942 resultados para Energy quality


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Addition of energy supplements to preterm formulas is an optional strategy to increase the energy intake in infants requiring fluid restriction, in conditions like bronchopulmonary dysplasia. This strategy may lead to an undesirable increase in osmolality of feeds, the maximum recommended safe limit being 400 mOsm/kg. The aim of the study was to measure the changes in osmolality of several commercialized preterm formulas after addition of glucose polymers and medium-chain triglycerides. Methods: Osmolality was measured by the freezing point depression method. Six powdered formulas with concentrations of 14 g/100 ml and 16 g/100 ml, and five ready-to-feed liquid formulas were analyzed. All formulas, were supplemented with 10% (low supplementation) or 20% (high supplementation) of additional calories, respectively, in the form of glucose polymers and medium chain triglycerides, maintaining a 1:1 glucose:lipid calorie ratio. Inter-analysis and intra-analysis coefficients of variation of the measurements were always < 3.9%. Results: The mean osmolality (mOsm/kg) of the non-supplemented formulas varied between 268.5 and 315.3 mOsm/kg, increasing by 3–5% in low supplemented formulas, and by 6–10% in high supplemented formulas. None of the formulas analyzed exceeded 352.8 mOsm/kg. Conclusion: The supplementation of preterm formulas with nonprotein energy supplements with up to 20% additional calories did not exceed the maximum recommended osmolality for neonatal feedings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho insere-se no domínio da calibração energética dos equipamentos SPT, dando seguimento ao disposto na norma EN ISO 22476-3, de aplicação obrigatória em Portugal. Para tal foi utilizada uma vara instrumentada, cuja instrumentação consiste em strain-gauges e acelerómetros piezoeléctricos. Esta instrumentação encontra-se fixa a um trecho de vara com comprimento de 60 cm e para a aquisição dos dados foi utilizado o sistema SPT Analyzer® comercializado pela firma PDI. O sistema permite registar os dados provenientes da instrumentação: sinais de um par de strain-gauges, transformados em registos de força (F1 e F2) e sinais de um par de acelerómetros, convertidos em registos de velocidade (V1 e V2) ao longo do tempo. O equipamento permite a avaliação, em tempo real, da qualidade dos registos e da energia máxima transmitida à vara em cada golpe e o conhecimento do deslocamento vertical do trem de varas ocorrido em cada golpe do martelo. Por outro lado, baseando-se no tema acima referido, pretende-se ainda desenvolver esforços no sentido de melhorar o novo método interpretativo dos resultados dos ensaios SPT e sua aplicação ao dimensionamento de estacas, dado que a previsão da capacidade de carga de estacas constitui um dos desafios da engenharia de fundações por requerer a estimativa de propriedades do solo, alterações pela execução da fundação e conhecimento do mecanismo de interacção solo-estaca. Este novo procedimento baseia-se nos princípios da dinâmica, rompendo com as metodologias até aqui consagradas, de natureza essencialmente empírica. A nova forma de interpretar os ensaios SPT, consubstanciada nos princípios de conservação de energia na cravação do amostrador SPT, irá permitir converter analiticamente o valor Nspt numa força dinâmica de reacção à penetração. A decomposição desta força dinâmica permite efectuar análises comparativas entre as resistências unitárias mobilizadas no amostrador SPT (modelo) e as mobilizadas na estaca (protótipo).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho surgiu do âmbito da Tese de Dissertação do Mestrado em Energias Sustentáveis do Instituto Superior de Engenharia do Porto, tendo o acompanhamento dos orientadores da empresa Laboratório Ecotermolab do Instituto de Soldadura e Qualidade e do Instituto Superior de Engenharia do Porto, de forma a garantir a linha traçada indo de acordo aos objectivos propostos. A presente tese abordou o estudo do impacto da influência do ar novo na climatização de edifícios, tendo como base de apoio à análise a simulação dinâmica do edifício em condições reais num programa adequado, acreditado pela norma ASHRAE 140-2004. Este trabalho pretendeu evidenciar qual o impacto da influência do ar novo na climatização de um edifício com a conjugação de vários factores, tais como, ocupação, actividades e padrões de utilização (horários), iluminação e equipamentos, estudando ainda a possibilidade do sistema funcionar em regime de “Free-Cooling”. O princípio partiu fundamentalmente por determinar até que ponto se pode climatizar recorrendo único e exclusivamente à introdução de ar novo em regime de “Free-Cooling”, através de um sistema tudo-ar de Volume de Ar Variável - VAV, sem o apoio de qualquer outro sistema de climatização auxiliar localizado no espaço, respeitando os caudais mínimos impostos pelo RSECE (Decreto-Lei 79/2006). Numa primeira fase foram identificados todos os dados relativos à determinação das cargas térmicas do edifício, tendo em conta todos os factores e contributos alusivos ao valor da carga térmica, tais como a transmissão de calor e seus constituintes, a iluminação, a ventilação, o uso de equipamentos e os níveis de ocupação. Consequentemente foram elaboradas diversas simulações dinâmicas com o recurso ao programa EnergyPlus integrado no DesignBuilder, conjugando variáveis desde as envolventes à própria arquitectura, perfis de utilização ocupacional, equipamentos e taxas de renovação de ar nos diferentes espaços do edifício em estudo. Obtiveram-se vários modelos de forma a promover um estudo comparativo e aprofundado que permitisse determinar o impacto do ar novo na climatização do edifício, perspectivando a capacidade funcional do sistema funcionar em regime de “Free-Cooling”. Deste modo, a análise e comparação dos dados obtidos permitiram chegar às seguintes conclusões: Tendo em consideração que para necessidades de arrefecimento bastante elevadas, o “Free-Cooling” diurno revelou-se pouco eficaz ou quase nulo, para o tipo de clima verificado em Portugal, pois o diferencial de temperatura existente entre o exterior e o interior não é suficiente de modo a tornar possível a remoção das cargas de forma a baixar a temperatura interior para o intervalo de conforto. Em relação ao “Free-Cooling” em horário nocturno ou pós-laboral, este revelou-se bem mais eficiente. Obtiveram-se prestações muito interessantes sobretudo durante as estações de aquecimento e meia-estação, tendo em consideração o facto de existir necessidades de arrefecimento mesmo durante a estação de aquecimento. Referente à ventilação nocturna, isto é, em períodos de madrugada e fecho do edifício, concluiu-se que tal contribui para um abaixamento do calor acumulado durante o dia nos materiais construtivos do edifício e que é libertado ou restituído posteriormente para os espaços em períodos mais tardios. De entre as seguintes variáveis, aumento de caudal de ar novo insuflado e o diferencial de temperatura existente entre o ar exterior e interior, ficou demonstrado que este último teria maior peso contributivo na remoção do calor. Por fim, é ponto assente que de um modo geral, um sistema de climatização será sempre indispensável devido a cargas internas elevadas, requisitos interiores de temperatura e humidade, sendo no entanto aconselhado o “Free- Cooling” como um opção viável a incorporar na solução de climatização, de forma a promover o arrefecimento natural, a redução do consumo energético e a introdução activa de ar novo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the past years wireless sensor networks (WSNs) have been coined as one of the most promising technologies for supporting a wide range of applications. However, outside the research community, few are the people who know what they are and what they can offer. Even fewer are the ones that have seen these networks used in real world applications. The main obstacle for the proliferation of these networks is energy, or the lack of it. Even though renewable energy sources are always present in the networks environment, designing devices that can efficiently scavenge that energy in order to sustain the operation of these networks is still an open challenge. Energy scavenging, along with energy efficiency and energy conservation, are the current available means to sustain the operation of these networks, and can all be framed within the broader concept of “Energetic Sustainability”. A comprehensive study of the several issues related to the energetic sustainability of WSNs is presented in this thesis, with a special focus in today’s applicable energy harvesting techniques and devices, and in the energy consumption of commercially available WSN hardware platforms. This work allows the understanding of the different energy concepts involving WSNs and the evaluation of the presented energy harvesting techniques for sustaining wireless sensor nodes. This survey is supported by a novel experimental analysis of the energy consumption of the most widespread commercially available WSN hardware platforms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To analyze whether quality of life in active, healthy elderly individuals is influenced by functional status and sociodemographic characteristics, as well as psychological parameters. METHODS: Study conducted in a sample of 120 active elderly subjects recruited from two open universities of the third age in the cities of São Paulo and São José dos Campos (Southeastern Brazil) between May 2005 and April 2006. Quality of life was measured using the abbreviated Brazilian version of the World Health Organization Quality of Live (WHOQOL-bref) questionnaire. Sociodemographic, clinical and functional variables were measured through crossculturally validated assessments by the Mini Mental State Examination, Geriatric Depression Scale, Functional Reach, One-Leg Balance Test, Timed Up and Go Test, Six-Minute Walk Test, Human Activity Profile and a complementary questionnaire. Simple descriptive analyses, Pearson's correlation coefficient, Student's t-test for non-related samples, analyses of variance, linear regression analyses and variance inflation factor were performed. The significance level for all statistical tests was set at 0.05. RESULTS: Linear regression analysis showed an independent correlation without colinearity between depressive symptoms measured by the Geriatric Depression Scale and four domains of the WHOQOL-bref. Not having a conjugal life implied greater perception in the social domain; developing leisure activities and having an income over five minimum wages implied greater perception in the environment domain. CONCLUSIONS: Functional status had no influence on the Quality of Life variable in the analysis models in active elderly. In contrast, psychological factors, as assessed by the Geriatric Depression Scale, and sociodemographic characteristics, such as marital status, income and leisure activities, had an impact on quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The scientific evidence supporting the management of the chronically ill in a positive psychological perspective in opposition to traditional pathological approach is scarce. This study examines issues associated with recovery of health status in heart failure, in particular hope, affection, and happiness. We use a longitudinal study of 128 symptomatic patients who after medical intervention reported improved quality of life and function at 3-month follow-up. We evaluated the contribution of happiness, hope and affection, individually and as a whole, in the quality of life and functionality of individuals with heart failure. Happiness (Subjective Happiness Scale), Hope (HOPE Scale), and affection (PANAS (positive and negative affect schedule)) were determined before medical intervention. Individually, we found that happiness is correlated with the quality of life and functionality, hope to self-efficacy dimension of the quality of life scale, positive affect to functionality and negative affect with symptoms dimension, quality of life dimension, and overall sum of the quality of life scale. Overall, we found that happiness has a unique contribution to the quality of life, except in self-efficacy dimension where hope takes this contribution and positive affect has a unique contribution to the functionality in this short-term follow-up. The results highlight the importance of positive variables to health outcomes for people with heart failure and should be considered in intervention programs for this syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Natureza Científica para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Edificações

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente relatório descreve o trabalho de estágio efectuado na empresa Curtumes Aveneda, Lda com o objectivo de optimizar recursos como a água e energia. Foi realizado um diagnóstico energético que permitiu concluir que o consumo de energia na empresa é de 300 tep/ano, pelo que a empresa não é obrigada a adoptar as medidas de Regulamento de Gestão do Consumo de Energia (RGCE). O mesmo diagnóstico aponta para a existência de ineficiências, nomeadamente na tinturaria. Assim, foi projectado um sistema de controlo para adição de água na tinturaria com o intuito de reduzir o consumo de energia e água, e também melhorar a qualidade dos processos de tinturaria, dado que a adição de água é feita manualmente sem controlo de quantidade. Após consulta de fornecedor, o investimento em equipamento para tal sistema é de 10.012,00€ Foi desenvolvido um processo de recurtume compacto no sentido de promover a redução do consumo de água e de energia. Tal processo, quando comparado com um processo normal da empresa, gera uma redução de energia eléctrica no valor de 6.157,05 €/ano, uma redução no consumo de energia térmica da ordem de 904,00 €/ano, e ainda uma redução do consumo de água na ordem de 962 m3/ano correspondente a uma redução de 2.998,76 €/ano no tratamento de efluentes. Outras medidas foram sugeridas, mas sem uma fundamentação técnica e científica suficiente pelo que carecem de um estudo pormenorizado, como a instalação de arrancadores progressivos nos motores dos fulões, a optimização do aquecimento do ar de secagem na estufa com eventual recurso a painéis solares, e a optimização do funcionamento da caldeira dado o seu baixo rendimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho foi realizado no âmbito da disciplina de Dissertação/Estágio do ramo de Optimização Energética na Indústria Química, do Mestrado em Engenharia Química do Instituto Superior de Engenharia do Porto e foi desenvolvido na empresa GreenWatt. O principal objectivo é efectuar uma auditoria energética e uma auditoria QAI a uma clínica de fisiatria de forma a preparar as ferramentas necessárias para a Certificação Energética e da QAI no enquadramento do Sistema de Certificação Energética. Na auditoria QAI foram analisados parâmetros físicos - temperatura, humidade relativa e partículas respiráveis PM10, parâmetros químicos - CO2, CO, O3, COVs, HCOH e o radão, e ainda parâmetros microbiológicos - bactérias, fungos e legionella. Na auditoria energética foi feita a caracterização dos vectores de energia utilizados no edifício, nomeadamente, gás natural e electricidade. Para esta caracterização efectuou-se um levantamento de toda a informação disponível relativa aos combustíveis utilizados, iluminação instalada, outros equipamentos consumidores de energia e perfis de utilização. Com recurso a analisadores de energia foram ainda medidos os consumos eléctricos do edifício. Com suporte nos dados provenientes da auditoria energética e das facturas anuais efectuou-se a validação da simulação dinâmica do edifício. Esta simulação é a base do cálculo do IEEnominal do edifício. Os resultados da auditoria QAI, permitiram verificar que existem valores nãoregulamentares em relação aos compostos orgânicos voláteis, fungos e bactérias. Da auditoria energética concluiu-se que o principal consumo de energia é o gás natural utilizado pelas caldeiras existentes. Este valor representa cerca de 81% do consumo total de energia, reproduzindo os mesmos resultados obtidos pela desagregação das facturas energéticas. No que respeita à electricidade concluiu-se que as bombas de água e os equipamentos eléctricos são os maiores consumidores deste vector, com, respectivamente, 53% e 23% do consumo total de energia eléctrica. Após a realização da simulação dinâmica, com base nos levantamentos realizados no edifício e na auditoria energética efectuada, obteve-se uma fotografia do edifício no que respeita ao seu desempenho energético, e calculou-se um IEEnominal de 40,54 kgep/m2.ano o que qualifica o edifício com uma Classe Energética E. O valor de CO2 emitido por este edifício em termos nominais, anualmente, é de 76,39 toneladas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A indústria da construção, nomeadamente no sector da edificação, baseia-se essencialmente em métodos de construção tradicional. Esta indústria é caracterizada pelo consumo excessivo de matérias-primas, de recursos energéticos não renováveis e pela elevada produção de resíduos. Esta realidade é de todo incompatível com os desígnios do desenvolvimento sustentável, nos quais se procura a conveniência harmoniosa entre as dimensões ambiental, social e económica. O desafio da sustentabilidade, colocado à actividade da construção, tem motivado abordagens distintas, não só por parte das várias especialidades da engenharia, como também da arquitectura. É nesta perspectiva, que o presente modelo pretende ser um contributo para uma abordagem inovadora, introduzindo linhas de intervenção e de orientação, para apoiar e estimular o desenvolvimento de soluções sustentáveis em edifícios habitacionais, em qualquer fase do ciclo de evolução de um projecto e das várias especialidades do mesmo. Assim, no sentido de optimizar os recursos envolvidos no projecto são expostas estratégias de intervenção, com os seguintes objectivos: optimização do potencial do local, preservação da identidade regional e cultural, minimização do consumo de energia, utilização de materiais e produtos de baixo impacto ambiental, redução do consumo de água, redução da produção de emissões, resíduos e outros poluentes, adequada qualidade do ambiente interior e optimização das fases de operação e manutenção. A ferramenta apresentada surge como um instrumento facilitador para a equipa de projectistas, e que se esta adaptada para o desenvolvimento de projectos de edifícios de habitação, dada a génese dos métodos utilizados. As soluções de sustentabilidade apresentadas neste manual emanam dos sistemas de certificação LíderA, LEED, BREEAM e SBToolpt. O modelo encontra-se estruturado, no que às fases de projecto diz respeito, de acordo com os requisitos expressos na Portaria 701-H/2008 de 29 de Julho, tendo sido igualmente seguido o descrito para os respectivos intervenientes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado, Estudos Integrados dos Oceanos, 15 de Março de 2016, Universidade dos Açores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A evolução tecnológica a que se assistiu nas últimas décadas tem sido um dos principais fatores da necessidade de utilização de energia elétrica. Consequentemente, remodelações tanto a nível de equipamentos na rede de distribuição como da qualidade de serviço têm sido determinantes para fazer face a uma evolução crescente do consumo de energia elétrica por parte da sociedade. Esta evolução tem afetado significativamente o desempenho dos sistemas de proteção e automatismos associados, sendo estes cada vez mais fiáveis e proporcionando maior segurança tanto aos ativos da rede como a pessoas. No entanto, esta evolução tem tido também impacto nas linhas de distribuição em média tensão, estando estas a evoluir de rede aérea para linhas mistas de distribuição. As linhas mistas de distribuição têm diferentes desempenhos técnicos e económicos no que respeita aos sistemas de proteção e respetivos automatismos de religação automática. Neste trabalho são analisados alguns parâmetros que têm influência na atuação das proteções e respetivos automatismos de religação.