999 resultados para Comparação de médias
Resumo:
The efficiency for immobilizing microbial Candida rugosa lipase on a hybrid matrix of polysiloxane polyvinyl alcohol, by adsorption, covalent coupling and encapsulation was compared. The activities of immobilized derivatives were evaluated using p-nitrophenylpalmitate (hydrolysis) and butyric acid and butanol (esterification) as substrates. Operational stability and storage tests were also performed. Among the procedures tested, the proposed matrix was efficient for immobilizing C. rugosa lipase by adsorption and covalent coupling techniques and unsuitable for encapsulation purposes. The results reveal that better catalytic properties in both aqueous and organic media were demonstrated by the covalent coupling POS-PVA immobilized lipase, including also satisfactory half-life and good storage stability.
Resumo:
N-heterocyclic carbenes (NHCs) have become of considerable importance in modern organometallic chemistry and homogeneous catalysis. There are several advantages in the use NHCs over their phosphorus analogues, which explains the enormous development of NHC ligands in the field of organometallic catalysis in the past few years. In this article, we present an overview of the importance of the catalysts containing NHC ligands, their synthesis, some pertinent synthetic applications, and a brief comparison with other catalysts.
Resumo:
This article describes an experiment designed to teach quantitative determination in gas chromatography (GC) in Organic and Analytical Chemistry practical classes. The experiment consisted of extracting and analyzing eugenol from clove seeds to perform a quantitative approach aimed at comparing results obtained by external and internal calibration procedures. Therefore, this experiment proved to be very effective tool to enhance students awareness on the need to understand different types of calibration in GC and on how to avoid common experimental errors, and to find the best ways to eliminate their interference during the quantitative analysis phase.
Resumo:
The evaluation of uncertainty associated with an analytic result is an essential part of the measurement process. Recently, several approaches to evaluate the uncertainty in measurement have been developed. Here, the gas chromatography assay uncertainty for natural gas is compared by some of these approaches: the guide to the expression of uncertainty in measurement (GUM) approach, top-down approach (reproducibility estimate from an inter-laboratory study), Barwick & Ellison (data from validation), study of variability and fuzzy approach. The comparison shows that GUM, Barwick & Ellison and fuzzy approaches lead to comparable uncertainty evaluations, which does not happen with the top-down approach and study of variability by the absence of data normality.
Resumo:
An analytical comparison of three different techniques for quantitative profile of esters in cachaça is reported. The Ministério da Agricultura Pecuária e Abastecimento (MAPA) recommends the use of GC/FID or volumetry. Despite being laborious and lacking in chemical speciation, the volumetric technique for total ester content shows to be appropriate, reproducible, and accurate for the analysis of cachaça. However, the GC/FID suggested by MAPA, considering only ethyl acetate, shows inaccuracy, underestimating the total ester content by a median factor of 72%, mainly due to the absence of ethyl lactate analysis. On the other hand, the GC/MS technique that comprises the analysis and speciation of nine esters, including ethyl lactate, proved to be reproducible, simple, fast and accurate for the analysis of total ester content in cachaça. Thus, the total ester content results obtained using GC/FID must be considered with precaution.
Resumo:
The CBS-4M, CBS-QB3, G2, G2(MP2), G3 and G3(MP2) model chemistry methods have been used to calculate proton and electron affinities for a set of molecular and atomic systems. Agreement with the experimental value for these electronic properties is quite good considering the uncertainty in the experimental data. A comparison among the six theories using statistical analysis (average value, standard deviation and root-mean-square) showed a better performance of CBS-QB3 to obtain these properties.
Resumo:
In this work, four different process configurations, including three simultaneous saccharification and fermentation (SSF) schemes and one separate hydrolysis and fermentation (SHF) scheme, were compared, at 8% water-insoluble solids, regarding ethanol production from steam-pretreated and alkali-delignified sugar cane bagasse. Two configurations included a 16 h lasting enzymatic presaccharification prior to SSF, and the third one was a classical SSF without presaccharification. Cellulose conversion was higher for the delignified bagasse, and higher in SSF experiments than in SHF. The highest cellulose-to-ethanol conversion (around 60% in 24 h) and maximum ethanol volumetric productivities (0.29-0.30 g/L.h) were achieved in the presaccharification-assisted SSF.
Resumo:
The present work aimed modify chemically the chitosan (QTS) surface to obtain a reticulate chitosan quaternary ammonium salt (SAQQR), and compare this anionic exchanger with an commercial ion exchanger in the extraction of available phosphorus in soils. The results showed that the two exchangers are identical, extracting similar and proportional quantities of available phosphorus in the studied soils, and the anionic exchanger of SAQQR provides a high chemical stability, not affected by the pH difference of soils.
Resumo:
Speciation of metals in a synthetic freshwater was comparatively evaluated using Anodic Stripping Voltammetry, Diffusive Gradients in Thin Films and a Chemical Equilibrium Model. The labile fractions of Cu and Zn quantified by DGT were similar to the ones measured by ASV. The labile species of Cd and Pb could not be determined by both experimental methods due to the formation of inert complexes with organic ligands in the sample. Despite the differences among the methods, the speciation results obtained by the use of DGT and ASV agreed well with predictions made by the chemical equilibrium model.
Resumo:
Ophthalmic viscosurgical devices (OVD) are materials injected in intraocular space during cataract removal to reduce trauma in the patient's eye. Three Brazilian commercially available OVDs (Medilon®, Metilcelulose® and Ofthyal®) were evaluated as well as formulations based on Dimorphandra gardneriana galactomannan. Viscosity and viscoelastic parameters, such as viscosity at zero shear, pseudoplasticity index, elastic and viscous moduli, relaxation time, were determined and compared. Characteristics of an effective OVD were proposed. None of the Brazilian devices studied fulfill the rheological requirements. Only the galactomannan at 3% concentration showed potential to be used as effective OVD.
Resumo:
Interlaboratorial comparison of the determination of hardness and chloride in water had been performed by 38 and 37 laboratories, respectively. In all cases the participating laboratories used its routine methods. Homogeneity and stability testing were performed on the samples sent to the laboratories. The codified results are graphically reported and compared to assigned value, determined by the consensus of the laboratories. Satisfactory results were obtained for 71 and 73% of the laboratories, considering hardness and chloride determination, respectively.
Resumo:
Multivariate models were developed using Artificial Neural Network (ANN) and Least Square - Support Vector Machines (LS-SVM) for estimating lignin siringyl/guaiacyl ratio and the contents of cellulose, hemicelluloses and lignin in eucalyptus wood by pyrolysis associated to gaseous chromatography and mass spectrometry (Py-GC/MS). The results obtained by two calibration methods were in agreement with those of reference methods. However a comparison indicated that the LS-SVM model presented better predictive capacity for the cellulose and lignin contents, while the ANN model presented was more adequate for estimating the hemicelluloses content and lignin siringyl/guaiacyl ratio.
Resumo:
This paper reports on a modification of the procedures originally described in the French Pharmacopoeia for the UV-visible spectrometric analysis of flavonoids, and proposes a validation of the method and its application in the determination of total flavonoids from sugarcane (Saccharum officinarum) leaves and vinasse. An analysis of precision and accuracy revealed a low relative standard deviation (< 5.0%) and a good recovery percentages (99.79 and 98.34%). A comparison of the spectrometric results against those obtained by high performance liquid chromatography (HPLC-UV) demonstrated complete compatibility between the modified French Pharmacopoeia (spectrometric) and HPLC-UV methods
Resumo:
Sulfasalazine is a prodrug used in the treatment of the Chron's disease and rheumatoid arthritis. Two analytical methods for analysis of sulfasalazine in oral suspension were validated using Spectrophotometric and HPLC. There is not any pharmacopoeic method to assay sulfasalazine in oral suspension. The methods are insurance and fast execution for the quality control. Both, suspension and tablets 500 mg (Azulfin®) had been analyzed by methods using UV/VIS and HPLC and the results were satisfactory.
Resumo:
Three samples of hydrotalcite-like materials (HTC) were synthesized and their structural characteristics were compared with two HTCs obtained commercially. Thermal analyses, FT-IR, PXRD and textural analyses were used to investigate the structural differences between commercial and synthetic samples. Particularly, the memory effect was observed at temperature higher than 600 ºC. The Rietveld refinements were obtained with expressive accuracy and the statistical parameters of goodness of fit are quite satisfactory. In conclusion, the procedures adopted in synthesis of HTC produced crystalline materials with high surface area materials.