charged neutral urea or thiourea receptors where both fluorescent and NMR spectroscopic methods monitored anion recognition. This work led to the development of dual luminescent and colorimetric anion sensors based on the use of the ICT based naphthalimide chromophore, where ions such as fluoride gave rise to changes in both the fluorescence and the absorption spectra of the sensors, but at different concentrations. Here, the former changes were due to hydrogen bonding interactions, whereas the latter was due to the deprotonation of acidic protons, giving rise to the formation of the bifluoride anion (HF2−). Modification of the 4-amino-l,8-naphthalimide moiety has facilitated the formation of colorimetric anion sensors that work both in organic or aqueous solutions. Such charge neutral receptor motifs have also been incorporated into organic scaffolds with norbomyl and calixarene backbones, which have enabled us to produce anion directed self-assembled structures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Article Outline
• Introduction
Acidic Potassium Permanganate
• Acridinium Esters
• Diaryl Oxalates and Oxamides
• Dioxetanes
• Hypohalites
• Luminol and Its Analogs
• Tris(2,2′-bipyridyl)ruthenium(II)
• Practical Considerations
• HPLC and Flow Analysis
• Capillary Electrophoresis
• Enzyme Reaction Products
• Immunoassay and DNA Assays
• Further Reading


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examines the resistance change in conductive polypyrrole-coated PET fabrics under the AS 2001.4.15 – 1994 laundering test conditions. The effects of individual detergent components of a standard detergent, including auxiliary chemicals, at four different temperatures were studied. When the coated fabric was washed under the AS 2001.4.15-1994 conditions, the ECE reference detergent and pure soap flakes (sodium sterate) both decreased the conductivity of the coating at a rate exponentially proportional to the laundering temperature. Detergent types had an influence over the rate of degradation; pH conditions had a large influence on the rate of polymer deterioration with the acidic nonionic detergent giving rise to significantly improved laundering conditions. The auxiliary chemicals, sodium carbonate and sodium perborate were seen to cause large degradation of polymers during laundering. Ethylene diamine tetra acetic acid was seen to have only a slight influence on the reduction of conductivity of polymers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sequential injection analysis procedure with dual-reagent chemiluminescence detection was applied to the screening of street drug seizure samples for the presence of heroin. The chemiluminescence reagents (acidic potassium permanganate and tris(2,2′-bipyridine)ruthenium(III)) were aspirated from either side of a sample aliquot that was sufficiently large to prevent interdispersion of the reagent zones, and therefore two different chemical reactions could be performed simultaneously at either end of the sample zone. The presence of heroin in seizure samples was indicated by a strong response with the tris(2,2′-bipyridine)ruthenium(III) reagent and confirmed by a significant increase in the response with the permanganate reagent when the sample was treated with sodium hydroxide to hydrolyse the heroin to morphine. Nicomorphine (a morphine-derived pharmaceutical) was synthesised and tested under the same conditions. The responses with the permanganate reagent were similar to those for heroin, which supports the proposed chemical basis for the test. However, the responses with tris(2,2′-bipyridine)ruthenium(III) were far lower for nicomorphine than heroin (approximately 5-fold for the samples that had not been hydrolysed).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A review with 98 references. The determination of the opium poppy (Papaver somniferum) alkaloids and their semi-synthetic derivatives has important applications in industrial process monitoring, clinical analysis and forensic science. Liquid-phase chemiluminescence reagents such as tris(2,2′-bipyridyl)ruthenium(II) and acidic potassium permanganate exhibit remarkable sensitivity and complementary selectivity for many P. somniferum alkaloids, which has been exploited in the development of a range of analytical procedures using flow analysis, high-performance liquid chromatography, capillary electrophoresis and microfluidic instrumentation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new chemiluminescence detector, with solution channels that have been machined into a Teflon disk and sealed with a sapphire window. The configuration of the flow cell can be conveniently modified by replacing the Teflon disk. A comparison of some existing and novel designs, using the chemiluminescence reaction of morphine with acidic potassium permanganate and the bioluminescence reaction of ATP with the commercially available “BacTiter-Glo” reagent, has revealed that a serpentine channel allows greater quantities of light to be captured than a spiral channel, due to more efficient mixing of the analyte and reagent solutions within the cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, gold nanoparticles were synthesized by electroless recovery of [AuCl4]− from an acidic aqueous solution using nano-structured conducting polymer, polypyrrole nanoparticles, as active surface. The formation of gold nanoparticles was confirmed by TEM, SEM and EDX measurements. The effects of the initial Au(III) concentration on the gold uptake was examined. The recovery capability and gold particle morphology prepared from polypyrrole nanoparticle were compared to that from cast PPy film counterpart.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies have suggested that tris(4,7-diphenyl-1,10-phenanthrolinedisulfonate)ruthenium(II) (Ru(BPS)34−) has great potential as a chemiluminescence reagent in acidic aqueous solution. We have evaluated four different samples of this reagent (two commercially available and two synthesised in our laboratory) in comparison with tris(2,2′-bipyridine)ruthenium(II) (Ru(bipy)32+) and tris(1,10-phenanthroline)ruthenium(II) (Ru(phen)32+), using a range of structurally diverse analytes. In general, Ru(BPS)34− produced more intense chemiluminescence, but the oxidised Ru(BPS)33− species is less stable in aqueous solution than Ru(bipy)33+ and produced a greater blank signal than Ru(bipy)33+ or Ru(phen)33+, which had a detrimental effect on sensitivity. Although the complex is often depicted with the sulfonate groups of the BPS ligand in the para position on the phenyl rings, NMR characterisation revealed that the commercially available BPS material used in this study was predominantly the meta isomer.