952 resultados para vacuum-pump


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calcium uptake by tonoplast enriched membrane vesicles from maize (Zea mays L. cv. LG 11) primary roots was studied. A pH gradient, measured by the fluorescence quenching of quinacrine, was generated across sealed vesicles driven by the pyrophosphate-dependent proton pump. The fluorescence quenching was strongly inhibited by Ca2+; moreover, when increasing Ca2+ concentrations were added to vesicles at steady-state, a concomitant decrease in the proton gradient was observed. Ca2+ uptake using Ca-45(2+) was linear from 10 min when oxalate (10 mM) was present, while Ca2+ uptake was completely inhibited with proton ionophores (FCCP and monensin), indicating a Ca2+/H+ antiport. Membranes were further fractionated using a linear sucrose density gradient (10-45%) and were identified with marker enzymes. Ca2+ uptake co-migrated with the tonoplast pyrophosphate-dependent proton pumping, pyrophosphatase and ATPase activities: the Ca2+/H+ antiport is consequently located at the tonoplast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The subcellular localization of a calmodulin-stimulated calcium (Ca2+)-ATPase activity from maize roots (Zea mays L., cv LG 11) was studied. For this purpose, an efficient procedure was developed to prepare sealed plasma membrane vesicles allowing the measurement of proton and Ca2+ transport activities. Two-day-old root membranes were fractionated by sucrose and dextran density gradient centrifugation. Marker enzymes were used to study the distribution of the different membranes in the gradients and a filtration technique was developed to measure Ca-45(2+) transport in sealed vesicles. Most of the ATP-dependent Ca2+ transport activity was associated with the ER. However, a small part of this activity was associated with the tonoplast (corresponding to the activity of the H+/Ca2+ antiport) and the plasma membrane. When the Ca2+ transport was measured in the presence of exogenous calmodulin (1 muM), a 3-5-fold increase of uptake was measured. The calmodulin-stimulated activity was associated with the tonoplast vesicles only. This activity was insensitive to monensin, a proton ionophore, ruling out a direct effect of calmodulin on the H+/Ca2+ antiport. In conclusion, four different Ca2+ transporters are present in young maize root cells. A Ca2+/H+ antiport system is present on the tonoplast, whereas, the plasma membrane and the ER possess each a calmodulinin-sensitive Ca2+-ATPase. Finally, a calmodulin-stimulated Ca2+-ATPase is associated with the tonoplast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hydrolytic subunit of the H+-translocating inorganic pyrophosphatase (V-PPase EC 3.6.1.1.) prepared from Rubus hispidus cell cultures has been purified from tonoplast-enriched membranes and analysed by SDS-polyacrylamide gel electrophoresis, Only one polypeptide of M(r) 70 000 was recovered with the V-PPase activity after solubilization in the presence of Triton X-100, purification by gel filtration (Superose) and anion exchange (Mono Q) chromatography. This polypeptide strongly cross-reacted with an antibody raised against the V-PPase from Vigna radiata. The tonoplast-enriched fraction was also used to solubilize and reconstitute the-V-PPase. The proteoliposomes showing a PPi-dependent proton transport activity were purified by gel filtration (Superose) and analysed by SDS-polyacrylamide gel electrophoresis. Only one polypeptide of M(r) 70 000 was recovered with the proton-pumping activity. All these data suggest that the native V-PPase from Rubus is composed of a single kind of polypeptide with an M(r) of 70 000 and representing the catalytic subunit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiopulmonary bypass (CPB) with aortic cross-clamping and cardioplegic arrest remains the method of choice for patients requiring standard myocardial revascularization. Therefore, very high-risk patients presenting with acute coronary syndrome, unstable angina, onset of cardiac decompensation and requiring emergency multiple myocardial revascularization, can have a poor outcome. The on-pump beating heart technique can reduce the mortality and the morbidity in such a selected group of patients and this report describes our clinical experience. METHODS: Out of 290 patients operated for CABG from January 2005 to January 2006, 25 (8.6%) selected high-risk patients suffering from life threatening coronary syndrome (mean age 69 +/- 7 years) and requiring emergency multiple myocardial revascularization, underwent on-pump beating heart surgery. The mean pre-operative left ventricle ejection fraction (LVEF) was 27 +/- 8%. The majority of them (88%) suffered of tri-vessel coronary disease and 6 (24%) had a left main stump disease. Nine patients (35%) were on severe cardiac failure and seven among them (28%) received a pre-operative intra-aortic balloon pump. The pre-operative EuroScore rate was equal or above 8 in 18 patients (73%). RESULTS: All patients underwent on-pump-beating heart coronary revascularization. The mean number of graft/patient was 2.9 +/- 0.6 and the internal mammary artery was used in 23 patients (92%). The mean CPB time was 84 +/- 19 minutes. Two patients died during the recovery stay in the intensive care unit, and there were no postoperative myocardial infarctions between the survivors. Eight patients suffered of transitorily renal failure and 1 patient developed a sternal wound infection. The mean hospital stay was 12 +/- 7 days. The follow-up was complete for all 23 patients survived at surgery and the mean follow-up time was 14 +/- 5 months. One patient died during the follow-up for cardiac arrest and 2 patients required an implantable cardiac defibrillator. One year after surgery they all had a standard trans-thoracic echocardiogram showing a mean LVEF rate of 36 +/- 11.8%. CONCLUSION: Standard on-pump arrested heart coronary surgery has higher mortality and morbidity in emergencies. The on-pump beating heart myocardial revascularization seems to be a valid alternative for the restricted and selected cohort of patients suffering from life threatening coronary syndrome and requiring multiple emergency CABG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Off-pump trans left ventricular approach provides more precise deployment of stented aortic valve of any size with respect to the endovascular replacement. One of the key steps of this procedure is the ventricle repair after catheter withdrawing. We designed an animal study to compare the consistency of a sutureless repair of the left ventricle access using nitinol occluder with and without pericardial cuff on the ventricular side. METHODS: Material description: The Amplatz-nitinol occluder consists of two square heads squeezing ventricle wall in between them, sealing the defect. To improve its sealing property, a pericardial patch was sutured to the ventricular head of the occluder. Animal study setup: In adult pigs, a 30F sheath was inserted into the epigastric area through the cardiac apex, up to the left ventricle, simulating the approach for off-pump aortic valve replacement. The sheath was then removed and the ventricle closed with standard occluder in half of the animals, and cuffed occluder in the other half. Animals were followed-up for 3h, collecting haemodynamics data and pericardial bleeding. RESULTS: Device was successfully deployed in 12 animals in less than 1min. In the group where the standard occluder was used, bleeding during the deployment was 80+/-20ml and after the deployment was 800+/-20ml over 3h. In the group where the cuffed occluder was used, bleeding during the deployment was 85+/-20ml and after the deployment was 100+/-5ml over 3h. In the cuffed group, bleeding was significantly lower than the standard group, p-value being <0.001. CONCLUSIONS: The occluder is easy to use and the pericardial cuff dramatically increases its efficacy as demonstrated by a significant reduction of blood loss. The cuffed occluder opens the way for endoscopic, off-pump, transventricular aortic valve replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The efficiency of co-expression and linkage of distinct T-DNAs present in separate Agrobacterium tumefaciens was analysed in Arabidopsis thaliana transformed by the vacuum infiltration method. Co-expression was monitored by the synthesis of three bacterial proteins involved in the production of polyhydroxybutyrate (PHB) in the plastids. Out of 80 kanamycin-resistant transgenic plants analysed, 13 plants were co-transformed with the two distinct T-DNAs and produced PHB. Of those, 7 lines had a kanamycin-resistance segregation ratio consistent with the presence of a single functional insert. Genetic linkage between the distinct T-DNAs was demonstrated for all 13 PHB-producing lines, while physical linkage between the distinct T-DNAs was shown for 12 out of 13 lines. T-DNAs were frequently linked in an inverted orientation about the left borders. Transformation of A. thaliana by the co-infiltration of two A. tumefaciens containing distinct T-DNAs is, thus, an efficient approach for the integration and expression of several transgenes at a single locus. This approach will facilitate the creation and study of novel metabolic pathways requiring the expression of numerous transgenes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. This study is an evaluation of the vacuum-assisted closure (VAC) therapy for the treatment of severe intrathoracic infections complicating lung resection, esophageal surgery, viscera perforation, or necrotizing pleuropulmonary infections.Methods. We reviewed the medical records of all patients treated by intrathoracic VAC therapy between January 2005 and December 2008. All patients underwent surgical debridement-decortication and control of the underlying cause of infection such as treatment of bronchus stump insufficiency, resection of necrotic lung, or closure of esophageal or intestinal leaks. Surgery was followed by intrathoracic VAC therapy until the infection was controlled. The VAC dressings were changed under general anesthesia and the chest wall was temporarily closed after each dressing change. All patients received systemic antibiotic therapy.Results. Twenty-seven patients (15 male, median age 64 years) underwent intrathoracic VAC dressings for the management of postresectional empyema (n = 8) with and without bronchopleural fistula, necrotizing infections (n = 7), and intrathoracic gastrointestinal leaks (n = 12). The median length of VAC therapy was 22 days (range 5 to 66) and the median number of VAC changes per patient was 6 (range 2 to 16). In-hospital mortality was 19% (n = 5) and was not related to VAC therapy or intrathoracic infection. Control of intrathoracic infection and closure of the chest cavity was achieved in all surviving patients.Conclusions. Vacuum-assisted closure therapy is an efficient and safe adjunct to treat severe intrathoracic infections and may be a good alternative to the open window thoracostomy in selected patients. Long time intervals in between VAC changes and short course of therapy result in good patient acceptance. (Ann Thorac Surg 2011;91:1582-90) (C) 2011 by The Society of Thoracic Surgeons

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative research that aimed to identify the mean total cost (MTC) of connecting, maintaining and disconnecting patient-controlled analgesia pump (PCA) in the management of pain. The non-probabilistic sample corresponded to the observation of 81 procedures in 17 units of the Central Institute of the Clinics Hospital, Faculty of Medicine, University of Sao Paulo. We calculated the MTC multiplying by the time spent by nurses at a unit cost of direct labor, adding the cost of materials and medications/solutions. The MTC of connecting was R$ 107.91; maintenance R$ 110.55 and disconnecting R$ 4.94. The results found will subsidize discussions about the need to transfer money from the Unified Health System to hospitals units that perform this technique of analgesic therapy and it will contribute to the cost management aimed at making efficient and effective decision-making in the allocation of available resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although gravity drainage has been the standard technique for cardiopulmonary bypass (CPB), the development of min imally invasive techniques for cardiac surgery has renewed interest in using vacuum assisted venous drainage (VAVD) Dideco (Mirandola, Italy) has modified the D903 Avant oxygenator to apply a vacuum to its venous reservoir. The impact of VAVD on blood damage with this device is analyzed. Six calves (mean body weight, 71.3 +/- 4.1 kg) were con nected to CPB by jugular venous and carotid arterial cannu lation, with a flow rate of 4-4.51 L/min for 6 h. They were assigned to gravity drainage (standard D903 Avant oxygen ator, n = 3) or VAVD (modified D903 Avant oxygenator, n = 3). The animals were allowed to survive for 7 days. A standard battery of blood samples was taken before bypass, throughout bypass, and 24 h, 48 h, and 7 days after bypass. Analysis of variance was used for repeated measurements. Thrombocyte and white blood cell counts, corrected by hematocrit and normalized by prebypass values, were not significantly different between groups throughout all study periods. The same holds true for hemolytic parameters (lactate dehydrogenase [LDH] and plasma hemoglobin). Both peaked at 24 hr in the standard and VAVD groups: LDH, 2,845 +/- 974 IU/L vs. 2,537 +/- 476 IU/L (p = 0.65), respectively; and plasma hemoglobin, 115 +/- 31 mg/L vs. 89 +/- 455 mg/L (p = 0.45), respectively. In this experimental setup with prolonged perfusion time, VAVD does not increase trauma to blood cells in comparison with standard gravity drainage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Vacuum-assisted closure (VAC) has become the preferred modality to treat many complex wounds but could be further improved by methods that minimize bleeding and facilitate wound epithelialization. Short fiber poly-N-acetyl glucosamine nanofibers (sNAG) are effective hemostatic agents that activate platelets and facilitate wound epithelialization. We hypothesized that sNAG used in combination with the VAC device could be synergistic in promoting wound healing while minimizing the risk of bleeding. METHODS: Membranes consisting entirely of sNAG nanofibers were applied immediately to dorsal excisional wounds of db/db mice followed by application of the VAC device. Wound healing kinetics, angiogenesis, and wound-related growth factor expression were measured. RESULTS: The application of sNAG membranes to wounds 24 hours before application of the VAC device was associated with a significant activation of wounds (expression of PDGF, TGFβ, EGF), superior granulation tissue formation rich in Collagen I as well as superior wound epithelialization (8.6% ± 0.3% vs. 1.8% ± 1.1% of initial wound size) and wound contraction. CONCLUSIONS: The application of sNAG fiber-containing membranes before the application of the polyurethane foam interface of VAC devices leads to superior healing in db/db mice and represents a promising wound healing adjunct that can also reduce the risk of bleeding complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent improvements in the determination of the running of the fine-structure constant also allow an update of the hadronic vacuum-polarization contribution to the Lamb shift. We find a shift of -3.40(7) kHz to the 1S level of hydrogen. We also comment on the contribution of this effect to the determination by elastic electron scattering of the rms radii of nuclei.