944 resultados para Atmospheric ions
Resumo:
Although nickel is a toxic metal for living organisms in its soluble form, its importance in many biological processes recently emerged. In this view, the investigation of the nickel-dependent enzymes urease and [NiFe]-hydrogenase, especially the mechanism of nickel insertion into their active sites, represent two intriguing case studies to understand other analogous systems and therefore to lead to a comprehension of the nickel trafficking inside the cell. Moreover, these two enzymes have been demonstrated to ensure survival and colonization of the human pathogen H. pylori, the only known microorganism able to proliferate in the gastric niche. The right nickel delivering into the urease active site requires the presence of at least four accessory proteins, UreD, UreE, UreF and UreG. Similarly, analogous process is principally mediated by HypA and HypB proteins in the [NiFe]-hydrogenase system. Indeed, HpHypA and HpHypB also have been proposed to act in the activation of the urease enzyme from H. pylori, probably mobilizing nickel ions from HpHypA to the HpUreE-HpUreG complex. A complete comprehension of the interaction mechanism between the accessory proteins and the crosstalk between urease and hydrogenase accessory systems requires the determination of the role of each protein chaperone that strictly depends on their structural and biochemical properties. The availability of HpUreE, HpUreG and HpHypA proteins in a pure form is a pre-requisite to perform all the subsequent protein characterizations, thus their purification was the first aim of this work. Subsequently, the structural and biochemical properties of HpUreE were investigated using multi-angle and quasi-elastic light scattering, as well as NMR and circular dichroism spectroscopy. The thermodynamic parameters of Ni2+ and Zn2+ binding to HpUreE were principally established using isothermal titration calorimetry and the importance of key histidine residues in the process of binding metal ions was studied using site-directed mutagenesis. The molecular details of the HpUreE-HpUreG and HpUreE-HpHypA protein-protein assemblies were also elucidated. The interaction between HpUreE and HpUreG was investigated using ITC and NMR spectroscopy, and the influence of Ni2+ and Zn2+ metal ions on the stabilization of this association was established using native gel electrophoresis, light scattering and thermal denaturation scanning followed by CD spectroscopy. Preliminary HpUreE-HpHypA interaction studies were conducted using ITC. Finally, the possible structural architectures of the two protein-protein assemblies were rationalized using homology modeling and docking computational approaches. All the obtained data were interpreted in order to achieve a more exhaustive picture of the urease activation process, and the correlation with the accessory system of the hydrogenase enzyme, considering the specific role and activity of the involved protein players. A possible function for Zn2+ in the chaperone network involved in Ni2+ trafficking and urease activation is also envisaged.
Resumo:
The main objective of this thesis was the chemical characterization of synthetic secondary organic aerosol (SOA) produced from atmospherically relevant anthropogenic and biogenic VOCs during reaction chamber experiments. In parallel, the resulting chemical features of these laboratory-SOA were used to interpret the composition of ambient samples of atmospheric fine particulate matter collected at several sites in Europe, in order to determine the fraction of ambient aerosol organic mass accounted for by biogenic and anthropogenic SOA.
Resumo:
ZusammenfassungDie Analyse von Isotopenverhältnissen ist von wachsender Bedeutung bei der Untersuchung von Quellen, Senken und chemischen Reaktionswegen atmosphärischer Spurengase. Distickstoffoxid (N2O) hat vier isotopisch einfach substituierte Spezies: 14N15N16O, 15N14N16O, 14N217O und 14N218O. In der vorliegenden Arbeit wurden massenspektrometrische Methoden entwickelt, die eine komplette Charakterisierung der Variationen im Vorkommen dieser Spezies ermöglichen. Es wird die bisher umfassendste Darstellung dieser Variationen in Troposphäre und Stratosphäre gegeben und mit Bezug auf eine Reihe von Laborexperimenten detailliert interpretiert.Die Laborexperimente machen einen großen Anteil dieser Doktorarbeit aus und konzentrieren sich auf die Isotopenfraktionierung in den stratosphärischen N2O-Senken, d. h. Photolyse und Reaktion mit elektronisch angeregten Sauerstoffatomen, O(1D). Diese Prozesse sind von dominantem Einfluß auf die Isotopenzusammensetzung von atmosphärischem N2O. Potentiell wichtige Parameter wie Temperatur- und Druckvariationen, aber auch Veränderungen der Wellenlänge im Fall der Photolyse wurden berücksichtigt. Photolyse bei stratosphärisch relevanten Wellenlängen > 190 nm zeigte immer Anreicherungen von 15N in beiden Stickstoffatomen des verbleibenden N2O wie auch in 17O und 18O. Die Anreicherungen waren am mittelständigen N-Atom signifikant höher als am endständigen N (mit mittleren Werten für 18O) und stiegen zu größeren Wellenlängen und niedrigeren Temperaturen hin an. Erstmalig wurden für 18O und 15N am endständigen N-Atom Isotopenabreicherungen bei 185 nm-Photolyse festgestellt. Im Gegensatz zur Photolyse waren die Isotopenanreicherungen bei der zweiten wichtigen N2O-Senke, Reaktion mit O(1D) vergleichsweise gering. Jedoch war das positionsabhängige Fraktionierungsmuster dem der Photolyse direkt entgegengesetzt und zeigte größere Anreicherungen am endständigen N-Atom. Demgemäß führen beiden Senkenprozesse zu charakteristischen Isotopensignaturen in stratosphärischem N2O. Weitere N2O-Photolyseexperimente zeigten, daß 15N216O in der Atmosphäre höchstwahrscheinlich mit der statistisch zu erwartenden Häufigkeit vorkommt.Kleine stratosphärische Proben erforderten die Anpassung der massenspektrometrischen Methoden an Permanentflußtechniken, die auch für Messungen an Firnluftproben von zwei antarktischen Stationen verwendet wurden. Das 'Firnluftarchiv' erlaubte es, den gegenwärtigen Trend und die präindustriellen Werte der troposphärischen N2O-Isotopensignatur zu bestimmen. Ein daraus konstruiertes globales N2O-Isotopenbudget ist im Einklang mit den besten Schätzungen der Gesamt-N2O-Emissionen aus Böden und Ozeanen.17O-Messungen bestätigten die Sauerstoffisotopenanomalie in atmosphärischem N2O, zeigten aber auch, daß N2O-Photolyse die Sauerstoffisotope gemäß einem massenabhängigen Fraktionierungsgesetz anreichert. Eine troposphärische Ursache für einen Teil des Exzeß-17O wurde vorgeschlagen, basierend auf der Reaktion von NH2 mit NO2, wodurch die Sauerstoffisotopenanomalie von O3 über NO2 an N2O übertragen wird.
Resumo:
The g-factor is a constant which connects the magnetic moment $vec{mu}$ of a charged particle, of charge q and mass m, with its angular momentum $vec{J}$. Thus, the magnetic moment can be writen $ vec{mu}_J=g_Jfrac{q}{2m}vec{J}$. The g-factor for a free particle of spin s=1/2 should take the value g=2. But due to quantum electro-dynamical effects it deviates from this value by a small amount, the so called g-factor anomaly $a_e$, which is of the order of $10^{-3}$ for the free electron. This deviation is even bigger if the electron is exposed to high electric fields. Therefore highly charged ions, where electric field strength gets values on the order of $10^{13}-10^{16}$V/cm at the position of the bound electron, are an interesting field of investigations to test QED-calculations. In previous experiments [H"aff00,Ver04] using a single hydrogen-like ion confined in a Penning trap an accuracy of few parts in $10^{-9}$ was obtained. In the present work a new method for precise measurement of magnetic the electronic g-factor of hydrogen-like ions is discussed. Due to the unavoidable magnetic field inhomogeneity in a Penning trap, a very important contribution to the systematic uncertainty in the previous measurements arose from the elevated energy of the ion required for the measurement of its motional frequencies. Then it was necessary to extrapolate the result to vanishing energies. In the new method the energy in the cyclotron degree of freedom is reduced to the minimum attainable energy. This method consist in measuring the reduced cyclotron frequency $nu_{+}$ indirectly by coupling the axial to the reduced cyclotron motion by irradiation of the radio frequency $nu_{coup}=nu_{+}-nu_{ax}+delta$ where $delta$ is, in principle, an unknown detuning that can be obtained from the knowledge of the coupling process. Then the only unknown parameter is the desired value of $nu_+$. As a test, a measurement with, for simplicity, artificially increased axial energy was performed yielding the result $g_{exp}=2.000~047~020~8(24)(44)$. This is in perfect agreement with both the theoretical result $g_{theo}=2.000~047~020~2(6)$ and the previous experimental result $g_{exp1}=2.000~047~025~4(15)(44).$ In the experimental results the second error-bar is due to the uncertainty in the accepted value for the electron's mass. Thus, with the new method a higher accuracy in the g-factor could lead by comparison to the theoretical value to an improved value of the electron's mass. [H"af00] H. H"affner et al., Phys. Rev. Lett. 85 (2000) 5308 [Ver04] J. Verd'u et al., Phys. Rev. Lett. 92 (2004) 093002-1
Resumo:
Global observations of the chemical composition of the atmosphere are essential for understanding and studying the present and future state of the earth's atmosphere. However, by analyzing field experiments the consideration of the atmospheric motion is indispensable, because transport enables different chemical species, with different local natural and anthropogenic sources, to interact chemically and so consequently influences the chemical composition of the atmosphere. The distance over which that transport occurs is highly dependent upon meteorological conditions (e.g., wind speed, precipitation) and the properties of chemical species itself (e.g., solubility, reactivity). This interaction between chemistry and dynamics makes the study of atmospheric chemistry both difficult and challenging, and also demonstrates the relevance of including the atmospheric motions in that context. In this doctoral thesis the large-scale transport of air over the eastern Mediterranean region during summer 2001, with a focus on August during the Mediterranean Intensive Oxidant Study (MINOS) measurement campaign, was investigated from a lagrangian perspective. Analysis of back trajectories demonstrated transport of polluted air masses from western and eastern Europe in the boundary layer, from the North Atlantic/North American area in the middle end upper troposphere and additionally from South Asia in the upper troposphere towards the eastern Mediterranean. Investigation of air mass transport near the tropopause indicated enhanced cross-tropopause transport relative to the surrounding area over the eastern Mediterranean region in summer. A large band of air mass transport across the dynamical tropopause develops in June, and is shifted toward higher latitudes in July and August. This shifting is associated with the development and the intensification of the Arabian and South Asian upper-level anticyclones and consequential with areas of maximum clear-air turbulence, hypothesizing quasi-permanent areas with turbulent mixing of tropospheric and stratospheric air during summer over the eastern Mediterranean as a result of large-scale synoptic circulation. In context with the latex knowledge about the transport of polluted air masses towards the Mediterranean and with increasing emissions, especially in developing countries like India, this likely gains in importance.
Resumo:
X-ray laser fluorescence spectroscopy of the 2s-2p transition in Li-like ions is promising to become a widely applicable tool to provide information on the nuclear charge radii of stable and radioactive isotopes. For performing such experiments at the Experimental Storage Ring ESR, and the future NESR within the FAIR Project, a grazing incidence pumped (GRIP) x-ray laser (XRL) was set up at GSI Darmstadt using PHELIX (Petawatt High Energy Laser for heavy Ions eXperiments). The experiments demonstrated that lasing using the GRIP geometry could be achieved with relatively low pump energy, a prerequisite for higher repetition rate. In the first chapter the need of a plasma XRL is motivated and a short history of the plasma XRL is presented. The distinctive characteristic of the GRIP method is the controlled deposition of the pump laser energy into the desired plasma density region. While up to now the analysis performed were mostly concerned with the plasma density at the turning point of the main pump pulse, in this thesis it is demonstrated that also the energy deposition is significantly modified for the GRIP method, being sensitive in different ways to a large number of parameters. In the second chapter, the theoretical description of the plasma evolution, active medium and XRL emission properties are reviewed. In addition an innovative analysis of the laser absorption in plasma which includes an inverse Bremsstrahlung (IB) correction factor is presented. The third chapter gives an overview of the experimental set-up and diagnostics, providing an analytical formula for the average and instantaneous traveling wave speed generated with a tilted, on-axis spherical mirror, the only focusing system used up to now in GRIP XRL. The fourth chapter describes the experimental optimization and results. The emphasis is on the effect of the incidence angle of the main pump pulse on the absorption in plasma and on output and gain in different lasing lines. This is compared to the theoretical results for two different incidence angles. Significant corrections for the temperature evolution during the main pump pulse due to the incidence angle are demonstrated in comparison to a simple analytical model which does not take into account the pumping geometry. A much better agreement is reached by the model developed in this thesis. An interesting result is also the appearance of a central dip in the spatially resolved keV emission which was observed in the XRL experiments for the first time and correlates well with previous near field imaging and plasma density profile measurements. In the conclusion also an outlook to the generation of shorter wavelength XRL’s is given.
Resumo:
The objective of the work is the evaluation of the potential capabilities of navigation satellite signals to retrieve basic atmospheric parameters. A capillary study have been performed on the assumptions more or less explicitly contained in the common processing steps of navigation signals. A probabilistic procedure has been designed for measuring vertical discretised profiles of pressure, temperature and water vapour and their associated errors. Numerical experiments on a synthetic dataset have been performed with the main objective of quantifying the information that could be gained from such approach, using entropy and relative entropy as testing parameters. A simulator of phase delay and bending of a GNSS signal travelling across the atmosphere has been developed to this aim.
Resumo:
The atmospheric muon charge ratio, defined as the number of positive over negative charged muons, is an interesting quantity for the study of high energy hadronic interactions in atmosphere and the nature of the primary cosmic rays. The measurement of the charge ratio in the TeV muon energy range allows to study the hadronic interactions in kinematic regions not yet explored at accelerators. The OPERA experiment is a hybrid electronic detector/emulsion apparatus, located in the underground Gran Sasso Laboratory, at an average depth of 3800 meters water equivalent (m.w.e.). OPERA is the first large magnetized detector that can measure the muon charge ratio at the LNGS depth, with a wide acceptance for cosmic ray muons coming from above. In this thesis, the muon charge ratio is measured using the spectrometers of the OPERA detector in the highest energy region. The charge ratio was computed separately for single and for multiple muon events, in order to select different primary cosmic ray samples in energy and composition. The measurement as a function of the surface muon energy is used to infer parameters characterizing the particle production in atmosphere, that will be used to constrain Monte Carlo predictions. Finally, the experimental results are interpreted in terms of cosmic ray and particle physics models.
Resumo:
Ein neu entwickeltes globales Atmosphärenchemie- und Zirkulationsmodell (ECHAM5/MESSy1) wurde verwendet um die Chemie und den Transport von Ozonvorläufersubstanzen zu untersuchen, mit dem Schwerpunkt auf Nichtmethankohlenwasserstoffen. Zu diesem Zweck wurde das Modell durch den Vergleich der Ergebnisse mit Messungen verschiedenen Ursprungs umfangreich evaluiert. Die Analyse zeigt, daß das Modell die Verteilung von Ozon realistisch vorhersagt, und zwar sowohl die Menge als auch den Jahresgang. An der Tropopause gibt das Modell den Austausch zwischen Stratosphäre und Troposphäre ohne vorgeschriebene Flüsse oder Konzentrationen richtig wieder. Das Modell simuliert die Ozonvorläufersubstanzen mit verschiedener Qualität im Vergleich zu den Messungen. Obwohl die Alkane vom Modell gut wiedergeben werden, ergibt sich einige Abweichungen für die Alkene. Von den oxidierten Substanzen wird Formaldehyd (HCHO) richtig wiedergegeben, während die Korrelationen zwischen Beobachtungen und Modellergebnissen für Methanol (CH3OH) und Aceton (CH3COCH3) weitaus schlechter ausfallen. Um die Qualität des Modells im Bezug auf oxidierte Substanzen zu verbessern, wurden einige Sensitivitätsstudien durchgeführt. Diese Substanzen werden durch Emissionen/Deposition von/in den Ozean beeinflußt, und die Kenntnis über den Gasaustausch mit dem Ozean ist mit großen Unsicherheiten behaftet. Um die Ergebnisse des Modells ECHAM5/MESSy1 zu verbessern wurde das neue Submodell AIRSEA entwickelt und in die MESSy-Struktur integriert. Dieses Submodell berücksichtigt den Gasaustausch zwischen Ozean und Atmosphäre einschließlich der oxidierten Substanzen. AIRSEA, welches Informationen über die Flüssigphasenkonzentration des Gases im Oberflächenwasser des Ozeans benötigt wurde ausgiebig getestet. Die Anwendung des neuen Submodells verbessert geringfügig die Modellergebnisse für Aceton und Methanol, obwohl die Verwendung einer vorgeschriebenen Flüssigphasenkonzentration stark den Erfolg der Methode einschränkt, da Meßergebnisse nicht in ausreichendem Maße zu Verfügung stehen. Diese Arbeit vermittelt neue Einsichten über organische Substanzen. Sie stellt die Wichtigkeit der Kopplung zwischen Ozean und Atmosphäre für die Budgets vieler Gase heraus.
Resumo:
Das Time-of-Flight Aerosol Mass Spectrometer (ToF-AMS) der Firma Aerodyne ist eine Weiterentwicklung des Aerodyne Aerosolmassenspektrometers (Q-AMS). Dieses ist gut charakterisiert und kommt weltweit zum Einsatz. Beide Instrumente nutzen eine aerodynamische Linse, aerodynamische Partikelgrößenbestimmung, thermische Verdampfung und Elektronenstoß-Ionisation. Im Gegensatz zum Q-AMS, wo ein Quadrupolmassenspektrometer zur Analyse der Ionen verwendet wird, kommt beim ToF-AMS ein Flugzeit-Massenspektrometer zum Einsatz. In der vorliegenden Arbeit wird anhand von Laborexperimenten und Feldmesskampagnen gezeigt, dass das ToF-AMS zur quantitativen Messung der chemischen Zusammensetzung von Aerosolpartikeln mit hoher Zeit- und Größenauflösung geeignet ist. Zusätzlich wird ein vollständiges Schema zur ToF-AMS Datenanalyse vorgestellt, dass entwickelt wurde, um quantitative und sinnvolle Ergebnisse aus den aufgenommenen Rohdaten, sowohl von Messkampagnen als auch von Laborexperimenten, zu erhalten. Dieses Schema basiert auf den Charakterisierungsexperimenten, die im Rahmen dieser Arbeit durchgeführt wurden. Es beinhaltet Korrekturen, die angebracht werden müssen, und Kalibrationen, die durchgeführt werden müssen, um zuverlässige Ergebnisse aus den Rohdaten zu extrahieren. Beträchtliche Arbeit wurde außerdem in die Entwicklung eines zuverlässigen und benutzerfreundlichen Datenanalyseprogramms investiert. Dieses Programm kann zur automatischen und systematischen ToF-AMS Datenanalyse und –korrektur genutzt werden.
Resumo:
Im Rahmen der Arbeit wurde ein neuartiges Aerosol-Ionenfallen-Massenspektrometer (AIMS) aufgebaut und umfassend charakterisiert. Mit dem AIMS kann die chemische Zusammensetzung der verdampfbaren Komponente (bei etwa 600 °C) von Aerosolpartikeln quantitativ und on-line bestimmt werden. Die Durchmesser der Teilchen, die analysiert werden können, liegen zwischen etwa 30 und 500 nm. Der experimentelle Aufbau greift auf ein bereits gut charakterisiertes Einlasssystem des Aerodyne Aerosol-Massenspektrometers (AMS) zurück, das einen Partikeleinlass, bestehend aus einer kritischen Düse und einer aerodynamischen Linse, einen Verdampfer für die Aerosolteilchen und eine Elektronenstoß-Ionenquelle enthält. Das kommerzielle AMS verwendet entweder ein lineares Quadrupol-Massenfilter (Q-AMS) oder ein Flugzeit-Massenspektrometer (ToF-AMS). Im AIMS hingegen wird eine dreidimensionale Ionenfalle als Massenanalysator eingesetzt. Dadurch eröffnen sich unter anderem Möglichkeiten zur Durchführung von MSn-Studien und Ionen/Molekül-Reaktionsstudien. Das Massenspektrometer und wichtige Teile der Steuerungselektronik wurden am Max-Planck-Institut für Chemie in Mainz entworfen und hergestellt. Das AIMS wird von einem PC und einer Software, die in der Programmiersprache LabVIEW verfasst ist, gesteuert. Aufgrund seiner Kompaktheit ist das Instrument auch für den Feldeinsatz geeignet. Mit der Software Simion 7.0 wurden umfangreiche Simulationsstudien durchgeführt. Diese Studien beinhalten Simulationen zur Ermittlung der optimalen Spannungseinstellungen für den Ionentransfer von der Ionenquelle in die Ionenfalle und eine Abschätzung der Sammeleffizienz der Ionenfalle, die gut mit einem gemessenen Wert übereinstimmt. Charakterisierungsstudien zeigen einige instrumentelle Merkmale des AIMS auf. Es wurde beispielsweise ein Massenauflösungsvermögen von 807 für m/z 121 gefunden, wenn eine Analyserate von 1780 amu/s verwendet wird. Wird die Analyserate verringert, dann lässt sich das Massenauflösungsvermögen noch erheblich steigern. Bei m/z 43 kann dann ein Wert von > 1500 erzielt werden, wodurch sich Ionenfragmente wie C2H3O+ (m/z 43.0184) und C3H7+ (m/z 43.0548) voneinander trennen lassen. Der Massenbereich des AIMS lässt sich durch resonante Anregung erweitern; dies wurde bis zu einer Masse von 1000 amu getestet. Kalibrationsmessungen mit laborgenerierten Partikeln zeigen eine hervorragende Linearität zwischen gemessenen Signalstärken und erzeugten Aerosol-Massenkonzentrationen. Diese Studien belegen im Zusammenhang mit den gefundenen Nachweisgrenzen von Nitrat (0.16 μg/m³) und Sulfat (0.65 μg/m³) aus Aerosolpartikeln, dass das AIMS für quantitative Messungen von atmosphärischem Aerosol geeignet ist. Ein Vergleich zwischen dem AIMS und dem Q-AMS für Nitrat in städtischem Aerosol zeigt eine gute Übereinstimmung der gefundenen Messwerte. Für laborgenerierte Polystyren-Latexpartikel wurde eine MS/MS-Studie unter der Anwendung von collision induced dissociation (CID) durchgeführt. Das Verhältnis von Fragmentionen zu Analytionen wurde zu einem Wert von > 60% bestimmt. In der Zukunft können ähnliche MS/MS-Studien auch für atmosphärische Aerosolpartikel angewandt werden, wodurch sich neue Perspektiven für die Speziation von Aerosolbestandteilen eröffnen. Dann sollen vor allem Kondensationsprozesse, das heißt die Bildung von sekundärem Aerosol, detailliert untersucht werden.
Resumo:
Das Aerosolmassenspektrometer SPLAT (Single Particle Laser Ablation Time-of-Flight Mass Spectrometer) ist in der Lage, die Größe einzelner Aerosolpartikel in einem Größenbereich von 0,3 µm bis 3 µm zu bestimmen und gleichzeitig chemisch zu analysieren. Die Größenbestimmung erfolgt durch Streulichtmessung und Bestimmung der Flugzeit der Partikel zwischen zwei kontinuierlichen Laserstrahlen. Durch Kalibrationsmessungen kann auf den aerodynamischen Durchmesser der Partikel geschlossen werden. Kurzzeitig nach der Streulichtdetektion werden die Partikel durch einen hochenergetischen gepulsten UV-Laser verdampft und ionisiert. Die Flugzeit der Partikel zwischen den kontinuierlichen Laserstrahlen wird dazu benutzt, die Ankunftszeit der Partikel in der Ionenquelle zu berechnen und den UV-Laserpuls zu zünden. Die entstandenen Ionen werden in einem bipolaren Flugzeitmassen¬spektrometer nachgewiesen. Durch die Laserablation/Ionisation ist das SPLAT in der Lage, auch schwer verdampfbare Komponenten des atmosphärischen Aerosols - wie etwa Minerale oder Metalle - nachzuweisen. Das SPLAT wurde während dieser Arbeit vollständig neu entwickelt und aufgebaut. Dazu gehörten das Vakuum- und Einlasssystem, die Partikeldetektion, die Ionenquelle und das Massen-spektrometer. Beim Design des SPLAT wurde vor allem auf den späteren Feldeinsatz Wert gelegt, was besondere Anforderungen an Mechanik und Elektronik stellte. Die Charakterisierung der einzelnen Komponenten sowie des gesamten Instruments wurde unter Laborbedingungen durchgeführt. Dabei wurde u.a. Detektionseffizienzen des Instruments ermittelt, die abhängig von der Größe der Partikel sind. Bei sphärischen Partikeln mit einem Durchmesser von 600 nm wurden ca. 2 % der Partikel die in das Instrument gelangten, detektiert und chemisch analysiert. Die Fähigkeit zum Feldeinsatz hat das SPLAT im Februar/März 2006 während einer internationalen Messkampagne auf dem Jungfraujoch in der Schweiz bewiesen. Auf dieser hochalpinen Forschungsstation in einer Höhe von ca. 3580 m fand das SPLAT mineralische und metallische Komponenten in den Aerosolpartikeln. Das SPLAT ist ein vielfältig einsetzbares Instrument und erlaubt vor allem in Kombination mit Aerosolmassenspektrometern, die mit thermischer Verdampfung und Elektronenstoßionisation arbeiten, einen Erkenntnisgewinn in der Analytik atmosphärischer Aerosolpartikel.
Resumo:
Recent developments in the theory of plasma-based collisionally excited x-ray lasers (XRL) have shown an optimization potential based on the dependence of the absorption region of the pumping laser on its angle of incidence on the plasma. For the experimental proof of this idea, a number of diagnostic schemes were developed, tested, qualified and applied. A high-resolution imaging system, yielding the keV emission profile perpendicular to the target surface, provided positions of the hottest plasma regions, interesting for the benchmarking of plasma simulation codes. The implementation of a highly efficient spectrometer for the plasma emission made it possible to gain information about the abundance of the ionization states necessary for the laser action in the plasma. The intensity distribution and deflection angle of the pump laser beam could be imaged for single XRL shots, giving access to its refraction process within the plasma. During a European collaboration campaign at the Lund Laser Center, Sweden, the optimization of the pumping laser incidence angle resulted in a reduction of the required pumping energy for a Ni-like Mo XRL, which enabled the operation at a repetition rate of 10 Hz. Using the experiences gained there, the XRL performance at the PHELIX facility, GSI Darmstadt with respect to achievable repetition rate and at wavelengths below 20 nm was significantly improved, and also important information for the development towards multi-100 eV plasma XRLs was acquired. Due to the setup improvements achieved during the work for this thesis, the PHELIX XRL system now has reached a degree of reproducibility and versatility which is sufficient for demanding applications like the XRL spectroscopy of heavy ions. In addition, a European research campaign, aiming towards plasma XRLs approaching the water-window (wavelengths below 5 nm) was initiated.
Resumo:
Die beiden in dieser Arbeit betrachteten Systeme, wässrige Lösungen von Ionen und ionische Flüssigkeiten, zeigen vielfältige Eigenschaften und Anwendungsmöglichkeiten, im Gegensatz zu anderen Systemen. Man findet sie beinahe überall im normalen Leben (Wasser), oder ihre Bedeutung wächst (ioinische Flüssigkeiten). Der elektronische Anteil und der atomare Anteil wurden getrennt voneinander untersucht und im Zusammenhang analysiert. Mittels dieser Methode konnten die in dem jeweiligen System auftretenden Mechanismen genauer untersucht werden. Diese Methode wird "Multiscale Modeling" genannt, dabei werden die Untereinheiten eines Systems genauer betrachtet, wie in diesem Fall die elektronischen and atomaren Teilsystem. Die Ergebnisse, die aus den jeweiligen Betrachtungen hervorgehen, zeigen, dass, im Falle von hydratisierten Ionen die Wasser-Wasser Wechselwirkungen wesentlich stärker sind als die elektrostatischen Wechselwirkung zwischen Wasser und dem Ion. Anhand der Ergebnisse ergibt sich, dass normale nicht-polarisierbare Modelle ausreichen, um Ionen-Wasser Lösungen zu beschreiben. Im Falle der ionischen Flüssigkeiten betrachten wir die elektronische Ebene mittels sehr genauer post-Hartree-Fock Methoden und DFT, deren Ergebnisse dann mit denen auf molekularer Ebene (mithilfe von CPMD/klassischer MD) in Beziehung gesetzt werden. Die bisherigen Ergebnisse zeigen, dass die Wasserstoff-Brückenbindungen im Fall der ionischen Flüssigkeiten nicht vernachässigt werden können. Weiterhin hat diese Studie herausgefunden, dass die klassischen Kraftfelder die Elektrostatik (Dipol- und Quadrupolmomente) nicht genau genug beschreibt. Die Kombination des mikroskopischen Mechanismus und der molekularen Eigenschaften ist besonders sinnvoll um verschiedene Anhaltspunkte von Simualtionen (z.B. mit klassische Molekular-Dynamik) oder Experimenten zu liefern oder solche zu erklären.
Resumo:
Atmospheric aerosol particles directly impact air quality and participate in controlling the climate system. Organic Aerosol (OA) in general accounts for a large fraction (10–90%) of the global submicron (PM1) particulate mass. Chemometric methods for source identification are used in many disciplines, but methods relying on the analysis of NMR datasets are rarely used in atmospheric sciences. This thesis provides an original application of NMR-based chemometric methods to atmospheric OA source apportionment. The method was tested on chemical composition databases obtained from samples collected at different environments in Europe, hence exploring the impact of a great diversity of natural and anthropogenic sources. We focused on sources of water-soluble OA (WSOA), for which NMR analysis provides substantial advantages compared to alternative methods. Different factor analysis techniques are applied independently to NMR datasets from nine field campaigns of the project EUCAARI and allowed the identification of recurrent source contributions to WSOA in European background troposphere: 1) Marine SOA; 2) Aliphatic amines from ground sources (agricultural activities, etc.); 3) Biomass burning POA; 4) Biogenic SOA from terpene oxidation; 5) “Aged” SOAs, including humic-like substances (HULIS); 6) Other factors possibly including contributions from Primary Biological Aerosol Particles, and products of cooking activities. Biomass burning POA accounted for more than 50% of WSOC in winter months. Aged SOA associated with HULIS was predominant (> 75%) during the spring-summer, suggesting that secondary sources and transboundary transport become more important in spring and summer. Complex aerosol measurements carried out, involving several foreign research groups, provided the opportunity to compare source apportionment results obtained by NMR analysis with those provided by more widespread Aerodyne aerosol mass spectrometers (AMS) techniques that now provided categorization schemes of OA which are becoming a standard for atmospheric chemists. Results emerging from this thesis partly confirm AMS classification and partly challenge it.