A sensitive and robust lc-ms/ms method with monolithic column and electrospray ionization for the quantitation of efavirenz in human plasma: application to a bioequivalence study


Autoria(s): Bedor,Danilo Cesar Galindo; Souza Filho,Jose Homero de; Ramos,Virna Ligiane Souza; Gonçalves,Talita Mota; Sousa,Carlos Eduardo Miranda de; Santana,Davi Pereira de
Data(s)

01/01/2011

Resumo

An LC-MS/MS method has been developed for the determination of efavirenz (EFZ) in human plasma using hydrochlorothiazide as internal standard (I.S.). An ESI negative mode with multiple reaction-monitoring was used monitoring the transitions m/z 313.88→69.24 (EFZ) and 296.02→204.76 (I.S.). Samples were extracted using liquid-liquid extraction. The total run time was 2.0 min. The separation was achieved with HPLC-RP using a monolithic column. The assay was linear in the concentration range of 100 - 5000 ng mL-1. The mean recovery was 83%. Intra- and inter-day precision were < 9.5% and < 8.9%, respectively and accuracy was in the range ± 8.33%. The method was successfully applied to a bioequivalence study.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422011000600007

Idioma(s)

en

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.34 n.6 2011

Palavras-Chave #efavirenz #bioequivalence #LC-MS/MS
Tipo

journal article