989 resultados para Studies of language


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our recent studies on kinetic behaviors of gas flows are reviewed in this paper. These flows have a wide range of background, but share a common feature that the flow Knudsen number is larger than 0.01. Thus kinetic approaches such as the direct simulation Monte Carlo method are required for their description. In the past few years, we studied several micro/nano-scale flows by developing novel particle simulation approach, and investigated the flows in low-pressure chambers and at high altitude. In addition, the microscopic behaviors of a couple of classical flow problems were analyzed, which shows the potential for kinetic approaches to reveal the microscopic mechanism of gas flows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To achieve a better time resolution of a scintillator-bar detector for a neutron wall at the external target facility of HIRFL-CSR,we have carried out a detailed study of the photomultiplier,the wrapping material and the coupling media. The timing properties of a scintillator-bar detector have been studied in detail with cosmic rays using a high and low level signal coincidence. A time resolution of 80 ps has been achieved in the center of the scintillator-bar detector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Timing and amplitude properties of a prototype scintillator TOF counter at an external target facility are studied with a cosmic rays test. The dependence of signal pulse height and time resolution on the coordinate along the scintillator TOF counter is investigated with two different discriminators. A time resolution of 165 ps can be achieved at the center of the counter with a constant fraction discriminator. Time resolution better than 150 ps is obtained at the center with a leading edge discriminator af...

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper a two dimensional readout micromegas detector with a polyethylene foil as converter was simulated on GEANT4 toolkit and GARFIELD for fast neutron detection. A new track reconstruction method based on time coincidence technology was developed in the simulation to obtain the incident neutron position. The results showed that with this reconstruction method higher spatial resolution was achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

为了研究低速高电荷态离子在C60薄膜中引起的势效应,用能量为200keV的高电荷态Xen+(n=3,10,13,15,17,20,22,23)离子辐照了C60薄膜。用原子力显微镜(AFM)和Raman散射技术分析了辐照过程中高电荷态Xen+离子所储存势能在C60薄膜中引起的效应,即势效应。AFM分析结果表明,辐照C60薄膜的表面粗糙度随辐照Xen+离子电荷态(即势能)的增加而减小,揭示了势效应的存在。而Raman分析结果表明,由于Xe离子的动能远大于其所储存的势能,因此,尽管有表面势效应的影响,但在Raman分析的深度范围内,弹性碰撞还是主导了C60薄膜的损伤过程。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims. We determine branching fractions, cross sections and thermal rate constants for the dissociative recombination of CD3CDOD+ and CH3CH2OH2+ at the low relative kinetic energies encountered in the interstellar medium. Methods. The experiments were carried out by merging an ion and electron beam at the heavy ion storage ring CRYRING, Stockholm, Sweden. Results. Break-up of the CCO structure into three heavy fragments is not found for either of the ions. Instead the CCO structure is retained in 23 +/- 3% of the DR reactions of CD3CDOD+ and 7 +/- 3% in the DR of CH3CH2OH2+, whereas rupture into two heavy fragments occurs in 77 +/- 3% and 93 +/- 3% of the DR events of the respective ions. The measured cross sections were fitted between 1-200 meV yielding the following thermal rate constants and cross-section dependencies on the relative kinetic energy: sigma(E-cm[eV]) = 1.7 +/- 0.3 x 10(-15)(Ecm[eV])(-1.23 +/- 0.02) cm(2) and k(T) = 1.9 +/- 0.4 x 10(-6)(T/300)-0.73 +/- 0.02 cm(3) s(-1) for CH3CH2OH2+ as well as k(T) = 1.1 +/- 0.4 x 10(-6)(T/300)(-0.74 +/- 0.05) cm(3) s(-1) and s(Ecm[eV]) = 9.2 +/- 4 x 10(-16)(Ecm[eV])-1.24 +/- 0.05 cm(2) for CD3CDOD+

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports that the K x-ray spectra of the thin target 47Ag, 48Cd, 49In and 50Sn were measured by an HPGe semi-conductor detector in collisions with 84.5 MeV 6C4+ ions. Our experiment revealed the Kα x-ray energy shifts were not obvious and the Kβ1 x-ray energy shifts were about 90∼110 eV. The simple model of Burch et al has been previously used to calculate the K x-ray energy shifts due to an additional vacancy in 2p orbit. The present work extends the model of Burch to calculate the x-ray energy shifts of multiple ionized atoms induced by heavy ions with kinetic energy of MeV/u. In addition to our experimental results, many other experimental results are compared with the calculated values by using the model.