959 resultados para Microwave Mammography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A microwave (MW)-assisted crosslinking process to prepare hydrogel-forming microneedle (MN) arrays was evaluated. The effects of the crosslinking process on the MN arrays characteristics was evaluated. The results suggest that MN arrays prepared using the MW assisted process had equivalent properties to those prepared conventionally, but can be produced 30 times faster.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper details the results from a large European Union rotomoulding research project on the adaptation and development of industrial microwave oven technology to the rotational moulding process. Following computer modelling, an industrial scale microwave oven was specifically designed, manufactured and attached to the drop-arm of a convention rotational moulding machine where extensive moulding trials were carried out. The design and development of the microwave oven and test mould, together with the savings in terms of energy efficiency and mould heating rate that were achieved are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave synthesis is shown to be a valuable route to novel fluorinated ionic liquid surfactants. 1-Methyl-3-(3,3,4,4,5,5,6,6,6-nonafluorohexyl)imidazolium iodide was prepared by treatment of 1-methylimidazole with 1-iodo-1H,1H,2H,2H-perfluorohexane in a microwave reactor, and this product underwent anion exchange to yield 1-methyl-3-(3,3,4,4,5,5,6,6,6-nonafluorohexyl)imidazolium nonafluoro-1-butanesulfonate. This catanionic surfactant showed intriguing phase behavior and low surface tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The semiconductor industry's urge towards faster, smaller and cheaper integrated circuits has lead the industry to smaller node devices. The integrated circuits that are now under volume production belong to 22 nm and 14 nm technology nodes. In 2007 the 45 nm technology came with the revolutionary high- /metal gate structure. 22 nm technology utilizes fully depleted tri-gate transistor structure. The 14 nm technology is a continuation of the 22 nm technology. Intel is using second generation tri-gate technology in 14 nm devices. After 14 nm, the semiconductor industry is expected to continue the scaling with 10 nm devices followed by 7 nm. Recently, IBM has announced successful production of 7 nm node test chips. This is the fashion how nanoelectronics industry is proceeding with its scaling trend. For the present node of technologies selective deposition and selective removal of the materials are required. Atomic layer deposition and the atomic layer etching are the respective techniques used for selective deposition and selective removal. Atomic layer deposition still remains as a futuristic manufacturing approach that deposits materials and lms in exact places. In addition to the nano/microelectronics industry, ALD is also widening its application areas and acceptance. The usage of ALD equipments in industry exhibits a diversi cation trend. With this trend, large area, batch processing, particle ALD and plasma enhanced like ALD equipments are becoming prominent in industrial applications. In this work, the development of an atomic layer deposition tool with microwave plasma capability is described, which is a ordable even for lightly funded research labs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The highly efficient eco-friendly synthesis of ketones (yields over 99%) from secondary alcohols is achieved by combination of [FeCl2{eta(3)-HC(pz)(3)}] (pz = pyrazol-1-yl) supported on functionalized multi-walled carbon nanotubes and microwave irradiation, in a solvent-free medium. The carbon homoscorpionate iron(II) complex is the first one of this class to be used as catalyst for the oxidation of alcohols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Image blurring in Full Field Digital Mammography (FFDM) is reported to be a problem within many UK breast screening units resulting in significant proportion of technical repeats/recalls. Our study investigates monitors of differing pixel resolution, and whether there is a difference in blurring detection between a 2.3 MP technical review monitor and a 5MP standard reporting monitor. Methods - Simulation software was created to induce different magnitudes of blur on 20 artifact free FFDM screening images. 120 blurred and non-blurred images were randomized and displayed on the 2.3 and 5MP monitors; they were reviewed by 28 trained observers. Monitors were calibrated to the DICOM Grayscale Standard Display Function. T-test was used to determine whether significant differences exist in blurring detection between the monitors. Results - The blurring detection rate on the 2.3MP monitor for 0.2, 0.4, 0.6, 0.8 and 1 mm blur was 46, 59, 66, 77and 78% respectively; and on the 5MP monitor 44, 70, 83 , 96 and 98%. All the non-motion images were identified correctly. A statistical difference (p <0.01) in the blurring detection rate between the two monitors was demonstrated. Conclusions - Given the results of this study and knowing that monitors as low as 1 MP are used in clinical practice, we speculate that technical recall/repeat rates because of blurring could be reduced if higher resolution monitors are used for technical review at the time of imaging. Further work is needed to determine monitor minimum specification for visual blurring detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mammography is one of the most technically demanding examinations in radiology, and it requires X-ray technology designed specifi cally for the task. The pathology to be imaged ranges from small (20–100 μm) high density microcalcifications to ill-defi ned low contrast masses. These must be imaged against a background of mixed densities. This makes demonstrating pathology challenging. Because of its use in asymptomatic screening, mammography must also employ as low a radiation dose as possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To estimate the prevalence and factors associated with the performance of mammography and pap smear test in women from the city of Maringá, Paraná. Methods: Population-based cross-sectional study conducted with 345 women aged over 20 years in the period from March 2011 to April 2012. An interview was carried out using a questionnaire proposed by the Ministry of Health, which addressed sociodemographic characteristics, risk factors for chronic noncommunicable diseases and issues related to mammographic and pap screening. Data were analyzed using bivariate analysis, crude analysis with odds ratio (OR) and chi-squared test using Epi Info 3.5.1 program; multivariate analysis using logistic regression was performed using the software Statistica 7.1, with a significance level of 5% and a confidence interval of 95%. Results: The mean age of the women was 52.19 (±5.27) years. The majority (56.5%) had from 0 to 8 years of education. Additionally, 84.6% (n=266) of the women underwent pap smear and 74.3% (n=169) underwent mammography. The lower performance of pap smear test was associated with women with 9-11 years of education (p=0.01), and the lower performance of mammography was associated with women without private health insurance (p<0.01). Conclusion: The coverage of mammography and pap smear test was satisfactory among the women from Maringá, Paraná. Low education level and women who depended on the public health system presented lower performance of mammography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The TOPEX/POSEIDON mission offers the first opportunity to observe rain cells over the ocean by a dual-frequency radar altimeter (TOPEX) and simultaneously observe their natural radiative properties by a three-frequency radiometer (TOPEX microwave radiometer (TMR)). This work is a feasibility study aimed at understanding the capability and potential of the active/passive TOPEX/TMR system for oceanic rainfall detection. On the basis of past experiences in rain flagging, a joint TOPEX/TMR rain probability index is proposed. This index integrates several advantages of the two sensors and provides a more reliable rain estimate than the radiometer alone. One year's TOPEX/TMR TMR data are used to test the performance of the index. The resulting rain frequency statistics show quantitative agreement with those obtained from the Comprehensive Ocean-Atmosphere Data Set (COADS) in the Intertropical Convergence Zone (ITCZ), while qualitative agreement is found for other regions of the world ocean. A recent finding that the latitudinal frequency of precipitation over the Southern Ocean increases steadily toward the Antarctic continent is confirmed by our result. Annual and seasonal precipitation maps are derived from the index. Notable features revealed include an overall similarity in rainfall pattern from the Pacific, the Atlantic, and the Indian Oceans and a general phase reversal between the two hemispheres, as well as a number of regional anomalies in terms of rain intensity. Comparisons with simultaneous Global Precipitation Climatology Project (GPCP) multisatellite precipitation rate and COADS rain climatology suggest that systematic differences also exist. One example is that the maximum rainfall in the ITCZ of the Indian Ocean appears to be more intensive and concentrated in our result compared to that of the GPCP. Another example is that the annual precipitation produced by TOPEX/TMR is constantly higher than those from GPCP and COADS in the extratropical regions of the northern hemisphere, especially in the northwest Pacific Ocean. Analyses of the seasonal variations of prominent rainy and dry zones in the tropics and subtropics show various behaviors such as systematic migration, expansion and contraction, merging and breakup, and pure intensity variations, The seasonality of regional features is largely influenced by local atmospheric events such as monsoon, storm, or snow activities. The results of this study suggest that TOPEX and its follow-on may serve as a complementary sensor to the special sensor microwave/imager in observing global oceanic precipitation.