956 resultados para column flotation
Resumo:
An efficient flotation method based on the combination of flame atomic absorption spectrometry (FAAS) and separation and preconcentration step for determination of Cr3+, Cu 2+, Co2+, Ni2+, Zn2+, Cd 2+, Fe3+ and Pb2+ ions in various real samples by the possibility of applying bis(2-hydroxyacetophenone)-1,4-butanediimine (BHABDI) as a new collector was studied. The influence of pH, amount of BHABDI as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates i.e. variables affecting the efficiency of the extraction system was evaluated. It is ascertained that metal ions such as iron can be separated simultaneously from matrix in the presence of 0.012 mM ligand, 0.025% (w/v) of CTAB to a test sample of 750 mL at pH 6.5. These ions can be eluted quantitatively with 6 mL of 1.0 mol L-1 HNO3 in methanol which lead to the enrichment factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL-1. The method has been successfully applied for determination of trace amounts of ions in various real samples.
Resumo:
A new simple and sensitive flotation-spectrophotometric method for the determination of cetylpyridinium chloride (CPC) is reported. The method is based on the formation of an ion- associate between CPC and Orange II (OR) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. The aqueous solution was discarded and the adsorbed ion associate on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 480 nm. The apparent molar absorptivity (Ε) of the ion associate was determined to be 4.12 x 10(5) L mol-1 cm-1. The calibration graph was linear in the concentration range of 15-800 ng mL-1 of CPC with a correlation coefficient of 0.9988. The limit of detection (LOD) was 10.8 ng mL-1. The relative standard deviation (RSD) for determination of 100 and 800 ng mL-1 of CPC was 3.47 and 2.04% (n=7), respectively. The method was successfully applied to the determination of CPC in a commercial mouth washer product.
Resumo:
An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using liquid-liquid extraction. The total run time was 2.0 min. The separation was achieved with HPLC-RP using a monolithic column. The assay was linear in the concentration range of 100 - 5000 ng mL-1. The mean recovery was 83%. Intra- and inter-day precision were < 9.5% and < 8.9%, respectively and accuracy was in the range ± 8.33%. The method was successfully applied to a bioequivalence study.
Resumo:
Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC) the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.
Resumo:
The purpose of this study was to develop a rapid, simple and sensitive quantitation method for pseudoephedrine (PSE), paracetamol (PAR) and loratadine (LOR) in plasma and pharmaceuticals using liquid chromatography-tandem mass spectrometry with a monolithic column. Separation was achieved using a gradient composition of methanol-0.1% formic acid at a flow rate of 1.0 mL min-1. Mass spectral transitions were recorded in SRM mode. System validation was evaluated for precision, specificity and linearity. Limit of detection for pseudoephedrine, paracetamol, and loratadine were determined to be 3.14, 1.86 and 1.44 ng mL-1, respectively, allowing easy determination in plasma with % recovery of 93.12 to 101.56%.
Resumo:
An efficient method for the rapid separation and purification of polyphenols from artichoke by polyamide column chromatography in combination with high-speed counter-current chromatography (HSCCC) was successfully built. The crude ethanol extracts from dry artichoke were first pre-separated by polyamide column chromatography and divided in two parts as sample 1 and sample 2. Then, the samples were further separated by HSCCC and yielded 7.8 mg of chlorogenic acid (compound I), 24.5 mg of luteolin-7-O-β-D-rutinoside (compound II), 18.4 mg of luteolin-7-O-β-D-glucoside (compound III), and 33.4 mg of cynarin (compound IV) with purity levels of 92.0%, 98.2%, 98.5%, and 98.0%, respectively, as determined by high-performance liquid chromatography (HPLC) method. The chemical structures of these compounds were identified by electrospray ionization-mass spectrometry (ESI-MS) and nuclear magnetic resonance (NMR).
Resumo:
An effective method for the rapid separation and purification of three stilbenes from the radix of Polygonum cillinerve (Nakai) Ohwl by macroporous resin column chromatography combined with high-speed counter-current chromatography (HSCCC) was successfully established. In the present study, a two-phase solvent system composed of chloroform-n-butanol-methanol-water (4:1:4:2, v/v/v/v) was used for HSCCC separation. A one-step separation in 4 h from 150 mg of crude extract produced 26.3 mg of trans-resveratrol-3-O-glucoside, 42.0 mg of pieceid-2"-O-gallate, and 17.9 mg of trans-resveratrol with purities of 99.1%, 97.8%, and 99.4%, respectively, as determined by high-performance liquid chromatography (HPLC). The chemical structures of these compounds were identified by nuclear magnetic resonance (NMR) spectroscopy.
Resumo:
A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) followed by graphite furnace atomic absorption spectrometry (GFAAS). Ammonium pyrrolidine dithiocarbamate (APDC) was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.
Resumo:
Vaahdotusta käytetään yleisesti erottamaan eri mineraaleja malmista. Tässä menetelmässä käytetään erityisiä pinta-aktiivisia aineita, joita kutsutaan kokoojakemikaaleiksi, muuntamaan halutut mineraalit hydrofobisiksi ja erottamaan ne hydrofiilisistä partikkeleista ilmakuplien avulla. Eräs tärkeimmistä kokoojakemikaalien ryhmistä on ksantaatit. Ksantaateilla on havaittu taipumusta hajota useiksi erilaisiksi hajoamistuotteiksi vaahdotusprosessin aikana. Näillä hajoamistuotteilla voi olla monia haitallisia vaikutuksia vaahdotuksen tuloksiin. Näiden tuotteiden tunnistaminen ja määrittäminen on tärkeää vaahdotusprosessin paremman ymmärtämisen kannalta. Työn kirjallisuusosassa vaahdotusprosessi, ksantaatit ja niiden yleisimmät hajoamistuotteet on esitelty, kuten myös käytetty analyysimenetelmä, kapillaarielektroforeesi. Työn kokeellisessa osassa etsittiin sopivaa erotusmenetelmää etyyliksantaatin, etyylitiokarbonaatin, etyyliperksantaatin ja etyyliksantyylitiosulfaatin erottamiseksi kapillaarilelektroforeesilla. Pääasiassa keskityttiin kahteen eri erotusmenetelmään. Ensimmäinen menetelmä kykeni erottamaan kaikki tutkitut tuotteet puhdasvesinäytteissä, ja toinen menetelmä oli sopiva näiden tuotteiden erottamiseen prosessivesinäytteissä. Jälkimmäistä menetelmää kokeiltiin käytännössä rikastamolla, jossa sillä kyettiin erottamaan isobutyyliksantaatti, isobutyylitiokarbonaatti, ja suurella todennäköisyydellä myös isobutyyliperksantaatti.
Resumo:
Vaahdotusprosessia käytetään yleisesti erottamaan arvokkaita mineraaleja malmeista. Toimiakseen tehokkaasti prosessi tarvitsee kokoojakemikaaleja, joiden tehtävänä on sitoa halutut mineraalit ilmakupliin. Jotta näiden kemikaalien käyttäytymistä prosessissa voitaisiin ymmärtää paremmin ja prosessin ohjausta tehostaa, pitää kokoojia pystyä analysoimaan prosessivesistä. Työn kirjallisuusosassa on koottu ja vertailtu erilaisia kirjallisuudesta löytyneitä analyysimenetelmiä kokoojakemikaaleille. Kokeellisessaosassa on kehitetty kaksi kapillaarielektroforeesimenetelmää näiden kemikaalien tutkimiseen. Menetelmien toteamisrajat tutkituille kemikaaleille olivat seuraavanlaiset: natrium diiosobutylditiofosfaattille (DTP) 2,7 mg/L puhtaassa vedessä ja 6,7 mg/L prosessivedessä; natrium diisobutyldithiofosfinaatille (DTPI) vastaavasti 4,5 mg/L ja 6,7 mg/L; etyyli ksantaatille 0,025 mg/L ja 0,16 mg/L; ja isobutyyli ksantaatille 0,41 mg/L ja 0,62 mg/L. Näitä menetelmiä voidaan tulevaisuudessa kehittää kokoojien hajoamistuotteiden analysointia varten sekä prosessien on-line mittauksiin.
Resumo:
Valuable minerals can be recovered by using froth flotation. This is a widely used separation technique in mineral processing. In a flotation cell hydrophobic particles attach on air bubbles dispersed in the slurry and rise on the top of the cell. Valuable particles are made hydrophobic by adding collector chemicals in the slurry. With the help of a frother reagent a stable froth forms on the top of the cell and the froth with valuable minerals, i.e. the concentrate, can be removed for further processing. Normally the collector is dosed on the basis of the feed rate of the flotation circuit and the head grade of the valuable metal. However, also the mineral composition of the ore affects the consumption of the collector, i.e. how much is adsorbed on the mineral surfaces. Therefore it is worth monitoring the residual collector concentration in the flotation tailings. Excess usage of collector causes unnecessary costs and may even disturb the process. In the literature part of the Master’s thesis the basics of flotation process and collector chemicals are introduced. Capillary electrophoresis (CE), an analytical technique suitable for detecting collector chemicals, is also reviewed. In the experimental part of the thesis the development of an on-line CE method for monitoring the concentration of collector chemicals in a flotation process and the results of a measurement campaign are presented. It was possible to determine the quality and quantity of collector chemicals in nickel flotation tailings at a concentrator plant with the developed on-line CE method. Sodium ethyl xanthate and sodium isopropyl xanthate residuals were found in the tailings and slight correlation between the measured concentrations and the dosage amounts could be seen.
Resumo:
The acid mining drainage is considered the most significant environmental pollution problem around the world for the extensive formation acidic leachates containing heavy metals. Adsorption is widely used methods in water treatment due to it easy operation and the availability of a wide variety of commercial adsorbent (low cost). The primary goal of this thesis was to investigate the efficiency of neutralizing agents, CaCO3 and CaSiO3, and metal adsorption materials with unmodified limestone from Company Nordkalk Oy. In addition to this, the side materials of limestone mining were tested for iron adsorption from acidic model solution. This study was executed at Lappeenranta University of Technology, Finland. The work utilised fixed-bed adsorption column as the main equipment and large fluidized column. Atomic absorption spectroscopy (AAS) and x-ray diffraction (XRD) was used to determine ferric removal and the composition of material respectively. The results suggest a high potential for the studied materials to be used a low cost adsorbents in acid mine drainage treatment. From the two studied adsorbents, the FS material was more suitable than the Gotland material. Based on the findings, it is recommended that further studies might include detailed analysis of Gotland materials.
Resumo:
Analyses of ochratoxin A (OTA) in domestic and imported beers were perfomed by immunoaffinity column and high - perfomance liquid chromatography (HPLC) using a fluorescence detector. Recoveries of OTA from beer samples spiked at levels from 8.0 to 800pg/mL ranged from 81.2% to 95.0%, with coefficient of variation between 0% e 11.0%. Detection limit and quantification limit were 2.0pg/mL and 8.0pg/mL, respectively. Of the total of 26 samples produced in Brazil only 6 (23%), contained trace amounts of OTA. Of the 4 imported beers, in 2, Ireland and Germany, were detected OTA at levels of 25pg/mL and 82pg/mL, respectively.