945 resultados para Time of Arrival Method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for measuring the volume of air in the lungs at the time of underwater weighing is described. A low concentration of hydrogen is used as a tracer gas in a closed-circuit rebreathing system. At the end of a normal exhalation the subject is connected to a respiratory bladder containing 2 L of air with a small admixture of hydrogen. After an equilibration period of five breaths the subject submerges completely, together with the bladder, and underwater weight is measured. Lung volume, at the time of weighing, is determined by hydrogen dilution. Using this method, the coefficient of variation for body density in the same individual was 0.23%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work proposes a novel dual-channel time-spread echo method for audio watermarking, aiming to improve robustness and perceptual quality. At the embedding stage, the host audio signal is divided into two subsignals, which are considered to be signals obtained from two virtual audio channels. The watermarks are implanted into the two subsignals simultaneously. Then the subsignals embedded with watermarks are combined to form the watermarked signal. At the decoding stage, the watermarked signal is split up into two watermarked subsignals. The similarity of the cepstra corresponding to the watermarked subsignals is exploited to extract the embedded watermarks. Moreover, if a properly designed colored pseudonoise sequence is used, the large peaks of its auto-correlation function can be utilized to further enhance the performance of watermark extraction. Compared with the existing time-spread echo-based schemes, the proposed method is more robust to attacks and has higher imperceptibility. The effectiveness of our method is demonstrated by simulation results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The 3S (Shrinking-Search-Space) multi-thresholding method which have been used for segmentation of medical images according to their intensities, now have been implemented and compared with FCM method in terms of segmentation quality and segmentation time as a benchmark in thresholding. The results show that 3S method produced almost the same segmentation quality or in some occasions better quality than FCM, and the computation time of 3S method is much lower than FCM. This is another superiority of this method with respect to others. Also, the performance of C-means has been compared with two other methods. This comparison shows that, C-means is not a reliable clustering algorithm and it needs several run to give us a reliable result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical methodology based on headspace solid phase microextraction (HS-SPME) combined with comprehensive two-dimensional gas chromatography—time-of-flight mass spectrometry (GC × GC–ToFMS) was developed for the identification and quantification of the toxic contaminant ethyl carbamate (EC) directly in fortified wines. The method performance was assessed for dry/medium dry and sweet/medium sweet model wines, and for quantification purposes, calibration plots were performed for both matrices using the ion extraction chromatography (IEC) mode (m/z 62). Good linearity was obtained with a regression coefficient (r2) higher than 0.981. A good precision was attained (R.S.D. <20%) and low detection limits (LOD) were achieved for dry (4.31 μg/L) and sweet (2.75 μg/L) model wines. The quantification limits (LOQ) and recovery for dry wines were 14.38 μg/L and 88.6%, whereas for sweet wines were 9.16 μg/L and 99.4%, respectively. The higher performance was attainted with sweet model wine, as increasing of glucose content improves the volatile compound in headspace, and a better linearity, recovery and precision were achieved. The analytical methodology was applied to analyse 20 fortified Madeira wines including different types of wine (dry, medium dry, sweet, and medium sweet) obtained from several harvests in Madeira Island (Portugal). The EC levels ranged from 54.1 μg/L (medium dry) to 162.5 μg/L (medium sweet).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Poly(p-phenylene vinylene) (PPV) derivatives are well known for their applications in polymer light emitting diodes (PLEDs). PPV derivatives are highly susceptible to photo-oxidation though, which is mainly caused by the scission of the vinyl double bond on the polymer backbone. In this work, we show that Langmuir-Blodgett (LB) films are less degraded than cast films of a PPV derivative (OC1OC6-PPV). Both films had similar thickness (similar to 50 nm) to allow for a more realistic comparison. Degradation was monitored with UV-vis and FTIR spectroscopies. The results indicated that cast films were completely degraded in ca. 400 min, while LB took longer time, i.e. about four times the values for the cast films. The differences can be attributed to the more compact morphology in the LB than in the cast films. With a compact morphology the diffusion of oxygen in the LB film is hampered and this causes a delay in the degradation process. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On the basis of information provided by the Brazilian Association of Race Horse Breeders, we analysed the racing performance of 947 Thoroughbred horses in races held from 1985 to 1992. The performance was evaluated using the best, time of the animals. The variance component was obtained by the derivative-free restricted maximum likelihood method, and the model used contained fixed effects of the racing month and year, sex, race track, track condition, animal age, number of competitors in race, and distance, and the random animal effect. The low heritability estimate obtained (0.12) indicates that selection based on animal phenotypic value must induce small genetic changes in this trail.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have examined the applicability of the 'nested' collision induced dissociation/post-source decay (CID/PSD) method to the sequencing of novel peptides from solitary wasps which have neurotoxic venom for paralyzing other insects. The CID/PSD spectrum of a ladder peptide derived from an exopeptidase digest was compared with that of the intact peptide. The mass peaks observed only in the CID/PSD spectrum of a ladder peptide were extracted as C-terminal fragment ions. Assignment of C-terminal fragment ions enabled calculation of N-terminal fragment masses, leading to differentiation between N-terminal fragment ions and internal fragment ions. This methodology allowed rapid and sensitive identification by removing ambiguity in the assignment of the fragment ions, and proved useful for sequencing unknown peptides, in particular those available as natural products with a limited supply. Copyright (C) 2000 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The iterative quadratic maximum likelihood IQML and the method of direction estimation MODE are well known high resolution direction-of-arrival DOA estimation methods. Their solutions lead to an optimization problem with constraints. The usual linear constraint presents a poor performance for certain DOA values. This work proposes a new linear constraint applicable to both DOA methods and compare their performance with two others: unit norm and usual linear constraint. It is shown that the proposed alternative performs better than others constraints. The resulting computational complexity is also investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the identification and quantification of pesticide residues in water, soil, and sediment samples has been developed, validated, and applied for the analysis of real samples. The specificity was determined by the retention time and the confirmation and quantification of analyte ions. Linearity was demonstrated over the concentration range of 20 to 120 µg L(-1), and the correlation coefficients varied between 0.979 and 0.996, depending on the analytes. The recovery rates for all analytes in the studied matrix were between 86% and 112%. The intermediate precision and repeatability were determined at three concentration levels (40, 80, and 120 µg L(-1)), with the relative standard deviation for the intermediate precision between 1% and 5.3% and the repeatability varying between 2% and 13.4% for individual analytes. The limits of detection and quantification for fipronil, fipronil sulfide, fipronil-sulfone, and fipronil-desulfinyl were 6.2, 3.0, 6.6, and 4.0 ng L(-1) and 20.4, 9.0, 21.6, and 13.0 ng L(-1), respectively. The method developed was used in water, soil, and sediment samples containing 2.1 mg L(-1) and 1.2% and 5.3% of carbon, respectively. The recovery of pesticides in the environmental matrices varied from 88.26 to 109.63% for the lowest fortification level (40 and 100 µg kg(-1)), from 91.17 to 110.18% for the intermediate level (80 and 200 µg kg(-1)), and from 89.09 to 109.82% for the highest fortification level (120 and 300 µg kg(-1)). The relative standard deviation for the recovery of pesticides was under 15%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Time-of-flight photoemission spectromicroscopy was used to measure and compare the two-photon photoemission (2PPE) spectra of Cu and Ag nanoparticles with linear dimensions ranging between 40 nm and several 100 nm, with those of the corresponding homogeneous surfaces. 2PPE was induced employing femtosecond laser radiation from a frequency-doubled Ti:sapphire laser in the spectral range between 375 nm and 425 nm with a pulse width of 200 fs and a repetition rate of 80 MHz. The use of a pulsed radiation source allowed us to use a high-resolution photoemission electron microscope as imaging time-of-flight spectrometer, and thus to obtain spectroscopic information about the laterally resolved electron signal. Ag nanoparticle films have been deposited on Si(111) by electron-beam evaporation, a technique leading to hemispherically-shaped Ag clusters. Isolated Cu nanoparticles have been generated by prolonged heating of a polycrystalline Cu sample. If compared to the spectra of the corresponding homogeneous surfaces, the Cu and Ag nanoparticle spectra are characterized by a strongly enhanced total 2PPE yield (enhancement factor up to 70), by a shift (about 0.1 eV) of the Fermi level onset towards lower final state energies, by a reduction of the work function (typically by 0.2 eV) and by a much steeper increase of the 2PPE yield towards lower final state energies. The shift of the Fermi level onset in the nanoparticle spectra has been explained by a positive unit charge (localized photohole) residing on the particle during the time-scale relevant for the 2PPE process (few femtoseconds). The total 2PPE yield enhancement and the different overall shape of the spectra have been explained by considering that the laser frequency was close to the localized surface plasmon resonance of the Cu and Ag nanoparticles. The synchronous oscillations induced by the laser in the metal electrons enhance the near-zone (NZ) field, defined as the linear superposition of the laser field and the field produced in the vicinity of the particles by the forced charge oscillations. From the present measurements it is clear that the NZ field behavior is responsible for the 2PPE enhancement and affects the 2PPE spatial and energy distribution and its dynamics. In particular, its strong spatial dependence allows indirect transitions through real intermediate states to take place in the metal clusters. Such transitions are forbidden by momentum conservation arguments and are thus experimentally much less probable on homogeneous surfaces. Further, we investigated specially tailored moon-shaped small metal nanostructures, whose NZ field was theoretically predicted, and compared the calculation with the laterally resolved 2PPE signal. We could show that the 2PPE signal gives a clear fingerprint of the theoretically predicted spatial dependence of the NZ field. This potential of our method is highly attractive in the novel field of plasmonics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The severity of aortic regurgitation can be estimated using pressure half time (PHT) of the aortic regurgitation flow velocity, but the correlation between regurgitant fraction and PHT is weak. AIM To test the hypothesis that the association between PHT and regurgitant fraction is substantially influenced by left ventricular relaxation. METHODS In 63 patients with aortic regurgitation, subdivided into a group without (n = 22) and a group with (n = 41) left ventricular hypertrophy, regurgitant fraction was calculated using the difference between right and left ventricular cardiac outputs. Left ventricular relaxation was assessed using the early to late diastolic Doppler tissue velocity ratio of the mitral annulus (E/ADTI), the E/A ratio of mitral inflow (E/AM), and the E deceleration time (E-DT). Left ventricular hypertrophy was assessed using the M mode derived left ventricular mass index. RESULTS The overall correlation between regurgitant fraction and PHT was weak (r = 0.36, p < 0.005). In patients without left ventricular hypertrophy, there was a significant correlation between regurgitant fraction and PHT (r = 0.62, p < 0.005), but not in patients with left ventricular hypertrophy. In patients with a left ventricular relaxation abnormality (defined as E/ADTI< 1, E/AM< age corrected lower limit, E-DT >/= 220 ms), no associations between regurgitant fraction and PHT were found, whereas in patients without left ventricular relaxation abnormalities, the regurgitant fraction to PHT relations were significant (normal E/AM: r = 0.57, p = 0.02; E-DT< 220 ms: r = 0.50, p < 0.001; E/ADTI < 1: r = 0.57, p = 0.02). CONCLUSIONS Only normal left ventricular relaxation allows a significant decay of PHT with increasing aortic regurgitation severity. In abnormal relaxation, which is usually present in left ventricular hypertrophy, wide variation in prolonged backward left ventricular filling may cause dissociation between the regurgitant fraction and PHT. Thus the PHT method should only be used in the absence of left ventricular relaxation abnormalities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Methods of heat detection were compared in the Mid- Crest Area Cattle Evaluation Program (MACEP) heifer development program in the 1998-breeding season. A total of 189 heifers from thirteen consignors entered the program on November 10, 1997. These heifers were condition scored, hip height measured, weighed, disposition scored, booster vaccinated, and treated for parasites at the time of arrival. Determination of the heifer’s mature weight was made and a target of 65% of their mature weight at breeding was established. The ration was designed to meet this goal. The heifers were kept in a dry lot until all heifers were AI bred once. The heifers were periodically weighed and condition scored to monitor their gains and the ration was adjusted as needed. The estrus synchronization program consisted of an oral progesterone analog for 14 days; 17 days after completion of the progesterone analog treatment a single injection of prostaglandin was given and the heifers were then estrus detected. Two concurrent methods of estrus detection were utilized: 1) Ovatec â electronic breeding probe (probe), 2) HeatWatchâ estrus detection system (HW), and 3) a combination of probe and HW. Probe readings were obtained each 12 hours and the heifers were continuously monitored for estrus activity using the HW system. The probe was used as the primary estrus detection method and the HW system was used as a back-up system. Those heifers that did not demonstrate any estrus signs prior to 96 hours post prostaglandin treatment were mass inseminated at 96 hours. Post AI breeding, 151 of the heifers were placed on pasture and ran with clean-up bulls for 60 days. The remaining heifers left the program after the AI breeding was completed. Pregnancy to the AI breeding was determined by ultrasound on June 29, 1998. Results from using both probe and HW were 60% pregnant by AI, probe alone was 32% pregnant by AI, and HW alone was 27% pregnant by AI. The result of mass insemination was 20% pregnant by AI.