952 resultados para Performance Estimation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Doutor em Matemática, Estatística, pela Universidade Nova de Lisboa, faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: multimodality environment; requirement for greater understanding of the imaging technologies used, the limitations of these technologies, and how to best interpret the results; dose optimization; introduction of new techniques; current practice and best practice; incidental findings, in low-dose CT images obtained as part of the hybrid imaging process, are an increasing phenomenon with advancing CT technology; resultant ethical and medico-legal dilemmas; understanding limitations of these procedures important when reporting images and recommending follow-up; free-response observer performance study was used to evaluate lesion detection in low-dose CT images obtained during attenuation correction acquisitions for myocardial perfusion imaging, on two hybrid imaging systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To assess the impact of implementing long-stay beds for patients of low complexity and high dependency in small hospitals on the performance of an emergency referral tertiary hospital. METHODS For this longitudinal study, we identified hospitals in three municipalities of a regional department of health covered by tertiary care that supplied 10 long-stay beds each. Patients were transferred to hospitals in those municipalities based on a specific protocol. The outcome of transferred patients was obtained by daily monitoring. Confounding factors were adjusted by Cox logistic and semiparametric regression. RESULTS Between September 1, 2013 and September 30, 2014, 97 patients were transferred, 72.1% male, with a mean age of 60.5 years (SD = 1.9), for which 108 transfers were performed. Of these patients, 41.7% died, 33.3% were discharged, 15.7% returned to tertiary care, and only 9.3% tertiary remained hospitalized until the end of the analysis period. We estimated the Charlson comorbidity index – 0 (n = 28 [25.9%]), 1 (n = 31 [56.5%]) and ≥ 2 (n = 19 [17.5%]) – the only variable that increased the chance of death or return to the tertiary hospital (Odds Ratio = 2.4; 95%CI 1.3;4.4). The length of stay in long-stay beds was 4,253 patient days, which would represent 607 patients at the tertiary hospital, considering the average hospital stay of seven days. The tertiary hospital increased the number of patients treated in 50.0% for Intensive Care, 66.0% for Neurology and 9.3% in total. Patients stayed in long-stay beds mainly in the first 30 (50.0%) and 60 (75.0%) days. CONCLUSIONS Implementing long-stay beds increased the number of patients treated in tertiary care, both in general and in system bottleneck areas such as Neurology and Intensive Care. The Charlson index of comorbidity is associated with the chance of patient death or return to tertiary care, even when adjusted for possible confounding factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To analyze if size, administrative level, legal status, type of unit and educational activity influence the hospital network performance in providing services to the Brazilian Unified Health System.METHODS This cross-sectional study evaluated data from the Hospital Information System and the Cadastro Nacional de Estabelecimentos de Saúde (National Registry of Health Facilities), 2012, in Sao Paulo, Southeastern Brazil. We calculated performance indicators, such as: the ratio of hospital employees per bed; mean amount paid for admission; bed occupancy rate; average length of stay; bed turnover index and hospital mortality rate. Data were expressed as mean and standard deviation. The groups were compared using analysis of variance (ANOVA) and Bonferroni correction.RESULTS The hospital occupancy rate in small hospitals was lower than in medium, big and special-sized hospitals. Higher hospital occupancy rate and bed turnover index were observed in hospitals that include education in their activities. The hospital mortality rate was lower in specialized hospitals compared to general ones, despite their higher proportion of highly complex admissions. We found no differences between hospitals in the direct and indirect administration for most of the indicators analyzed.CONCLUSIONS The study indicated the importance of the scale effect on efficiency, and larger hospitals had a higher performance. Hospitals that include education in their activities had a higher operating performance, albeit with associated importance of using human resources and highly complex structures. Specialized hospitals had a significantly lower rate of mortality than general hospitals, indicating the positive effect of the volume of procedures and technology used on clinical outcomes. The analysis related to the administrative level and legal status did not show any significant performance differences between the categories of public hospitals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fault injection is frequently used for the verification and validation of dependable systems. When targeting real time microprocessor based systems the process becomes significantly more complex. This paper proposes two complementary solutions to improve real time fault injection campaign execution, both in terms of performance and capabilities. The methodology is based on the use of the on-chip debug mechanisms present in modern electronic devices. The main objective is the injection of faults in microprocessor memory elements with minimum delay and intrusiveness. Different configurations were implemented and compared in terms of performance gain and logic overhead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is considered that using crushed recycled concrete as aggregate for concrete production is a viable alternative to dumping and would help to conserve abiotic resources. This use has fundamentally been based on the coarse fraction because the fine fraction is likely to degrade the performance of the resulting concrete. This paper presents results from a research work undertaken at Institut Superior Tecnico (IST), Lisbon, Portugal, in which the effects of incorporating two types of superplasticizer on the mechanical performance of concrete containing fine recycled aggregate were evaluated. The purpose was to see if the addition of superplasticizer would offset the detrimental effects associated with the use of fine recycled concrete aggregate. The experimental programme is described and the results of tests for splitting tensile strength, modulus of elasticity and abrasion resistance are presented. The relative performance of concrete made with recycled aggregate was found to decrease. However, the same concrete with admixtures in general exhibited a better mechanical performance than the reference mixes without admixtures or with a less active superplasticizer. Therefore, it is argued that the mechanical performance of concrete made with fine recycled concrete aggregates can be as good as that of conventional concrete, if superplasticizers are used to reduce the water-cement ratio of the former concrete.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mg alloys can be used as bioresorsable metallic implants. However, the high corrosion rate of magnesium alloys has limited their biomedical applications. Although Mg ions are essential to the human body, an excess may cause undesirable health effects. Therefore, surface treatments are required to enhance the corrosion resistance of magnesium parts, decreasing its rate to biocompatible levels and allowing its safe application as bioresorbable metallic implants. The application of biocompatible silane coatings is envisaged as a suitable strategy for retarding the corrosion process of magnesium alloys. In the current work, a new glycidoxypropyltrimethoxysilane (GPTMS) based coating was tested on AZ31 magnesium substrates subjected to different surface conditioning procedures before coating deposition. The surface conditioning included a short etching with hydrofluoric acid (HF) or a dc polarisation in alkaline electrolyte. The silane coated samples were immersed in Hank's solution and the protective performance of the coating was studied through electrochemical impedance spectroscopy (EIS). The EIS data was treated by new equivalent circuit models and the results revealed that the surface conditioning process plays a key role in the effectiveness of the silane coating. The HF treated samples led to the highest impedance values and delayed the coating degradation, compared to the mechanically polished samples or to those submitted to dc polarisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the impact of different teachers’ approaches in using Moodle, for supporting their courses, at the Polytechnic of Porto - School of Engineering. The study covers five different courses, from different degrees and different years, and includes a number of Moodle resources especially supporting laboratory classes. These and other active resources are particularly analyzed in order to evaluate students’ adherence to them. One particular course includes a number of remote experiments, made available through VISIR (Virtual Instrument Systems in Reality) and directly accessible through links included in the Moodle course page. The collected data have been correlated with students’ classifications in the lab component and in the exam, each one weighting 50% of their final marks. This analysis benefited from the existence of different teachers’ approaches, which resulted in a diversity of Moodle-supported environments. Conclusions point to the existence of a positive correlation factor between the number of Moodle accesses and the final exam grade, although the quality of the resources made available by the teachers seems to be preponderant over its quantity. In addition, different students perspectives were found regarding active resources: while some seem to encourage students to participate (for instance online quiz or online reports), others, more demanding, are unable to stimulate the majority of them.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work extends a recent comparative study covering four different courses lectured at the Polytechnic of Porto - School of Engineering, in respect to the usage of a particular Learning Management System, i.e. Moodle, and its impact on students' results. A fifth course, which includes a number of resources especially supporting laboratory classes, is now added to the analysis. This particular course includes a number of remote experiments, made available through VISIR (Virtual Instrument Systems in Reality) and directly accessible through links included in the Moodle course page. We have analyzed the students' behavior in following these links and in effectively running experiments in VISIR (and also using other lab related resources, in Moodle). This data have been correlated with students' classifications in the lab component and in the exam, each one weighting 50% of their final marks. We aimed to compare students' performance in a richly Moodle-supported environment (with lab component) and in a poorly Moodle-supported environment (with only theoretical component). This question followed from conclusions drawn in the above referred comparative study, where it was shown that even though a positive correlation factor existed between the number of Moodle accesses and the final exam grade obtained by each student, its explanation behind was not straightforward, as the quality of the resources was preponderant over its quantity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os métodos clínicos que são realizados com recurso a tecnologias de imagiologia têm registado um aumento de popularidade nas últimas duas décadas. Os procedimentos tradicionais usados em cirurgia têm sido substituídos por métodos minimamente invasivos de forma a conseguir diminuir os custos associados e aperfeiçoar factores relacionados com a produtividade. Procedimentos clínicos modernos como a broncoscopia e a cardiologia são caracterizados por se focarem na minimização de acções invasivas, com os arcos em ‘C’ a adoptarem um papel relevante nesta área. Apesar de o arco em ‘C’ ser uma tecnologia amplamente utilizada no auxílio da navegação em intervenções minimamente invasivas, este falha na qualidade da informação fornecida ao cirurgião. A informação obtida em duas dimensões não é suficiente para proporcionar uma compreensão total da localização tridimensional da região de interesse, revelando-se como uma tarefa essencial o estabelecimento de um método que permita a aquisição de informação tridimensional. O primeiro passo para alcançar este objectivo foi dado ao definir um método que permite a estimativa da posição e orientação de um objecto em relação ao arco em ‘C’. De forma a realizar os testes com o arco em ‘C’, a geometria deste teve que ser inicialmente definida e a calibração do sistema feita. O trabalho desenvolvido e apresentado nesta tese foca-se num método que provou ser suficientemente sustentável e eficiente para se estabelecer como um ponto de partida no caminho para alcançar o objectivo principal: o desenvolvimento de uma técnica que permita o aperfeiçoamento da qualidade da informação adquirida com o arco em ‘C’ durante uma intervenção clínica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The operation of generalized Marx-type solid-state bipolar modulators is discussed and compared with simplified Marx-derived circuits, to evaluate their capability to deal with various load conditions. A comparative analysis on the number of switches per cell, fiber optic trigger count, losses, and switch hold-off voltages has been made. A circuit topology is obtained as a compromise in terms of operating performance, trigger simplicity, and switching losses. A five-stage laboratory prototype of this circuit has been assembled using 1200 V insulated gate bipolar transistors (IGBTs) and diodes, operating with 1000 V dc input voltage and 1 kHz frequency, giving 5 kV bipolar pulses, with 2.5 mu s pulse width and 5 mu s relaxation time into resistive, capacitive, and inductive loads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IEEE Electron Device Letters, VOL. 29, NO. 9,