992 resultados para MUNSELL 100-HUE TEST
Resumo:
Buchheit, M, Al Haddad, H, Millet GP, Lepretre, PM, Newton, M, and Ahmaidi, S. Cardiorespiratory and cardiac autonomic responses to 30-15 Intermittent Fitness Test in team sport players. J Strength Cond Res 23(1): xxx-xxx, 2009-The 30-15 Intermittent Fitness Test (30-15IFT) is an attractive alternative to classic continuous incremental field tests for defining a reference velocity for interval training prescription in team sport athletes. The aim of the present study was to compare cardiorespiratory and autonomic responses to 30-15IFT with those observed during a standard continuous test (CT). In 20 team sport players (20.9 +/- 2.2 years), cardiopulmonary parameters were measured during exercise and for 10 minutes after both tests. Final running velocity, peak lactate ([La]peak), and rating of perceived exertion (RPE) were also measured. Parasympathetic function was assessed during the postexercise recovery phase via heart rate (HR) recovery time constant (HRRtau) and HR variability (HRV) vagal-related indices. At exhaustion, no difference was observed in peak oxygen uptake (&OV0312;o2peak), respiratory exchange ratio, HR, or RPE between 30-15IFT and CT. In contrast, 30-15IFT led to significantly higher minute ventilation, [La]peak, and final velocity than CT (p < 0.05 for all parameters). All maximal cardiorespiratory variables observed during both tests were moderately to well correlated (e.g., r = 0.76, p = 0.001 for &OV0312;o2peak). Regarding ventilatory thresholds (VThs), all cardiorespiratory measurements were similar and well correlated between the 2 tests. Parasympathetic function was lower after 30-15IFT than after CT, as indicated by significantly longer HHRtau (81.9 +/- 18.2 vs. 60.5 +/- 19.5 for 30-15IFT and CT, respectively, p < 0.001) and lower HRV vagal-related indices (i.e., the root mean square of successive R-R intervals differences [rMSSD]: 4.1 +/- 2.4 and 7.0 +/- 4.9 milliseconds, p < 0.05). In conclusion, the 30-15IFT is accurate for assessing VThs and &OV0312;o2peak, but it alters postexercise parasympathetic function more than a continuous incremental protocol.
The Rose Bengal test in human brucellosis: a neglected test for the diagnosis of a neglected disease
Resumo:
Brucellosis is a highly contagious zoonosis affecting livestock and human beings. The human disease lacks pathognomonic symptoms and laboratory tests are essential for its diagnosis. However, most tests are difficult to implement in the areas and countries were brucellosis is endemic. Here, we compared the simple and cheap Rose Bengal Test (RBT) with serum agglutination, Coombs, competitive ELISA, Brucellacapt, lateral flow immunochromatography for IgM and IgG detection and immunoprecipitation with Brucella proteins. We tested 208 sera from patients with brucellosis proved by bacteriological isolation, 20 contacts with no brucellosis, and 1559 sera of persons with no recent contact or brucellosis symptoms. RBT was highly sensitive in acute and long evolution brucellosis cases and this related to its ability to detect IgM, IgG and IgA, to the absence of prozones, and to the agglutinating activity of blocking IgA at the pH of the test. RBT was also highly specific in the sera of persons with no contact with Brucella. No test in this study outperformed RBT, and none was fully satisfactory in distinguishing contacts from infected patients. When modified to test serum dilutions, a diagnostic titer >4 in RBT resulted in 87.4% sensitivity (infected patients) and 100% specificity (contacts). We discuss the limitations of serological tests in the diagnosis of human brucellosis, particularly in the more chronic forms, and conclude that simplicity and affordability of RBT make it close to the ideal test for small and understaffed hospitals and laboratories.
Resumo:
A avaliação do processamento radiográfico utilizando o "STEP test" ("sensitometric test for the evaluation of processing") tem como objetivo a identificação de desvios importantes no sistema processadora-químicos-filmes. Neste tipo de avaliação são estabelecidas as condições ideais para o processamento. Um filme padrão é revelado de acordo com as condições do fabricante, ou seja, com padrão igual a 100. O filme é exposto à luz de um sensitômetro calibrado e os valores dos degraus são avaliados com o uso de um densitômetro, sendo obtida sua curva característica (densidade óptica × degrau). O desvio porcentual máximo deve ser de 20% quando comparado com a curva padrão. Este método é útil na identificação de problemas no processamento radiográfico. Várias processadoras de hospitais públicos/universitários foram avaliadas empregando este método, e verificou-se que aproximadamente 33% das instalações apresentam condições inadequadas de processamento.
Resumo:
BACKGROUND: Fever is a frequent cause of medical consultation among returning travelers. The objectives of this study were to assess whether physicians were able to identify patients with influenza and whether the use of an influenza rapid diagnostic test (iRDT) modified the clinical management of such patients. METHODS: Randomized controlled trial conducted at 2 different Swiss hospitals between December 2008 and November 2012. Inclusion criteria were 1) age ≥18 years, 2) documented fever of ≥38 °C or anamnestic fever + cough or sore throat within the last 4 days, 3) illness occurring within 14 days after returning from a trip abroad, 4) no definitive alternative diagnosis. Physicians were asked to estimate the likelihood of influenza on clinical grounds, and a single nasopharyngeal swab was taken. Thereafter patients were randomized into 2 groups: i) patients with iRDT (BD Directigen A + B) performed on the nasopharyngeal swab, ii) patients receiving usual care. A quantitative PCR to detect influenza was done on all nasopharyngeal swabs after the recruitment period. Clinical management was evaluated on the basis of cost of medical care, number of X-rays requested and prescription of anti-infective drugs. RESULTS: 100 eligible patients were referred to the investigators. 93 patients had a naso-pharyngeal swab for a PCR and 28 (30%) swabs were positive for influenza. The median probability of influenza estimated by the physician was 70% for the PCR positive cases and 30% for the PCR negative cases (p < 0.001). The sensitivity of the iRDT was only 20%, and specificity 100%. Mean medical cost for the patients managed with iRDT and without iRDT were USD 581 (95%CI 454-707) and USD 661 (95%CI 522-800) respectively. 14/60 (23%) of the patients managed with iRDT were prescribed antibiotics versus 13/33 (39%) in the control group (p = 0.15). No patient received antiviral treatment. CONCLUSION: Influenza was a frequent cause of fever among these febrile returning travelers. Based on their clinical assessment, physicians had a higher level of suspicion for influenza in PCR positive cases. The iRDT used in this study showed a disappointingly low sensitivity and can therefore not be recommended for the management of these patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT00821626.
Resumo:
Coxiella burnetii and members of the genus Rickettsia are obligate intracellular bacteria. Since cultivation of these organisms requires dedicated techniques, their diagnosis usually relies on serological or molecular biology methods. Immunofluorescence is considered the gold standard to detect antibody-reactivity towards these organisms. Here, we assessed the performance of a new automated epifluorescence immunoassay (InoDiag) to detect IgM and IgG against C. burnetii, Rickettsia typhi and Rickettsia conorii. Samples were tested with the InoDiag assay. A total of 213 sera were tested, of which 63 samples from Q fever, 20 from spotted fever rickettsiosis, 6 from murine typhus and 124 controls. InoDiag results were compared to micro-immunofluorescence. For acute Q fever, the sensitivity of phase 2 IgG was only of 30% with a cutoff of 1 arbitrary unit (AU). In patients with acute Q fever with positive IF IgM, sensitivity reached 83% with the same cutoff. Sensitivity for chronic Q fever was 100% whereas sensitivity for past Q fever was 65%. Sensitivity for spotted Mediterranean fever and murine typhus were 91% and 100%, respectively. Both assays exhibited a good specificity in control groups, ranging from 79% in sera from patients with unrelated diseases or EBV positivity to 100% in sera from healthy patients. In conclusion, the InoDiag assay exhibits an excellent performance for the diagnosis of chronic Q fever but a very low IgG sensitivity for acute Q fever likely due to low reactivity of phase 2 antigens present on the glass slide. This defect is partially compensated by the detection of IgM. Because it exhibits a good negative predictive value, the InoDiag assay is valuable to rule out a chronic Q fever. For the diagnosis of rickettsial diseases, the sensitivity of the InoDiag method is similar to conventional immunofluorescence.
Resumo:
One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.
Resumo:
The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.
Resumo:
A dissolution test for telithromycin tablets was validated and developed. In order to choose the most discriminatory one, the conditions to carry out are 900 mL of sodium phosphate buffer at pH 7.5, paddles at 50 rpm stirring speed, time test set to 60 min and using USP apparatus 2 with paddles. The UV spectrophotometric method for determination of telithromycin released was developed and validated. The method presents linearity (r = 1) in the concentration range of 20-60 µg/mL. Precision and recoveries were good, 100.62 and 97.06%, respectively. The method was successfully used for the dissolution test of telithromycin tablets.
Resumo:
A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.
Resumo:
A qualitative spot-test and tandem quantitative analysis of dipyrone in the bulk drug and in pharmaceutical preparations is proposed. The formation of a reddish-violet color indicates a positive result. In sequence a quantitative procedure can be performed in the same flask. The quantitative results obtained were statistically compared with those obtained with the method indicated by the Brazilian Pharmacopoeia, using the Student's t and the F tests. Considering the concentration in a 100 µL aliquot, the qualitative visual limit of detection is about 5×10-6 g; instrumental LOD ≅ 1.4×10-4 mol L-1 ; LOQ ≅ 4.5×10-4 mol L-1.
Resumo:
This work established the adequate temperature and the period of exposition for the accelerated ageing test with diasporas of Myracrodruon urundeuva from an area of the Cerrado in the state of Mato Grosso, Brazil. Before and after the ageing, at the temperatures of 40ºC, 41ºC, 42ºC and 45ºC combined with periods of 12, 18, 24, 30 and 36 hours, the water content and germination were evaluated. For each treatment, 12g of diasporas in mini chambers with 40 mL of distilled water were submitted to the accelerated ageing test. A total of 100 diasporas, divided into four replications, in plastic boxes, on two sheets of blotting paper, in germinator at 25ºC and 8 hours of photoperiod were germinated. In all treatments the content of water of the aged diasporas was superior to 20% and this value stabilized itself between 25% and 28%, from the 18 hours of exposition. Independently of the tested periods, the ageing at the temperatures of 40ºC, 41ºC and 42ºC did not affect the germination. After the ageing at 45ºC, the germination did not differ among the periods of 12, 18 and 24 hours of exposition, but in all these periods it was inferior to the control and superior to the periods of 30 and 36 hours. In these last two periods, fungi were observed. The accelerated ageing of diasporas of Myracrodruon urundeuva should be conducted at the temperature of 45ºC, during the exposition periods of 12 to 24 hours.
Resumo:
Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
O "California Mastitis Test" (CMT) estima o conteúdo de células somáticas no leite e é interpretado subjetivamente, estabelecendo-se escores que, na maioria dos casos, variam de 1 a 5. O escore 1 indica uma reação completamente negativa e os de 2-5 indicam graus crescentes de resposta inflamatória do úbere, sendo normalmente considerados como indicativos de mastite subclínica. Dependendo da interpretação dos escores, o CMT pode produzir resultados falso-positivos ou falso-negativos. Esse trabalho teve o objetivo de avaliar a sensibilidade e a especificidade do CMT em relação à contagem de células somáticas (CCS). Foram utilizadas 3.012 amostras de leite provenientes de 760 vacas Holandesas ou mestiças Holandês-Zebu, pertencentes a 15 rebanhos. Todas as amostras foram submetidas ao CMT e processadas para CCS em equipamento Fossomatic 90. Os valores médios de CCS (x 1.000 células/ml) obtidos para os escores de CMT foram 1 (79,9), 2 (333,5), 3 (670,3), 4 (1.354,0) e 5 (4.455,6). Três opções de interpretação (doente/não-doente) para o CMT foram testadas, em relação aos valores de CCS, iniciando com 100.000 células/ml: (a) 1 versus 2, 3, 4, e 5; (b) 1 e 2 versus 3, 4 e 5; (c) 1, 2, 3 versus 4 e 5. As sensibilidades do CMT em identificar corretamente quartos mamários acima de 200.000 células/ml foram 79%, 61% e 34%, para as opções a, b e c, respectivamente. Para identificar corretamente contagens acima de 500.000 células/ml, as sensibilidades do CMT, para as opções a, b e c, foram, respectivamente: 93%, 82% e 54%. A sensibilidade do CMT em identificar quartos mamários com mastite subclínica foi adequada (acima de 80%) quando a interpretação do teste foi mais rigorosa (opções a e b). A interpretação da reação 3 como negativa (opção c) só alcançou sensibilidade de 80% para contagens entre 1.200.000 e 1.400.000 células/ml. As especificidades do CMT, para CCS de 200.000 e 500.000 foram, respectivamente, 90% e 80% (opção a), 97% e 90% (opção b) e 99% e 97% (opção c).
Resumo:
Group A Rotavirus (RVA) is one of the most common causes of diarrhea in humans and several animal species. A SYBR-Green Real-Time polymerase chain reaction (PCR) was developed to diagnose RVA from porcine fecal samples, targeting amplification of a 137-bp fragment of nonstructural protein 5 (NSP5) gene using mRNA of bovine NADH-desidrogenase-5 as exogenous internal control. Sixty-five samples were tested (25 tested positive for conventional PCR and genetic sequencing). The overall agreement (kappa) was 0.843, indicating 'very good' concordance between tests, presenting 100% of relative sensitivity (25+ Real Time PCR/25+ Conventional PCR) and 87.5% of relative sensitivity (35- Real Time PCR/40- Conventional PCR). The results also demonstrated high intra- and inter-assay reproducibility (coefficient of variation ≤1.42%); thus, this method proved to be a fast and sensitive approach for the diagnosis of RVA in pigs.