893 resultados para space optical communications


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Urban wayfinding technology offers many possibilities by which older people and mobility-impaired users can overcome the barriers encountered on every-day journeys in the built environment. Previous work has highlighted the extent to which personal mobility and independence are significant determinants of the quality of life amongst both elderly and visually impaired groups. The paper outlines the development of the auditory location finder (ALF), which is a beacon-based local information system designed to enhance the wayfinding activities of these, and potentially other, user-groups in the community. The proposed system provides the user with an audio message, which is obtained on request via a small portable hand unit. The messages inform the user of their whereabouts and give information about the area that they are currently in. The development of the device involves issues such as message content and structure, route choice, orientation, landmarks, clues and the extent of user reliance on technology. Preliminary trials have been carried out in a UK city and have obtained initial user feedback to help underpin the technological development of the device and its potential application. The paper concludes by outlining the importance of new urban technology and the way in which such local information systems can potentially contribute to overcoming particular patterns of exclusion experienced by mobility-impaired groups, such as the visually impaired

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Social networks are a recent phenomenon of communication, with a high prevalence of young users. This concept serves as a motto for a multidisciplinary project, which aims to create a simple communication network, using light as the transmission medium. Mixed team, composed by students from secondary and higher education schools, are partners on the development of an optical transceiver. A LED lamp array and a small photodiode are the optical transmitter and receiver, respectively. Using several transceivers aligned with each other, this con guration creates a ring communication network, enabling the exchange of messages between users. Through this project, some concepts addressed in physics classes from secondary schools (e.g. photoelectric phenomena and the properties of light) are experimentally veri ed and used to communicate, in a classroom or a laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A compiled set of in situ data is important to evaluate the quality of ocean-colour satellite-data records. Here we describe the data compiled for the validation of the ocean-colour products from the ESA Ocean Colour Climate Change Initiative (OC-CCI). The data were acquired from several sources (MOBY, BOUSSOLE, AERONET-OC, SeaBASS, NOMAD, MERMAID, AMT, ICES, HOT, GeP&CO), span between 1997 and 2012, and have a global distribution. Observations of the following variables were compiled: spectral remote-sensing reflectances, concentrations of chlorophyll a, spectral inherent optical properties and spectral diffuse attenuation coefficients. The data were from multi-project archives acquired via the open internet services or from individual projects, acquired directly from data providers. Methodologies were implemented for homogenisation, quality control and merging of all data. No changes were made to the original data, other than averaging of observations that were close in time and space, elimination of some points after quality control and conversion to a standard format. The final result is a merged table designed for validation of satellite-derived ocean-colour products and available in text format. Metadata of each in situ measurement (original source, cruise or experiment, principal investigator) were preserved throughout the work and made available in the final table. Using all the data in a validation exercise increases the number of matchups and enhances the representativeness of different marine regimes. By making available the metadata, it is also possible to analyse each set of data separately. The compiled data are available at doi: 10.1594/PANGAEA.854832 (Valente et al., 2015).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents an investigation on endoscopic optical coherence tomography (OCT). As a noninvasive imaging modality, OCT emerges as an increasingly important diagnostic tool for many clinical applications. Despite of many of its merits, such as high resolution and depth resolvability, a major limitation is the relatively shallow penetration depth in tissue (about 2∼3 mm). This is mainly due to tissue scattering and absorption. To overcome this limitation, people have been developing many different endoscopic OCT systems. By utilizing a minimally invasive endoscope, the OCT probing beam can be brought to the close vicinity of the tissue of interest and bypass the scattering of intervening tissues so that it can collect the reflected light signal from desired depth and provide a clear image representing the physiological structure of the region, which can not be disclosed by traditional OCT. In this thesis, three endoscope designs have been studied. While they rely on vastly different principles, they all converge to solve this long-standing problem.

A hand-held endoscope with manual scanning is first explored. When a user is holding a hand- held endoscope to examine samples, the movement of the device provides a natural scanning. We proposed and implemented an optical tracking system to estimate and record the trajectory of the device. By registering the OCT axial scan with the spatial information obtained from the tracking system, one can use this system to simply ‘paint’ a desired volume and get any arbitrary scanning pattern by manually waving the endoscope over the region of interest. The accuracy of the tracking system was measured to be about 10 microns, which is comparable to the lateral resolution of most OCT system. Targeted phantom sample and biological samples were manually scanned and the reconstructed images verified the method.

Next, we investigated a mechanical way to steer the beam in an OCT endoscope, which is termed as Paired-angle-rotation scanning (PARS). This concept was proposed by my colleague and we further developed this technology by enhancing the longevity of the device, reducing the diameter of the probe, and shrinking down the form factor of the hand-piece. Several families of probes have been designed and fabricated with various optical performances. They have been applied to different applications, including the collector channel examination for glaucoma stent implantation, and vitreous remnant detection during live animal vitrectomy.

Lastly a novel non-moving scanning method has been devised. This approach is based on the EO effect of a KTN crystal. With Ohmic contact of the electrodes, the KTN crystal can exhibit a special mode of EO effect, termed as space-charge-controlled electro-optic effect, where the carrier electron will be injected into the material via the Ohmic contact. By applying a high voltage across the material, a linear phase profile can be built under this mode, which in turn deflects the light beam passing through. We constructed a relay telescope to adapt the KTN deflector into a bench top OCT scanning system. One of major technical challenges for this system is the strong chromatic dispersion of KTN crystal within the wavelength band of OCT system. We investigated its impact on the acquired OCT images and proposed a new approach to estimate and compensate the actual dispersion. Comparing with traditional methods, the new method is more computational efficient and accurate. Some biological samples were scanned by this KTN based system. The acquired images justified the feasibility of the usage of this system into a endoscopy setting. My research above all aims to provide solutions to implement an OCT endoscope. As technology evolves from manual, to mechanical, and to electrical approaches, different solutions are presented. Since all have their own advantages and disadvantages, one has to determine the actual requirements and select the best fit for a specific application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Data traffic in cellular networks has dramatically increased in recent years as the emergence of various new wireless applications, which imposes an immediate requirement for large network capacity. Although many efforts have been made to enhance wireless channel capacity, they are far from solving the network capacity enhancement problem. Device-to-Device (D2D) communication is recently proposed as a promising technique to increase network capacity. However, most existing work on D2D communications focuses on optimizing throughput or energy efficiency, without considering economic issues. In this paper, we propose a truthful double auction for D2D communications (TAD) in multi-cell cellular networks for trading resources in frequencytime domain, where cellular users with D2D communication capability act as sellers, and other users waiting to access the network act as buyers. Both intra-cell and inter-cell D2D sellers are accommodated in TAD while the competitive space in each cell is extensively exploited to achieve a high auction efficiency. With a sophisticated seller-buyer matching, winner determination and pricing, TAD guarantees individual rationality, budget balance, and truthfulness. Furthermore, we extend our TAD design to handle a more general case that each seller and buyer ask/bid multiple resource units. Extensive simulation results show that TAD can achieve truthfulness as well as high performance in terms of seller/buyer sanctification ratio, auctioneer profit and network throughput.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose weakly-constrained stream and block codes with tunable pattern-dependent statistics and demonstrate that the block code capacity at large block sizes is close to the the prediction obtained from a simple Markov model published earlier. We demonstrate the feasibility of the code by presenting original encoding and decoding algorithms with a complexity log-linear in the block size and with modest table memory requirements. We also show that when such codes are used for mitigation of patterning effects in optical fibre communications, a gain of about 0.5dB is possible under realistic conditions, at the expense of small redundancy (≈10%). © 2010 IEEE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate cascaded 100-Gb/s sub-channel add/drop from a 1-Tb/s multi-band OFDM super-channel having 2-GHz inter-sub-channel guard-bands within a recirculating loop via a hierarchical ROADM using high-resolution filters, showcasing 1000-km transmission reach and five ROADM node passages for the add/drop sub-channel when hybrid Raman-EDFA is implemented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

SpicA FAR infrared Instrument, SAFARI, is one of the instruments planned for the SPICA mission. The SPICA mission is the next great leap forward in space-based far-infrared astronomy and will study the evolution of galaxies, stars and planetary systems. SPICA will utilize a deeply cooled 2.5m-class telescope, provided by European industry, to realize zodiacal background limited performance, and high spatial resolution. The instrument SAFARI is a cryogenic grating-based point source spectrometer working in the wavelength domain 34 to 230 μm, providing spectral resolving power from 300 to at least 2000. The instrument shall provide low and high resolution spectroscopy in four spectral bands. Low Resolution mode is the native instrument mode, while the high Resolution mode is achieved by means of a Martin-Pupplet interferometer. The optical system is all-reflective and consists of three main modules; an input optics module, followed by the Band and Mode Distributing Optics and the grating Modules. The instrument utilizes Nyquist sampled filled linear arrays of very sensitive TES detectors. The work presented in this paper describes the optical design architecture and design concept compatible with the current instrument performance and volume design drivers.