993 resultados para Jernström Offset


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In offset printing, dampening solution is used to create a good balance in the process. If too much water is transferred to the paper, the sheet can change its size between the printing units, due to water absorption, and cause a problem with the colour register. This phenomenon is usually referred to as fanout. In this degree project, an investigation was made to see if the paper dimensions changed through its way in the sheet-fed printing process. The instrument Luchs Register Measuring Systems (Lynx) was used, and a method for measuring if the paper changed its dimensions with this instrument, was developed. Paper qualities with three different grammages were used, 90, 130 and 250 gsm. This investigation showed that all paper qualities changed their size with widening in the gripper edge in the range of 10 - 70 µm and in the trailing edge the increase was 10 - 130 µm. The elongations of the papers were in the range of 10- 300 µm. The papers with lowest grammage changed more than the heavier. To see if the print had been affected of the widening and elongation, print quality parameters like relative contrast, dot gain and mottle were correlated with the Lynx data from the sheets. The group of papers that gave correlations were in 130 gsm. The sheets had visual doubling and the combined standard deviation from the Lynx marks K3, K5 and K21 correlated with dot gain. When the variations increased so did the dot gain and this indicates that the doubling was due to the widening. There was also a correlation between the standard deviation from K3 and Mottle. The sheets widened with an average of 30 µm in the gripper edge and since there probably were doubling due to widening it also affected the Mottle values. What the widening depends on is hard to tell. Since widening was so small, it could be due to water absorption, papers being ironed out or maybe the sheets have been flattened out. It probably needs a more detailed investigation to find out what causes the widening. Further investigations about how print quality is affected by the register accuracy of a printing machine should include a print form with measuring areas close to the Lynx marks. The measuring areas should contain fine hairlines, negative text printed with at least two colours and some pictures to evaluate together with standard measuring should give a good knowledge about the subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PAPRO operates within the Forest Research company and their mission is to develop value-addingindustry solutions. At present there are no good ways for mills to easily test the printing quality on newsprintpaper. There is a great need for a fast way to do this on different paper qualities; with a laboratory-offset press this can be both a time and money saving method. At PAPRO Forest Research, NewZealand, a laboratory offset press has been developed and designed, during the past seven years, concerningthis issue. Earlier projects were made concerning the press, e.g. to establish the optimal settings.The mission with this project was to partly determine the present variability of the print quality andto evaluate if the fountain solution, distilled water and 2% Diol green concentrate, used at the momentmixed with different percentages of Isopropanol could decrease the variability and contribute to morestabile results. Throughout the whole project the print quality showed a high variation and was evenmore variable when the Isopropanol was added. All in all 50 print rounds times twelve printed paperstrips was carried out through the project divided into three parts. To analyse the print quality, amicroscope with an image capture camera has been used. Data from the taken images was analysedand inserted into charts to see the variations.The conclusions of the whole project are not satisfying because no final evaluations were possible tomake. Main conclusions are that the additive of Isopropanol to the ordinary fountain solution, used atpresent, only contributed to more unstable results of the print quality. And it seems to be difficult toget some stable results from the lab press as long as the room where it is placed is not fully conditionedas required for the process of offset printing. And the fact that the airbrush which applies theamount of fountain solution is also variable, as shown in earlier projects, which contributes to unstableresults as well. For further work more exact parameters as a conditioned room are required and thepossibility to further design the laboratory press to use waterless offset printing instead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyses the kinematics of a special 6-DOF parallel micro-manipulator with offset RR-joint configuration. Kinematics equations are derived and numerical methodologies to solve the inverse and forward kinematics are presented. The inverse and forward kinematics of such robots compared with those of 6-UCU parallel robots are more complicated due to the existence of offsets between joints of RR-pairs. The characteristics of RR-pairs used in this manipulator are investigated and kinematics constraints of these offset U-joints are mathematically explained in order to find the best initial guesses for the numerical solution. Both inverse and forward kinematics of the case study 6-DOF parallel micro-manipulator are modelled and computational analyses are performed to numerically verify accuracy and effectiveness of the proposed methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyses the kinematics of a special 6-DOF parallel micro-manipulator with offset RR-joint configuration. Kinematics equations are derived and numerical methodologies to solve the inverse and forward kinematics are presented. The inverse and forward kinematics of such robots compared with those of 6-UCU parallel robots are more complicated due to the existence of offsets between joints of RR-pairs. The characteristics of RR-pairs used in this manipulator are investigated and kinematics constraints of these offset U-joints are mathematically explained in order to find the best initial guesses for the numerical solution. Both inverse and forward kinematics of the case study 6-DOF parallel micro-manipulator are modelled and computational analyses are performed to numerically verify accuracy and effectiveness of the proposed methodologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology for the numerical solution of the forward kinematics problem of 6-RRCRR parallel manipulators with orthogonal non-intersecting RR-joint configuration is presented in this article. The inverse and forward kinematics solutions of such robots compared with that of parallel robots with orthogonal intersecting RR-joint or universal joint configurations are much more complicated due to the existence of dependent joint variables. The constraints of RR-joints are analysed and the numerical algorithm for the forward kinematics solution is assessed. Numerical results for the solution of the forward kinematics of 6-RRCRR parallel robot under study are provided to confirm the accuracy and efficiency of the procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biodiversity offsets can be an important tool for maintaining or enhancingenvironmental values in situations where development is sought despite negativeenvironmental impacts. There are now approximately 45 compensatory mitigationprograms for biodiversity impacts worldwide, with another 27 programs in development. While offsets have great potential as a conservation tool, their establishment requires overcoming a number of conceptual and methodological hurdles. In Australia, new policy changes at the national and state (i.e., Western Australia) level require that offsets follow a set of general principles: (1) Environmental offsets may not be appropriate for all projects and will only be considered after avoidance and mitigation options have been pursued;(2) Environmental offsets will be based on sound environmental information andknowledge; (3) Establishing goals for offsets requires an estimate of expected direct and indirect impacts; (4) Environmental offsets will be focused on longer term strategic outcomes; (5) Environmental offsets will be cost-effective, as well as relevant and proportionate to the significance of the environmental value being impacted. Here we focus on the challenges of determining and implementing offsets using a real world example from a voluntary offset process undertaken for Barrick Gold’s Kanowna Belle mine site in Western Australia to highlight those challenges and potential solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the results of a study on vinyl bromide for the search for new far infrared (FIR) laser lines. As the pump source, we use a CW waveguide CO2 laser with a tunability of 290 MHz around each line in order to pump large offset vibrational transitions. As a consequence, we obtained 28 new FIR laser emissions; 24 of them have wavelengths greater than 500 mum and are, therefore, suitable to be used in high-field EPR spectroscopy, For each of the new lines, we give the wavelength, the offset of the pumping transition with respect to the center Frequency of the CO2 emission, the polarization relative to that of the pumping laser line, the operating pressure, and the relative intensity. We also present a catalog including data of all of the FIR laser lines observed from this molecule up to now.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The present study was designed to analyze strain distributions caused by varying the fixture-abutment design and fixture alignment.Materials and Methods: Three implants of external, internal hexagon, and Morse taper were embedded in the center of each polyurethane block in straight placement and offset placement. Four strain gauges (SGs) were bonded on the surface of polyurethane block, which was designated SG1 placed mesially adjacent to implant A, SG2 and SG3 were placed mesially and distally adjacent to the implant B and SG4 was placed distally adjacent to the implant C. The 30 superstructures' occlusal screws were tightened onto the Microunit abutments with a torque of 10 N cm using the manufacturers' manual torque-controlling device.Results: There were statistically significant differences in prosthetic connection (P value = 0.0074 < 0.5). There were no statistically significant differences in placement configuration/alignment (P value = 0.7812 > 0.5).Conclusion: The results showed fundamental differences in both conditions. There was no evidence that there was any advantage to offset implant placement in reducing the strain around implants. The results also revealed that the internal hexagon and Morse taper joints did not reduce the microstrain around implants. (Implant Dent 2011; 20:e24-e32)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of inks containing organic solvents by the offset printing process implies in the release of volatile organic compounds to the work environment. Many of these compounds such as benzene, toluene, ethylbenzene, and the xylene isomers (well known by the acronym BTEX) are extremely toxic. In this study, the BTEX concentrations were determined in two different printing plants that use distinct types of inks: the conventional and the so-called ecological, which is manufactured based on vegetal oil. Concentration ranges were 43-84, 15-3,480, 2-133, 5-459, and 2-236 μg m-3 for benzene, toluene, ethylbenzene, m + p-xylene, and o-xylene, respectively, for the conventional printing plant. At the ecological printing plant, concentration ranges were below limit of detection (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os tempos de reação manuais e sacádicos (TRMs e TRSs) são reduzidos quando um sinal de aviso precede o aparecimento do alvo. O decréscimo nos TRSs observados depois do desaparecimento do ponto de fixação tem sido chamado de efeito de intervalo. Teorias diferentes foram propostas para explicá-lo. De acordo com alguns autores, o desaparecimento também permite ao sistema sacádico gerar uma população separada de TRSs, as sacádicas expressas. No entanto, não há concordância sobre a influência do desaparecimento de um estímulo periférico no TRM. Em dois experimentos, testou-se os efeitos de um desaparecimento visual periférico empregado como um sinal preparatório para os TRMs a um alvo, após intervalos variáveis. Encontrou-se uma redução no TRM para intervalos curtos (200-300 ms) e longos (1300-2000 ms) após o desaparecimento periférico. A distribuição dos TRMs deslocou-se para latências curtas, formando por vezes populações separadas. Visto que os TRMs obtidos em intervalos longos foram afetados pela introdução de sessões capciosas, enquanto que os TRMs em intervalos curtos não o foram, propõe-se que dois mecanismos diferentes estão envolvidos no decréscimo dos TRMs: alerta e expectativa temporal. Nossos dados sustentam a hipótese de que o componente temporal envolvido com os estágios preparatórios das respostas motoras podem ser compartilhados pelos movimentos sacádicos e pelas respostas de apertar botões, permitindo a redução das latências motoras após o desaparecimento visual, dentro do paradigma do intervalo. Nossos dados corroboram o modelo de três componentes do efeito de intervalo. Em nosso ponto de vista, a questão da existência ou não do efeito de intervalo para respostas manuais é essencialmente conceitual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this systematic review was to compare straight-line and offset implant configurations for three-element implant-retained prostheses. Materials and Methods: Two independent reviewers conducted a review on PubMed/Medline, EMBASE, and Cochrane Library for studies published in English, from January 1, 1995 to January 17, 2014. A systematic review was conducted following the PRISMA statement. All relevant titles were selected according to inclusion/exclusion criteria. From this pool of titles, abstracts and full texts were reviewed. Results: A total of 6080 titles were identified with the initial search. Twenty-one were selected based on title and abstract. Of these, after discussion and complete reading, 12 studies were selected according to the inclusion and exclusion criteria, all of which were in vitro studies. Conclusions: A systematic review of the current literature showed only in vitro evidence that there is no consensus on the advantage of using an offset configuration implant compared to those in straight-line configuration, even though some studies present a slight improvement of bone stress distribution when an offset implant is under oblique loading (PICO).