920 resultados para Detached resonance curves


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the K(892)*0 resonance production in Pb–Pb collisions at √sNN = 2.76 TeV with the ALICE detector at the LHC is presented. The analysis is motivated by the interest in the measurement of short-lived resonances production that can provide insights on the properties of the medium produced in heavy-ion collisions both during its partonic (Quark-Gluon Plasma) and hadronic phase. This particular analysis exploits particle identification of the ALICE Time-Of-Flight detector. The ALICE experiment is presented, with focus on the performance of the Time-Of-Flight system. The aspects of calibration and data quality controls are discussed in detail, while illustrating the excellent and very stable performance of the system in different collision environments at the LHC. A full analysis of the K*0 resonance production is presented: from the resonance reconstruction to the determination of the efficiency and the systematic uncertainty. The results show that the analysis strategy discussed is a valid tool to measure the K∗0 up to intermediate momenta. Preliminary results on K*0 resonance production at the LHC are presented and confirmed to be a powerful tool to study the physics of ultra-relativistic heavy-ion collisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

̀ qui presentato lo studio della produzione della risonanza K∗0 in collisioni p-Pb con l’esperimento ALICE presso LHC. L’elaborato si compone di una introduzione sulla natura del fenomeno studiato: la formazione del Quark Gluon Plasma (QGP), uno stato della materia fortemente interagente ad alte temperatura e densità d’energia. Vengono descritte le segnature studiate ai fini di identificare il suddetto fenomeno, riportando come esempio concreto i risultati sperimentali. Successivamente l’acceleratore di particelle, LHC, e l’esperimento, ALICE, vengono brevemente introdotti. Più in dettaglio ven- gono descritti i rivelatori di ALICE effettivamente usati per l’analisi, a cui sono dedicate sezioni approfondite. Viene infine introdotta l’analisi e le sue motivazioni. Il metodo utilizzato e lo studio degli errori da associare alla misura sono illustrati in ogni loro passo e supportati dai risultati ottenuti. La discussione finale dei risultati include il confronto con i risultati preceden- temente ottenuti da ALICE in collisioni pp e Pb-Pb e da altri esperimenti.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis provides efficient and robust algorithms for the computation of the intersection curve between a torus and a simple surface (e.g. a plane, a natural quadric or another torus), based on algebraic and numeric methods. The algebraic part includes the classification of the topological type of the intersection curve and the detection of degenerate situations like embedded conic sections and singularities. Moreover, reference points for each connected intersection curve component are determined. The required computations are realised efficiently by solving quartic polynomials at most and exactly by using exact arithmetic. The numeric part includes algorithms for the tracing of each intersection curve component, starting from the previously computed reference points. Using interval arithmetic, accidental incorrectness like jumping between branches or the skipping of parts are prevented. Furthermore, the environments of singularities are correctly treated. Our algorithms are complete in the sense that any kind of input can be handled including degenerate and singular configurations. They are verified, since the results are topologically correct and approximate the real intersection curve up to any arbitrary given error bound. The algorithms are robust, since no human intervention is required and they are efficient in the way that the treatment of algebraic equations of high degree is avoided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Advanced optical biosensor platforms exploiting long range surface plasmons (LRSPs) and responsive N-isopropylacrylamide (NIPAAm) hydrogel binding matrix for the detection of protein and bacterial pathogen analytes were carried out. LRSPs are optical waves that originate from coupling of surface plasmons on the opposite sites of a thin metallic film embedded between two dielectrics with similar refractive indices. LRSPs exhibit orders of magnitude lower damping and more extended profile of field compared to regular surface plasmons (SPs). Their excitation is accompanied with narrow resonance and provides stronger enhancement of electromagnetic field intensity that can advance the sensitivity of surface plasmon resonance (SPR) and surface plasmon-enhanced fluorescence spectroscopy (SPFS) biosensors. Firstly, we investigated thin gold layers deposited on fluoropolymer surface for the excitation of LRSPs. The study indicates that the morphological, optical and electrical properties of gold film can be changed by the surface energy of fluoropolymer and affect the performance of a SPFS biosensor. A photo-crosslinkable NIPAAm hydrogel was grafted to the sensor surface in order to serve as a binding matrix. It was modified with bio-recognition elements (BREs) via amine coupling chemistry and offered the advantage of large binding capacity, stimuli responsive properties and good biocompatibility. Through experimental observations supported by numerical simulations describing diffusion mass transfer and affinity binding of target molecules in the hydrogel, the hydrogel binding matrix thickness, concentration of BREs and the profile of the probing evanescent field was optimized. Hydrogel with a up to micrometer thickness was shown to support additional hydrogel optical waveguide (HOW) mode which was employed for probing affinity binding events in the gel by means of refractometric and fluorescence measurements. These schemes allow to reach limits of detection (LODs) at picomolar and femtomolar levels, respectively. Besides hydrogel based experiments for detection of molecular analytes, long range surface plasmon-enhanced fluorescence spectroscopy (LRSP-FS) was employed for detection of bacterial pathogens. The influence of capture efficiency of bacteria on surfaces and the profile of the probing field on sensor response were investigated. The potential of LRSP-FS with extended evanescent field is demonstrated for detection of pathogenic E. coli O157:H7 on sandwich immunoassays . LOD as low as 6 cfu mL-1 with a detection time of 40 minutes was achieved.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The membrane protein Cytochrome c Oxidase (CcO) is one of the most important functional bio-molecules. It appears in almost every eukaryotic cell and many bacteria. Although the different species differ in the number of subunits, the functional differences are merely marginal. CcO is the terminal link in the electron transfer pathway of the mitochondrial respiratory chain. Electrons transferred to the catalytic center of the enzyme conduce to the reduction of molecular oxygen to water. Oxygen reduction is coupled to the pumping of protons into the inter-membrane space and hence generates a difference in electrochemical potential of protons across the inner mitochondrial membrane. This potential difference drives the synthesis of adenosine triphosphate (ATP), which is the universal energy carrier within all biological cells. rnrnThe goal of the present work is to contribute to a better understanding of the functional mechanism of CcO by using time-resolved surface enhanced resonance Raman spectroscopy (TR-SERRS). Despite intensive research effort within the last decades, the functional mechanism of CcO is still subject to controversial discussions. It was the primary goal of this dissertation to initiate electron transfer to the redox centers CuA, heme a, heme a3 and CuB electrochemically and to observe the corresponding redox transitions in-situ with a focus on the two heme structures by using SERRS. A measuring cell was developed, which allowed combination of electrochemical excitation with Raman spectroscopy for the purpose of performing the accordant measurements. Cytochrome c was used as a benchmark system to test the new measuring cell and to prove the feasibility of appropriate Raman measurements. In contrast to CcO the heme protein cc contains only a single heme structure. Nevertheless, characteristic Raman bands of the hemes can be observed for both proteins.rnrnIn order to investigate CcO it was immobilized on top of a silver substrate and embedded into an artificial membrane. The catalytic activity of CcO and therefore the complete functional capability of the enzyme within the biomimetic membrane architecture was verified using cyclic voltammetry. Raman spectroscopy was performed using a special nano-structured silver surface, which was developed within the scope of the present work. This new substrate combined two fundamental properties. It facilitated the formation of a protein tethered bilayer lipid membrane (ptBLM) and it allowed obtaining Raman spectra with sufficient high signal-to-noise ratios.rnSpectro-electrochemical investigations showed that at open circuit potential the enzyme exists in a mixed-valence state, with heme a and and heme a3 in the reduced and oxidized state, respectively. This was considered as an intermediate state between the non-activated and the fully activated state of CcO. Time-resolved SERRS measurements revealed that a hampered electron transfer to the redox center heme a3 characterizes this intermediate state.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gleno-humeral joint (GHJ) is the most mobile joint of the human body. This is related to theincongr uence between the large humeral head articulating with the much smaller glenoid (ratio 3:1). The GHJ laxity is the ability of the humeral head to be passively translated on the glenoid fossa and, when physiological, it guarantees the normal range of motion of the joint. Three-dimensional GHJ linear displacements have been measured, both in vivo and in vitro by means of different instrumental techniques. In vivo gleno-humeral displacements have been assessed by means of stereophotogrammetry, electromagnetic tracking sensors, and bio-imaging techniques. Both stereophotogrammetric systems and electromagnetic tracking devices, due to the deformation of the soft tissues surrounding the bones, are not capable to accurately assess small displacements, such as gleno-humeral joint translations. The bio-imaging techniques can ensure for an accurate joint kinematic (linear and angular displacement) description, but, due to the radiation exposure, most of these techniques, such as computer tomography or fluoroscopy, are invasive for patients. Among the bioimaging techniques, an alternative which could provide an acceptable level of accuracy and that is innocuous for patients is represented by magnetic resonance imaging (MRI). Unfortunately, only few studies have been conducted for three-dimensional analysis and very limited data is available in situations where preset loads are being applied. The general aim of this doctoral thesis is to develop a non-invasive methodology based on open-MRI for in-vivo evaluation of the gleno-humeral translation components in healthy subjects under the application of external loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nel presente lavoro di tesi magistrale sono stati depositati e caratterizzati sottili film di ossido di alluminio, Al2O3, (di spessore compreso tra 3-30 nm) su un substrato di FZ-Si drogato p. La deposizione è avvenuta mediante plasma ALD (Atomic Layer Depostion). La tecnica spettroscopica EPR (Electron Paramagnetic Resonance) è stata utilizzata per studiare l’interfaccia Si/Al2O3 con lo scopo di scoprire l’origine della formazione di densità di carica negativa Qf all’interfaccia: tale carica negativa induce una passivazione per effetto di campo ed è quindi la ragione per cui il dielettrico Al2O3 risulta essere un ottimo materiale passivante. Si è deciso di variare alcuni parametri, come lo spessore dello strato di Al2O3, lo spessore dello strato intermedio di ossido di silicio, depositato mediante ossidazione termica (dry thermal oxidation), e la superficie del substrato di silicio. Sono stati realizzati cinque differenti gruppi di campioni: per ciascuno di essi sono state impiegate varie tecniche di caratterizzazione, come la QSSPC (Quasi Steady State Photoconuctance) e la tecnica di spettroscopia ottica SE (spettroscopic ellipsometry). Per ogni gruppo sono stati riportati gli spettri EPR ottenuti ed i rispettivi fit, da cui è stato possibile risalire ai fattori giromagnetici di spin g, riportati in tabelle con le loro possibili attribuzioni. E’ stato dimostrato che la presenza di uno strato di ossido di silicio tra il substrato di silicio e lo strato di ossido di alluminio risulta essere fondamentale per la formazione di densità di carica negativa all’interfaccia: aumentando lo spessore dello strato di SiOx (nel range 1-30 nm) si assiste ad una diminuzione di carica negativa Qf. Analizzando gli spettri EPR, è stato possibile concludere che all’interfaccia Si/Al2O3 sono presenti difetti caratteristici dell’interfaccia Si/SiOx. Le nostre osservazioni, dunque, sono coerenti con la formazione di uno strato di ossido di silicio tra Si e Al2O3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the scientific achievement of the last decades in the astrophysical and cosmological fields, the majority of the Universe energy content is still unknown. A potential solution to the “missing mass problem” is the existence of dark matter in the form of WIMPs. Due to the very small cross section for WIMP-nuleon interactions, the number of expected events is very limited (about 1 ev/tonne/year), thus requiring detectors with large target mass and low background level. The aim of the XENON1T experiment, the first tonne-scale LXe based detector, is to be sensitive to WIMP-nucleon cross section as low as 10^-47 cm^2. To investigate the possibility of such a detector to reach its goal, Monte Carlo simulations are mandatory to estimate the background. To this aim, the GEANT4 toolkit has been used to implement the detector geometry and to simulate the decays from the various background sources: electromagnetic and nuclear. From the analysis of the simulations, the level of background has been found totally acceptable for the experiment purposes: about 1 background event in a 2 tonne-years exposure. Indeed, using the Maximum Gap method, the XENON1T sensitivity has been evaluated and the minimum for the WIMP-nucleon cross sections has been found at 1.87 x 10^-47 cm^2, at 90% CL, for a WIMP mass of 45 GeV/c^2. The results have been independently cross checked by using the Likelihood Ratio method that confirmed such results with an agreement within less than a factor two. Such a result is completely acceptable considering the intrinsic differences between the two statistical methods. Thus, in the PhD thesis it has been proven that the XENON1T detector will be able to reach the designed sensitivity, thus lowering the limits on the WIMP-nucleon cross section by about 2 orders of magnitude with respect to the current experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The last half-century has seen a continuing population and consumption growth, increasing the competition for land, water and energy. The solution can be found in the new sustainability theories, such as the industrial symbiosis and the zero waste objective. Reducing, reusing and recycling are challenges that the whole world have to consider. This is especially important for organic waste, whose reusing gives interesting results in terms of energy release. Before reusing, organic waste needs a deeper characterization. The non-destructive and non-invasive features of both Nuclear Magnetic Resonance (NMR) relaxometry and imaging (MRI) make them optimal candidates to reach such characterization. In this research, NMR techniques demonstrated to be innovative technologies, but an important work on the hardware and software of the NMR LAGIRN laboratory was initially done, creating new experimental procedures to analyse organic waste samples. The first results came from soil-organic matter interactions. Remediated soils properties were described in function of the organic carbon content, proving the importance of limiting the addition of further organic matter to not inhibit soil processes as nutrients transport. Moreover NMR relaxation times and the signal amplitude of a compost sample, over time, showed that the organic matter degradation of compost is a complex process that involves a number of degradation kinetics, as a function of the mix of waste. Local degradation processes were studied with enhanced quantitative relaxation technique that combines NMR and MRI. The development of this research has finally led to the study of waste before it becomes waste. Since a lot of food is lost when it is still edible, new NMR experiments studied the efficiency of conservation and valorisation processes: apple dehydration, meat preservation and bio-oils production. All these results proved the readiness of NMR for quality controls on a huge kind of organic residues and waste.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major challenge in imaging is the detection of small amounts of molecules of interest. In the case of magnetic resonance imaging (MRI) their signals are typically concealed by the large background signal of e.g. the tissue of the body. This problem can be tackled by hyperpolarization which increases the NMR signals up to several orders of magnitude. However, this strategy is limited for 1H, the most widely used nucleus in NMR andrnMRI, because the enormous number of protons in the body screen the small amount of hyperpolarized ones.Here, I describe a method giving rise to high 1H MRI contrast for hyperpolarized molecules against a large background signal. The contrast is based on the J-coupling induced rephasing of the NMR signal of molecules hyperpolarized via parahydrogen induce polarization (PHIP) and it can easily be implemented in common pulse sequences.rnrnHyperpolarization methods typically require expensive technical equipment (e.g. lasers or microwaves) and most techniques work only in batch mode, thus the limited lifetime of the hyperpolarization is limiting its applications. Therefore, the second part of my thesis deals with the simple and efficient generation of an hyperpolarization.These two achievements open up alternative opportunities to use the standard MRI nucleus 1H for e.g. metabolic imaging in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Der Haupt-Lichtsammenkomplex II (LHCII) höherer Pflanzen ist das häufigsternMembranprotein der Welt und in die chloroplastidäre Thylakoidmembran integriert. DerrnLHCII kann als Modellsystem genutzt werden, um die Funktionsweise vonrnMembranproteinen besser zu verstehen, da 96 % seiner Struktur kristallografisch aufgelöstrnist und er in rekombinanter Form in vitro rückgefaltet werden kann. Hierbei entsteht einrnvoll funktionaler Protein-Pigment.Komplex, der nahezu identisch mit der in vivo Varianternist.rnElektronenparamagnetischen Resonanz (EPR) Spektroskopie ist eine hoch sensitive undrnideal geeignete Methode, um die Strukturdynamik von Proteinen zu untersuchen. Hierzurnist eine ortsspezifische Markierung mit Spinsonden notwendig, die kovalent an Cysteinernbinden. Möglich wird dies, indem sorgfältig ausgewählte Aminosäuren gegen Cysteinerngetauscht werden, ohne dass die Funktionsweise des LHCII beeinträchtigt wird.rnIm Rahmen dieser Arbeit wurden die Stabilität des verwendeten Spinmarkers und diernProbenqualität verbessert, indem alle Schritte der Probenpräparation untersucht wurden.rnMithilfe dieser Erkenntnisse konnte sowohl die Gefahr einer Proteinaggregation als auchrnein Verlust des EPR Signals deutlich vermindert werden. In Kombination mit derrngleichzeitigen Etablierung des Q-Band EPR können nun deutlich geringer konzentrierternProben zuverlässig vermessen werden. Darüber hinaus wurde eine reproduzierbarernMethode entwickelt, um heterogene Trimere herzustellen. Diese bestehen aus einemrndoppelt markierten Monomer und zwei unmarkierten Monomeren und erlauben es, diernkristallografisch unvollständig aufgelöste N-terminale Domäne im monomeren undrntrimeren Assemblierungsgrad zu untersuchen. Die Ergebnisse konnten einerseits diernVermutung bestätigen, dass diese Domäne im Vergleich zum starren Proteinkern sehrrnflexibel ist und andererseits, dass sie in Monomeren noch mobiler ist als in Trimeren.rnZudem wurde die lumenale Schleifenregion bei unterschiedlichen pH Werten undrnvariierender Pigmentzusammensetzung untersucht, da dieser Bereich sehr kontroversrndiskutiert wird. Die Messergebnisse offenbarten, dass diese Region starre und flexiblerernSektionen aufweist. Während der pH Wert keinen Einfluss auf die Konformation hatte,rnzeigte sich, dass die Abwesenheit von Neoxanthin zu einer Änderung der Konformationrnführt. Weiterführende Analysen der strukturellen Dynamik des LHCII in einerrnLipidmembran konnten hingegen nicht durchgeführt werden, da dies eine gerichteternInsertion des rückgefalteten Proteins in Liposomen erfordert, was trotz intensiverrnVersuche nicht zum Erfolg führte.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In questa tesi si studiano alcune proprietà fondamentali delle funzioni Zeta e L associate ad una curva ellittica. In particolare, si dimostra la razionalità della funzione Zeta e l'ipotesi di Riemann per due famiglie specifiche di curve ellittiche. Si studia poi il problema dell'esistenza di un prolungamento analitico al piano complesso della funzione L di una curva ellittica con moltiplicazione complessa, attraverso l'analisi diretta di due casi particolari.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Subthreshold resonance is a characteristic membrane property of different neuronal classes, is critically involved in the generation of network oscillations, and tunes the integration of synaptic inputs to particular frequency ranges. In order to investigate whether resonance properties of distinct neuronal populations in the immature neocortex contribute to these network oscillations, I performed whole-cell patch-clamp recordings from visually identified neurons in tangential and coronal neocortical slices from postnatal day (P) P0-P7 C57Bl/6 and P6-P13 GAD67-GFP knock-in mice. Subthreshold resonance was analyzed by sinusoidal current injection of varying frequency. All Cajal-Retzius cells showed subthreshold resonance with an average frequency of 2.6 ± 0.1 Hz (n=60), which was massively reduced by ZD7288, a blocker of hyperpolarization-activated cation currents. About 65.6% (n=61) of the supragranular pyramidal neurons showed subthreshold resonance with an average frequency of 1.4 ± 0.1 Hz (n=40). Application of 1 mM Ni2+ suppressed subthreshold resonance, suggesting that low-threshold Ca2+ currents contribute to resonance in these neurons. About 63.6% (n=77) of the layer V pyramidal neurons showed subthreshold resonance with an average frequency of 1.4 ± 0.2 Hz (n=49), which was abolished by ZD7288. Only 44.1% (n=59) of the subplate neurons showed subthreshold resonance with an average frequency of 1.3 ± 0.2 Hz (n=26) and a small resonance strength. Finally, 50% of the investigated GABAergic interneurons showed subthreshold resonance with an average frequency of 2.0 ± 0.2 Hz (n=42). Membrane hyperpolarization to –86 mV attenuated the frequency and strength of subthreshold resonance. Subthreshold resonance was virtually abolished in the presence of 1 mM Ni2+, suggesting that t-type Ca2+ currents are critically involved in the generation of resonance, while ZD7288 had no effect. Application of 0.4 µM TTX suppressed subthreshold resonance at depolarized, but not hyperpolarized membrane potential, suggesting that persistent Na+ current contribute to the amplification of membrane resonance. rnIn summary, these results demonstrate that all investigated neuronal subpopulations reveal resonance behavior, with either hyperpolarization-activated cation or low-threshold Ca2+ currents contributing to the subthreshold resonance. GABAergic interneurons also express subthreshold resonance at low frequencies, with t-type Ca2+ and persistent Na+ currents underlying the generation of membrane resonance. The membrane resonance of immature neurons may contribute to the generation of slow oscillatory activity pattern in the immature neocortex and enhance the temporal precision of synaptic integration in developing cortical neurons.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde ein neuartiger Experimentaufbau -- das γ3 Experiment -- zur Messung von photoneninduzierten Kern-Dipolanregungen in stabilen Isotopen konzipiert und an der High Intensity γ-Ray Source (HIγS) an der Duke University installiert.rnDie hohe Energieauflösung und die hohe Nachweiseffizienz des Detektoraufbaus, welcher aus einer Kombination von LaBr Szintillatoren und hochreinen Germanium-Detektoren besteht, erlaubt erstmals die effiziente Messung von γ-γ-Koinzidenzen in Verbindung mit der Methode der Kernresonanzfluoreszenz.rnDiese Methode eröffnet den Zugang zum Zerfallsverhalten der angeregten Dipolzustände als zusätzlicher Observablen, die ein detaillierteres Verständnis der zugrunde liegenden Struktur dieser Anregungen ermöglicht.rnDer Detektoraufbau wurde bereits erfolgreich im Rahmen von zwei Experimentkampagnen in 2012 und 2013 für die Untersuchung von 13 verschiedenen Isotopen verwendet. Im Fokus dieser Arbeit stand die Analyse der Pygmy-Dipolresonanz (PDR) im Kern 140Ce im Energiebereich von 5,2 MeV bis 8,3 MeV basierend auf den mit dem γ3 Experimentaufbau gemessenen Daten. Insbesondere das Zerfallsverhalten der Zustände, die an der PDR beteiligt sind, wurde untersucht. Der Experimentaufbau, die Details der Analyse sowie die Resultate werden in der vorliegenden Arbeit präsentiert. Desweiteren erlaubt ein Vergleich der Ergebnisse mit theoretischen Rechnungen im quasi-particle phonon model (QPM) eine Interpretation des beobachteten Zerfallsverhaltens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Die Kontroverse über den Glasübergang im Nanometerbereich, z. B. die Glas¬über¬gangs-temperatur Tg von dünnen Polymerfilmen, ist nicht vollständig abgeschlossen. Das dynamische Verhalten auf der Nanoskala ist stark von den einschränkenden Bedingungen abhängig, die auf die Probe wirken. Dünne Polymerfilme sind ideale Systeme um die Dynamik von Polymerketten unter der Einwirkung von Randbedingungen zu untersuchen, wie ich sie in dieser Arbeit variiert habe, um Einblick in dieses Problem zu erhalten.rnrnResonanzverstärkte dynamische Lichtstreuung ist eine Methode, frei von z.B. Fluoreszenzmarkern, die genutzt werden kann um in dünnen Polymerfilmen dynamische Phänomene