995 resultados para FAAS determinations


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solid phase extraction procedure using Amberlite XAD-1180/Pyrocatechol violet (PV) chelating resin for the determination of iron and lead ions in various environmental samples was established. The procedure is based on the sorption of lead(II) and iron(III) ions onto the resin at pH 9, followed by elution with 1 mol/L HNO3 and determination by flame atomic absorption spectrometry. The influence of alkaline, earth alkaline and some transition metals, as interferents, are discussed. The recoveries for the spiked analytes were greater than 95%. The detection limits for lead and iron by FAAS were 0.37 µg/L and 0.20 µg/L, respectively. Validation of the method described here was performed by using three certified reference materials (SRM 1515 Apple Leaves, SRM 2711 Montana Soil and NRCC-SLRS-4 Riverine Water). The procedure was successfully applied to natural waters and human hair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pantoea agglomerans strains are among the most promising biocontrol agents for avariety of bacterial and fungal plant diseases, particularly fire blight of apple and pear. However, commercial registration of P. agglomerans biocontrol products is hampered because this species is currently listed as a biosafety level 2 (BL2) organism due to clinical reports as an opportunistichuman pathogen. This study compares plant-origin and clinical strains in a search for discriminating genotypic/phenotypic markers using multi-locus phylogenetic analysis and fluorescent amplified fragment length polymorphisms (fAFLP) fingerprinting.Results: Majority of the clinical isolates from culture collections were found to be improperly designated as P. agglomerans after sequence analysis. The frequent taxonomic rearrangements underwent by the Enterobacter agglomerans/Erwinia herbicola complex may be a major problem in assessing clinical associations within P. agglomerans. In the P. agglomerans sensu stricto (in the stricter sense) group, there was no discrete clustering of clinical/biocontrol strains and no marker was identified that was uniquely associated to clinical strains. A putative biocontrol-specific fAFLP marker was identified only in biocontrol strains. The partial ORF located in this band corresponded to an ABC transporter that was found in all P. agglomerans strains. Conclusion: Taxonomic mischaracterization was identified as a major problem with P.agglomerans, and current techniques removed a majority of clinical strains from this species. Although clear discrimination between P. agglomerans plant and clinical strains was not obtained with phylogenetic analysis, a single marker characteristic of biocontrol strains was identified whichmay be of use in strain biosafety determinations. In addition, the lack of Koch's postulate fulfilment, rare retention of clinical strains for subsequent confirmation, and the polymicrobial nature of P. agglomerans clinical reports should be considered in biosafety assessment of beneficial strains in this species

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biosensors were developed by immobilization of gilo (Solanum gilo) enzymatic extract on chitosan biopolymers using three different procedures: glutaraldehyde, carbodiimide/glutaraldehyde and epichlorohydrin/glutaraldehyde. The best biosensor performance was obtained after the immobilization of peroxidase on chitosan with epichlorohydrin/glutaraldehyde. Linear analytical curves for hydroquinone concentrations from 2.5x10-4 to 4.5x10-3 mol L-1 with a detection limit of 2.0x10-6 mol L-1 and recovery of hydroquinone ranging from 95.1 to 105% were obtained. The relative standard deviation was < 1.0 % for a solution of 3.0x10-4 mol L-1 hydroquinone and 2.0x10-3 mol L-1 hydrogen peroxide in 0.1 mol L-1 phosphate buffer solution at pH 7.0 (n=8). The lifetime of this biosensor was 6 months (at least 300 determinations).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of Zn, Fe, Pb, Ni and Cu by the flame atomic absorption spectrometry technique. Sulphanilic acid was added to oil samples, the mixture coked and the coke ashed at 550 ºC. The solutions of the ash were analysed by flame AAS for these metals. The quantification limits were 38.250 µg g-1 for Zn, 4.550 µg g-1 for Fe, 1.562 µg g-1 for Pb, 1.450 µg g-1 for Ni, and 0.439 µg g-1 for Cu. The determinations, in lubricating oil, showed good precision and accuracy with recoveries between 90 and 110 %, indicating a negligible matrix effect in the experiments using addition of analyte, with relative standard deviation lower than 5%. The results for analysis of wastewater contamined by theses lubricants showed a very high relative standard deviation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A preconcentration method based on the use of Saccharomyces cerevisiae as sorbent material is proposed for the determination of Cd(II) in river water. The solid phase extraction was performed in batch mode and the determination of the analyte in the solid phase was easily carried out by introducing a slurry of the yeast (0.0625 g / 2.5 mL) directly into the ICP OES. A limit of detection of 0.11 µg L-1 and a sample throughput in the range of 4 - 54 sample h-1 were obtained. Determinations of cadmium in a certified sample and in real river water samples were in excellent agreement with the expected values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the development of multiple square wave voltammetry and the possibilities of its use for electroanalytical determinations of organic and inorganic compounds with the improvement of the signal-to-noise ratios and detection limits 2-3 orders of magnitude lower than those obtained with conventional square wave voltammetry. The theoretical aspects and analytical applications were demonstrated as an increased analytical response (current) and application of different pulse modes for different redox processes. Preliminary results obtained for several redox systems using different electrode surfaces are shown, demonstrating also that MSWV represents an excellent alternative for the determination of ultra-traces of organic and inorganic compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A thorough critical analysis of the theoretical relationships between the bond-angle dispersion in a-Si, Δθ, and the width of the transverse optical Raman peak, Γ, is presented. It is shown that the discrepancies between them are drastically reduced when unified definitions for Δθ and Γ are used. This reduced dispersion in the predicted values of Δθ together with the broad agreement with the scarce direct determinations of Δθ is then used to analyze the strain energy in partially relaxed pure a-Si. It is concluded that defect annihilation does not contribute appreciably to the reduction of the a-Si energy during structural relaxation. In contrast, it can account for half of the crystallization energy, which can be as low as 7 kJ/mol in defect-free a-Si

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to obtain, purify and characterize biochemically a peroxidase from Copaifera langsdorffii leaves (COP). COP was obtained by acetone precipitation followed by ion-exchange chromatography. Purification yielded 3.5% of peroxidase with the purification factor of 46.86. The COP optimum pH is 6.0 and the temperature is 35 ºC. COP was stable in the pH range of 4.5 to 9.3 and at temperatures below 50.0 ºC. The apparent Michaelis-Menten constants (Km) for guaiacol and H2O2 were 0.04 mM and 0.39 mM respectively. Enzyme turnover was 0.075 s-1 for guaiacol and 0.28 s-1 for hydrogen peroxide. Copaifera langsdorffii leaves showed to be a rich source of active peroxidase (COP) during the whole year. COP could replace HRP, the most used peroxidase, in analytical determinations and treatment of industrial effluents at low cost.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to investigate the copper electrode behavior in the voltammetric determination of glyphosate. The best conditions for this determination are phosphate buffer 0.05 mol L-1 and pH 7.3, and the peak potential is observed at 187 mV. LD and LQ values are 59 µg L-1 e 196 µg L-1, respectively. A water sample was analysed for glyphosate and identical results were obtained by using the analytical curve and the standard addition method. The comparison with a voltammetric method with Hg electrode, after a reaction with nitrite, showed quite concordant results for the analysis of the surface water sample. Therefore, the proposed method can be applied to direct determinations of the herbicide in waters, decreasing the time of analysis; besides, the method is in agreement with the "green chemistry" concept.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the artificial neural networks (ANN) and partial least squares (PLS) regression were applied to UV spectral data for quantitative determination of thiamin hydrochloride (VB1), riboflavin phosphate (VB2), pyridoxine hydrochloride (VB6) and nicotinamide (VPP) in pharmaceutical samples. For calibration purposes, commercial samples in 0.2 mol L-1 acetate buffer (pH 4.0) were employed as standards. The concentration ranges used in the calibration step were: 0.1 - 7.5 mg L-1 for VB1, 0.1 - 3.0 mg L-1 for VB2, 0.1 - 3.0 mg L-1 for VB6 and 0.4 - 30.0 mg L-1 for VPP. From the results it is possible to verify that both methods can be successfully applied for these determinations. The similar error values were obtained by using neural network or PLS methods. The proposed methodology is simple, rapid and can be easily used in quality control laboratories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the isolation of the furanocassane-type diterpene, named vinhaticoic acid, along with beta-farnesene and spatulenol from fruit shells of D. lacunifera. Structural determinations were accomplished by chemical derivatization and spectral analysis, including 1D and 2D NMR and X-ray crystallography. The fatty portion was extracted from the fruit kernels, transesterfied and analysed by HRGC/MS. Oleic acid (75.8 ± 4.3%) was the major component. Essential oil extracted from the fruit shells of D. lacunifera was analysed by HRGC/MS and nine sesquiterpenes were identified; beta-farnesene (48.6%) and spatulenol (21.61%) were the major constituents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method for determining copper by solid phase spectrophotometry (SPS) was optimized using the Doehlert design. Copper(II) was sorbed on a styrene-divinylbenzene anion-exchange resin as a Cu(II)-1-(2-pyridylazo)-2-naphthol (PAN) complex, at pH 7.0. Resin phase absorbances at 560 and 800 nm were measured directly. The detection limit was found to be 2.5 µg L-1. The relative standard deviation on ten replicate determinations of 10 µg Cu(II) in 1000 mL samples was 1.1%. The linear range of the determination was 5.0-100 µg L-1. The method was applied successfully to the determination of Cu(II) in natural water and vegetable samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple cloud point extraction procedure is presented for the preconcentration of copper in various samples. After complexation by 4-hydroxy-2-mercapto-6-propylpyrimidine (PTU), copper ions are quantitatively extracted into the phase rich in Triton X-114 after centrifugation. Methanol acidified with 0.5 mol L-1 HNO3 was added to the surfactant-rich phase prior to its analysis by flame atomic absorption spectrometry (FAAS). Analytical parameters including concentrations for PTU, Triton X-114 and HNO3, bath temperature, centrifugation rate and time were optimized. The influences of the matrix ions on the recoveries of copper ions were investigated. The detection limits (3SDb/m, n=4) of 1.6 ng mL-1 along with enrichment factors of 30 for Cu were achieved. The proposed procedure was applied to the analysis of environmental samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were carried out against calibration solutions prepared in ethanol. Recovery tests were made in seven commercial ethanol fuel samples with values between 90 and 120%. Limits of detection were 0.1 µg L-1 for Cd and 0.3 µg L-1 for Pb. Certified water samples (APS 1071, APS 1033, NIST 1643d, NIST 1640) were also used to evaluate accuracy and recoveries from 86.8% to115% were obtained.