Determinação de pesticidas organofosforados em água usando microextração em fase sólida e CGAR-EM


Autoria(s): Silva,Fernando Carvalho; Cardeal,Zenilda de Lourdes; Carvalho,Ciomara Rabelo de
Data(s)

01/04/1999

Resumo

Solid-phase microextraction (SPME) has been applied to direct extraction of 11 organophosphorus pesticides in water using a 100 mm fiber polydimethylsiloxane. The method was evaluated with respect time of exposure, detection limits (LODs), linearity and precision. The detection limits (S/N = 3) depend of each pesticide and varie about ng/L levels. The linearity was satisfactory with coefficients of correlation usually greater than 0.993. The precision of the method was determined by extraction from 4.0 mg/L aqueous standard with coefficients of variation between 5.7 to 17.2%.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40421999000200010

Idioma(s)

pt

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.22 n.2 1999

Palavras-Chave #organophosphorus pesticides #solid phase microextraction #GC-MS
Tipo

journal article