966 resultados para Precision


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An automatic system for the direct determination of lead and tin by atomic absorption spectrometry is described. The on-line treatment of the metallic samples was obtained by anodic electrodissolution in a flow injection system. Lead was determined by flame atomic absorption spectrometry (FAAS) and tin by graphite furnace atomic absorption spectrometry (GFAAS). A computer program managed the current source and the solenoid valves that direct the fluids. Good linear correlations between absorbance and current intensity for lead and tin were observed. Results were in agreement with the certified values. Precision was always better than 5%. The recommended procedure allows the direct determination of 60 or 30 elements/h using FAAS or GFAAS, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selectivity studies for the determination of Cr(VI) using the catalytic oxidation of the o-dianisidine by hydrogen peroxide showed two distincts situations. In the first, when interferents were studied by a univariate procedure, Cr(III) and Cu(II) cause serious interferences even at the 2:1 proportion, relative to Cr(VI), while Fe(III) interfered at the 15:1 ratio and EDTA at the 10:1 ratio. On the other hand, when a multivariate investigation was performed, Cr(III) did not present any significant principal effects and its significant interaction effects were negative, in contrast to EDTA, that presented positive interaction effects although, like Cr(III), did not show significant interaction effects. In view of the interferent's action it become necessary to separate Cr(VI) by extraction with methylisobutylketone in a chloridric acid medium before its determination in vegetals and in wastewater from a cellulose industry samples. Using this procedure, the method precision is ±0,5% at the 10 ng/mL Cr(VI) concentration level. The detection and quantification limits, calculated by means of absorbance measurements of ten replicates of blank reagents were 1,1 and 3,2 ng/mL, respectively. The results obtained with real samples showed a relative standard deviation between 1,2% and 3,0% relative to their reference values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Solid-phase microextraction (SPME) has been applied to direct extraction of 11 organophosphorus pesticides in water using a 100 mm fiber polydimethylsiloxane. The method was evaluated with respect time of exposure, detection limits (LODs), linearity and precision. The detection limits (S/N = 3) depend of each pesticide and varie about ng/L levels. The linearity was satisfactory with coefficients of correlation usually greater than 0.993. The precision of the method was determined by extraction from 4.0 mg/L aqueous standard with coefficients of variation between 5.7 to 17.2%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

'Cachaça' is the Brazilian name for the spirit obtained from sugarcane. According to Brazilian regulations, it may be sold raw or with addition of sugar and may contain up to 5 mg/L of copper. Copper in "cachaça" was determined by titration with EDTA, using a homemade copper membrane electrode for end-point detection. It was found a pooled standard deviation of 0,057 mg/L and there was no significant difference between the results obtained by the potentiometric method and by flame atomic absorption spectrometry with standard addition. Among the 21 'cachaça' samples from 16 different brands analyzed, three overpassed the legal copper limit. For its characteristics of accuracy, precision, and speed, the potentiometric method may be employed advantageously in routine analysis, specially when low cost is a major concern.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this master’s thesis was to quantitatively study the reliability of market and sales forecasts of a certain company by measuring bias, precision and accuracy of these forecasts by comparing forecasts against actual values. Secondly, the differences of bias, precision and accuracy between markets were explained by various macroeconomic variables and market characteristics. Accuracy and precision of the forecasts seems to vary significantly depending on the market that is being forecasted, the variable that is being forecasted, the estimation period, the length of the estimated period, the forecast horizon and the granularity of the data. High inflation, low income level and high year-on-year market volatility seems to be related with higher annual market forecast uncertainty and high year-on-year sales volatility with higher sales forecast uncertainty. When quarterly market size is forecasted, correlation between macroeconomic variables and forecast errors reduces. Uncertainty of the sales forecasts cannot be explained with macroeconomic variables. Longer forecasts are more uncertain, shorter estimated period leads to higher uncertainty, and usually more recent market forecasts are less uncertain. Sales forecasts seem to be more uncertain than market forecasts, because they incorporate both market size and market share risks. When lead time is more than one year, forecast risk seems to grow as a function of root forecast horizon. When lead time is less than year, sequential error terms are typically correlated, and therefore forecast errors are trending or mean-reverting. The bias of forecasts seems to change in cycles, and therefore the future forecasts cannot be systematically adjusted with it. The MASE cannot be used to measure whether the forecast can anticipate year-on-year volatility. Instead, we constructed a new relative accuracy measure to cope with this particular situation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The approaches are part of the everyday of the Physical Chemistry. In many didactic books in the area of Chemistry, the approaches are validated starting from qualitative and not quantitative approaches. We elaborated some examples that allow evaluating the quantitative impact of the approaches, being considered the mistake tolerated for the approximate calculation. The estimate of the error in the approaches should serve as guide to establish the validity of the calculation, which use them. Thus, the shortcut that represents a calculation approached to substitute accurate calculations; it can be used without it loses of quality in the results, besides indicating, as they are valid the adopted criterions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Little is known about the amount of water and ash in brazilian foodstuffs and plants. The relationships between fresh, dry and ash weight were determined in 40 different biological samples. It could be an important tool when one studies biological material containing low concentration of the chemical elements. This study address to determine these relationships and to provide the amount of biological material that one needs to collect. It aims to supply information that could be used to improve the detection limit, precision and accuracy of the analytical methodology utilized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and low cost flow cell is proposed for measurements by solid-phase spectrophotometry employing a conventional spectrophotometer. The flow cell geometry allows the employment of a large amount of the solid support without causing both excessive attenuation of the radiation beam and increasing of the back-pressure. The adaptation of the flow cell in the optical path of the spectrophotometer in order to increase the precision is discussed. The flow cell characteristics were demonstrated by measurements of Co(II), employing 1-(2-tiazolylazo)-2-naphthol (TAN) immobilized on C18 bonded silica as solid support. The apparent molar absorptivity and coefficient of variation were estimated as 1.86 x 10(5) L mol-1 cm-1 and 1.4 % (n=15). A sample throughput of 40 determinations per hour and a detection limit of 15 mug L-1 (99.7 % confidence level) were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increasing attention is being paid to the use of biomarkers for determining the exposure of humans to air toxics. Biomarkers include the nonreacted toxic substance, their metabolites, or the reaction products of these toxics with naturally substances in the body. Significant progress has been made in the measurement of biomarkers during the past several years. Much of this progress has been because of the development of advanced analytical techniques for identification and quantification of the chemical species in complex matrix, such as biological fluids. The assessment of the potential cancer risk associated with exposure to benzene at occupational and non-occupational ambient is necessary because of the toxicological implications of this air pollutant. Thus, in this review, the analytical methodologies used to determine the benzene metabolites, in special, urinary muconic acid and S-phenylmercapturic acid, are described and several problems affecting the precision of these procedures are discussed. Finally, in view of the difficulty pointed out for selecting the more adequate biomarker, further studies to evaluate the human exposure levels to benzene should be done.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El present estudi descriu el procés de creació d'un sistema de localització en interiors que permet investigar les possibles diferències de la precisió de les localitzacions en entorns buits i amb presència d'altres persones. Posteriorment es presenten una sèrie de proves realitzades, s'exposen els seus resultats, així com les conclusions sobre com influencia el nombre d'usuaris a la precisió del sistema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sequential extraction procedure proposed by Tessier and total digestion were applied for the analysis of sediment samples from Tubarão River. The recoveries were between 93.5 and 102.5% for Cu and 99.2 and 111% for Pb. The precision was tipically better than 6% for Cu and 3% for Pb. Comparison of the values obtained for the total digest with the sum of the extracted fractions showed that there were no significant losses in the extraction steps so that the method can be used for the monitoring availability and mobility of these analytes. According to ten points of sampling, was possible to determined the average of labiles phases (fractions 1 and 4) for Pb and Cu: 33.70% and 18.18%, respectively; and the inert phases (fraction 5- residual): 66.30% for Pb and 81.82% for Cu.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this review it is presented some aspects of electrothermal atomic absorption spectrometry with tungsten coil (ETAW-AAS) since its beginning until the present days as well as the perspectives for this technique. Some aspects concerning its development and theoretical concepts are discussed. The analytical figures of merit such as limit of detection (LD), characteristic mass (m0), relative standard deviation (RSD), accuracy and precision are evaluated, compared and discussed considering published works. It is also evaluated its advantages, applications, limitations and instrumental development. The use of diode laser as radiation source and its perspectives to ETAW are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Documenting the distribution of radiotherapy departments and the availability of radiotherapy equipment in the European countries is an important part of HERO the ESTRO Health Economics in Radiation Oncology project. HERO has the overall aim to develop a knowledge base of the provision of radiotherapy in Europe and build a model for health economic evaluation of radiation treatments at the European level. The aim of the current report is to describe the distribution of radiotherapy equipment in European countries. Methods: An 84-item questionnaire was sent out to European countries, principally through their national societies. The current report includes a detailed analysis of radiotherapy departments and equipment (questionnaire items 2629), analyzed in relation to the annual number of treatment courses and the socio-economic status of the countries. The analysis is based on validated responses from 28 of the 40 European countries defined by the European Cancer Observatory (ECO). Results: A large variation between countries was found for most parameters studied. There were 2192 linear accelerators, 96 dedicated stereotactic machines, and 77 cobalt machines reported in the 27 countries where this information was available. A total of 12 countries had at least one cobalt machine in use. There was a median of 0.5 simulator per MV unit (range 0.31.5) and 1.4 (range 0.44.4) simulators per department. Of the 874 simulators, a total of 654 (75%) were capable of 3D imaging (CT-scanner or CBCToption). The number of MV machines (cobalt, linear accelerators, and dedicated stereotactic machines) per million inhabitants ranged from 1.4 to 9.5 (median 5.3) and the average number of MV machines per department from 0.9 to 8.2 (median 2.6). The average number of treatment courses per year per MV machine varied from 262 to 1061 (median 419). While 69% of MV units were capable of IMRT only 49% were equipped for image guidance (IGRT). There was a clear relation between socio-economic status, as measured by GNI per capita, and availability of radiotherapy equipment in the countries. In many low income countries in Southern and Central-Eastern Europe there was very limited access to radiotherapy and especially to equipment for IMRT or IGRT. Conclusions: The European average number of MV machines per million inhabitants and per department is now better in line with QUARTS recommendations from 2005, but the survey also showed a significant heterogeneity in the access to modern radiotherapy equipment in Europe. High income countries especially in Northern-Western Europe are well-served with radiotherapy resources, other countries are facing important shortages of both equipment in general and especially machines capable of delivering high precision conformal treatments (IMRT, IGRT)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diffusion coefficients provide uniquely detailed and easily interpreted information on molecular organization and phase structure. They are quite sensitive to structural changes, and to binding and association phenomena, in particular for liquid colloidal or macromolecular systems. This paper describes the principles of diffusion measurements in liquids by pulsed magnetic field gradient spin-echo (PFG-SE) NMR spectroscopy. The important PFG-SE technique known as DOSY is presented and discussed. This is a noninvasive technique that can provide individual multicomponent translational diffusion coefficients with good precision in a few minutes, without the need for radioactive isotopic labelling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermal baths to decrease ambient temperature are an indispensable tool for most research and teaching laboratories, especially those in tropical or equatorial regions. A simple and inexpensive thermal bath has been developed based on a scratched compressor. It has three possible setups for cooling: sample immersed into the bath, sample flowing through the bath, and cooling liquid flowing in a jacket around the sample. It has been tested for 40 months. The temperature ranges from room temperature to 0 °C, when using water. The repeatability is better than 3% and the precision varies from 0.5% to 2%.