Comprehensive measures of sound exposures in cinemas using smart phones


Autoria(s): Huth, Markus; Popelka, Gerald R; Blevins, Nikolas H
Data(s)

2014

Resumo

OBJECTIVES Sensorineural hearing loss from sound overexposure has a considerable prevalence. Identification of sound hazards is crucial, as prevention, due to a lack of definitive therapies, is the sole alternative to hearing aids. One subjectively loud, yet little studied, potential sound hazard is movie theaters. This study uses smart phones to evaluate their applicability as a widely available, validated sound pressure level (SPL) meter. Therefore, this study measures sound levels in movie theaters to determine whether sound levels exceed safe occupational noise exposure limits and whether sound levels in movie theaters differ as a function of movie, movie theater, presentation time, and seat location within the theater. DESIGN Six smart phones with an SPL meter software application were calibrated with a precision SPL meter and validated as an SPL meter. Additionally, three different smart phone generations were measured in comparison to an integrating SPL meter. Two different movies, an action movie and a children's movie, were measured six times each in 10 different venues (n = 117). To maximize representativeness, movies were selected focusing on large release productions with probable high attendance. Movie theaters were selected in the San Francisco, CA, area based on whether they screened both chosen movies and to represent the largest variety of theater proprietors. Measurements were analyzed in regard to differences between theaters, location within the theater, movie, as well as presentation time and day as indirect indicator of film attendance. RESULTS The smart phone measurements demonstrated high accuracy and reliability. Overall, sound levels in movie theaters do not exceed safe exposure limits by occupational standards. Sound levels vary significantly across theaters and demonstrated statistically significant higher sound levels and exposures in the action movie compared to the children's movie. Sound levels decrease with distance from the screen. However, no influence on time of day or day of the week as indirect indicator of film attendance could be found. CONCLUSIONS Calibrated smart phones with an appropriate software application as used in this study can be utilized as a validated SPL meter. Because of the wide availability, smart phones in combination with the software application can provide high quantity recreational sound exposure measurements, which can facilitate the identification of potential noise hazards. Sound levels in movie theaters decrease with distance to the screen, but do not exceed safe occupational noise exposure limits. Additionally, there are significant differences in sound levels across movie theaters and movies, but not in presentation time.

Formato

application/pdf

Identificador

http://boris.unibe.ch/65615/1/00003446-201411000-00010.pdf

Huth, Markus; Popelka, Gerald R; Blevins, Nikolas H (2014). Comprehensive measures of sound exposures in cinemas using smart phones. Ear and hearing, 35(6), pp. 680-686. Lippincott Williams & Wilkins 10.1097/AUD.0000000000000076 <http://dx.doi.org/10.1097/AUD.0000000000000076>

doi:10.7892/boris.65615

info:doi:10.1097/AUD.0000000000000076

info:pmid:25075764

urn:issn:0196-0202

Idioma(s)

eng

Publicador

Lippincott Williams & Wilkins

Relação

http://boris.unibe.ch/65615/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Huth, Markus; Popelka, Gerald R; Blevins, Nikolas H (2014). Comprehensive measures of sound exposures in cinemas using smart phones. Ear and hearing, 35(6), pp. 680-686. Lippincott Williams & Wilkins 10.1097/AUD.0000000000000076 <http://dx.doi.org/10.1097/AUD.0000000000000076>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed