840 resultados para operational reliability


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Direct Assessment of Functional Status-Revised (DAFS-R) is an instrument developed to objectively measure functional capacities required for independent living. The objective of this study was to translate and culturally adapt the DAFS-R for Brazilian Portuguese (DAFS-BR) and to evaluate its reliability and validity. The DAFS-BR was administered to 89 older patients classified previously as normal controls, mild cognitive impairment (MCI) and Alzheimer`s disease (AD). The results indicated good internal consistency (Cronbach`s alpha = 0.78) in the total sample. The DAFS-BR showed high interobserver reliability (0.996; p < .001) as well as test-retest stability over 1-week interval (0.995; p < .001). Correlation between the DAFS-BR total score and the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE) was moderate and significant (r = -.65, p < .001) in the total sample, whereas it did not reach statistical significance within each diagnostic group. Receiver operating characteristic curve analyses suggested that DAFS-BR has good sensitivity and specificity to identify MCI and AD. Results suggest that DAFS-BR can document degrees of severity of functional impairment among Brazilian older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose of review This review discusses ovarian reserve tests for ovulation induction and their application in determining fertility capacity, and their current applications to assess risk of natural ovarian failure and to estimate ovarian function after cancer treatment. Recent findings The current arsenal of ovarian reserve tests comprises hormonal markers [basal follicle stimulating hormone, estradiol, inhibin-B, antimullerian hormone (AMH)] and ultrasonographic markers [ovarian volume, antral follicle counts (AFCs)]. These markers have limitations in terms of which test(s) should be used to reliably predict ovarian reserve with regard to accuracy, invasiveness, cost, convenience, and utility. Several studies have correlated sonographic AFCs with serum AMH levels for predicting the ovarian response to ovulation induction protocols during assisted reproduction treatments. Summary Serum AMH levels and AFC are reliable tests for predicting the ovarian response to ovulation induction. However, none of the currently employed tests of ovarian reserve can reliably predict pregnancy after assisted conception. Further, ovarian reserve tests cannot predict the onset of reproductive and hormonal menopause; thus, they should be used with caution for reproductive life-programming counseling. Moreover, there is no evidence to support the use of ovarian reserve tests to estimate the risk of ovarian sufficiency after cancer treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In organ transplantation, the immunosuppression withdrawal leads, in most cases, to rejection. Nonetheless, a special group of patients maintain stable graft function after complete withdrawal of immunosuppression, achieving a state called ""operational tolerance."" The study of such patients may be important to understand the mechanisms involved in human transplantation tolerance. We compared the profile of CD4(+)CD25(+)Foxp3(+) T cells and the signaling pathways IL-6/STAT3 (signal transducers and activators of transcription) and IL-4/STAT6 in peripheral blood mononuclear cells of four kidney transplant groups: (i) operational tolerance (OT), (ii) chronic allograft nephropathy (CR), (iii) stable graft function under standard immunosuppression (Sta), (iv) stable graft function under low immunosuppression, and (v) healthy individuals. Both CR and Sta displayed lower numbers and percentages of CD4(+)CD25(+)Foxp3(+) T cells compared with all other groups (p < 0.05). The OT patients displayed a reduced activation of the IL-4/STAT6 pathway in monocytes, compared with all other groups (p < 0.05). The lower numbers of CD4(+)CD25(+)Foxp3(+) T cells observed in CR individuals may be a feature of chronic allograft nephropathy. The differential OT signaling profile, with reduced phosphorylation of STAT6, in monocytes` region, suggests that some altered function of STAT6 signaling may be important for the operational tolerance state. Crown copyright (C) 2010 Published by Elsevier Inc. on behalf of American Society for Histocompatibility and Immunogenetics. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Axial vertebral rotation, an important parameter in the assessment of scoliosis may be identified on X-ray images. In line with the advances in the field of digital radiography, hospitals have been increasingly using this technique. The objective of the present study was to evaluate the reliability of computer-processed rotation measurements obtained from digital radiographs. A software program was therefore developed, which is able to digitally reproduce the methods of Perdriolle and Raimondi and to calculate semi-automatically the rotation degree of vertebra on digital radiographs. Three independent observers estimated vertebral rotation employing both the digital and the traditional manual methods. Compared to the traditional method, the digital assessment showed a 43% smaller error and a stronger correlation. In conclusion, the digital method seems to be reliable and enhance the accuracy and precision of vertebral rotation measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aimed to assess the reliability of intra and inter-examiner subacromial impingement index (SII) measures obtained from radiographs. Thirty-six individuals were enrolled and divided into two groups: control group, composed of 18 volunteers in good general health without shoulder problems, and a group of 18 patients with subacromial impingement syndrome (SIS). Radiographic images were taken with the dominant upper limb in neutral rotation, while the volunteers held their arm at 90A degrees of abduction in the frontal plane. The beam of radiation at 30A degrees craniocaudal inclination was used to provide an antero-posterior image view. Three blinded examiners each performed three measurements from the subacromial space (SS) and the anatomical neck of the humerus (NH). The SII was calculated as the ratio of the SS and the NH measures. The mean values of SII were compared using t-tests. The intra-class correlation coefficient (ICC) was used to assess intra- and inter-examiner reliability of the measures. The mean values of SII were greater for the control group (0.12) than for the SIS group (0.08; p = 0.0071). SII measurements showed excellent intra (0.96-0.99) and inter-examiner reliability (0.94) for both the control and SIS group. The results of this study show the potential use of the SII; a greater mean value for the control group compared to the SIS group and excellent reliability for intra- and inter-examiner measurement. Validation studies of the index should be conducted to correlate the index with clinical findings from subacromial impingement syndrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the intra and interday reliability of surface electromyographic amplitude values of the scapular girdle muscles and upper limbs during 3 isometric closed kinetic chain exercises, involving upper limbs with the fixed distal segment extremity on stable base of support and on a Swiss ball (relatively unstable). Twenty healthy adults performed the exercises push-up, bench-press and wall-press with different effort levels (80% and 100% maximal load). Subjects performed three maximal voluntary contractions (MVC) in muscular testing position of each muscle to obtain a reference value for root mean square (RMS) normalization. Individuals were instructed to randomly perform three isometric contraction series, in which each exercise lasted 6 s with a 2-min resting-period between series and exercises. Intra and interday reliabilities were calculated through the intraclass correlation coefficient (ICC 2.1), standard error of the measurement (SEM). Results indicated an excellent intraday reliability of electromyographic amplitude values (ICC >= 0.75). The interday reliability of normalized RMS values ranged between good and excellent (ICC 0.52-0.98). Finally, it is suggested that the reliability of normalized electromyographic amplitude values of the analyzed muscles present better values during exercises on a stable surface. However, load levels used during the exercises do not seem to have any influence on variability levels, possibly because the loads were quite similar. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Pain and anxiety are a common problem in all recovery phases after a burn. The Burns Specific Pain Anxiety Scale (BSPAS) was proposed to assess anxiety in burn patients related to painful procedures. Objectives: To assess internal consistency, discriminative construct validity, dimensionality and convergent construct validity of the Brazilian-Portuguese version of the Burns Specific Pain Anxiety Scale. Design: In this cross-sectional study, the original version of the BSPAS, adapted into Brazilian Portuguese, was tested for internal consistency (Cronbach`s Alpha), discriminative validity (related to total body surface area burned and sex), dimensionality (through factor analysis), and convergent construct validity (applying the Visual Analogue Scale for pain and State-Anxiety-STAI) in a group of 91 adult burn patients. Results: The adapted version of the BSPAS displayed a moderate and positive correlation with pain assessments: immediately before baths and dressings (r = 0.32; p < 0.001), immediately after baths and dressings (r = 0.31; p < 0.001) and during the relaxation period (r= 0.31; p < 0.001) and with anxiety assessments (r = 0.34; p < 0.001). No statistically significant differences were observed when comparing the mean of the adapted version of the BSPAS scores with sex (p = 0.194) and total body surface area burned (p = 0.162) (discriminative validity). The principal components analysis applied to our sample seems to confirm anxiety as one single domain of the Brazilian-Portuguese version of the BSPAS. Cronbach`s Alpha showed high internal consistency of the adapted version of the scale (0.90). Conclusion: The Brazilian-Portuguese version of the BSPAS 9-items has shown statically acceptable levels of reliability and validity for pain-related anxiety evaluation in burn patients. This scale can be used to assess nursing interventions aimed at decreasing pain and anxiety related to the performance of painful procedures. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate whether standardization of the multiplanar view (SMV) when evaluating the uterus using three-dimensional ultrasonography (3D-US) improves intra-and interobserver reliability and agreement with regard to endometrial measurement. Methods Two-dimensional (2D) and 3D-US was used to measure endometrial thickness by two observers in 30 women undergoing assisted reproduction treatment. Endometrial volume was measured with Virtual Organ Computer-aided AnaLysis (VOCAL (TM)) in the longitudinal (A) and coronal (C) planes using an unmodified multiplanar view (UMV) and a standardized multiplanar view (SMV). Measurement reliability was evaluated by intraclass correlation coefficient (ICC) and agreement was examined using Bland-Altman plots with limits of agreement (LoA). The ease of outlining the endometrial-myometrial interface was compared between the A-and C-planes using subjective assessment. Results Endometrial volume measurements using the SMV and A-plane were more reliable (intra-and interobserver ICCs, 0.979 and 0.975, respectively) than were measurements of endometrial thickness using 2D-US (intra-and interobserver ICCs, 0.742 and 0.702, respectively) or 3D-US (intra-and interobserver ICCs, 0.890 and 0.784, respectively). The LoAs were narrower for SMV than for UMV. Reliability and agreement were not much different between the A- and C-planes. However the observers agreed that delineating the endometrial-myometrial interface using the A-plane was easier (first and second observer, 50.0 and 46.7%, respectively) or `comparable` (50 and 53.3%, respectively), but never more difficult than using the C-plane. Conclusions Endometrial volume measurements are more reliable than endometrial thickness measurements and are best performed using SMV and the A-plane. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare the intra-and inter-rater reliability of pressure pain threshold (PPT) and manual palpation (MP) of orofacial structures in symptomatic and symptom-free children for temporomandibular disorders (TMD). Fourteen children reporting pain in masticatory muscles or the temporomandibular joint and 16 symptom-free children were randomly assessed on three different occasions: by rater-1 in the first and third session and by rater-2 in the second session. The trained raters applied algometry and MP as recommended by the Research Diagnostic Criteria for TMD. Intraclass correlation coefficients and the Kappa statistic were used to assess the levels of reliability of PPT and MP, respectively. Excellent intra-and inter-rater reliability levels were observed for PPT values at most of the examined sites for symptom-free children and excellent and moderate reliability levels for children reporting pain. For MP, moderate and poor intra-rater and inter-rater reliability levels were observed for most sites in both groups. Algometry showed higher reliability levels for both groups of children and is recommended for pain assessment in children in association with MP. (C) 2010 Elsevier Ltd. All rights reserved.