991 resultados para Test facilities.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dissolution test for in vitro evaluation of tablet dosage forms containing 10 mg of rupatadine was developed and validated by RP-LC. A discriminatory dissolution method was established using apparatus paddle at a stirring rate of 50 rpm with 900 mL of deaerated 0.01 M hydrochloric acid. The proposed method was validated yielding acceptable results for the parameters evaluated, and was applied for the quality control analysis of rupatadine tablets, and to evaluate the formulation during an accelerated stability study. Moreover, quantitative analyses were also performed, to compare the applicability of the RP-LC and the LC-MS/MS methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article outlines a procedure that was used to develop a written test for evaluating the conceptual knowledge of chemical equilibrium constant among university students. The concepts in the subject matter were carefully defined through propositional statements. Students' understanding of the topic was determined through interviews. These data were used to produce nine multiple choice questions. Each question was designed to identify misconceptions related to the chemical equilibrium constant. The test was evaluated by foure associate professors and was administred to a total of 196 spanish university students. This test has a Cronbach's alpha reliability of 0.63 and its content validity values ranged from 3.7 to 5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern sophisticated telecommunication devices require even more and more comprehensive testing to ensure quality. The test case amount to ensure well enough coverage of testing has increased rapidly and this increased demand cannot be fulfilled anymore only by using manual testing. Also new agile development models require execution of all test cases with every iteration. This has lead manufactures to use test automation more than ever to achieve adequate testing coverage and quality. This thesis is separated into three parts. Evolution of cellular networks is presented at the beginning of the first part. Also software testing, test automation and the influence of development model for testing are examined in the first part. The second part describes a process which was used to implement test automation scheme for functional testing of LTE core network MME element. In implementation of the test automation scheme agile development models and Robot Framework test automation tool were used. In the third part two alternative models are presented for integrating this test automation scheme as part of a continuous integration process. As a result, the test automation scheme for functional testing was implemented. Almost all new functional level testing test cases can now be automated with this scheme. In addition, two models for integrating this scheme to be part of a wider continuous integration pipe were introduced. Also shift from usage of a traditional waterfall model to a new agile development based model in testing stated to be successful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artikel i konferensrapport.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work established the adequate temperature and the period of exposition for the accelerated ageing test with diasporas of Myracrodruon urundeuva from an area of the Cerrado in the state of Mato Grosso, Brazil. Before and after the ageing, at the temperatures of 40ºC, 41ºC, 42ºC and 45ºC combined with periods of 12, 18, 24, 30 and 36 hours, the water content and germination were evaluated. For each treatment, 12g of diasporas in mini chambers with 40 mL of distilled water were submitted to the accelerated ageing test. A total of 100 diasporas, divided into four replications, in plastic boxes, on two sheets of blotting paper, in germinator at 25ºC and 8 hours of photoperiod were germinated. In all treatments the content of water of the aged diasporas was superior to 20% and this value stabilized itself between 25% and 28%, from the 18 hours of exposition. Independently of the tested periods, the ageing at the temperatures of 40ºC, 41ºC and 42ºC did not affect the germination. After the ageing at 45ºC, the germination did not differ among the periods of 12, 18 and 24 hours of exposition, but in all these periods it was inferior to the control and superior to the periods of 30 and 36 hours. In these last two periods, fungi were observed. The accelerated ageing of diasporas of Myracrodruon urundeuva should be conducted at the temperature of 45ºC, during the exposition periods of 12 to 24 hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, the components important for testing work and organisational test process are identified and analysed. This work focuses on the testing activities in reallife software organisations, identifying the important test process components, observing testing work in practice, and analysing how the organisational test process could be developed. Software professionals from 14 different software organisations were interviewed to collect data on organisational test process and testing‐related factors. Moreover, additional data on organisational aspects was collected with a survey conducted on 31 organisations. This data was further analysed with the Grounded Theory method to identify the important test process components, and to observe how real‐life test organisations develop their testing activities. The results indicate that the test management at the project level is an important factor; the organisations do have sufficient test resources available, but they are not necessarily applied efficiently. In addition, organisations in general are reactive; they develop their process mainly to correct problems, not to enhance their efficiency or output quality. The results of this study allows organisations to have a better understanding of the test processes, and develop towards better practices and a culture of preventing problems, not reacting to them.