999 resultados para Xe lamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work the photoluminescence (PL) character of sapphire implanted with 180 keV Xe and irradiated with 308 MeV Xe ions was studied. The virgin, implanted and irradiated samples were investigated by PL and Fourier transform infrared (FTIR) spectra measurements. The obtained PL spectra showed the maximum emission bands at 2.75, 3.0 and 3.26 eV for the implanted fluence of 1.0 x 10(15) ions/cm(2) and at 2.4 and 3.47 eV for the irradiated fluence of 1.0 x 10(13) ions/cm(2). The FTIR spectra showed a broaden absorption band between 460 and 630 cm(-1), indicating that strong damaged region formed in Al2O3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ZnO films were deposited on (100) Si substrate by radio frequency magnetron sputtering. These films were irradiated at room temperature with 308 MeV Xe-ions to a fluence of 1.0 x 10(12), 1.0 x 10(13) or 1.0 x 10(14) Xe/cm(2). Then the samples were investigated using RBS, XRD, FESEM and PL analyses. The obtained experimental results showed that the deposited ZnO films were highly c-axis orientated and of high purity, 308 MeV Xe-ion irradiations could not change the c-axis oriented. The topography and PL properties of the ZnO films varied with increasing the Xe-ion irradiation fluence. For 1.0 x 10(13) or 1.0 x 10(14) Xe/cm(2) irradiated samples, surface cracks were observed. Furthermore, it was found that the 1.0 x 10(14) Xe/cm(2) irradiated sample exhibiting the strongest PL ability. The modification of structure and PL properties induced by 308 MeV Xe-ion irradiations were briefly discussed. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the slow highly charged ions Xe-129(q+) (q = 25, 26, 27; initial kinetic T-0 <= 4.65 keV/a.u.) to impact Au surface, the Au atomic M alpha characteristic X-ray spectrum is induced. The result shows that as long as the charge state of projectile is high enough, the heavy atomic characteristic X-ray can be effectively excited even though the incident beam is very weak (nA magnitude), and the X-ray yield per ion is in the order of 10(-8) and increases with the kinetic energy and potential energy of projectile. By measuring the Au M alpha-X-ray spectra, Au atomic N-level lifetime is estimated at about 1.33x10(-18) s based on Heisenberg uncertainty relation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work specimens of mono-crystalline silicon carbide (4H polytype) were irradiated to three successively increasing ion fluences ranging from 7.2 x 10(14) to 6.0 x 10(16) ions/cm(2) (corresponding to the peak displacement damage of 1, 4 and 13 dpa) with Ne and Xe ions respectively with the energy of 2.3 MeV/amu. The irradiated specimens were subsequently annealed at temperatures of 1173 and 1273 K. Defect structure was investigated with transmission electron microscopy (TEM) using a cross-sectional specimen preparation technique. The typical microstructures of the annealed specimens irradiated with Ne or Xe ions to high fluences are characterized by small gas bubbles in high concentration in the peak damage region and black dots and dislocation loops (located in the basal plane) in a shallower and broader depth region. Larger dislocation loops were observed in the Xe-ion irradiated specimen than in the Ne-ion irradiated specimen at the same peak damage level. The enhanced formation of dislocation loops in the case of Xe-ion irradiation is understandable by assuming stronger inclination of heavier inert-gas atoms to occupy substitute site in the peak damage region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silica glass samples were implanted with 1.157 GeV Fe-56 and 1.755 GeV Xe-136 ions to fluences range from 1 x 10(11) to 3.8 x 10(12) ions/cm(2). Virgin and irradiated samples were investigated by ultraviolet (UV) absorption from 3 to 6.4 eV and photoluminescence (PL) spectroscopy. The UV absorption investigation reveals the presence of various color centers (E' center, non-bridging oxygen hole center (NBOHC) and ODC(II)) appearing in the irradiated samples. It is found that the concentration of all color centers increase with the increase of fluence and tend to saturation at high fluence. Furthermore the concentration of E' center and that of NBOHC is approximately equal and both scale better with the energy deposition through processes of electronic stopping, indicating that E' center and NBOHC are mainly produced simultaneously from the scission of strained Si-O-Si bond by electronic excitation effects in heavy ion irradiated silica glass. The PL measurement shows three emissions peaked at about 4.28 eV (alpha band), 3.2 eV (beta band) and 2.67 eV (gamma band) when excited at 5 eV. The intensities of alpha and gamma bands increase with the increase of fluence and tend to saturation at high fluence. The intensity of beta band is at its maximum in virgin silica glass and it is reduced on increasing the ions fluence. It is further confirmed that nuclear energy loss processes determine the production of alpha and gamma bands and electronic energy loss processes determine the bleaching of beta band in heavy ion irradiated silica glass. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

室温下,用94MeV的Xe离子辐照纳米晶和非晶硅薄膜以及单晶硅样品,辐照量分别为1.0×1011,1.0×1012和1.0×1013ions/cm2。所有样品均在室温下用UV/VIS/NIR光谱仪进行检测分析。通过对比研究了纳米晶、非晶、单晶硅样品的光学带隙随Xe离子辐照量的变化。结果表明,不同结构的硅材料中Xe离子辐照引起的光学带隙变化规律差异显著:随着Xe离子辐照量的增加,单晶硅的光学带隙基本不变,非晶硅薄膜的光学带隙由初始的约1.78eV逐渐减小到约1.54eV,而纳米晶硅薄膜的光学带隙则由初始的约1.50eV快速增大至约1.81eV,然后再减小至约1.67eV。对硅材料结构影响辐照效应的机理进行了初步探讨。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the characteristic X-ray spectra produced by the interaction of highly charged ions of X-129(q+) (q =25, 26, 27) with surface of metallic Mo. The experimental result shows that highly charged ions can excite the characteristic X-ray spectra of L-shell of Mo when the beam' s intensity is not more than 120 nA. The X-ray yield of single ion reaches a quantitative level of 10(-8) and increases with the increment of the ion' s kinetic energy and ionic charge (potential energy). By measuring the X-ray spectra of Mo-L alpha(1) the M-level lifetime of Mo atom is estimated by using Heisenberg uncertainty relation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

研究了高电荷态离子129Xeq+(q=25,26,27)入射金属Mo表面产生的特征X射线谱.实验结果表明,在束流强度小于120nA条件下,高电荷态离子129Xeq+可以激发Mo的L壳层特征X射线谱.单离子X射线相对产额可达10-8量级,特征X射线的相对产额随入射离子的动能和电荷态(势能)的增加而增加.通过Mo原子的Lα1特征X射线谱,利用Heisenberg不确定关系对Mo原子的第M能级寿命进行了估算.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

研究了交联XE-60和PEG-20M极性固定相非晶硅膜改性弹性玻璃毛细管柱,在适当的温度下,用过氧化二异丙苯(DCUP)游离基引发交联,成功地制备了XE-60和PEG-20M极性柱,它们均具有柱效高、惰性好、化学稳定性好和耐溶剂、抗腐蚀、耐高温等性能,是一种新型的极性交联柱。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

硅膜改性弹性玻璃毛细管柱做为一种新柱型,它具有类似弹性石英柱的柔性和惰性,也具有玻璃柱制作容易、材质易得的优点。硅膜做为固定相载体的色谱特性研究目前报道还很少,非极性硅酮相在其上的交联我们曾做过报

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange. METHODS AND PRINCIPAL FINDINGS: Here we exploit the solubility, high magnetic resonance (MR) signal intensity, and large chemical shift of hyperpolarized (HP) (129)Xe to probe the regional uptake of alveolar gases by directly imaging HP (129)Xe dissolved in the gas exchange tissues and pulmonary capillary blood of human subjects. The resulting single breath-hold, three-dimensional MR images are optimized using millisecond repetition times and high flip angle radio-frequency pulses, because the dissolved HP (129)Xe magnetization is rapidly replenished by diffusive exchange with alveolar (129)Xe. The dissolved HP (129)Xe MR images display significant, directional heterogeneity, with increased signal intensity observed from the gravity-dependent portions of the lungs. CONCLUSIONS: The features observed in dissolved-phase (129)Xe MR images are consistent with gravity-dependent lung deformation, which produces increased ventilation, reduced alveolar size (i.e., higher surface-to-volume ratios), higher tissue densities, and increased perfusion in the dependent portions of the lungs. Thus, these results suggest that dissolved HP (129)Xe imaging reports on pulmonary function at a fundamental level.