992 resultados para Automated Test
Resumo:
Conocer cuál es la personalidad de aquellos que acceden a nuestras Escuelas y que en pocos años se convertirán en futuros profesionales de Enfermería, ha sido el objetivo de un estudio llevado a cabo por la Comisión de Docencia de la E.U.E. de Barcelona. En él se realiza un análisis comparativo de los perfiles de personalidad de los estudiantes admitidos en la E.U.E. de Barcelona y los candidatos pre-inscritos en dicha escuela en 1983, frente a estudiantes de Enfermería americanas y británicas y los candidatos a estudiantes de Medicina de la Universidad de Navarra.
Resumo:
Living bacteria or yeast cells are frequently used as bioreporters for the detection of specific chemical analytes or conditions of sample toxicity. In particular, bacteria or yeast equipped with synthetic gene circuitry that allows the production of a reliable non-cognate signal (e.g., fluorescent protein or bioluminescence) in response to a defined target make robust and flexible analytical platforms. We report here how bacterial cells expressing a fluorescence reporter ("bactosensors"), which are mostly used for batch sample analysis, can be deployed for automated semi-continuous target analysis in a single concise biochip. Escherichia coli-based bactosensor cells were continuously grown in a 13 or 50 nanoliter-volume reactor on a two-layered polydimethylsiloxane-on-glass microfluidic chip. Physiologically active cells were directed from the nl-reactor to a dedicated sample exposure area, where they were concentrated and reacted in 40 minutes with the target chemical by localized emission of the fluorescent reporter signal. We demonstrate the functioning of the bactosensor-chip by the automated detection of 50 μgarsenite-As l(-1) in water on consecutive days and after a one-week constant operation. Best induction of the bactosensors of 6-9-fold to 50 μg l(-1) was found at an apparent dilution rate of 0.12 h(-1) in the 50 nl microreactor. The bactosensor chip principle could be widely applicable to construct automated monitoring devices for a variety of targets in different environments.
Resumo:
Recent standardization efforts in e-learning technology have resulted in a number of specifications, however, the automation process that is considered essential in a learning management system (LMS) is a lessexplored one. As learning technology becomes more widespread and more heterogeneous, there is a growing need to specify processes that cross the boundaries of a single LMS or learning resource repository. This article proposes to obtain a specification orientated to automation that takes on board the heterogeneity of systems and formats and provides a language for specifying complex and generic interactions. Having this goal in mind, a technique based on three steps is suggested. The semantic conformance profiles, the business process management (BPM) diagram, and its translation into the business process execution language (BPEL) seem to be suitable for achieving it.
Resumo:
Automation or semi-automation of learning scenariospecifications is one of the least exploredsubjects in the e-learning research area. There isa need for a catalogue of learning scenarios and atechnique to facilitate automated retrieval of stored specifications. This requires constructing anontology with this goal and is justified inthis paper. This ontology must mainlysupport a specification technique for learning scenarios. This ontology should also be useful in the creation and validation of new scenarios as well as in the personalization of learning scenarios or their monitoring. Thus, after justifying the need for this ontology, a first approach of a possible knowledge domain is presented. An example of a concrete learning scenario illustrates some relevant concepts supported by this ontology in order to define the scenario in such a way that it could be easy to automate.
Resumo:
One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.
Resumo:
The fiscal policy rule implicit in the Stability and Growth Pact, has been rationalised as a way to ensure that national fiscal policies remain sustainable within the EU, thereby endorsing the independence of the ECB. We empirically examine the sustainability of European fiscal policies over the period 1970-2001. The intertemporal government budget constraint provides a test based on the cointegration relation between government revenues, expenditures and interest payments. Sustainability is analysed at both the national level and for a European panel. Results show that European fiscal policy has been sustainable overall, yet national experiences differ considerably.
Resumo:
The void structure of zeolites MCM-22, MCM-36 and ITQ-2 were discussed on the bases of catalytic reaction tests. The hydromerization of n-decane on bifunctional Pt/Zeolite Catalysts have been used as model reactions. Beta and ZSM-5 zeolites were used for comparison. It is concluded that all materials show features of 10MR zeolites and have also pores bigger than 12MR in this order MCM-22
Resumo:
In this technical note, we describe the construction of a low-cost computer controlled device for layer-by-layer film fabrication. The software allows to control multiple material deposition, washing and drying steps and the time for each operation. To test the device, we produced and characterized self-assembled films of conductive polymers by alternating poly(o-methoxyaniline) (POMA) and poly(3-thiophene acetic acid) (PTAA) via the layer-by-layer technique.
Resumo:
The spectrophotometric determination of Cd(II) using a flow injection system provided with a solid-phase reactor for cadmium preconcentration and on-line reagent preparation, is described. It is based on the formation of a dithizone-Cd complex in basic medium. The calibration curve is linear between 6 and 300 µg L-1 Cd(II), with a detection limit of 5.4 µg L-1, an RSD of 3.7% (10 replicates in duplicate) and a sample frequency of 11.4 h-1. The proposed method was satisfactorily applied to the determination of Cd(II) in surface, well and drinking waters.
Resumo:
The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.
Resumo:
A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.