99 resultados para sensorineural


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sensorineural hearing loss (SNHL) is the most common sequel of bacterial meningitis (BM) and is observed in up to 30% of survivors when the disease is caused by Streptococcus pneumoniae. BM is the single most important origin of acquired SNHL in childhood. Anti-inflammatory dexamethasone holds promises as potential adjuvant therapy to prevent SNHL associated with BM. However, in infant rats, pneumococcal meningitis (PM) increased auditory brainstem response (ABR) thresholds [mean difference = 54 decibels sound pressure level (dB SPL)], measured 3 wk after infection, irrespective to treatment with ceftriaxone plus dexamethasone or ceftriaxone plus saline (p < 0.005 compared with mock-infected controls). Moreover, dexamethasone did not attenuate short- and long-term histomorphologic correlates of SNHL. At 24 h after infection, blood-labyrinth barrier (BLB) permeability was significantly increased in infected animals of both treatment groups compared with controls. Three weeks after the infection, the averaged number of type I neurons per square millimeter of the Rosenthal's canal dropped from 0.3019 +/- 0.0252 in controls to 0.2227 +/- 0.0635 in infected animals receiving saline (p < 0.0005). Dexamethasone was not more effective than saline in preventing neuron loss (0.2462 +/- 0.0399; p > 0.05). These results suggest that more efficient adjuvant therapies are needed to prevent SNHL associated with pediatric PM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cochlear implants have been of great benefit in restoring auditory function to individuals with profound bilateral sensorineural deafness. The implants are used to directly stimulate auditory nerves and send a signal to the brain that is then interpreted as sound. This project focuses on the development of a surgical positioning tool to accurately and effectively place an array of stimulating electrodes deep within the cochlea. This will lead to improved efficiency and performance of the stimulating electrodes, reduced surgical trauma to the cochlea, and as a result, improved overall performance to the implant recipient. The positioning tool reported here consists of multiple fluidic chambers providing localized curvature control along the length of the attached silicon electrode array. The chambers consist of 200μm inner diameter PET (polyethylene therephthalate) tubes with 4μm wall thickness. The chambers are molded in a tapered helical configuration to correspond to the cochlear shape upon relaxation of the actuators. This ensures that the optimal electrode placement within the cochlea is retained after the positioning tool becomes dormant (for chronic implants). Actuation is achieved by injecting fluid into the PET chambers and regulating the fluidic pressure. The chambers are arranged in a stacked, overlapping design to provide fluid connectivity with the non-implantable pressure controller and allow for local curvature control of the device. The stacked tube configuration allows for localized curvature control of various areas along the length of the electrode and additional stiffening and actuating power towards the base. Curvature is affected along the entire length of a chamber and the result is cumulative in sections of multiple chambers. The actuating chambers are bonded to the back of a silicon electrode array.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mutations in the B1 subunit of the multisubunit vacuolar ATPase cause autosomal-recessive distal renal tubular acidosis and sensorineural deafness. Here, we report a novel frameshift mutation that truncates the C-terminus of the human B1 subunit. This mutant protein failed to assemble with other subunits in the cytosol to form the complex that can be targeted to vesicular structures in mammalian cells. Loss of proton pump activity was demonstrated in a functional complementation assay in B-subunit null yeast. The mutation caused loss of a discreet C-terminal region critical for subunit interaction not related to the C-terminal PDZ motif. Co-expression studies failed to demonstrate dominant negative effects of this truncated mutant over wild-type B1. Analysis of 12 reported B1 subunit missense mutations showed one polymorphic allele had intact pump function, two point mutants had intact assembly but defective proton pumping, and the remaining nine had disrupted assembly with no pump function. One presumed polymorphic allele was actually an inactivating mutation. Our study shows that multiple mechanisms of pump dysfunction result from B1 subunit mutations with a common outcome being defective assembly. Polymorphisms of the B1 subunit in the general population may affect renal acidification and urinary chemistry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cochlear implant (CI) is one of the most successful neural prostheses developed to date. It offers artificial hearing to individuals with profound sensorineural hearing loss and with insufficient benefit from conventional hearing aids. The first implants available some 30 years ago provided a limited sensation of sound. The benefit for users of these early systems was mostly a facilitation of lip-reading based communication rather than an understanding of speech. Considerable progress has been made since then. Modern, multichannel implant systems feature complex speech processing strategies, high stimulation rates and multiple sites of stimulation in the cochlea. Equipped with such a state-of-the-art system, the majority of recipients today can communicate orally without visual cues and can even use the telephone. The impact of CIs on deaf individuals and on the deaf community has thus been exceptional. To date, more than 300,000 patients worldwide have received CIs. In Switzerland, the first implantation was performed in 1977 and, as of 2012, over 2,000 systems have been implanted with a current rate of around 150 CIs per year. The primary purpose of this article is to provide a contemporary overview of cochlear implantation, emphasising the situation in Switzerland.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. DESIGN Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. RESULTS The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. CONCLUSIONS Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a novel homozygous missense mutation in the ubiquinol-cytochrome c reductase synthesis-like (BCS1L) gene in two consanguineous Turkish families associated with deafness, Fanconi syndrome (tubulopathy), microcephaly, mental and growth retardation. All three patients presented with transitory metabolic acidosis in the neonatal period and development of persistent renal de Toni-Debré-Fanconi-type tubulopathy, with subsequent rachitis, short stature, microcephaly, sensorineural hearing impairment, mild mental retardation and liver dysfunction. The novel missense mutation c.142A>G (p.M48V) in BCS1L is located at a highly conserved region associated with sorting to the mitochondria. Biochemical analysis revealed an isolated complex III deficiency in skeletal muscle not detected in fibroblasts. Native polyacrylamide gel electrophoresis (PAGE) revealed normal super complex formation, but a shift in mobility of complex III most likely caused by the absence of the BCS1L-mediated insertion of Rieske Fe/S protein into complex III. These findings expand the phenotypic spectrum of BCS1L mutations, highlight the importance of biochemical analysis of different primary affected tissue and underline that neonatal lactic acidosis with multi-organ involvement may resolve after the newborn period with a relatively spared neurological outcome and survival into adulthood. CONCLUSION Mutation screening for BCS1L should be considered in the differential diagnosis of severe (proximal) tubulopathy in the newborn period. What is Known: • Mutations in BCS1L cause mitochondrial complex III deficiencies. • Phenotypic presentations of defective BCS1L range from Bjornstad to neonatal GRACILE syndrome. What is New: • Description of a novel homozygous mutation in BCS1L with transient neonatal acidosis and persistent de Toni-Debré-Fanconi-type tubulopathy. • The long survival of patients with phenotypic presentation of severe complex III deficiency is uncommon.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gene encoding human myosin VIIA is responsible for Usher syndrome type III (USH1B), a disease which associates profound congenital sensorineural deafness, vestibular dysfunction, and retinitis pigmentosa. The reconstituted cDNA sequence presented here predicts a 2215 amino acid protein with a typical unconventional myosin structure. This protein is expected to dimerize into a two-headed molecule. The C terminus of its tail shares homology with the membrane-binding domain of the band 4.1 protein superfamily. The gene consists of 48 coding exons. It encodes several alternatively spliced forms. In situ hybridization analysis in human embryos demonstrates that the myosin VIIA gene is expressed in the pigment epithelium and the photoreceptor cells of the retina, thus indicating that both cell types may be involved in the USH1B retinal degenerative process. In addition, the gene is expressed in the human embryonic cochlear and vestibular neuroepithelia. We suggest that deafness and vestibular dysfunction in USH1B patients result from a defect in the morphogenesis of the inner ear sensory cell stereocilia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Muitos dos problemas auditivos não são notados por pais e professores. Este fato prejudica a aprendizagem da criança principalmente no ambiente escolar. Por isso, programas de triagem auditiva podem ser utilizados com o intuito de detectar e, posteriormente, diagnosticar escolares a fim de que se possa prevenir ou minimizar o impacto a que possíveis sequelas auditivas venham prejudicar o rendimento escolar da criança. Hoje em dia podemos contar com programas que permitem o melhor acompanhamento de populações que necessitam de cuidados preventivos e curativos, e a audição é um aspecto muito importante que pode ser avaliado quando estes programas são colocados em prática. O Programa Nacional de Reorientação da Formação Profissional em Saúde (Pró-Saúde), que visou reorientar a formação profissional, teve como objetivo integrar ensino-serviço e promover atenção básica por meio da abordagem integral do processo saúde-doença. Ambientes externos podem ser utilizados por alunos e professores universitários para que possam colocadas em prática ações que possibilitem a humanização das práticas de atenção a saúde e a integralidade das mesmas, por meio da articulação de ações e serviços de saúde, preventivos e curativos, individuais e coletivos. A escola é considerada um dos ambientes que este trabalho pode ser realizado. O Programa Saúde na Escola (PSE) abre o ambiente escolar com a finalidade de contribuir para a formação integral dos estudantes da rede pública de educação básica por meio de ações de prevenção, promoção e atenção à saúde. Sendo um estudo do tipo retrospectivo transversal, como objetivo principal caracterizar o perfil audiológico de escolares de escola pública do município de Bauru SP, contando com a integração de profissionais da área da saúde e educação no ambiente escolar, o que teve como base os programas citados acima. A triagem auditiva foi realizada com a aplicação dos seguintes procedimentos: imitanciometria, inspeção visual do meato acústico externo, emissões otoacústicas por produto de distorção e audiometria tonal liminar. Observou-se que do total de 652 estudantes, a grande maioria (97,1%) dos participantes com faixa etária entre 10 e 18 anos, apresentaram audição normal. Em 2,9% desta população foi encontrada alguma alteração auditiva temporária. Com a exceção de um único participante, portador de perda auditiva sensorioneural. Apesar de encontrarmos muitas crianças e adolescentes com audição normal, o que mais ressalta a importância deste trabalho é a necessidade da triagem auditiva em ambientes escolares e, essencialmente, o acompanhamento das mesmas nesta faixa etária, já que são escassos os estudos referentes a ela. Apesar das poucas alterações auditivas encontradas serem passageiras, são exatamente estas que interferem no bom rendimento escolar e outros fatores.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A perda auditiva unilateral (PAUn) é caracterizada pela diminuição da audição em apenas uma orelha. Indivíduos com este tipo de perda auditiva podem apresentar comprometimento nas habilidades auditivas de localização sonora, processamento temporal, ordenação e resolução temporal. O objetivo deste estudo foi verificar as habilidades auditivas de ordenação temporal, resolução temporal e localização sonora, antes e após a adaptação do aparelho de amplificação sonora individual (AASI). Foram avaliados 22 indivíduos, com idades entre 18 e 60 anos, com diagnóstico de PAUn sensorioneural ou mista, de graus leve a severo. O estudo foi dividido em duas etapas: a pré e a pós-adaptação de AASI. Em ambas as etapas, os indivíduos foram submetidos a uma anamnese, aplicação do Questionário de Habilidade Auditiva da Localização da fonte sonora, avaliação simplificada do processamento auditivo (ASPA) e Random Gap Detection Test (RGDT). O presente estudo encontrou diferença estatisticamente significante na avaliação da ASPA, exceto no teste de memória para sons não verbais em sequência (TMSnV), no RGDT e no Questionário de Habilidade Auditiva da Localização Sonora. A conclusão do estudo foi que com o uso efetivo do AASI, indivíduos com PAUn apresentaram melhora nas habilidades auditivas de localização sonora, ordenação e resolução temporal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A perda auditiva no idoso acarreta em dificuldade na percepção da fala. O teste comumente utilizado na logoaudiometria é a pesquisa do índice de reconhecimento de fala máximo (IR-Max) em uma única intensidade de apresentação da fala. Entretanto, o procedimento mais adequado seria a realização do teste em diversas intensidades, visto que o índice de acerto depende da intensidade da fala no momento do teste e está relacionado com o grau e configuração da perda auditiva. A imprecisão na obtenção do IR-Max poderá gerar uma hipótese diagnóstica errônea e o insucesso no processo de intervenção na perda auditiva. Objetivo: Verificar a interferência do nível de apresentação da fala, no teste de reconhecimento de fala, em idosos com perda auditiva sensorioneural com diferentes configurações audiométricas. Métodos: Participaram 64 idosos, 120 orelhas (61 do gênero feminino e 59 do gênero masculino), idade entre 60 e 88 anos, divididos em grupos: G1- composto por 23 orelhas com configuração horizontal, G2- 55 orelhas com configuração descendente, G3- 42 orelhas com configuração abrupta. Os critérios de inclusão foram: perda auditiva sensorioneural de grau leve a severo, não usuário de aparelho de amplificação sonora individual (AASI), ou com tempo de uso inferior a dois meses, e ausência de alterações cognitivas. Foram realizados os seguintes procedimentos: pesquisas do limiar de reconhecimento de fala (LRF), do índice de reconhecimento de fala (IRF) em diversas intensidades e do nível de máximo conforto (MCL) e desconforto (UCL) para a fala. Para tal, foram utilizadas listas com 11 monossílabos, para diminuir a duração do teste. A análise estatística foi composta pelo teste Análise de Variância (ANOVA) e teste de Tukey. Resultados: A configuração descendente foi a de maior ocorrência. Indivíduos com configuração horizontal apresentaram índice médio de acerto mais elevado de reconhecimento de fala. Ao considerar o total avaliado, 27,27% dos indivíduos com configuração horizontal revelaram o IR-Max no MCL, assim como 38,18% com configuração descendente e 26,19% com configuração abrupta. O IR-Max foi encontrado no UCL, em 40,90% dos indivíduos com configuração horizontal, 45,45% com configuração descendente e 28,20% com configuração abrupta. Respectivamente, o maior e o menor índice médio de acerto foram encontrados em: G1- 30 e 40 dBNS; G2- 50 e 10 dBNS; G3- 45 e 10 dBNS. Não há uma única intensidade de fala a ser utilizada em todos os tipos de configurações audiométricas, entretanto, os níveis de sensação que identificaram os maiores índices médios de acerto foram: G1- 20 a 30 dBNS, G2- 20 a 50 dBNS; G3- 45 dBNS. O MCL e o UCL-5 dB para a fala não foram eficazes para determinar o IR-Max. Conclusões: O nível de apresentação teve influência no desempenho no reconhecimento de fala para monossílabos em idosos com perda auditiva sensorioneural em todas as configurações audiométricas. A perda auditiva de grau moderado e a configuração audiométrica descendente foram mais frequentes nessa população, seguida da abrupta e horizontal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014