970 resultados para Rational Curves


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Studying stroke rates in a whole community is a rational way to assess the quality of patient care and primary prevention. However, there are few studies of trends in stroke rates worldwide and none in Brazil. Objective: Established study methods were used to define the rates for first ever stroke in a defined population in Brazil compared with similar data obtained and published in 1995. Methods: All stroke cases occurring in the city of Joinville during 2005-2006 were prospectively ascertained. Crude incidence and mortality rates were determined, and age adjusted rates and 30 day case fatality were calculated and compared with the 1995 data. Results: Of the 1323 stroke cases registered, 759 were first ever strokes. The incidence rate per 100 000 was 105.4 (95% CI 98.0 to 113.2), mortality rate was 23.9 (95% CI 20.4 to 27.8) and the 30 day case fatality was 19.1%. Compared with the 1995 data, we found that the incidence had decreased by 27%, mortality decreased by 37% and the 30 day case fatality decreased by 28%. Conclusions: Using defined criteria we showed that in an industrial southern Brazilian city, stroke rates are similar to those from developed countries. A significant decrease in stroke rates over the past decade was also found, suggesting an improvement in primary prevention and inpatient care of stroke patients in Joinville.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Mini-Mental State Examination (MMSE) is the most widely used instrument for the screening of cognitive impairment worldwide, but its ability to produce valid estimates of dementia in populations of low socioeconomic status and minimal literacy skills has not been adequately established. The authors investigated the psychometric properties of the MMSE in a community-based sample of older Brazilians. Cross-sectional one-phase population-based study of all residents of pre-defined areas of the city of Sao Paulo, aged 65 years or over. The Brazilian version of the MMSE was compared with DSM-IV diagnosis of dementia assessed with a harmonized one-phase procedure developed by the 10/66 Dementia Research Group. Analyses were performed with 1,933 participants of the SPAH study. Receiver operating characteristic analysis showed that the MMSE cut-point of 14/15 was associated with 78.7% sensitivity and 77.8% specificity for the diagnosis of dementia amongst participants with no formal education, and the cut-point 17/18 with 91.9% sensitivity and 89.5% specificity for those with at least 1 year of formal education (areas under the curves 0.87 and 0.94, respectively; P = 0.03). Even with these best fitting cut-points, the MMSE estimate of the prevalence of dementia was four times higher than determined by the DSM-IV criteria. Education, age, sex and income influenced MMSE scores, independently of dementia caseness. The MMSE is an adequate tool for screening dementia in older adults with minimum literacy skills, but misclassification is unacceptably high for older adults who are illiterate, which has serious consequences for research and clinical practice in low and middle income countries, where the proportion of illiteracy among older adults is high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aims of this study were to analyze the overall survival of patients with cirrhosis and small hepatocellular carcinoma (HCC) and identify independent pretreatment predictors of survival in Brazil. Methods: Between 1998 and 2003, 74 patients with cirrhosis and small HCC were evaluated. Predictors of survival were identified using the Kaplan-Meier survival curves and the Cox model. Results: The overall survival rates were 80%, 41%, and 17% at 12, 36, and 60 months, respectively. The mean length of follow-up after HCC diagnosis was 23 months (median 22 mo, range: I to 86 mo) for the entire group. Univariate analysis showed that model for endstage liver disease (MELD) score (P = 0.016), Child-Pugh classification (P = 0.007), alpha-fetoprotein level (P = 0.006), number of nodules (P = 0.041), tumor diameter (P = 0.009), and vascular invasion (P < 0.0001) were significant predictors Of Survival. Cox regression analysis identified vascular invasion (relative risk = 14.60, confidence interval 95% = 3.3-64.56, P < 0.001) and tumor size > 20 mm (relative risk = 2.14, confidence interval 95% = 1.07-4.2, P = 0.030) as independent predictors of decreased survival. Treatment of HCC was related to increased overall survival. Conclusions: Identification of HCC smaller than 20 mm is associated with longer survival. Presence of vascular invasion, even in small tumors, maybe associated with poor prognosis. Treatment of small tumors Of LIP to 20 mm diameter is related to increased survival.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective: Light`s criteria are frequently used to evaluate the exudative or transudative nature of pleural effusions. However, misclassification resulting from the use of Light`s criteria has been reported, especially in the setting of diuretic use in patients with heart failure (HF). The objective of this study was to evaluate the utility of B-type natriuretic peptide (BNP) measurements as a diagnostic tool for determining the cardiac aetiology of pleural effusions. Methods: Patients with pleural effusions attributable to HF (n = 34), hepatic hydrothorax (n = 10), pleural effusions due to cancer (n = 21) and pleural effusions due to tuberculosis (n = 12) were studied. Diagnostic thoracentesis was performed for all 77 patients. Receiver operating characteristic (ROC) curves were constructed to determine the diagnostic accuracy of plasma BNP and pleural fluid BNP for the prediction of HF. Results: The areas under the ROC curves were 0.987 (95% CI 0.93-0.998) for plasma BNP and 0.949 (95% CI 0.874-0.986) for pleural fluid BNP, for distinguishing between patients with pleural effusions caused by HF (n = 34) and those with pleural effusions attributable to other causes (n = 43). The cut-off concentrations with the highest diagnostic accuracy for the diagnosis of HF as the cause of pleural effusion were 132 pg/mL for plasma BNP (sensitivity 97.1%, specificity 97.4%) and 127 pg/mL for pleural fluid BNP (sensitivity 97.1%, specificity 87.8%). Conclusions: In patients with pleural effusions of suspected cardiac origin, measurements of BNP in plasma and pleural fluid may be useful for the diagnosis of HF as the underlying cause.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity and optic disc size on the diagnostic accuracies of optic nerve head (ONH), retinal nerve fiber layer (RNFL), and macular parameters with RTVue (Optovue, Fremont, CA) spectral domain optical coherence tomography (SDOCT) in glaucoma. METHODS. 110 eyes of 62 normal subjects and 193 eyes of 136 glaucoma patients from the Diagnostic Innovations in Glaucoma Study underwent ONH, RNFL, and macular imaging with RTVue. Severity of glaucoma was based on visual field index (VFI) values from standard automated perimetry. Optic disc size was based on disc area measurement using the Heidelberg Retina Tomograph II (Heidelberg Engineering, Dossenheim, Germany). Influence of disease severity and disc size on the diagnostic accuracy of RTVue was evaluated by receiver operating characteristic (ROC) and logistic regression models. RESULTS. Areas under ROC curve (AUC) of all scanning areas increased (P < 0.05) as disease severity increased. For a VFI value of 99%, indicating early damage, AUCs for rim area, average RNLI thickness, and ganglion cell complex-root mean square were 0.693, 0.799, and 0.779, respectively. For a VFI of 70%, indicating severe damage, corresponding AUCs were 0.828, 0.985, and 0.992, respectively. Optic disc size did not influence the AUCs of any of the SDOCT scanning protocols of RTVue (P > 0.05). Sensitivity of the rim area increased and specificity decreased in large optic discs. CONCLUSIONS. Diagnostic accuracies of RTVue scanning protocols for glaucoma were significantly influenced by disease severity. Sensitivity of the rim area increased in large optic discs at the expense of specificity. (Invest Ophthalmol Vis Sci. 2011;92:1290-1296) DOI:10.1167/iovs.10-5516

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Cambridge Cognitive Examination (CAMCOG) is a useful test in screening for Alzheimer`s disease (AD). However, the interpretation of CAMCOG cut-off scores is problematic and reference values are needed for different educational strata. Given the importance of earlier diagnoses of mild dementia, new cut-off values are required which take into account patients with low levels of education. This study aims to evaluate whether the CAMCOG can be used as an accurate screening test among AD patients and normal controls with different educational levels. Methods: Cross-sectional assessment was undertaken of 113 AD and 208 elderly controls with heterogeneous educational levels (group 1: 1-4 years; group 2: 5-8 years; and group 3: >= 9 years) from a geriatric clinic. submitted to a thorough diagnostic evaluation for AD including the Cambridge Examination for Mental Disorders of the Elderly (CAMDEX). Controls had no cognitive or mood complaints. Sensitivity (SE) and specificity (SP) for the CAMCOG in each educational group was assessed with receiver-operator-characteristic (ROC) curves. Results: CAMCOG mean values were lower when education was reduced in both diagnostic groups (controls - group 1: 87; group 2: 91; group 3: 96; AD - group 1: 63; group 2: 62; group 3: 77). Cutoff scores for the three education groups were 79, 80 and 90, respectively. SE and SP varied among the groups (group 1: 88.1% and 83.5%; group 2: 84.6% and 96%; group 3: 70.8% and 90%). Conclusion: The CAMCOG can be used as a cognitive test for patients with low educational level with good accuracy. Patients with higher education showed lower scores than previously reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the challenges in screening for dementia in developing countries is related to performance differences due to educational and cultural factors. This study evaluated the accuracy of single screening tests as well as combined protocols including the Mini-Mental State Examination (MMSE), Verbal Fluency animal category (VF), Clock Drawing test (CDT), and Pfeffer Functional Activities Questionnaire (PFAQ) to discriminate illiterate elderly with and without Alzheimer`s disease (AD) in a clinical sample. Cross-sectional study with 66 illiterate outpatients diagnosed with mild and moderate AD and 40 illiterate normal controls. Diagnosis of AD was based on NINCDS-ADRDA. All patients were submitted to a diagnostic protocol including a clinical interview based on the CAMDEX sections. ROC curves area analyses were carried out to compare sensitivity and specificity for the cognitive tests to differentiate the two groups (each test separately and in two by two combinations). Scores for all cognitive (MMSE, CDT, VF) and functional assessments (PFAQ) were significantly different between the two groups (p < 0.001). The best screening instruments for this sample of illiterate elderly were the MMSE and the PFAQ. The cut-off scores for the MMSE, VF, CDT, and PFAQ were 17.5, 7.5, 2.5, and 11.5, respectively. The most sensitive combination came from the MMSE and PFAQ (94.1%), and the best specificity was observed with the combination of the MMSE and CDT (89%). Illiterate patients can be successfully screened for AD using well-known screening instruments, especially in combined protocols.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph. Design: Diagnostic, case-control study. Participants: One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS). Methods: All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter. Main Outcome Measures: Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%. Results: The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870). Conclusions: The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: To evaluate the cardiopulmonary effects of positive end-expiratory pressure (PEEP) equalization to intra-abdominal pressure (IAP) in an experimental model of intra-abdominal hypertension (IAH) and acute lung injury (ALI). Methods: Eight anesthetized pigs were submitted to IAH of 20 mm Hg with a carbon dioxide insufflator for 30 minutes and then submitted to lung lavage with saline and Tween (2.5%). Pressure x volume curves of the respiratory system were performed by a low flow method during IAH and ALI, and PEEP was subsequently adjusted to 27 cm center dot H(2)O for 30 minutes. Results: IAH decreases pulmonary and respiratory system static compliances and increases airway resistance, alveolar-arterial oxygen gradient, and respiratory dead space. The presence of concomitant ALI exacerbates these findings. PEEP identical to AP moderately improved oxygenation and respiratory mechanics; however, an important decline in stroke index and right ventricle ejection fraction was observed. Conclusions: Simultaneous IAH and ALI produce important impairments in the respiratory physiology. PEEP equalization to AP may improve the respiratory performance, nevertheless with a secondary hemodynamic derangement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To evaluate and compare rates of change in neuro-retinal rim area (RA) and retinal nerve fiber layer thickness (RNFLT) measurements in glaucoma patients, those with suspected glaucoma, and normal subjects observed over time. METHODS. In this observational cohort study, patients recruited from two longitudinal studies (Diagnostic Innovations in Glaucoma Study-DIGS and African Descent and Evaluation Study-ADAGES) were observed with standard achromatic perimetry (SAP), optic disc stereophotographs, confocal scanning laser ophthalmoscopy (HRT-3; Heidelberg Engineering, Heidelberg, Germany), and scanning laser polarimetry (GDx-VCC; Carl Zeiss Meditec, Inc., Dublin, CA). Glaucoma progression was determined by the Guided Progression Analysis software for standard automated perimetry [SAP] and by masked assessment of serial optic disc stereophotographs by expert graders. Random-coefficients models were used to evaluate rates of change in average RNFLT and global RA measurements and their relationship with glaucoma progression. RESULTS. At baseline, 194 (31%) eyes were glaucomatous, 347 (55%) had suspected glaucoma, and 88 (14%) were normal. Forty-six (9%) eyes showed progression by SAP and/or stereophotographs, during an average follow-up of 3.3 (+/-0.7) years. The average rate of decline for RNFLT measurements was significantly higher in the progressing group than in the non-progressing group (-0.65 vs. -0.11 mu m/y, respectively; P < 0.001), whereas RA decline was not significantly different between these groups (-0.0058 vs. -0.0073 mm(2)/y, respectively; P = 0.727). The areas under the receiver operating characteristic (ROC) curves used to discriminate progressing versus nonprogressing eyes were 0.811 and 0.507 for the rates of change in the RNFLT and RA, respectively (P < 0.001). CONCLUSIONS. The ability to discriminate eyes with progressing glaucoma by SAP and/or stereophotographs from stable eyes was significantly greater for RNFLT than for RA measurements. (Invest Ophthalmol Vis Sci. 2010;51:3531-3539) DOI: 10.1167/iovs.09-4350

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and objective The time course of cardiopulmonary alterations after pulmonary embolism has not been clearly demonstrated and nor has the role of systemic inflammation on the pathogenesis of the disease. This study aimed to evaluate over 12 h the effects of pulmonary embolism caused by polystyrene microspheres on the haemodynamics, lung mechanics and gas exchange and on interleukin-6 production. Methods Ten large white pigs (weight 35-42 kg) had arterial and pulmonary catheters inserted and pulmonary embolism was induced in five pigs by injection of polystyrene microspheres (diameter similar to 300 mu mol l(-1)) until a value of pulmonary mean arterial pressure of twice the baseline was obtained. Five other animals received only saline. Haemodynamic and respiratory data and pressure-volume curves of the respiratory system were collected. A bronchoscopy was performed before and 12 h after embolism, when the animals were euthanized. Results The embolism group developed hypoxaemia that was not corrected with high oxygen fractions, as well as higher values of dead space, airway resistance and lower respiratory compliance levels. Acute haemodynamic alterations included pulmonary arterial hypertension with preserved systemic arterial pressure and cardiac index. These derangements persisted until the end of the experiments. The plasma interleukin-6 concentrations were similar in both groups; however, an increase in core temperature and a nonsignificant higher concentration of bronchoalveolar lavage proteins were found in the embolism group. Conclusion Acute pulmonary embolism induced by polystyrene microspheres in pigs produces a 12-h lasting hypoxaemia and a high dead space associated with high airway resistance and low compliance. There were no plasma systemic markers of inflammation, but a higher central temperature and a trend towards higher bronchoalveolar lavage proteins were found. Eur J Anaesthesiol 27:67-76 (C) 2010 European Society of Anaesthesiology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the analgesic effects of unilateral repetitive transcranial magnetic stimulation (rTMS) of the motor cortex (M1) or dorsolateral prefrontal cortex (DLPFC) in two models of experimental pain in healthy volunteers. Two studies were carried out in parallel in two groups of 26 paid healthy volunteers. The effects of active or sham rTMS (frequency, 10 Hz; intensity, 80% resting motor threshold) applied to the right M1 or DLPFC were compared in a double-blind randomized cross-over design. In the first series of experiments, we analyzed the effects of rTMS on thermal (heat and cold) detection and pain thresholds measured on both hands and the left foot, by standardized quantitative sensory testing methods. In the second series of experiments, we measured the effects of M1 or DLPFC rTMS on the threshold and recruitment curves of the RIII nociceptive reflex evoked by ipsilateral electrical stimulation of the sural nerve and recorded on the biceps femoris of both lower limbs. In both studies, measurements were taken before and up to 60 min after the end of rTMS. Active rTMS of both M1 and DLPFC significantly increased the thermal pain thresholds, measured for both hands and the left foot, this effect being most marked for cold pain. These effects, which lasted at least 1 h after rTMS, were selective because they were not associated with changes in non-painful thermal sensations. By contrast, the second study showed that rTMS of M1 or DLPFC had no significant effect on the threshold or recruitment curve of the nociceptive flexion RIII reflex. Our findings demonstrate that unilateral rTMS of M1 or DLPFC induces diffuse and selective analgesic effects in healthy volunteers. The lack of effect on the RIII reflex suggests that such analgesic effects may not depend on the activation of descending inhibitory systems. (C) 2009 International Association for the Study of Pain. Published by Elsevier B. V. All rights reserved.