945 resultados para setup carryover


Relevância:

10.00% 10.00%

Publicador:

Resumo:

in the everyday clinical practice. Having this in mind, the choice of a simple setup would not be enough because, even if the setup is quick and simple, the instrumental assessment would still be in addition to the daily routine. The will to overcome this limit has led to the idea of instrumenting already existing and widely used functional tests. In this way the sensor based assessment becomes an integral part of the clinical assessment. Reliable and validated signal processing methods have been successfully implemented in Personal Health Systems based on smartphone technology. At the end of this research project there is evidence that such solution can really and easily used in clinical practice in both supervised and unsupervised settings. Smartphone based solution, together or in place of dedicated wearable sensing units, can truly become a pervasive and low-cost means for providing suitable testing solutions for quantitative movement analysis with a clear clinical value, ultimately providing enhanced balance and mobility support to an aging population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Untersuchung von halbleitenden Materialien auf der Basis von organischen Molekülen stellt ein Gebiet der angewandten Forschung an der Schwelle zur industriellen Nutzung dar. Geringes Gewicht und hohe mechanische Flexibilität ermöglichen völlig neue Produkte, die mit anorganischen Halbleitern nicht zu realisieren sind. Die Herstellung von Bauteilen wie Transistoren, Solarzellen oder Leuchtdioden aus organischen Materialien ist ein komplexes Gebiet, das einer Vielzahl von unterschiedlichen Optimierungen bedarf, um eine konkurrenzfähige Leistung zu erreichen. Die synthetische organische Chemie bietet vielfältige Möglichkeiten, mit maßgeschneiderten Lösungen zum Optimierungsprozess beizutragen. Zum einen können neue aktive Materialien hergestellt werden mit besserer Leistung und leichterer Verarbeitbarkeit. Zum anderen sind Substanzen zugänglich, die z.B. bei der Ladungsträgerinjektion hilfreich sein können.rnIn dieser Arbeit wurde an beiden dieser Fronten gearbeitet. Dabei lag die Entwicklungsstrategie darin, ausgedehnte π-konjugierte Moleküle herzustellen, die entweder besonders elektronenarme Akzeptoren oder elektronenreiche Donoren darstellen. Die genaue Kontrolle der elektronischen Niveaus stellt einen wichtigen Bestandteil dar, um niedrige elektrische Kontaktbarrieren zu Metallen zu erreichen und ausreichend stabile Materialien zu erreichen.rnDer erste Fokus der Arbeiten lag in der Funktionalisierung von Coronen. Dieser PAH stellt einen guten Kompromiss bezüglich seiner Größe dar: Er ist groß genug, um Diffusion in andere Schichten von Bauteilen zu vermeiden, aber nicht zu groß, um Verarbeitung durch Vakuumsublimation zu ermöglichen. Bislang sind praktisch keine Coronen-Derivate in der Literatur beschrieben, weshalb eine neue Synthese entwickelt werden musste, die die Einführung starker Donor- und Akzeptorfunktionalitäten erlaubt. Die photochemische Cyclodehydrierung von substituierten [2.2.2]paracyclophan-trienen stellte sich als hervorragende Möglichkeit heraus, dies zu bewerkstelligen. Es wurde eine Reihe von methoxy-substitutierten Coronenen mit unterschiedlicher Symmetrie hergestellt. Mittels optischer Spektroskopie konnte gezeigt werden, dass Methoxygruppen wenig Einfluss auf die elektronischen Eigenschaften von Coronen haben. Unter Spaltung der Methylether und anschließender Oxidation allerdings sind Coronenketone zugänglich, welche bis zu drei α-Diketongruppen besitzen. Diese Moleküle sind enorm starke Akzeptoren, was durch Cyclovoltammetrie und Vergleich zu anderen Akzeptoren eindrucksvoll gezeigt werden konnte. Die Sublimation dieses Akzeptors auf die Oberfläche von Metallen zeigt einen dramatischen Einfluss auf die Austrittsarbeit dieses Metalls, was zur Herstellung eines ohmschen Kontakts zu organischen Halbleitern von außerordentlichem Nutzen ist. rnDen zweiten Teil der Arbeit bilden Benzodithiophen enthaltende Polymere, die für den Einsatz als aktive Komponente in elektronischen Bauteilen entwickelt wurden. Nach systematischer Strukturoptimierung wurde ein Polymer enthalten, welches in einem Feldeffekt-Transistor auf Standard-Silizium-Substraten Ladungsträger-Mobilitäten über 0,1 cm2/Vs erreicht mit großer Reproduzierbarkeit und ausgezeichneter Transistor-Charakteristik. Es konnte gezeigt werden, dass die durch die Monomergeometrie erzeugte Kurvung des Polymers zu einem optimalen Kompromiss aus Löslichkeit und effektiver Packung darstellt. Auf für industrielle Anwendungen besonders interessanten polymer-basierten Substraten wurde eine noch erheblich bessere Leistung gezeigt. Auf einem PET-Substrat wurden Feldeffekt-Mobilitäten von 0,5 cm2/Vs gemessen mit überzeugenden Reproduzierbarkeit und Stabilität.rnDamit konnte in der Arbeit ein bedeutender Beitrag zur Weiterentwicklung von Materialien für den Einsatz in elektronischen Bauteilen geleistet werden. Die Substanzen versprechen noch erhebliches Potenzial nach intensiver Optimierung und wurden deshalb zum Patent angemeldet.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde ein flugzeuggetragenes Laserablations-Einzelpartikel-Massenspektrometer von Grund auf entworfen, gebaut, charakterisiert und auf verschiedenen Feldmesskampagnen eingesetzt. Das ALABAMA (Aircraft-based Laser ABlation Aerosol MAss Spectrometer) ist in der Lage die chemische Zusammensetzung und Größe von einzelnen Aerosolpartikeln im submikrometer-Bereich (135 – 900 nm) zu untersuchen.rnNach dem Fokussieren in einer aerodynamischen Linse wird dafür zunächst derrnaerodynamische Durchmesser der einzelnen Partikel mit Hilfe einer Flugzeitmessung zwischen zwei Dauerstrichlasern bestimmt. Anschließend werden die zuvor detektierten und klassifizierten Partikel durch einen gezielten Laserpuls einzeln verdampft und ionisiert. Die Ionen werden in einem bipolaren Flugzeit-Massenspektrometer entsprechend ihrem Masse zu- Ladungs Verhältnisses getrennt und detektiert. Die entstehenden Massenspektren bieten einen detaillierten Einblick in die chemische Struktur der einzelnen Partikel.rnDas gesamte Instrument wurde so konzipiert, dass es auf dem neuen Höhenforschungsflugzeug HALO und anderen mobilen Plattformen eingesetzt werden kann. Um dies zu ermöglichen wurden alle Komponenten in einem Rahmen mit weniger als 0.45 m³ Volumen untergebracht. Das gesamte Instrument inklusive Rahmen wiegt weniger als 150 kg und erfüllt die strengen sicherheitsvorschriften für den Betrieb an Bord von Forschungsflugzeugen. Damit ist ALABAMA das kleinste und leichteste Instrument seiner Art.rnNach dem Aufbau wurden die Eigenschaften und Grenzen aller Komponenten detailliert im Labor und auf Messkampagnen charakterisiert. Dafür wurden zunächst die Eigenschaften des Partikelstrahls, wie beispielsweise Strahlbreite und –divergenz, ausführlich untersucht. Die Ergebnisse waren wichtig, um die späteren Messungen der Detektions- und Ablationseffizienz zu validieren.rnBei den anschließenden Effizienzmessungen wurde gezeigt, dass abhängig von ihrer Größe und Beschaffenheit, bis zu 86 % der vorhandenen Aerosolpartikel erfolgreich detektiert und größenklassifiziert werden. Bis zu 99.5 % der detektierten Partikel konnten ionisiert und somit chemisch untersucht werden. Diese sehr hohen Effizienzen sind insbesondere für Messungen in großer Höhe entscheidend, da dort zum Teil nur sehr geringe Partikelkonzentrationen vorliegen.rnDas bipolare Massenspektrometer erzielt durchschnittliche Massenauflösungen von bis zu R=331. Während Labor- und Feldmessungen konnten dadurch Elemente wie Au, Rb, Co, Ni, Si, Ti und Pb eindeutig anhand ihres Isotopenmusters zugeordnet werden.rnErste Messungen an Bord eines ATR-42 Forschungsflugzeuges während der MEGAPOLI Kampagne in Paris ergaben einen umfassenden Datensatz von Aerosolpartikeln innerhalb der planetaren Grenzschicht. Das ALABAMA konnte unter harten physischen Bedingungen (Temperaturen > 40°C, Beschleunigungen +/- 2 g) verlässlich und präzise betrieben werden. Anhand von charakteristischen Signalen in den Massenspektren konnten die Partikel zuverlässig in 8 chemische Klassen unterteilt werden. Einzelne Klassen konnten dabei bestimmten Quellen zugeordnet werden. So ließen sich beispielsweise Partikel mit starkerrnNatrium- und Kaliumsignatur eindeutig auf die Verbrennung von Biomasse zurückführen.rnALABAMA ist damit ein wertvolles Instrument um Partikel in-situ zu charakterisieren und somit verschiedenste wissenschaftliche Fragestellungen, insbesondere im Bereich der Atmosphärenforschung, zu untersuchen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

“Plasmon” is a synonym for collective oscillations of the conduction electrons in a metal nanoparticle (excited by an incoming light wave), which cause strong optical responses like efficient light scattering. The scattering cross-section with respect to the light wavelength depends not only on material, size and shape of the nanoparticle, but also on the refractive index of the embedding medium. For this reason, plasmonic nanoparticles are interesting candidates for sensing applications. Here, two novel setups for rapid spectral investigations of single nanoparticles and different sensing experiments are presented.rnrnPrecisely, the novel setups are based on an optical microscope operated in darkfield modus. For the fast single particle spectroscopy (fastSPS) setup, the entrance pinhole of a coupled spectrometer is replaced by a liquid crystal device (LCD) acting as spatially addressable electronic shutter. This improvement allows the automatic and continuous investigation of several particles in parallel for the first time. The second novel setup (RotPOL) usesrna rotating wedge-shaped polarizer and encodes the full polarization information of each particle within one image, which reveals the symmetry of the particles and their plasmon modes. Both setups are used to observe nanoparticle growth in situ on a single-particle level to extract quantitative data on nanoparticle growth.rnrnUsing the fastSPS setup, I investigate the membrane coating of gold nanorods in aqueous solution and show unequivocally the subsequent detection of protein binding to the membrane. This binding process leads to a spectral shift of the particles resonance due to the higher refractive index of the protein compared to water. Hence, the nanosized addressable sensor platform allows for local analysis of protein interactions with biological membranes as a function of the lateral composition of phase separated membranes.rnrnThe sensitivity on changes in the environmental refractive index depends on the particles’ aspect ratio. On the basis of simulations and experiments, I could present the existence of an optimal aspect ratio range between 3 and 4 for gold nanorods for sensing applications. A further sensitivity increase can only be reached by chemical modifications of the gold nanorods. This can be achieved by synthesizing an additional porous gold cage around the nanorods, resulting in a plasmon sensitivity raise of up to 50 % for those “nanorattles” compared to gold nanorods with the same resonance wavelength. Another possibility isrnto coat the gold nanorods with a thin silver shell. This reduces the single particle’s resonance spectral linewidth about 30 %, which enlarges the resolution of the observable shift. rnrnThis silver coating evokes the interesting effect of reducing the ensemble plasmon linewidth by changing the relation connecting particle shape and plasmon resonance wavelength. This change, I term plasmonic focusing, leads to less variation of resonance wavelengths for the same particle size distribution, which I show experimentally and theoretically.rnrnIn a system of two coupled nanoparticles, the plasmon modes of the transversal and longitudinal axis depend on the refractive index of the environmental solution, but only the latter one is influenced by the interparticle distance. I show that monitoring both modes provides a self-calibrating system, where interparticle distance variations and changes of the environmental refractive index can be determined with high precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of guided ultrasonic waves (GUW) has increased considerably in the fields of non-destructive (NDE) testing and structural health monitoring (SHM) due to their ability to perform long range inspections, to probe hidden areas as well as to provide a complete monitoring of the entire waveguide. Guided waves can be fully exploited only once their dispersive properties are known for the given waveguide. In this context, well stated analytical and numerical methods are represented by the Matrix family methods and the Semi Analytical Finite Element (SAFE) methods. However, while the former are limited to simple geometries of finite or infinite extent, the latter can model arbitrary cross-section waveguides of finite domain only. This thesis is aimed at developing three different numerical methods for modelling wave propagation in complex translational invariant systems. First, a classical SAFE formulation for viscoelastic waveguides is extended to account for a three dimensional translational invariant static prestress state. The effect of prestress, residual stress and applied loads on the dispersion properties of the guided waves is shown. Next, a two-and-a-half Boundary Element Method (2.5D BEM) for the dispersion analysis of damped guided waves in waveguides and cavities of arbitrary cross-section is proposed. The attenuation dispersive spectrum due to material damping and geometrical spreading of cavities with arbitrary shape is shown for the first time. Finally, a coupled SAFE-2.5D BEM framework is developed to study the dispersion characteristics of waves in viscoelastic waveguides of arbitrary geometry embedded in infinite solid or liquid media. Dispersion of leaky and non-leaky guided waves in terms of speed and attenuation, as well as the radiated wavefields, can be computed. The results obtained in this thesis can be helpful for the design of both actuation and sensing systems in practical application, as well as to tune experimental setup.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new class of inorganic-organic hybrid polymers could successfully been prepared by the combination of different polymerization techniques. The access to a broad range of organic polymers incorporated into the hybrid polymer was realized using two independent approaches.rnIn the first approach a functional poly(silsesquioxane) (PSSQ) network was pre-formed, which was capable to initiate a controlled radical polymerization to graft organic vinyl-type monomers from the PSSQ precursor. As controlled radical polymerization techniques atom transfer radical polymerization (ATRP), as well as reversible addition fragmentation chain transfer (RAFT) polymerization could be used after defined tuning of the PSSQ precursor either toward a PSSQ macro-initiator or to a PSSQ macro-chain-transfer-agent. The polymerization pathway, consisting of polycondensation of trialkoxy-silanes followed by grafting-from polymerization of different monomers, allowed synthesis of various functional hybrid polymers. A controlled synthesis of the PSSQ precursors could successfully be performed using a microreactor setup; the molecular weight could be adjusted easily while the polydispersity index could be decreased well below 2.rnThe second approach aimed to incorporate differently derived organic polymers. As examples, polycarbonate and poly(ethylene glycol) were end-group-modified using trialkoxysilanes. After end-group-functionalization these organic polymers could be incorporated into a PSSQ network.rnThese different hybrid polymers showed extraordinary coating abilities. All polymers could be processed from solution by spin-coating or dip-coating. The high amount of reactive silanol moieties in the PSSQ part could be cross-linked after application by annealing at 130° for 1h. Not only cross-linking of the whole film was achieved, which resulted in mechanical interlocking with the substrate, also chemical bonds to metal or metal oxide surfaces were formed. All coating materials showed high stability and adhesion onto various underlying materials, reaching from metals (like steel or gold) and metal oxides (like glass) to plastics (like polycarbonate or polytetrafluoroethylene).rnAs the material and the synthetic pathway were very tolerant toward different functionalities, various functional monomers could be incorporated in the final coating material. The incorporation of N-isopropylacrylamide yielded in temperature-responsive surface coatings, whereas the incorporation of redox-active monomers allowed the preparation of semi-conductive coatings, capable to produce smooth hole-injection layers on transparent conductive electrodes used in optoelectronic devices.rnThe range of possible applications could be increased tremendously by incorporation of reactive monomers, capable to undergo fast and quantitative conversions by polymer-analogous reactions. For example, grafting active esters from a PSSQ precursor yielded a reactive surface coating after application onto numerous substrates. Just by dipping the coated substrate into a solution of a functionalized amine, the desired function could be immobilized at the interface as well as throughout the whole film. The obtained reactive surface coatings could be used as basis for different functional coatings for various applications. The conversion with specifically tuned amines yielded in surfaces with adjustable wetting behaviors, switchable wetting behaviors or as recognition element for surface-oriented bio-analytical devices. The combination of hybrid materials with orthogonal reactivities allowed for the first time the preparation of multi-reactive surfaces which could be functionalized sequentially with defined fractions of different groups at the interface. rnThe introduced concept to synthesis functional hybrid polymers unifies the main requirements on an ideal coating material. Strong adhesion on a wide range of underlying materials was achieved by secondary condensation of the PSSQ part, whereas the organic part allowed incorporation of various functionalities. Thus, a flexible platform to create functional and reactive surface coatings was achieved, which could be applied to different substrates. rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nuclear masses are an important quantity to study nuclear structure since they reflect the sum of all nucleonic interactions. Many experimental possibilities exist to precisely measure masses, out of which the Penning trap is the tool to reach the highest precision. Moreover, absolute mass measurements can be performed using carbon, the atomic-mass standard, as a reference. The new double-Penning trap mass spectrometer TRIGA-TRAP has been installed and commissioned within this thesis work, which is the very first experimental setup of this kind located at a nuclear reactor. New technical developments have been carried out such as a reliable non-resonant laser ablation ion source for the production of carbon cluster ions and are still continued, like a non-destructive ion detection technique for single-ion measurements. Neutron-rich fission products will be available by the reactor that are important for nuclear astrophysics, especially the r-process. Prior to the on-line coupling to the reactor, TRIGA-TRAP already performed off-line mass measurements on stable and long-lived isotopes and will continue this program. The main focus within this thesis was on certain rare-earth nuclides in the well-established region of deformation around N~90. Another field of interest are mass measurements on actinoids to test mass models and to provide direct links to the mass standard. Within this thesis, the mass of 241-Am could be measured directly for the first time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electromagnetic form factors of the proton are fundamental quantities sensitive to the distribution of charge and magnetization inside the proton. Precise knowledge of the form factors, in particular of the charge and magnetization radii provide strong tests for theory in the non-perturbative regime of QCD. However, the existing data at Q^2 below 1 (GeV/c)^2 are not precise enough for a hard test of theoretical predictions.rnrnFor a more precise determination of the form factors, within this work more than 1400 cross sections of the reaction H(e,e′)p were measured at the Mainz Microtron MAMI using the 3-spectrometer-facility of the A1-collaboration. The data were taken in three periods in the years 2006 and 2007 using beam energies of 180, 315, 450, 585, 720 and 855 MeV. They cover the Q^2 region from 0.004 to 1 (GeV/c)^2 with counting rate uncertainties below 0.2% for most of the data points. The relative luminosity of the measurements was determined using one of the spectrometers as a luminosity monitor. The overlapping acceptances of the measurements maximize the internal redundancy of the data and allow, together with several additions to the standard experimental setup, for tight control of systematic uncertainties.rnTo account for the radiative processes, an event generator was developed and implemented in the simulation package of the analysis software which works without peaking approximation by explicitly calculating the Bethe-Heitler and Born Feynman diagrams for each event.rnTo separate the form factors and to determine the radii, the data were analyzed by fitting a wide selection of form factor models directly to the measured cross sections. These fits also determined the absolute normalization of the different data subsets. The validity of this method was tested with extensive simulations. The results were compared to an extraction via the standard Rosenbluth technique.rnrnThe dip structure in G_E that was seen in the analysis of the previous world data shows up in a modified form. When compared to the standard-dipole form factor as a smooth curve, the extracted G_E exhibits a strong change of the slope around 0.1 (GeV/c)^2, and in the magnetic form factor a dip around 0.2 (GeV/c)^2 is found. This may be taken as indications for a pion cloud. For higher Q^2, the fits yield larger values for G_M than previous measurements, in agreement with form factor ratios from recent precise polarized measurements in the Q2 region up to 0.6 (GeV/c)^2.rnrnThe charge and magnetic rms radii are determined as rn⟨r_e⟩=0.879 ± 0.005(stat.) ± 0.004(syst.) ± 0.002(model) ± 0.004(group) fm,rn⟨r_m⟩=0.777 ± 0.013(stat.) ± 0.009(syst.) ± 0.005(model) ± 0.002(group) fm.rnThis charge radius is significantly larger than theoretical predictions and than the radius of the standard dipole. However, it is in agreement with earlier results measured at the Mainz linear accelerator and with determinations from Hydrogen Lamb shift measurements. The extracted magnetic radius is smaller than previous determinations and than the standard-dipole value.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the field of organic optoelectronics, the nanoscale structure of the materials has huge im-pact on the device performance. Here, scanning force microscopy (SFM) techniques become increasingly important. In addition to topographic information, various surface properties can be recorded on a nanometer length scale, such as electrical conductivity (conductive scanning force microscopy, C-SFM) and surface potential (Kelvin probe force microscopy, KPFM).rnrnIn the context of this work, the electrical SFM modes were applied to study the interplay be-tween morphology and electrical properties in hybrid optoelectronic structures, developed in the group of Prof. J. Gutmann (MPI-P Mainz). In particular, I investigated the working prin-ciple of a novel integrated electron blocking layer system. A structure of electrically conduct-ing pathways along crystalline TiO2 particles in an insulating matrix of a polymer derived ceramic was found and insulating defect structures could be identified. In order to get insights into the internal structure of a device I investigated a working hybrid solar cell by preparing a cross cut with focused ion beam polishing. With C-SFM, the functional layers could be identified and the charge transport properties of the novel active layer composite material could be studied. rnrnIn C-SFM, soft surfaces can be permanently damaged by (i) tip induced forces, (ii) high elec-tric fields and (iii) high current densities close to the SFM-tip. Thus, an alternative operation based on torsion mode topography imaging in combination with current mapping was intro-duced. In torsion mode, the SFM-tip vibrates laterally and in close proximity to the sample surface. Thus, an electrical contact between tip and sample can be established. In a series of reference experiments on standard surfaces, the working mechanism of scanning conductive torsion mode microscopy (SCTMM) was investigated. Moreover, I studied samples covered with free standing semiconducting polymer nano-pillars that were developed in the group of Dr. P. Theato (University Mainz). The application of SCTMM allowed non-destructive imag-ing of the flexible surface at high resolution while measuring the conductance on individual pillarsrnrnIn order to study light induced electrical effects on the level of single nanostructures, a new SFM setup was built. It is equipped with a laser sample illumination and placed in inert at-mosphere. With this photoelectric SFM, I investigated the light induced response in function-alized nanorods that were developed in the group of Prof. R. Zentel (University Mainz). A block-copolymer containing an anchor block and dye moiety and a semiconducting conju-gated polymer moiety was synthesized and covalently bound to ZnO nanorods. This system forms an electron donor/acceptor interface and can thus be seen as a model system of a solar cell on the nanoscale. With a KPFM study on the illuminated samples, the light induced charge separation between the nanorod and the polymeric corona could not only be visualized, but also quantified.rnrnThe results demonstrate that electrical scanning force microscopy can study fundamental processes in nanostructures and give invaluable feedback to the synthetic chemists for the optimization of functional nanomaterials.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hypernuclear physics is currently attracting renewed interest, due tornthe important role of hypernuclei spectroscopy rn(hyperon-hyperon and hyperon-nucleon interactions) rnas a unique toolrnto describe the baryon-baryon interactions in a unified way and to rnunderstand the origin of their short-range.rnrnHypernuclear research will be one of the main topics addressed by the {sc PANDA} experimentrnat the planned Facility for Antiproton and Ion Research {sc FAIR}.rnThanks to the use of stored $overline{p}$ beams, copiousrnproduction of double $Lambda$ hypernuclei is expected at thern{sc PANDA} experiment, which will enable high precision $gamma$rnspectroscopy of such nuclei for the first time.rnAt {sc PANDA} excited states of $Xi^-$ hypernuclei will be usedrnas a basis for the formation of double $Lambda$ hypernuclei.rnFor their detection, a devoted hypernuclear detector setup is planned. This setup consists ofrna primary nuclear target for the production of $Xi^{-}+overline{Xi}$ pairs, a secondary active targetrnfor the hypernuclei formation and the identification of associated decay products and a germanium array detector to perform $gamma$ spectroscopy.rnrnIn the present work, the feasibility of performing high precision $gamma$rnspectroscopy of double $Lambda$ hypernuclei at the {sc PANDA} experiment has been studiedrnby means of a Monte Carlo simulation. For this issue, the designing and simulation of the devoted detector setup as well as of the mechanism to produce double $Lambda$ hypernuclei have been optimizedrntogether with the performance of the whole system. rnIn addition, the production yields of double hypernuclei in excitedrnparticle stable states have been evaluated within a statistical decay model.rnrnA strategy for the unique assignment of various newly observed $gamma$-transitions rnto specific double hypernuclei has been successfully implemented by combining the predicted energy spectra rnof each target with the measurement of two pion momenta from the subsequent weak decays of a double hypernucleus.rn% Indeed, based on these Monte Carlo simulation, the analysis of the statistical decay of $^{13}_{Lambda{}Lambda}$B has been performed. rn% As result, three $gamma$-transitions associated to the double hypernuclei $^{11}_{Lambda{}Lambda}$Bern% and to the single hyperfragments $^{4}_{Lambda}$H and $^{9}_{Lambda}$Be, have been well identified.rnrnFor the background handling a method based on time measurement has also been implemented.rnHowever, the percentage of tagged events related to the production of $Xi^{-}+overline{Xi}$ pairs, variesrnbetween 20% and 30% of the total number of produced events of this type. As a consequence, further considerations have to be made to increase the tagging efficiency by a factor of 2.rnrnThe contribution of the background reactions to the radiation damage on the germanium detectorsrnhas also been studied within the simulation. Additionally, a test to check the degradation of the energyrnresolution of the germanium detectors in the presence of a magnetic field has also been performed.rnNo significant degradation of the energy resolution or in the electronics was observed. A correlationrnbetween rise time and the pulse shape has been used to correct the measured energy. rnrnBased on the present results, one can say that the performance of $gamma$ spectroscopy of double $Lambda$ hypernuclei at the {sc PANDA} experiment seems feasible.rnA further improvement of the statistics is needed for the background rejection studies. Moreover, a more realistic layout of the hypernuclear detectors has been suggested using the results of these studies to accomplish a better balance between the physical and the technical requirements.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid and sensitive detection of chemical and biological analytes becomes increasingly important in areas such as medical diagnostics, food control and environmental monitoring. Optical biosensors based on surface plasmon resonance (SPR) and optical waveguide spectroscopy have been extensively pushed forward in these fields. In this study, we combine SPR, surface plasmon-enhanced fluorescence spectroscopy (SPFS) and optical waveguide spectroscopy with hydrogel thin film for highly sensitive detection of molecular analytes.rnrnA novel biosensor based on SPFS which was advanced through the excitation of long range surface plasmons (LRSPs) is reported in this study. LRSPs are special surface plasmon waves propagating along thin metal films with orders of magnitude higher electromagnetic field intensity and lower damping than conventional SPs. Therefore, their excitation on the sensor surface provides further increased fluorescence signal. An inhibition immunoassay based on LRSP-enhanced fluorescence spectroscopy (LRSP-FS) was developed for the detection of aflatoxin M1 (AFM1) in milk. The biosensor allowed for the detection of AFM1 in milk at concentrations as low as 0.6 pg mL-1, which is about two orders of magnitude lower than the maximum AFM1 residue level in milk stipulated by the European Commission legislation.rnrnIn addition, LRSPs probe the medium adjacent to the metallic surface with more extended evanescent field than regular SPs. Therefore, three-dimensional binding matrices with up to micrometer thickness have been proposed for the immobilization of biomolecular recognition elements with large surface density that allows to exploit the whole evanescent field of LRSP. A photocrosslinkable carboxymethyl dextran (PCDM) hydrogel thin film is used as a binding matrix, and it is applied for the detection of free prostate specific antigen (f-PSA) based on the LRSP-FS and sandwich immunoassay. We show that this approach allows for the detection of f-PSA at low femto-molar range, which is approximately four orders of magnitude lower than that for direct detection of f-PSA based on the monitoring of binding-induced refractive index changes.rnrnHowever, a three dimensional hydrogel binding matrix with micrometer thickness can also serve as an optical waveguide. Based on the measurement of binding-induced refractive index changes, a hydrogel optical waveguide spectroscopy (HOWS) is reported for a label-free biosensor. This biosensor is implemented by using a SPR optical setup in which a carboxylated poly(N-isoproprylacrylamide) (PNIPAAm) hydrogel film is attached on a metallic surface and modified by protein catcher molecules. Compared to regular SPR biosensor with thiol self-assembled monolayer (SAM), HOWS provides an order of magnitude improved resolution in the refractive index measurements and enlarged binding capacity owing to its low damping and large swelling ratio, respectively. A model immunoassay experiment revealed that HOWS allowed detection of IgG molecules with a 10 pM limit of detection (LOD) that was five-fold lower than that achieved for SPR with thiol SAM. For the high capacity hydrogel matrix, the affinity binding was mass transport limited.rnrnThe mass transport of target molecules to the sensor surface can play as critical a role as the chemical reaction itself. In order to overcome the diffusion-limited mass transfer, magnetic iron oxide nanoparticles were employed. The magnetic nanoparticles (MNPs) can serve both as labels providing enhancement of the refractive index changes, and “vehicles” for rapidly delivering the analytes from sample solution to an SPR sensor surface with a gradient magnetic field. A model sandwich assay for the detection of β human chorionic gonadotropin (βhCG) has been utilized on a gold sensor surface with metallic diffraction grating structure supporting the excitation of SPs. Various detection formats including a) direct detection, b) sandwich assay, c) MNPs immunoassay without and d) with applied magnetic field were compared. The results show that the highly-sensitive MNPs immunoassay improves the LOD on the detection of βhCG by a factor of 5 orders of magnitude with respect to the direct detection.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Questo elaborato nasce da uno stage presso lo stabilimento Bonfiglioli Trasmital S.p.A. di Forlì, un’azienda manifatturiera specializzata nella produzione, costruzione e distribuzione di motoriduttori di velocità, sistemi di azionamento e motoriduttori epicicloidali applicati nel campo industriale, dell’automazione, delle macchine movimento terra e nell’ambito delle energie alternative. Il progetto ha lo scopo di aumentare la disponibilità di un impianto di tempra ad induzione. La scelta di tale impianto quale oggetto dell’attività, proviene da un’analisi delle ore di disponibilità perse per inefficienza, nell’anno 2012, in tutto il reparto di lavorazione meccanica dello stabilimento produttivo di Forlì e dall’analisi dell’OEE (Overall equipment effectiveness), indicatore principale per stabilire l’efficienza di un impianto. Analizzando la natura delle perdite del macchinario, tipicamente guasti, micro fermate e setup, si è deciso di applicare le tecniche di TPM e dello SMED: il TPM (Total Productive Maintenance) persegue l’obiettivo di migliorare la produttività degli impianti e la loro efficacia, grazie alla riduzione delle cause di perdita ricercando il miglioramento continuo del processo di produzione e della qualità, mentre lo SMED (Single-Minute Exchange of Die) è una metodologia volta alla riduzione dei tempi di cambio produzione; la grande innovazione di tale teoria risiede nella possibilità di ridurre fortemente i tempi impiegati per effettuare un’operazione di setup con un solo digit ossia in un lasso di tempo inferiore a dieci minuti.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Im Juli 2009 wurde am Mainzer Mikrotron (MAMI) erstmal ein Experiment durchgeführt, bei dem ein polarisiertes 3He Target mit Photonen im Energiebereich von 200 bis 800 MeV untersucht wurde. Das Ziel dieses Experiments war die Überprüfung der Gerasimov-Drell-Hearn Summenregel am Neutron. Die Verwendung der Messdaten welche mit dem polarisierten 3He Target gewonnen wurden, geben - im Vergleich mit den bereits existieren Daten vom Deuteron - aufgrund der Spin-Struktur des 3He einen komplementären und direkteren Zugang zum Neutron. Die Messung des totalen helizitätsabhängigen Photoabsorptions-Wirkungsquerschnitts wurde mittels eines energiemarkierten Strahls von zirkular polarisierten Photonen, welcher auf das longitudinal polarisierte 3He Target trifft, durchgeführt. Als Produktdetektoren kamen der Crystal Ball (4π Raumabdeckung), TAPS (als ”Vorwärtswand”) sowie ein Schwellen-Cherenkov-Detektor (online Veto zur Reduktion von elektromagnetischen Ereignissen) zum Einsatz. Planung und Aufbau der verschiedenen komponenten Teile des 3He Experimentaufbaus war ein entscheidender Teil dieser Dissertation und wird detailliert in der vorliegenden Arbeit beschrieben. Das Detektorsystem als auch die Analyse-Methoden wurden durch die Messung des unpolarisierten, totalen und inklusiven Photoabsoprtions-Wirkungsquerschnitts an flüssigem Wasserstoff getestet. Hierbei zeigten die Ergebnisse eine gute Übereinstimmung mit bereits zuvor publizierten Daten. Vorläufige Ergebnisse des unpolarisierten totalen Photoabsorptions-Wirkungsquerschnitts sowie der helizitätsabhängige Unterschied zwischen Photoabsorptions-Wirkungsquerschnitten an 3He im Vergleich zu verschiedenen theoretischen Modellen werden vorgestellt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Im Zuge dieser Arbeit ist ein Massenspektrometer zur flugzeuggetragenen Messung von HNO3 und HONO auf dem neuen deutschen Forschungsflugzeug HALO aufgebaut worden (AIMS - Atmospheric chemical Ionization Mass Spectrometer). Die Ionisation der HNO3- und HONO-Moleküle erfolgt chemisch durch Reaktion mit SF5- -Ionen. Basierend auf den Ergebnissen von Laborversuchen wurden die Betriebsparameter optimiert, die Einzelkomponenten im HALO-Rack zusammengestellt und eine Einlassleitung entworfen, die Wandeffekte minimiert und Untergrundmessungen und HNO3-Kalibrationen im Flug ermöglicht. Die Empfindlichkeit der Messung von HNO3 und HONO wurde ebenso im Labor untersucht wie Interferenzen mit Wasserdampf und Ozon. Die HONO-Vergleichskampagne FIONA am Europäischen Photoreaktor (EUPHORE) in Valencia war die erste Messkampagne mit AIMS. Bei den offenen Vergleichsmessungen stimmten die von AIMS gemessenen HONO-Mischungsverhältnisse innerhalb +-20% mit dem Median von 9 weiteren HONO-Messungen überein. Die ersten flugzeuggetragenen Messungen mit AIMS werden im Verlauf der HALO-Missionen ML-CIRRUS und TACTS stattfinden. Neben dem Aufbau und der Charakterisierung von AIMS war die Analyse der Aufnahme von HNO3 in Eispartikel von Kondensstreifen und Zirren Gegenstand dieser Arbeit. Die Aufnahme von HNO3 in Kondensstreifeneispartikel wurde erstmals systematisch anhand einer Flugzeugmesskampagne (CIRRUS-III) untersucht. Während CIRRUS-III im November 2006 wurden Zirren und zufällig knapp 40 persistente Kondensstreifen über Deutschland und Nordeuropa beprobt. Die Messungen fanden in Höhen zwischen 10 und 11.5 km und bei Temperaturen zwischen 210 und 230 K statt. Die HNO3-Konzentration wurde mit Hilfe von NOy-Messungen bestimmt. Im Mittel war in Kondensstreifen ein größerer Anteil des Gesamt-HNO3 in den Eispartikeln gebunden (6 %) als in Zirren (3 %). Das Gasphasenäquivalent des eisgebundenen HNO3 betrug in Zirren durchschnittlich 6 pmol/mol, in Kondensstreifen 14 pmol/mol und in jungen Kondensstreifen (Alter<1 h) 21 pmol/mol. Das Mischungsverhältnis von HNO3 zu H2O in Eispartikeln war in Kondensstreifen leicht höher als in Zirren unter ähnlichen meteorologischen Bedingungen. Ursächlich für die höheren Werte in persistenten Kondensstreifen sind wahrscheinlich die hohen HNO3-Konzentrationen in den Abgasfahnen der Flugzeuge bei der Kondensstreifenbildung. Die beobachtete Abnahme des HNO3/H2O-Molverhältnisses mit zunehmendem Effektivdurchmesser der Eispartikel deutet an, dass die HNO3-Konzentrationen in Eispartikeln von jungen Kondensstreifen durch die Aufnahme von Abgas-HNO3 in die gefrierenden Aerosolpartikel bestimmt wird. Die Konzentrationen in älteren Kondensstreifen werden zunehmend durch das Vergraben von Umgebungs-HNO3 in wachsenden Eispartikeln kontrolliert. Diese Studie leistet einen Beitrag zu einem besseren Prozessverständnis der HNO3-Aufnahme in atmosphärische Eispartikel. Sie motiviert die Nutzung persistenter Kondensstreifen als atmosphärisches Labor zur Untersuchung der Spurengasaufnahme in wachsende Eispartikel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Within this work, a particle-polymer surface system is studied with respect to the particle-surface interactions. The latter are governed by micromechanics and are an important aspect for a wide range of industrial applications. Here, a new methodology is developed for understanding the adhesion process and measure the relevant forces, based on the quartz crystal microbalance, QCM. rnThe potential of the QCM technique for studying particle-surface interactions and reflect the adhesion process is evaluated by carrying out experiments with a custom-made setup, consisting of the QCM with a 160 nm thick film of polystyrene (PS) spin-coated onto the quartz and of glass particles, of different diameters (5-20µm), deposited onto the polymer surface. Shifts in the QCM resonance frequency are monitored as a function of the oscillation amplitude. The induced frequency shifts of the 3rd overtone are found to decrease or increase, depending on the particle-surface coupling type and the applied oscillation (frequency and amplitude). For strong coupling the 3rd harmonic decreased, corresponding to an “added mass” on the quartz surface. However, positive frequency shifts are observed in some cases and are attributed to weak-coupling between particle and surface. Higher overtones, i.e. the 5th and 7th, were utilized in order to derive additional information about the interactions taking place. For small particles, the shift for specific overtones can increase after annealing, while for large particle diameters annealing causes a negative frequency shift. The lower overtones correspond to a generally strong-coupling regime with mainly negative frequency shifts observed, while the 7th appears to be sensitive to the contact break-down and the recorded shifts are positive.rnDuring oscillation, the motion of the particles and the induced frequency shift of the QCM are governed by a balance between inertial forces and contact forces. The adherence of the particles can be increased by annealing the PS film at 150°C, which led to the formation of a PS meniscus. For the interpretation, the Hertz, Johnson-Kendall-Roberts, Derjaguin-Müller-Toporov and the Mindlin theory of partial slip are considered. The Mindlin approach is utilized to describe partial slip. When partial slip takes place induced by an oscillating load, a part of the contact ruptures. This results in a decrease of the effective contact stiffness. Additionally, there are long-term memory effects due to the consolidation which along with the QCM vibrations induce a coupling increase. However, the latter can also break the contact, lead to detachment and even surface damage and deformation due to inertia. For strong coupling the particles appear to move with the vibrations and simply act as added effective mass leading to a decrease of the resonance frequency, in agreement with the Sauerbrey equation that is commonly used to calculate the added mass on a QCM). When the system enters the weak-coupling regime the particles are not able to follow the fast movement of the QCM surface. Hence, they effectively act as adding a “spring” with an additional coupling constant and increase the resonance frequency. The frequency shift, however, is not a unique function of the coupling constant. Furthermore, the critical oscillation amplitude is determined, above which particle detach. No movement is detected at much lower amplitudes, while for intermediate values, lateral particle displacement is observed. rnIn order to validate the QCM results and study the particle effects on the surface, atomic force microscopy, AFM, is additionally utilized, to image surfaces and measure surface forces. By studying the surface of the polymer film after excitation and particle removal, AFM imaging helped in detecting three different meniscus types for the contact area: the “full contact”, the “asymmetrical” and a third one including a “homocentric smaller meniscus”. The different meniscus forms result in varying bond intensity between particles and polymer film, which could explain the deviation between number of particles per surface area measured by imaging and the values provided by the QCM - frequency shift analysis. The asymmetric and the homocentric contact types are suggested to be responsible for the positive frequency shifts observed for all three measured overtones, i.e. for the weak-coupling regime, while the “full contact” type resulted in a negative frequency shift, by effectively contributing to the mass increase of the quartz..rnThe interplay between inertia and contact forces for the particle-surface system leads to strong- or weak-coupling, with the particle affecting in three mentioned ways the polymer surface. This is manifested in the frequency shifts of the QCM system harmonics which are used to differentiate between the two interaction types and reflect the overall state of adhesion for particles of different size.rn