Straight and Offset Implant Placement under Axial and Nonaxial Loads in Implant-Supported Prostheses: Strain Gauge Analysis


Autoria(s): Abreu, Celina Wanderley; Nishioka, Renato Sussumu; Balducci, Ivan; Consani, Rafael Leonardo Xediek
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/10/2012

Resumo

Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.

Formato

535-539

Identificador

http://dx.doi.org/10.1111/j.1532-849X.2012.00871.x

Journal of Prosthodontics-implant Esthetic and Reconstructive Dentistry. Hoboken: Wiley-blackwell, v. 21, n. 7, p. 535-539, 2012.

1059-941X

http://hdl.handle.net/11449/22972

10.1111/j.1532-849X.2012.00871.x

WOS:000310803300005

Idioma(s)

eng

Publicador

Wiley-Blackwell

Relação

Journal of Prosthodontics-implant Esthetic and Reconstructive Dentistry

Direitos

closedAccess

Palavras-Chave #Strain gauge #Morse taper implant #axial load