992 resultados para amplified fragment length polymorphisms (AFLP)
Resumo:
The development of HTLV-1 associated clinical manifestations, such as TSP/HAM and ATLL, occur in 2-4% of the infected population and it is still unclear why this infection remains asymptomatic in most infected carriers. Recently, it has been demonstrated that HTLV uses the Glucose transporter type 1 (GLUT1) to infect T-CD4(+) lymphocytes and that single nucleotide polymorphisms (SNP) in the GLUT1 gene are associated with diabetic nephropathy in patients with diabetes mellitus in different populations. These polymorphisms could contribute to a higher GLUT1 protein expression on cellular membrane, facilitating the entry of HTLV and its transmission cell by cell. This could result in a higher provirus load and consequently in the development of TSP/HAM. To evaluate the role of GLUT1 gene polymorphisms in the development of TSP/HAM in HTLV-1 infected individuals, the g.22999G > T, g.15339T > C and c.-2841A > T sites were analyzed by PCR/RFLP or sequencing in 244 infected individuals and 102 normal controls. The proviral load of the HTLV-1 infected patients was also analyzed using Real Time Quantitative PCR. Genotypic and allelic frequencies of the three sites did not differ significantly between controls and HTLV-1 infected individuals. There was no difference in genotypic and allelic distributions among patients as to the presence or absence of HTLV-1 associated clinic manifestations. As regards the quantification of the provirus load, we observed a significant reduction in the asymptomatic individuals compared with the oligosymptomatic and TSP/HAM individuals. These results suggest that g.22999G > T, g.15339T > C, and c.-2841A > T SNP do not contribute to HTLV-1 infection nor to the genetic susceptibility of TSP/HAM in Brazilian HTLV-1 infected individuals. J. Med. Virol. 81:552557, 2009. (C) 2009 Wiley-Liss, Inc.
Resumo:
Background: Angiogenesis has been shown as an important process in hematological malignancies. It consists in endothelial proliferation, migration, and tube formation following pro-angiogenic factors releasing, specially the vascular endothelial growth factor (VEGF), which angiogenic effect seems to be dependent on nitric oxide (NO). We examined the association among functional polymorphism in these two angiogenesis related genes: VEGF (-2578C>A, -1154G>A, and -634G>C) and NOS3 (-786T>C, intron 4 b>a, and Glu298Asp) with prognosis of childhood acute lymphoblastic leukemia (ALL). Methods: The genotypes were determined and haplotypes estimated in 105 ALL patients that were divided in 2 groups: high risk (HR) and low risk of relapse (LR) patients. In addition, event-free survival curves according to genotypes were assessed. Results: The group HR compared to the LR showed a higher frequency of the alleles -2578C and -634C and the haplotype CGC for VEGF (0.72 vs. 0.51, p<0.008; 0.47 vs. 0.26, p<0.008; and 42.1 vs. 14.5, p<0.006; respectively) and a lower frequency of the haplotype CbGlu (0.4 vs. 8.8, p<0.006), for NOS3. Conclusion: Polymorphisms of VEGF and NOS3 genes are associated with high risk of relapse, therefore may have a prognostic impact in childhood ALL. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
The interindividual variation in the activity of xenobiotic metabolizing enzymes and DNA repair genes could modify an individual`s risk of recurrent malignancy and response to therapy. We investigated whether ALL outcome was related to polymorphisms in genes CYP2D6. MPO, EPHX1, NQO1, TS, XPD and XRCC1 in 95 consecutive ALL children by PCR or PCR-FRLP techniques. Polymorphisms in genes NQO1 and TS were associated with a significantly slow response to induction chemotherapy and NQO1 was also associated with a lower five-year event-free survival. This study suggests that polymorphisms of NQO1 and TS could be important for patient response to induction therapy and for treatment outcome. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The HLA-G gene is predominantly expressed at the maternal-fetal interface. It has been associated with maternal-fetal tolerance and in the inhibition of cytotoxic T lymphocyte and natural killer cytolytic functions. At least two variations in the 3` untranslated region (UTR) of HLA-G locus are associated with HLA-G expression levels, the 14-bp deletion/insertion polymorphism and the +3142 single-nucleotide polymorphism (SNP). However, this region has not been completely characterized yet. The variability of the 3`UTR of HLA-G gene and its haplotype structure were characterized in 155 individuals from Brazil, as well as HLA-G alleles associated with each of the 3`UTR haplotype. The following eight variation sites were detected: the 14-bp polymorphism and SNPs at the positions +3003T/C, +3010C/G, +3027A/C, +3035C/T, +3142G/C, +3187A/G and +3196C/G. Similarly, 11 different 3`UTR haplotypes were identified and several HLA-G alleles presented only one 3`UTR haplotype. In addition, a high linkage disequilibrium among the variation sites was detected, especially among the 14-bp insertion and the alleles +3142G and +3187A, all previously associated with low mRNA availability, demonstrating that their effects are not independent. The detailed analyses of 3`UTR of the HLA-G locus may shed some light into mechanisms underlying the regulation of HLA-G expression. Genes and Immunity (2010) 11, 134-141; doi: 10.1038/gene.2009.74; published online 1 October 2009
Resumo:
Background: The tumor necrosis factor (TNF) gene is located within the highly polymorphic major histocompatibility complex region, exhibiting the -308 CA promoter region polymorphism and six microsatellites (TNFa-f) spanning the region nearby the TNF locus. Objective: In the present Study, we evaluated the frequency of -308 CA and TNFa-e polymorphisms and respective haplotypes (in chromosomal sequence: TNFd-TNFe-308GA-TNFc-TNFa-TNFb), in 222 patients with AIDS, 52 of whom exhibited cytomegalovirus retinitis, and in 202 healthy HIV-negative individuals. Method: TNF microsatellite and single nucleotide polymorphism typings were performed by PCR followed by polyacrylamide gel electrophoresis. Results: The TNF-308A allele and the 4-3-C-2-7-1 haplotype were associated with susceptibility to AIDS, whereas the TNFb4 allele and the 3-3-C-1-11-4 haplotype were associated with protection against AIDS development. The TNFc2 allele and the 4-1-G-2-2-1 haplotype, which contains the TNFc2 allele, were associated with cytomegalovirus retinitis. Conclusion: This study highlights that polymorphic sites spanning the region nearby the TNF locus are associated with AIDS per se and with cytomegalovirus retinitis in AIDS patients. (C) 2009 Wolters Kluwer Health | Lippincott Williams & Wilkins
Resumo:
Systemic lupus erythematosus (SLE) is an autoimmune disorder of the connective tissue with a wide and heterogeneous spectrum of manifestations, with renal and neurological involvement usually related to worse prognosis. SLE more frequently affects females of reproductive age, and a high prevalence and renal manifestation seem to be associated with non-European ethnicity. The present study aims to investigate candidate loci to SLE predisposition and evaluate the influence of ethnic ancestry in the disease risk and clinical phenotypic heterogeneity of lupus at onset. Samples represented by 111 patients and 345 controls, originated from the city of Belem, located in the Northern Region of Brazil, were investigated for polymorphisms in HLA-G, HLA-C, SLC11A1, MTHFR, CASP8 and 15 KIR genes, in addition to 89 Amerindian samples genotyped for SLC11A1. We also investigated 48 insertion/deletion ancestry markers to characterize individual African, European and Amerindian ancestry proportions in the samples. Predisposition to SLE was associated with GTGT deletion at the SLC11A1 3`UTR, presence of KIR2DS2 +/KIR2DS5 +/KIR3DS1 + profile, increased number of stimulatory KIR genes, and European and Amerindian ancestries. The ancestry analysis ruled out ethnic differences between controls and patients as the source of the observed associations. Moreover, the African ancestry was associated with renal manifestations. Lupus (2011) 20, 265-273.
Resumo:
Feline immunodeficiency virus (FIV) causes a slow progressive degeneration of the immune system which eventually leads to a disease comparable to acquired immune deficiency syndrome (AIDS) in humans. FIV has extensive sequence variation, a typical feature of lentiviruses. Sequence analysis showed that diversity was not evenly distributed throughout the genome, but was greatest in the envelope gene, env. The virus enters host cells via a sequential interaction, initiated by the envelope glycoprotein (env) binding the primary receptor molecule CD134 and followed by a subsequent interaction with chemokine co-receptor CXCR4. The purpose of this study was to isolate and characterize isolates of FIV from an open shelter in Sao Paulo, Brazil. The separated PBMC from 11 positive cats were co-cultured with MYA-1 cells. Full-length viral env glycoprotein genes were amplified and determined. Chimeric feline x human CD134 receptors were used to investigate the receptor utilization of 17 clones from Brazilian isolates of Fly. Analyses of the sequence present of molecular clones showed that all clones grouped within subtype B. In contrast to the virulent primary isolate FIV-GL8, expression of the first cysteine-rich domain (CRD1) of feline CD134 in the context of human CD134 was sufficient for optimal receptor function for all Brazilian FIV isolates tested. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Although antibodies to Bartonella henselae have been described in all neotropical felid species, DNA has been detected in only one species, Leopard us wiedii. The aim of this study was to determine whether DNA of Bartonella spp. could be detected in blood of other captive neotropical felids and evaluate risk factors and hematological findings associated with infection. Blood samples were collected from 57 small felids, including 1 Leopard us geoffroyi, 17 L wiedii, 22 Leopardus tigrinus, 14 Leopardus pardalis, and 3 Puma yagouaroundi; 10 blood samples from Panthera onca were retrieved from blood banks. Complete blood counts were performed on blood samples from small felids, while all samples were evaluated by PCR. DNA extraction was confirmed by amplification of the cat GAPDH gene. Bartonella spp. were assessed by amplifying a fragment of their 16S-23S rRNA intergenic spacer region; PCR products were purified and sequenced. For the small neotropical felids, risk factors [origin (wild-caught or zoo-born), gender, felid species, and flea exposure) were evaluated using exact multiple logistic regression. Hematological findings (anemia, polycythemia/hyperproteinemia, leukocytosis and leukopenia) were tested for association with infection using Fisher`s exact test. The 635 bp product amplified from 10 samples (10/67 = 14.92%) was identified as B. henselae by sequencing. Small neotropical felid males were more likely to be positive than females (95% CI = 0.00-0.451, p = 0.0028), however other analyzed variables were not considered risk factors (p > 0.05). Hematological abnormalities were not associated with infection (p > 0.05). This is the first report documenting B. henselae detection by PCR in several species of neotropical felids. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Objectives. The objectives of this study were to assess the accuracy of working length determination using 3 electronic apex locators and direct digital radiography and to compare the results with those obtained using the visual method (control measurement). Study design. Twenty extracted human maxillary premolars were selected: 17 two-rooted and 3 single-rooted (total of 37 canals). Working length was measured using electronic apex locators Elements Diagnostic, Root ZX, and Just II. Subsequently, teeth were positioned in the alveolar bone of a dry skull and submitted to direct digital radiography. A variation of +/- 1 mm was considered as acceptable. Results were analyzed using the Wilcoxon and the chi(2) tests. Results. Results presented an accuracy of 94.6% for Elements Diagnostic, 91.9% for Root ZX, 73.0% for Just II, and 64.9% for direct digital radiography when considering the margin of +/- 1 mm in relation to the control measurement. Comparisons with the actual control measurements resulted in accuracy results of 13.51%, 13.51%, 10.10%, and 2.70%, respectively. Conclusions. Root ZX and Elements Diagnostic are more accurate in determining working length when compared with Just II and Schick direct digital radiography. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111:e44-e49)
Resumo:
The immunossuppression caused by HIV infection makes the affected individuals more susceptible to some diseases including infections, neoplasms, or even the association between them. Kaposi sarcoma (KS) is the most common AIDS-related neoplasm, featured as an angioproliferative disorder. Its cause seems to be related to the human herpesvirus type 8 and it is usually associated with lower CD4+ T cell count. Oral involvement is frequent, presenting red to blue-purplish plaques, maculaes, and nodules. On the other hand, paracoccidioidomycosis (PCM) is a systemic mycosis, endemic in Latin America, caused by Paracoccidioides brasiliensis. This mycosis is not commonly related to human immunodeficiency virus (HIV) infection, although PCM can be present in immunosuppression cases. Oral lesions, as granulomatous ulcers, are often identified in seropositive patients with PCM. A rare case, in which a male HIV-positive patient presented simultaneously Kaposi sarcoma and PCM in the same fragment of oral mucosa biopsy, is described. To the best of our knowledge, this concomitant association had not been previously described. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Objective. The aim of this study was to evaluate the precision of working length determination of 3 electronic apex locators (EALs): Root ZX, RomiApex D-30, and Ipex at 0.0 mm, at the apical foramen (AF), and at 1.0 mm short of the AF. Methodology. Thirty-eight mandibular premolars had their real lengths previously determined. Electronic measurements were determined at 1.0 mm, followed by measurements at 0.0 mm, performed in triplicate. Results. Precision of devices at 1.0 mm and 0.0 mm were: 94.7% and 97.4%, respectively (Root ZX); 78.9% and 97.4% (RomiApex D-30); and 76.3% and 97.4% (Ipex). Although no statistical differences were observed between the EALs at 0.0, at 1.0 mm Root ZX performed significantly better than the others. Conclusion. The EALs had acceptable precision when measuring the working length at the AF. However, when used at levels short of the AF, only Root ZX did not suffer a significant negative effect on precision. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e57-e61)
Resumo:
Introduction: The aim of this study was to compare the influence of preflaring on the accuracy of 4 electronic apex locators (EALs): Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex Locator, and Apex DSP. Methods: Forty extracted teeth were preflared by using S1 and SX ProTaper instruments. The working length was established by reducing 1 mm from the total length (TL). The ability of the EALs to detect precise (-1 mm from TL) and acceptable (-1+/-0.5 mm from TL) measurements in unflared and preflared canals was determined. Results: The precise and acceptable (P/A) readings in unflared canals for Root ZX, Elements Diagnostic Unit and Apex Locator, Mini Apex and Apex DSP were 50%/97.5%, 47.5%/95%, 50%/97.5%, and 45%/67.5%, respectively. For preflared canals, the readings were 75%/97.5%, 55%/95%, 75%/97.5%, and 60%/87.5%, respectively. For precise criteria, the preflared procedure increased the percentage of accurate electronic readings for the Root ZX and the Mini Apex Locator (P < .05). For acceptable criteria, no differences were found among Root ZX, Elements Diagnostic Unit and Apex Locator, and Mini Apex Locator (P > .05). Fisher test indicated the lower accuracy for Apex DSP (P < .05). Conclusions: The Root ZX and the Mini Apex Locator devices increased significantly the precision to determine the real working length after the preflaring procedure. All the EALs showed an acceptable determination of the working length between the ranges of+/-0.5mm except for the Apex DSP device, which had the lowest accuracy. (J Endod 2009;35:1300-1302)
Resumo:
The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.
Resumo:
Background: Matrix metalloproteinase-9 (MMP-9) is involved in the degradation of the extracellular matrix during physiological and pathological processes. Two functional polymorphisms [C(-1562)T and microsatellite (CA)(13-25)] in the promoter region of the MMP-9 gene have been associated with several diseases. The aim of this study was to examine whether these MMP-9 polymorphisms and haplotypes are linked with plasma MMP-9 variations in healthy subjects. Methods: We studied 177 healthy male white volunteers (age range 20-55 years) who were non-smokers and not taking any medication. Genomic DNA was extracted from whole blood and genotypes for the C(-1562)T and the microsatellite (CA)(n) polymorphisms were determined. MMP-9 levels were measured in plasma samples by gelatin zymography. Results: The frequency of the alleles C and T for the C(-1562)T polymorphism were 90% and 10%, respectively. The frequency of the alleles with less than 21 CA repeats Q and with 21 repeats or higher (H) were 47% and 53%, respectively. We found no differences in plasma MMP-9 levels among the genotype groups or among different haplotypes (all p > 0.05). Conclusions: These findings suggest that functional polymorphisms in the promoter of the MMP-9 gene are not linked with significant plasma MMP-9 variations in healthy subjects.