939 resultados para Sperm DNA Extraction


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: to verify the viability of early diagnosis of fetal gender in maternal plasma by the real-time polymerase chain reaction (real-time PCR) starting at the 5th week of pregnancy. Methods: peripheral blood was collected from pregnant women with single fetus starting at the 5th week of gestation. After centrifugation, 0.4 mL plasma was separated for fetal DNA extraction. The DNA was analyzed in duplicate by real-time PCR for two genomic regions, one of the Y chromosome and the other common to both sexes, through the TaqMan® method, which uses a pair of primers and a fluorescent probe. Patients who aborted were excluded. Results: a total of 79 determinations of fetal DNA in maternal plasma were performed in 52 pregnant women. The results of the determinations were compared to fetal gender after delivery. Accuracy according to gestational age was 92.6% (25 of 27 cases) at 5 weeks with 87% sensitivity, and 95.6% (22 of 23 cases) at 6 weeks with 92% sensitivity. Starting at the 7th week of pregnancy, accuracy was 100% (29 of 29 cases). Specificity was 100% regardless of gestational age. Conclusion: real-time PCR for the detection of fetal gender in maternal plasma starting at the 5th week of gestation has good sensitivity and excellent specificity. There was agreement of the results in 100% of the cases in which male gender was diagnosed, regardless of gestational age, and from the 7th week of gestation for female gender diagnosis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

SNaPshot minisequencing reaction is in increasing use because of its fast detection of many polymorphisms in a single assay. In this work we described a highly sensitive single nucleotide polymorphisms (SNPs) typing method with detection of 42 mitochondrial DNA (mtDNA) SNPs in a single PCR and SNaPshot multiplex reaction in order to allow haplogroup classification in Latin American admixture population. We validated the panel typing 160 Brazilian individuals. DNA was extracted from blood spotted on filter paper using Chelex protocol. Forty SNPs were selected targeting haplogroup-specific mutations in Europeans, Africans and Asians (only precursors of Native Americans haplogroups A2, B2, C1, and D1) and two non-coding SNPs were chosen to increase the power of discrimination between individuals (SNPs positions 16,519 and 16,362). It was done using a modified version of a previously published multiplex SNaPshot minisequencing reaction established to resolve European haplogroups, adding SNPs targeting Africans (L0, L1, L2, L3, and L*) and Asians (A, B, C, and D) haplogroups based on SNPs described at PhyloTree.org build 2. PCR primers were designed using PerlPrimer software and checked with the Autodimer program. Thirty-three primer-pairs were used to amplify 42 SNPs. Using this panel, we were able to successfully classify 160 individuals into their correct haplogroups. Complete SNP profiles were obtained from 10. pg of total DNA. We conclude that it is possible to build and genotype more than 40 mtDNA SNPs in a single multiplex PCR and SNaPshot reaction, with sensitivity and reliability, resolving haplogroup classification in admixture populations. © 2011.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Several studies seek biological markers that give diagnostic and degree of tumor development. The aim of this study was to validate the determination of plasma DNA using nanotechnology (Nanovue™-NV) in samples of 80 patients with prostate cancer. Methods. Blood samples of 80 patients of the Urology Ambulatory of Faculdade de Medicina do ABC with prostate cancer confirmed by anatomical-pathology criteria were analyzed. DNA extraction was performed using a GFX TM kit (Amersham Pharmacia Biotech, Inc, USA) following the adapted protocol. Plasma was subjected to centrifugation. Results: There was a big difference between the first and the second value obtained by NanoVue Only two samples had no differences between duplicates. Maximum difference between duplicates was 38 μg/mL. Average variation between 51 samples was 10.29 μg/mL, although 21 samples had differences above this average. No correlation was observed between pDNA obtained by traditional spectrophotometry and by nanotechnology. Conclusion: Determination of plasma DNA by nanotechnology was not reproducible. © 2013 Moreno et al; licensee BioMed Central Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We tried to amplify mitochondrial, microsatellite and amelogenin loci in DNA from fecal samples of a wild Mazama americana population. Fifty-two deer fecal samples were collected from a 600-ha seasonal semideciduous forest fragment in a subtropical region of Brazil (21°20′, 47°17′W), with the help of a detection dog; then, stored in ethanol and georeferenced. Among these samples 16 were classified as fresh and 36 as non-fresh. DNA was extracted using the QIAamp® DNA Stool Mini Kit. Mitochondrial loci were amplified in 49 of the 52 samples. Five microsatellite loci were amplified by PCR; success in amplification varied according to locus size and sample age. Successful amplifications were achieved in 10/16 of the fresh and in 13/36 of the non-fresh samples; a negative correlation (R = -0.82) was found between successful amplification and locus size. Amplification of the amelogenin locus was successful in 22 of the 52 samples. The difficulty of amplifying nuclear loci in DNA samples extractedfrom feces collected in the field was evident. Some methodological improvements, including collecting fresh samples, selecting primers for shorter loci and quantifying the extracted DNA by real-time PCR, are suggested to increase amplification success in future studies. © FUNPEC-RP.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Fisiopatologia em Clínica Médica - FMB

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Tuberculosis (TB) is a granulomatous disease caused by Mycobacterium tuberculosis. The genus Mycobacteriumhas two different complexes: M. tuberculosis Complex and M. avium Complex. This is a global health epidemic and remains a major global health problem, besides, the clinical severity of TB is significantly higher in transplanted patients. The detection of these mycobacteria complexes in transplanted patients, by molecular methods, is fundamental for quick treatment of patients and can contribute for rapid and accuracy of diagnosis. Objective: To detect mycobacteria DNA of M. tuberculosis and M. avium Complexes in formalin fixed paraffin-embedded samples (FFPE) of two patients groups: non transplanted and transplanted. Materials and Methods: The study includes 40 FFPE biopsies separated in four groups: NTP – presence of epithelioid granuloma and positive ZN, non-transplanted patients – 9 samples; NTN - presence of epithelioid granuloma and negative ZN, non-transplanted patients – 10 samples; TP – positive ZN, transplanted patients – 9 samples; TN – negative ZN, transplanted patients – 7 samples. Sections were cut for DNA extraction. Samples were submitted to PCR for amplification of: a) β-actin, b) IS6110 insertion and c) IS1245 insertion. DNA evaluation was made by spectrophotometry and efficiency and PCR analysis was made by agarose gels under UV light. Results: In all samples processed, 97.1% were positive for human β-actin gene. In22.2% of NTP group were found the IS6110 insertion sequencebut the IS1245 wasn´t. In the NTN group was not found any sequence. In theTP group, 11.1% of the samples were positive for IS6110 and also 11,1% werepositive for IS1245. In the TN group, 14.3% of the samples were positive forIS6110 and for IS1245, 14.3% was also positive. Conclusion: Although factors such as DNA degradation after formalin fixation and paraffin embedding, were possible to detect DNA from the human gene ...

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Several reasons may lead to the failure of polymerase chain reaction (PCR) using DNA purified from paraffin-embedded materials: presence of inhibitors and degradation of target DNA. DNA dilution will often reduce the concentration of potential inhibitors and still contain enough DNA to allow PCR amplification. Objective: To evaluate the dilution influence of DNA purified from paraffin-embedded materials on β-globin PCR amplification. Material and Method: Paraffin-embedded blocks from 30 patients with oropharynx squamous cell carcinomas, diagnosed and treated at the Oral Oncology Center were selected. DNA extraction was performed using QIAmp minikit (Quiagen). DNA was quantified and evaluated for purity by spectrophotometer analysis. Two groups were formed with different amounts of DNA: group I had the originally extracted DNA and group II had the same DNA, however diluted with ultrapure water addition. PCR was performed in both groups using oligonucleotides for human β-globin gene. Results: For Group I, amplification of the β-globin gene sequence was successful in 33.33% of the samples and for Group II, in 23.33%. Conclusion: Dilution of the DNA extracted of paraffin-embedded materials did not modify statistically the amount of positive samples β-globin gene amplified in PCR, although the results suggest that this is a way to increase the method for efficacy amplification of PCR.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The identification of Salmonella spp. in food samples by microbiological diagnosis is time consuming, with approximately five different stages, requiring about 120 hours until the final result. The utilization of the polymerase chain reaction technique (PCR) can reduce this time, but substances present in samples may affect the reaction. The present work aimed to compare DNA extraction by thermic treatment and by the use of cetyltrimethil ammonium bromide (CTAB), in products originated from poultry houses corresponding to raw material (meat meal) and experimentally contaminated drag swabs. Materials obtained from the extractions were submitted to PCR, utilizing a pair of initiator oligonucleotides for amplification of Sdf 1 gene fragments. Comparing the methods of extraction, it was observed that when CTAB was employed, SE was detected in 70% of meat meal and in 80% of drag swabs, while the thermic treatment method yielded positive results in 20% of meat meal and in 40% of drag swabs. SE was detected under both methods utilized for DNA extraction, but the use of CTAB detected a greater number of positive samples, compared with thermal treatment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE To assess the effect of varicocele on sperm DNA integrity, mitochondrial activity, lipid peroxidation and acrosome integrity. PATIENTS AND METHODS In all, 30 patients with a clinically diagnosed varicocele of grade II or III and 32 men without a varicocele were evaluated for sperm DNA fragmentation (comet assay), mitochondrial activity (3,3'-diaminobenzidine assay), lipid peroxidation (malondialdehyde) and acrosome integrity (fluorescent probe labelled peanut agglutinin). RESULTS The varicocele group showed fewer spermatozoa with intact DNA (grade II, P = 0.040), more cells with inactive mitochondria (class III, P = 0.001), fewer cells with active mitochondria (class I, P = 0.005) and fewer spermatozoa with intact acrosomes (P < 0.001). Finally, no significant differences were observed in lipid peroxidation levels. CONCLUSION Men with varicocele showed an increase in sperm DNA fragmentation and a reduction in mitochondrial activity and acrosome integrity. However, lipid peroxidation levels remained unchanged.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In most pathology laboratories worldwide, formalin-fixed paraffin embedded (FFPE) samples are the only tissue specimens available for routine diagnostics. Although commercial kits for diagnostic molecular pathology testing are becoming available, most of the current diagnostic tests are laboratory-based assays. Thus, there is a need for standardized procedures in molecular pathology, starting from the extraction of nucleic acids. To evaluate the current methods for extracting nucleic acids from FFPE tissues, 13 European laboratories, participating to the European FP6 program IMPACTS (www.impactsnetwork.eu), isolated nucleic acids from four diagnostic FFPE tissues using their routine methods, followed by quality assessment. The DNA-extraction protocols ranged from homemade protocols to commercial kits. Except for one homemade protocol, the majority gave comparable results in terms of the quality of the extracted DNA measured by the ability to amplify differently sized control gene fragments by PCR. For array-applications or tests that require an accurately determined DNA-input, we recommend using silica based adsorption columns for DNA recovery. For RNA extractions, the best results were obtained using chromatography column based commercial kits, which resulted in the highest quantity and best assayable RNA. Quality testing using RT-PCR gave successful amplification of 200 bp-250 bp PCR products from most tested tissues. Modifications of the proteinase-K digestion time led to better results, even when commercial kits were applied. The results of the study emphasize the need for quality control of the nucleic acid extracts with standardised methods to prevent false negative results and to allow data comparison among different diagnostic laboratories.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Classical antibody-based serotyping of Escherichia coli is an important method in diagnostic microbiology for epidemiological purposes, as well as for a rough virulence assessment. However, serotyping is so tedious that its use is restricted to a few reference laboratories. To improve this situation we developed and validated a genetic approach for serotyping based on the microarray technology. The genes encoding the O-antigen flippase (wzx) and the O-antigen polymerase (wzy) were selected as target sequences for the O antigen, whereas fliC and related genes, which code for the flagellar monomer, were chosen as representatives for the H phenotype. Starting with a detailed bioinformatic analysis and oligonucleotide design, an ArrayTube-based assay was established: a fast and robust DNA extraction method was coupled with a site-specific, linear multiplex labeling procedure and hybridization analysis of the biotinylated amplicons. The microarray contained oligonucleotide DNA probes, each in duplicate, representing 24 of the epidemiologically most relevant of the over 180 known O antigens (O antigens 4, 6 to 9, 15, 26, 52, 53, 55, 79, 86, 91, 101, 103, 104, 111, 113, 114, 121, 128, 145, 157, and 172) as well as 47 of the 53 different H antigens (H antigens 1 to 12, 14 to 16, 18 to 21, 23 to 34, 37 to 43, 45, 46, 48, 49, 51 to 54, and 56). Evaluation of the microarray with a set of defined strains representing all O and H serotypes covered revealed that it has a high sensitivity and a high specificity. All of the conventionally typed 24 O groups and all of the 47 H serotypes were correctly identified. Moreover, strains which were nonmotile or nontypeable by previous serotyping assays yielded unequivocal results with the novel ArrayTube assay, which proved to be a valuable alternative to classical serotyping, allowing processing of single colonies within a single working day.